I want to search for...
Permit #2023051245
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7025-00680-0020 |
| Block: 00680 |
| Subdivision: 2189 - SECTION 25-PINE GROVE |
| Job Phone: 386-931-1183 |
| Location Address: 19 PATRIC DR |
| Type: PO - POOL |
| Issue Date: 06/20/2023 |
| NOC: RECORDED |
| Applicant name: JASON EUGENE SLESSER |
| Owner: CATES ALICE DEANNA |
|
Address P.O. BOX 353502 PALM COAST, FL 32135 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤42,590.00 |
| Job Description: POOL AND SCREEN |
| Type: CN |
Contractor
SLESSER CUSTOM POOLS AND SPAS, INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P. O. Box 2595 Bunnell, 32110 |
CPC1456546 (Exp: 08/31/2026) | 386-931-1183 |
Sub Contractors
RICHARD SWAN TOWNSEND II
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3111 OPPORTUNITY CT SUITE D PORT ORANGE, FL 32129 |
CGC1515792 (Exp: 08/31/2026) | 386-756-8770 |
CHRISTOPHER I HALL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 2413 Bunnell, FL 32110 |
EC13002161 (Exp: 08/31/2028) | (386) 437-2966 | 386-437-5042 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 10/10/2023 | FINAL APPROVED | MKRASKI |
| U -UTILITY RESIDENTIAL FINAL | 10/05/2023 | FINAL APPROVED | LFITZGERALD |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 10/04/2023 | APPROVED - AS NOTED | PFLANAGAN |
| Note: THE FINAL SURVEY DOESN'T NOT MATCH WHAT THE SITE PLAN SHOWS. SITE PLAN STATES THE THEY WERE GOING TO PUT ALL WATER FROM BACK TO FRONT BUT SURVEY SHOWS WATER GOING TO THE RESERVE PARCEL BEHIND TJE LOT. FIELD SHOWS WHAT THE FINAL SURVEY SHOWS. PER ROBERT THAT IF THE DRAINAGE IS WORKING PASSING | |||
| ROW - FINAL INSPECTION | 10/04/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ------------------------------------------------------------------- Inspector Notes from Inspection 9463 THE FINAL SURVEY DOESN'T NOT MATCH WHAT THE SITE PLAN SHOWS. SITE PLAN STATES THE THEY WERE GOING TO PUT ALL WATER FROM BACK TO FRONT BUT SURVEY SHOWS WATER GOING TO THE RESERVE PARCEL BEHIND TJE LOT. FIELD SHOWS WHAT THE FINAL SURVEY SHOWS. PER ROBERT THAT IF THE DRAINAGE IS WORKING PASSING | |||
| ELECTRIC AND ALARM | 08/21/2023 | APPROVED | KSANDOE |
| POOL DECK | 07/21/2023 | APPROVED | KSANDOE |
| STEEL AND GROUND | 06/23/2023 | APPROVED | KSANDOE |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 10/03/2023 | 10/03/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM If this is a final survey, please upload under the document type 'final survey'. If it is a revision , please identify what the revision is on the revision sheet when the box pops up to enter a description and review department. | |||
| BADMIN | INFORMATION | 10/03/2023 | 10/03/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM If this is a final survey, please upload under the document type 'final survey'. If it is a revision , please identify what the revision is on the revision sheet when the box pops up to enter a description and review department. | |||
| BLD | COMPLETE | 06/15/2023 | 06/16/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/06/2023 | 06/06/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Provide note on plan that any glazing 60 inches or less from water’s edge measured in a straight line and with bottom exposed edge of glazing less than 60 inches vertically above any standing or walking surface will be tempered glass before pool final inspection per R308.4.5. 2nd REQUEST | |||
| SW1 | COMPLETE | 06/06/2023 | 06/14/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 06/05/2023 | 06/05/2023 |
| Note: Held By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM flow arrows for the drainage pattern must be clearly depicted on the approved site plan. | |||
| ZON | COMPLETE | 05/23/2023 | 05/24/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| BLD | HOLD | 05/23/2023 | 05/24/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Provide note on plan that any glazing 60 inches or less from water’s edge measured in a straight line and with bottom exposed edge of glazing less than 60 inches vertically above any standing or walking surface will be tempered glass before pool final inspection per R308.4.5. | |||
| ELEC | COMPLETE | 05/23/2023 | 05/24/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 05/23/2023 | 05/24/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤127.50) | 06/20/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/20/2023 |
| INSPECTION- POOL | ¤160.00 | 06/20/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 06/20/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 06/20/2023 |
| SURCHARGE - FS 468.631 | ¤2.00 | 06/20/2023 |
| SW ENG INSPECTION 40 | ¤40.00 | 06/20/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/20/2023 |
| SITE PLAN 30 | ¤30.00 | 06/20/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤221.50 |