I want to search for...

Permit #2023050952

Permit Details

Status: COED

Parcel Id: 07-11-31-7063-00550-0020
CONDITIONED SPACE: 2303 sqft
GARAGE: 726 sqft
OPENED PORCH (WITH ROOF) : 404 sqft
Total Square Footage: 3433 sqft
Block: 00550
Subdivision: 2174 - SECTION 63-ZEBULAHS TRAIL
Job Phone: 386-237-8427
Location Address: 3 ZAHAROFF PL
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/09/2023
NOC: RECORDED
Applicant name: JAY DARREN CURBOW
Owner: BLUE WATER HOMES INC

Address

UNIT 1

PALM COAST, FL 32137

Address

4881 PALM COAST PKWY NW

PALM COAST, FL 32137

Lot: 0020
Contracted Stated Job Value: ¤339,901.00
Job Description: Single Family Residence
Type: CN

Contractor

BLUE WATER HOMES INC
Status Location Address State License Number Phone
ACTIVE

4881 PALM COAST PARKWAY NW UNIT 1

PALM COAST, FL 32137

CBC1258679 (Exp: 08/31/2026) 386-445-3405

Sub Contractors

WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965
JACK DOUGLAS LANIER
Status Location Address State License Number Phone Fax
ACTIVE

485 COMMERCE WAY

LONGWOOD , FL 32750

CCC058022 (Exp: 08/31/2026) (321)441-2300 (321)441-2313
BRETT CHRISTIAN GIBSON
Status Location Address State License Number Phone
ACTIVE

250 SEGOVIA RD

ST AUGUSTINE, FL 32086

CAC1818423 (Exp: 08/31/2026) 904-229-8131

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/11/2024 FINAL APPROVED RSIMS
Note: 4/11/24: Met PM on site. Waiting for door repair at @ 09:00. Will return is possible. 4/10/2024 - PREVIOUS INSPECTION NOTES 4/10/24: 1). SGD is not operating properly. Extremely difficult to open. 2). Exterior temporary cover on Lanai needs to be replaced with a weather rated cover as required. NEC - 406.6 / 406.9(2E) 4/8/2024 - PREVIOUS INSPECTION NOTES 4/8/24: Inspection Stopped! Not Ready! Walked with PM to identify initial items. Examples Only: Bathroom exhausts obstructed with debris on right side & back left, front left is crushed & not connected to vent properly. / Exterior sleeve for lineset is not fastened properly & soffit is opened very wide at the top / Copper condensate drain from condensate pump in garage is turned up outside & does not terminate properly. / Range anti-tip bracket is missing an anchor as required. 4/4/2024 - PREVIOUS INSPECTION NOTES 4/4/24: House is locked.
BLD - BUILDING FINAL 04/10/2024 Disapproved - NO FEE RSIMS
Note: 4/10/24: 1). SGD is not operating properly. Extremely difficult to open. 2). Exterior temporary cover on Lanai needs to be replaced with a weather rated cover as required. NEC - 406.6 / 406.9(2E) 4/8/2024 - PREVIOUS INSPECTION NOTES 4/8/24: Inspection Stopped! Not Ready! Walked with PM to identify initial items. Examples Only: Bathroom exhausts obstructed with debris on right side & back left, front left is crushed & not connected to vent properly. / Exterior sleeve for lineset is not fastened properly & soffit is opened very wide at the top / Copper condensate drain from condensate pump in garage is turned up outside & does not terminate properly. / Range anti-tip bracket is missing an anchor as required. 4/4/2024 - PREVIOUS INSPECTION NOTES 4/4/24: House is locked.
BLD - BUILDING FINAL 04/08/2024 Disapproved -FEE REQUIRED RSIMS
Note: 4/8/24: Inspection Stopped! Not Ready! Walked with PM to identify initial items. Examples Only: Bathroom exhausts obstructed with debris on right side & back left, front left is crushed & not connected to vent properly. / Exterior sleeve for lineset is not fastened properly & soffit is opened very wide at the top / Copper condensate drain from condensate pump in garage is turned up outside & does not terminate properly. / Range anti-tip bracket is missing an anchor as required. 4/4/2024 - PREVIOUS INSPECTION NOTES 4/4/24: House is locked.
U -UTILITY RESIDENTIAL FINAL 04/05/2024 FINAL APPROVED JHARDING
Note: 4/1/2024 - PREVIOUS INSPECTION NOTES No power to pep pump. checck breaker in garage.
BLD - BUILDING FINAL 04/04/2024 Disapproved - NO FEE RSIMS
Note: 4/4/24: House is locked.
U-CROSS CONNECTION 04/01/2024 APPROVED - AS NOTED JHARDING
Note: No irrigation, no cross connections.
U -UTILITY RESIDENTIAL FINAL 04/01/2024 Disapproved - NO FEE JHARDING
Note: No power to pep pump. checck breaker in garage.
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/28/2024 APPROVED TPOLACEK
Note: 03/28/24 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET.NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9270 2/12/24 PIPE IS FLAT (OK). YOU NEED TO PUT THE FORMBOARD IN THE CENTER OF THE DRIVEWAY APRON BACK TO WHERE IT WAS IT CAME LOOSE. APPROVING THIS PREPOUR AS NOTED DUE TO MINOR CORRECTION NEEDED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
ROW FIELD SURVEY /GRADING CERTIFICATION 03/28/2024 APPROVED TPOLACEK
Note: 03/28/24 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET.NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 03/28/2024 APPROVED TPOLACEK
Note: 03/28/24 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET.NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - FINAL APRON (AFTER POUR) 03/28/2024 APPROVED TPOLACEK
Note: 03/28/24 CONCRETE IS GOOD CUTS ARE MADE CULVERT CLEAR HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET.NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
PLUMBING OTHER 02/16/2024 APPROVED BTAYLOR
ELECTRIC - EARLY POWER 02/16/2024 APPROVED - AS NOTED BTAYLOR
Note: Inspector Notes from Inspection 2170 10-18-23 1. Emailed FPL at 11:30. 2-16-24 1. Emailed FPL at 11:26.
ROW- PRE-APRON (PRE-POUR) 02/12/2024 APPROVED - AS NOTED FSLADISH
Note: 2/12/24 PIPE IS FLAT (OK). YOU NEED TO PUT THE FORMBOARD IN THE CENTER OF THE DRIVEWAY APRON BACK TO WHERE IT WAS IT CAME LOOSE. APPROVING THIS PREPOUR AS NOTED DUE TO MINOR CORRECTION NEEDED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
U - SEWER TIE IN 01/08/2024 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 12/19/2023 APPROVED BVITALE
LATH/BRICK/ WATER BARRIER 12/11/2023 APPROVED RSIMS
INSULATION 12/07/2023 APPROVED BTAYLOR
Note: 12/5/2023 - PREVIOUS INSPECTION NOTES 12/5/23: 1). Firestop above breaker panel is incomplete at white romex wires. 2). Missing fire blocking & firestop to the left of kitchen exhaust duct. 3). Missing firestop between top plates of pack out walls at bathtub. 4). Missing cardboard baffles at ceiling level change along the left side. (where ceiling drops down from tray ceiling and is still above bedroom ceilings.
INSULATION 12/05/2023 Disapproved -FEE REQUIRED RSIMS
Note: 12/5/23: 1). Firestop above breaker panel is incomplete at white romex wires. 2). Missing fire blocking & firestop to the left of kitchen exhaust duct. 3). Missing firestop between top plates of pack out walls at bathtub. 4). Missing cardboard baffles at ceiling level change along the left side. (where ceiling drops down from tray ceiling and is still above bedroom ceilings.
ROOF VALLEY & METAL 12/01/2023 APPROVED BTAYLOR
Note: 11/27/2023 - PREVIOUS INSPECTION NOTES 11/27/23: Partial approval pending revision being submitted and approved for step flashing detail along with visual inspection once shingles are installed. 2nd part of inspection MUST be completed before any veneer is installed. 11/27/2023 - PREVIOUS INSPECTION NOTES 11/27/23: Previously listed deficiency not resolved. 11/27/23: Previously listed deficiency not resolved. Contractor stated that they will be doing step flashing as opposed to 5" x 5" continuous flashing. A revision showing this detail will need to be submitted to show details for step flashing as required. 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Inspection stopped! Not Complete. * Missing all 5" x 5" flashing. 11/3/2023 - PREVIOUS INSPECTION NOTES Roof sheating at truss F5, right side garage not nailed. First sheet at the eave.
ALL ROUGH 11/30/2023 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/29/2023 APPROVED KSANDOE
Note: 11/3/2023 - PREVIOUS INSPECTION NOTES 11/3/23 1. Truss plates or moisture barrier not installed where trusses land on CMU walls at multiple trusses throughout the building. 2. 2 over framing Ridge beams are to be support to create a continous load path. 3. Trusses B1, E5, CJ10, and EH5 are missing hold down anchors. 4. Trusses C1,2,3, and 4 at the front entry anchors require minimum of 9 fasteners. 5. The kneewall and the eave over framing at the front entry missing support blocking between trusses below and anchors / hold down straps. 6. Garage bearing wall 4x4 post and ABU44 anchor not installed. 7. Rear bearing wall between bed 3 and 4 not construted. 4x4 post, header, anchor bolts etc. 8. Rear porch 2x12 beam at the left side is supported on P.t. 2X6 Please porvide detail for this area. number of 2x required , anchoring to CMU and truss above. 9. NSPR blocking used for roof decking is to be SYP. remove at ares where roof decking edges are supported. Other areas can remain. Truss Engineering passed. Down cells passed. 11/1/2023 - PREVIOUS INSPECTION NOTES not ready for inspection, Missing 4x4 Post at detail-E Missing header at detail-D Missing MTS 18s Missing HTS 20s (all per plans and details) Inspection Stopped, nothing further looked at
ROOF VALLEY & METAL 11/27/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/27/23: Previously listed deficiency not resolved. Contractor stated that they will be doing step flashing as opposed to 5" x 5" continuous flashing. A revision showing this detail will need to be submitted to show details for step flashing as required. 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Inspection stopped! Not Complete. * Missing all 5" x 5" flashing. 11/3/2023 - PREVIOUS INSPECTION NOTES Roof sheating at truss F5, right side garage not nailed. First sheet at the eave.
ROOF VALLEY & METAL 11/27/2023 PARTIALLY APPROVED RSIMS
Note: 11/27/23: Partial approval pending revision being submitted and approved for step flashing detail along with visual inspection once shingles are installed. 2nd part of inspection MUST be completed before any veneer is installed. 11/27/2023 - PREVIOUS INSPECTION NOTES 11/27/23: Previously listed deficiency not resolved. 11/27/23: Previously listed deficiency not resolved. Contractor stated that they will be doing step flashing as opposed to 5" x 5" continuous flashing. A revision showing this detail will need to be submitted to show details for step flashing as required. 11/22/2023 - PREVIOUS INSPECTION NOTES 11/22/23: Inspection stopped! Not Complete. * Missing all 5" x 5" flashing. 11/3/2023 - PREVIOUS INSPECTION NOTES Roof sheating at truss F5, right side garage not nailed. First sheet at the eave.
ROOF VALLEY & METAL 11/22/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/22/23: Inspection stopped! Not Complete. * Missing all 5" x 5" flashing. 11/3/2023 - PREVIOUS INSPECTION NOTES Roof sheating at truss F5, right side garage not nailed. First sheet at the eave.
ROOF VALLEY & METAL 11/03/2023 Disapproved - NO FEE JWALKER
Note: Roof sheating at truss F5, right side garage not nailed. First sheet at the eave.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/03/2023 Disapproved -FEE REQUIRED JWALKER
Note: 11/3/23 1. Truss plates or moisture barrier not installed where trusses land on CMU walls at multiple trusses throughout the building. 2. 2 over framing Ridge beams are to be support to create a continous load path. 3. Trusses B1, E5, CJ10, and EH5 are missing hold down anchors. 4. Trusses C1,2,3, and 4 at the front entry anchors require minimum of 9 fasteners. 5. The kneewall and the eave over framing at the front entry missing support blocking between trusses below and anchors / hold down straps. 6. Garage bearing wall 4x4 post and ABU44 anchor not installed. 7. Rear bearing wall between bed 3 and 4 not construted. 4x4 post, header, anchor bolts etc. 8. Rear porch 2x12 beam at the left side is supported on P.t. 2X6 Please porvide detail for this area. number of 2x required , anchoring to CMU and truss above. 9. NSPR blocking used for roof decking is to be SYP. remove at ares where roof decking edges are supported. Other areas can remain. Truss Engineering passed. Down cells passed. 11/1/2023 - PREVIOUS INSPECTION NOTES not ready for inspection, Missing 4x4 Post at detail-E Missing header at detail-D Missing MTS 18s Missing HTS 20s (all per plans and details) Inspection Stopped, nothing further looked at
WALL SHEATHING 11/01/2023 APPROVED LMILLER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/01/2023 Disapproved - NO FEE LMILLER
Note: not ready for inspection, Missing 4x4 Post at detail-E Missing header at detail-D Missing MTS 18s Missing HTS 20s (all per plans and details) Inspection Stopped, nothing further looked at
ROOF SHEATHING 10/20/2023 APPROVED RSIMS
Note: Inspector Notes from Inspection 2340 10/4/23: Please provide dumpster on site & clean up piles of trash/debris before next inspection.
ELECTRIC TEMP POLE 10/18/2023 APPROVED - AS NOTED BTAYLOR
Note: 10-18-23 1. Emailed FPL at 11:30.
TIE BEAM / LINTEL 10/04/2023 APPROVED - AS NOTED RSIMS
Note: 10/4/23: Please provide dumpster on site & clean up piles of trash/debris before next inspection.
FOUND SURVEY APPROVED (OFFICE) 09/18/2023 APPROVED TBAKER
MONOLITHIC SLAB 09/01/2023 APPROVED RSIMS
Note: 9/1/23: At time of inspection site was plan/code compliant.
PLUMBING 1ST ROUGH UNDERGROUND 08/23/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 08/23/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 08/04/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 11/29/2023 12/01/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 11/21/2023 11/27/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 11/14/2023 11/20/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Layout Needs to be digitally signed, sealed and verfiable per F.S.471.025
ENGIN1 COMPLETE 09/18/2023 09/18/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 06/09/2023 06/09/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/05/2023 06/05/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 06/05/2023 06/05/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 06/05/2023 06/05/2023
Note: Released By: JPI
ZON COMPLETE 05/23/2023 05/24/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD HOLD 05/23/2023 05/30/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a shop drawing approval stamp. For ease of review, please label this file Truss Summary- Profiles or Truss Calculations or of a similar nomenclature. 107.3.5
ENGIN1 COMPLETE 05/23/2023 05/24/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 05/23/2023 05/25/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
SW1 HOLD 05/23/2023 05/31/2023
Note: Held By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM SITE PLAN IS FOR A POOL PERMIT IS FOR BUILDING RESIDENTIAL
SWALE COMPLETE 05/18/2023 07/06/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 05/17/2023 05/20/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a shop drawing approval stamp. For ease of review, please label this file Truss Summary- Profiles or Truss Calculations or of a similar nomenclature. 107.3.5
CUSVC COMPLETE 05/17/2023 05/19/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 05/17/2023 05/22/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/17/2023 05/18/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 05/17/2023 05/18/2023
LOCATE COMPLETE 05/17/2023 05/19/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 05/17/2023 05/19/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 05/17/2023 05/23/2023
Note: Released By: FRANK SLADISH - - FSLADISH@PALMCOASTGOV.COM
ZON HOLD 05/17/2023 05/18/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Plans are for garage right, landscape and site are for garage left. please correct whichever is wrong. Must have a minimum total of 16 - 3 gallon foundation plantings with a minimum of eight in the front and four along each side wrapping corners
BADMIN COMPLETE 05/17/2023 05/22/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 04/10/2024
REINSPECTION RESIDENTIAL ¤40.00 04/10/2024
REINSPECTION RESIDENTIAL ¤40.00 04/10/2024
REINSPECTION RESIDENTIAL ¤40.00 04/10/2024
REINSPECTION RESIDENTIAL ¤40.00 04/10/2024
REINSPECTION RESIDENTIAL ¤40.00 04/10/2024
CONNECTION FEES ¤1,166.26 06/09/2023
FIRE IMPACT FEE ADMIN ¤12.62 06/09/2023
FIRE IMPACT FEE ADMIN (¤12.62) 06/09/2023
FC IMPACT FEE EMS ¤62.00 06/09/2023
IMPACT FEE FIRE ¤420.52 06/09/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/09/2023
FC IMPACT FEE LIBRARY ¤268.00 06/09/2023
IMPACT FEE PARKS ¤1,769.15 06/09/2023
IMPACT FEE SCHOOL ¤5,450.00 06/09/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 06/09/2023
WATER -IRRIGATION INSPECTION ¤25.00 06/09/2023
PARKS IMPACT FEE ADMIN ¤53.07 06/09/2023
PARKS IMPACT FEE ADMIN (¤53.07) 06/09/2023
SURCHARGE FS 533.721 ¤6.15 06/09/2023
SURCHARGE - FS 468.631 ¤9.23 06/09/2023
SW ENG - FOUNDATION SURVEY ¤20.00 06/09/2023
SW ENG INSPECTION 80 ¤80.00 06/09/2023
SW ENG PRE APRON ¤30.00 06/09/2023
SW ENG - REVIEW 20 ¤20.00 06/09/2023
SW ENG RES REVIEW 200 ¤200.00 06/09/2023
TRANS IMPACT FEE ADMIN ¤54.36 06/09/2023
TRANS IMPACT FEE ADMIN (¤54.36) 06/09/2023
SEWER CREDIT (¤850.00) 06/09/2023
SEWER INSPECTION ¤25.00 06/09/2023
SEWER CAPITAL FACILITY ¤5,344.82 06/09/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 06/09/2023
SITE PLAN 30 ¤30.00 06/09/2023
WATER- TURN ON ¤25.00 06/09/2023
ADJUSTMENT 50% (¤615.10) 06/09/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/09/2023
INSPECTION - RESIDENTIAL ¤935.00 06/09/2023
PLAN REVIEW - RESIDENTIAL ¤265.20 06/09/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,902.61