I want to search for...
Permit #2023051194
Permit Details
Status: COED
| Parcel Id: 07-11-31-7060-00080-0010 |
| CONDITIONED SPACE: 1298 sqft |
| CONDITIONED SPACE: 1298 sqft |
| GARAGE: 262 sqft |
| GARAGE: 262 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| OPENED PORCH (WITH ROOF) : 50 sqft |
| OPENED PORCH (WITH ROOF) : 27 sqft |
| OPENED PORCH (WITH ROOF) : 27 sqft |
| Total Square Footage: 3274 sqft |
| Block: 00080 |
| Subdivision: 2200 - SECTION 60-SEMINOLE PARK |
| Job Phone: 863-647-5815 |
| Location Address: 44 SLUMBER PATH |
| Type: DU - DUPLEX |
| Issue Date: 06/08/2023 |
| NOC: RECORDED |
| Applicant name: MARK ALLAN HULBERT |
| Owner: KENNEDY TERRY & JOY H&W |
|
Address 71 DEL PALMA DRIVE PALM COAST, FL 32137 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: DUPLEX - OPPORTUNITY MODEL |
| Type: CN |
| Original Permit #: 2023031577 |
Contractor
HULBERT HOMES INC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 6254 LAKELAND, FL 33813 |
CRC1331304 (Exp: 08/31/2026) | 863-647-5815 |
Sub Contractors
MOISES MERINO DIAZ
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3104 ORANOLE ROAD ORLANDO, FL 32810 |
CAC1820980 (Exp: 08/31/2026) | 407-225-3149 |
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
ANTONIO VINCENZO DAHM
| Status | Location Address | State License Number | Phone |
| ACTIVE |
10 RYBAR LANE PALM COAST, FL 32164 |
CFC1429951 (Exp: 08/31/2026) | 386-237-5692 |
JOSEPH C WRIGHT
| Status | Location Address | Mailing Address | State License Number | Phone | Fax |
| ACTIVE |
15 HARGROVE LANE PALM COAST, FL 32137 |
UNIT 3 D PALM COAST, FL 32137 |
EC13003278 (Exp: 08/31/2026) | 386-447-9644 | 386-447-9633 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 03/13/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: YOU NEED TO PASS THE FINAL SURVEY AND THE FIELD SURVEY BEFORE THIS INSPECTION. ------------------------------------------------------------------------------------ 3/11/2024 11:14:40 AM- PREVIOUS INSPECTION NOTES | |||
| ROW - FINAL APRON (AFTER POUR) | 03/13/2024 | APPROVED | GBERTOLA |
| Note: CORRECTION WERE MADE AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 3/13/2024 - PREVIOUS INSPECTION NOTES YOU NEED TO PASS THE FINAL SURVEY AND THE FIELD SURVEY BEFORE THIS INSPECTION. ------------------------------------------------------------------------------------ 3/11/2024 11:14:40 AM- PREVIOUS INSPECTION NOTES | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/13/2024 | APPROVED | GBERTOLA |
| Note: CORRECTION WERE MADE AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 3/12/2024 - PREVIOUS INSPECTION NOTES 1) THE FINAL SURVEY STATES THAT YOU DO NOT HAVE POSITIVE FALL TO THE ROADSIDE SWALE. 2) THE FINAL SURVEY STATES THAT ALL THE WATER IN THE BACK IS FLOWING TO THE BACK ROAD SITE PLAN STATES YOU HAVE A SWALE BEFORE THE PROPERTY LINE AND WATER RUNS TO THE LEFT SIDE ROADSIDE SWALE. 3) NEED TO HAVE ELEVATIONS ALONG THE BACK RIGHT PROPERTY LINE NEED TO BE EVERY 20' ON THE ROPERTY LINE. ------------------------------------------------------------------- 2/23/2024 - PREVIOUS INSPECTION NOTES 2/23/24 WE NEED ELEVATION SHOTS ON THE REAR PROPERTY LINE TO THE RIGHT CORNER. ON THE RIGHT SIDE PROPERTY LINE YOU ARE SHOWING 26.2 TO 26.3 TO 26.5 UPHILL TO FLAT 26.5 FOR 60' 26.6 AT THE FRONT RIGHT CORNER UPHILL AT THE FRONT. YOU MUST HAVE POSITIVE REAR TO FRONT DRAINAGE FLOW OF MINIMUM .10 EVERY 20' ALONG THE PROPERTY LINE. Lot must drain. Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. Elevations every 20 ft. on the property line Sec 300.01D1 Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/13/2024 | APPROVED | GBERTOLA |
| Note: CORRECTION WERE MADE AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 2/29/24=MEETING WITH THE BUILDER AND THEY NEED TO MAKE A SWALE ON THE RIGHT SIDE FACING THE HOUSE MOVING THE WATER TO THE FRONT SWALE.PER GBERTOLA. 2/14/2024 - PREVIOUS INSPECTION NOTES 2/14/24 YOU MUST SUBMIT AND PASS A FINAL SURVEY INSPECTION BEFORE A FIELD SURVEY INSPECTION CAN BE COMPLETED. PLEASE SUBMIT YOUR FINAL SURVEY FOR AN INSPECTION REVIEW. NO FEE. | |||
| ROW - STORMWATER FINAL | 03/13/2024 | APPROVED | GBERTOLA |
| Note: CORRECTION WERE MADE AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/12/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) THE FINAL SURVEY STATES THAT YOU DO NOT HAVE POSITIVE FALL TO THE ROADSIDE SWALE. 2) THE FINAL SURVEY STATES THAT ALL THE WATER IN THE BACK IS FLOWING TO THE BACK ROAD SITE PLAN STATES YOU HAVE A SWALE BEFORE THE PROPERTY LINE AND WATER RUNS TO THE LEFT SIDE ROADSIDE SWALE. 3) NEED TO HAVE ELEVATIONS ALONG THE BACK RIGHT PROPERTY LINE NEED TO BE EVERY 20' ON THE ROPERTY LINE. ------------------------------------------------------------------- 2/23/2024 - PREVIOUS INSPECTION NOTES 2/23/24 WE NEED ELEVATION SHOTS ON THE REAR PROPERTY LINE TO THE RIGHT CORNER. ON THE RIGHT SIDE PROPERTY LINE YOU ARE SHOWING 26.2 TO 26.3 TO 26.5 UPHILL TO FLAT 26.5 FOR 60' 26.6 AT THE FRONT RIGHT CORNER UPHILL AT THE FRONT. YOU MUST HAVE POSITIVE REAR TO FRONT DRAINAGE FLOW OF MINIMUM .10 EVERY 20' ALONG THE PROPERTY LINE. Lot must drain. Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. Elevations every 20 ft. on the property line Sec 300.01D1 Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. | |||
| ROW - FINAL APRON (AFTER POUR) | 03/12/2024 | CANCELLED BY APPLICANT | BBEMBRY |
| BLD - BUILDING FINAL | 03/12/2024 | FINAL APPROVED | BTAYLOR |
| Note: 3/7/2024 - PREVIOUS INSPECTION NOTES 3-7-24 1. Unit A no power in living room. 2. Energy cals do not match either unit. 3. Hole in attic in foam needs to be replaced and fire proofed. | |||
| BLD - BUILDING FINAL | 03/07/2024 | Disapproved - NO FEE | BTAYLOR |
| Note: 3-7-24 1. Unit A no power in living room. 2. Energy cals do not match either unit. 3. Hole in attic in foam needs to be replaced and fire proofed. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/23/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 2/23/24 WE NEED ELEVATION SHOTS ON THE REAR PROPERTY LINE TO THE RIGHT CORNER. ON THE RIGHT SIDE PROPERTY LINE YOU ARE SHOWING 26.2 TO 26.3 TO 26.5 UPHILL TO FLAT 26.5 FOR 60' 26.6 AT THE FRONT RIGHT CORNER UPHILL AT THE FRONT. YOU MUST HAVE POSITIVE REAR TO FRONT DRAINAGE FLOW OF MINIMUM .10 EVERY 20' ALONG THE PROPERTY LINE. Lot must drain. Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). Unless specifically stated the subject lot must drain from back to front Rear Yard Drainage Sec 300.01(4,5,6) Sec 300.01(4,5,6) The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side.Positive fall is considered to be 0.10 feet in 20 feet.The minimum fall from the rear property line to the front is 0.50 feet. Elevations every 20 ft. on the property line Sec 300.01D1 Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/14/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 2/14/24 YOU MUST SUBMIT AND PASS A FINAL SURVEY INSPECTION BEFORE A FIELD SURVEY INSPECTION CAN BE COMPLETED. PLEASE SUBMIT YOUR FINAL SURVEY FOR AN INSPECTION REVIEW. NO FEE. | |||
| U-CROSS CONNECTION | 02/14/2024 | APPROVED - AS NOTED | JHARDING |
| Note: No irrigation, no cross connections. | |||
| U - SEWER TIE IN | 01/23/2024 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 01/23/2024 | APPROVED | MGIBSON |
| Note: 8/14/2023 - PREVIOUS INSPECTION NOTES SEWER NOT RAN YET TO PEP TANK | |||
| ELECTRIC - EARLY POWER | 01/18/2024 | APPROVED - AS NOTED | BTAYLOR |
| Note: Inspector Notes from Inspection 2170 6-30-23 1. Emailed FPL at 8:32. 1-18-24 1. Emailed FPL at 11:57. | |||
| ROW- PRE-APRON (PRE-POUR) | 12/22/2023 | Disapproved - NO FEE | RGROSS |
| Note: There are 7 discs in the road in the vacinity of the BM indicated on the site and swale plans. Please clearly identify the correct one. | |||
| ROW- PRE-APRON (PRE-POUR) | 12/22/2023 | APPROVED | RGROSS |
| Note: Doubled back as a courtesy because of the holiday and reinspected the same day. NID identified as the RED one. 12/22/2023 - PREVIOUS INSPECTION NOTES There are 7 discs in the road in the vacinity of the BM indicated on the site and swale plans. Please clearly identify the correct one. | |||
| PEP TANK INSTALLATION REQUEST | 11/30/2023 | APPROVED | CBOWERMASTER |
| LATH/BRICK/ WATER BARRIER | 11/07/2023 | APPROVED | BTAYLOR |
| FIREWALL DRYWALL NAILING | 10/02/2023 | APPROVED | BTAYLOR |
| INSULATION | 09/22/2023 | APPROVED | BTAYLOR |
| Note: 9/15/2023 - PREVIOUS INSPECTION NOTES 9-15-23 1. Missing SCREWS in header.Engineer stated that SCREWS were to be used not NAILS. Do not call this back in till SCREWS have been installed..... | |||
| INSULATION | 09/15/2023 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: 9-15-23 1. Missing SCREWS in header.Engineer stated that SCREWS were to be used not NAILS. Do not call this back in till SCREWS have been installed..... | |||
| ALL ROUGH | 09/05/2023 | APPROVED | BTAYLOR |
| WALL SHEATHING | 09/01/2023 | APPROVED | BTAYLOR |
| Note: Inspector Notes from Inspection 2460 8/24/2023 - PREVIOUS INSPECTION NOTES 8/21/2023 - PREVIOUS INSPECTION NOTES 8/17/2023 - PREVIOUS INSPECTION NOTES 8-17-23 1. Truss to bearing wall not per detail. 2. No engineering packet. 3. Bearing wall not built per detail. 8-21-23 1. Truss to bearing wall not per detail. 2. Bearing wall not built per detail. 8-24-23 1.Bearing wall not built per detail. 8-31-23 1. Header in garage needs straps. 2. Rear door missing jack stud. 3. Over framing not strapped at ridge. | |||
| ROOF VALLEY & METAL | 09/01/2023 | APPROVED | BTAYLOR |
| Note: Inspector Notes from Inspection 2460 8/24/2023 - PREVIOUS INSPECTION NOTES 8/21/2023 - PREVIOUS INSPECTION NOTES 8/17/2023 - PREVIOUS INSPECTION NOTES 8-17-23 1. Truss to bearing wall not per detail. 2. No engineering packet. 3. Bearing wall not built per detail. 8-21-23 1. Truss to bearing wall not per detail. 2. Bearing wall not built per detail. 8-24-23 1.Bearing wall not built per detail. 8-31-23 1. Header in garage needs straps. 2. Rear door missing jack stud. 3. Over framing not strapped at ridge. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/31/2023 | APPROVED - AS NOTED | BTAYLOR |
| Note: 8/24/2023 - PREVIOUS INSPECTION NOTES 8/21/2023 - PREVIOUS INSPECTION NOTES 8/17/2023 - PREVIOUS INSPECTION NOTES 8-17-23 1. Truss to bearing wall not per detail. 2. No engineering packet. 3. Bearing wall not built per detail. 8-21-23 1. Truss to bearing wall not per detail. 2. Bearing wall not built per detail. 8-24-23 1.Bearing wall not built per detail. 8-31-23 1. Header in garage needs straps. 2. Rear door missing jack stud. 3. Over framing not strapped at ridge. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/24/2023 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: 8/21/2023 - PREVIOUS INSPECTION NOTES 8/17/2023 - PREVIOUS INSPECTION NOTES 8-17-23 1. Truss to bearing wall not per detail. 2. No engineering packet. 3. Bearing wall not built per detail. 8-21-23 1. Truss to bearing wall not per detail. 2. Bearing wall not built per detail. 8-24-23 1.Bearing wall not built per detail. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/21/2023 | Disapproved -FEE REQUIRED | BTAYLOR |
| Note: 8/17/2023 - PREVIOUS INSPECTION NOTES 8-17-23 1. Truss to bearing wall not per detail. 2. No engineering packet. 3. Bearing wall not built per detail. 8-21-23 1. Truss to bearing wall not per detail. 2. Bearing wall not built per detail. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/17/2023 | Disapproved - NO FEE | BTAYLOR |
| Note: 8-17-23 1. Truss to bearing wall not per detail. 2. No engineering packet. 3. Bearing wall not built per detail. | |||
| GRAVITY SEWER TEST | 08/14/2023 | Disapproved -FEE REQUIRED | MGIBSON |
| Note: SEWER NOT RAN YET TO PEP TANK | |||
| FOUND SURVEY APPROVED (OFFICE) | 08/14/2023 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 07/05/2023 | APPROVED | BTAYLOR |
| Note: 6/30/2023 - PREVIOUS INSPECTION NOTES 6-30-23 1. Steel missing in headers. | |||
| ELECTRIC TEMP POLE | 06/30/2023 | APPROVED - AS NOTED | BTAYLOR |
| Note: 6-30-23 1. Emailed FPL at 8:32. | |||
| TIE BEAM / LINTEL | 06/30/2023 | Disapproved - NO FEE | BTAYLOR |
| Note: 6-30-23 1. Steel missing in headers. | |||
| MONOLITHIC SLAB | 06/20/2023 | APPROVED | BTAYLOR |
| PLUMBING 1ST ROUGH UNDERGROUND | 06/14/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 06/14/2023 | APPROVED | CSTONE |
Review History
| Department | Status | Date In | Date Out |
| MECH | HOLD | 03/11/2024 | 03/11/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Upload revised heatloads | |||
| MECH | COMPLETE | 03/11/2024 | 03/11/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 03/07/2024 | 03/11/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM This is a masterfile. Upload heatload only for side A and B | |||
| BLD | COMPLETE | 01/26/2024 | 01/26/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 01/26/2024 | 01/26/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/26/2024 | 01/26/2024 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/28/2023 | 09/29/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/28/2023 | 09/29/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/28/2023 | 09/29/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/14/2023 | 08/14/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/14/2023 | 08/14/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/02/2023 | 06/05/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 05/31/2023 | 06/01/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide heatload with side A and B listed on heatload. Provide correct heatloads not double of one side. 2. Provide duct layout for both sides with correct orientation | |||
| ZON | COMPLETE | 05/31/2023 | 05/31/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 05/23/2023 | 07/12/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 05/22/2023 | 05/25/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 05/22/2023 | 05/24/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 05/22/2023 | 05/23/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 05/22/2023 | 05/23/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 05/22/2023 | 05/23/2023 |
| LOCATE | COMPLETE | 05/22/2023 | 05/25/2023 |
| Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 05/22/2023 | 05/23/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide only heatload not energy calc. 2. Provide duct layout | |||
| SW1 | COMPLETE | 05/22/2023 | 05/30/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 05/22/2023 | 05/24/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM All windows and doors facing right of way must have banding. This house has a street on the left side and rear. | |||
| BADMIN | INFORMATION | 05/22/2023 | 05/22/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The NOC was rejected, the wrong county is referenced (Palm Beach) For future, since you dont have right, left, A, B, C, etc. you do not need to 'fill in' that information on the site specific sheet, you can write N/A for those That would be if you had options submitted for the master file, and then you would identify which option you are using. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 03/13/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 03/13/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/13/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/13/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/13/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/13/2024 |
| CONNECTION FEES | ¤2,332.52 | 06/08/2023 |
| WATER- TURN ON | ¤50.00 | 06/08/2023 |
| ADJUSTMENT 50% | (¤448.13) | 06/08/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/08/2023 |
| INSPECTION - RESIDENTIAL | ¤866.25 | 06/08/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤126.00 | 06/08/2023 |
| FIRE IMPACT FEE ADMIN | ¤25.23 | 06/08/2023 |
| FIRE IMPACT FEE ADMIN | (¤25.23) | 06/08/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 06/08/2023 |
| IMPACT FEE FIRE | ¤841.04 | 06/08/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 06/08/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 06/08/2023 |
| IMPACT FEE PARKS | ¤3,538.30 | 06/08/2023 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 06/08/2023 |
| IMPACT FEE TRANSPORTATION | ¤2,812.00 | 06/08/2023 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 06/08/2023 |
| PARKS IMPACT FEE ADMIN | ¤106.15 | 06/08/2023 |
| PARKS IMPACT FEE ADMIN | (¤106.15) | 06/08/2023 |
| SURCHARGE FS 533.721 | ¤5.74 | 06/08/2023 |
| SURCHARGE - FS 468.631 | ¤8.61 | 06/08/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 06/08/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 06/08/2023 |
| SW ENG PRE APRON | ¤30.00 | 06/08/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/08/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/08/2023 |
| TRANS IMPACT FEE ADMIN | ¤84.36 | 06/08/2023 |
| TRANS IMPACT FEE ADMIN | (¤84.36) | 06/08/2023 |
| SEWER CREDIT | (¤2,932.00) | 06/08/2023 |
| SEWER INSPECTION | ¤25.00 | 06/08/2023 |
| SEWER CAPITAL FACILITY | ¤10,689.64 | 06/08/2023 |
| WATER CAPITAL FACILITY FEE | ¤7,847.76 | 06/08/2023 |
| SITE PLAN 30 | ¤30.00 | 06/08/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤37,883.23 |