I want to search for...

Permit #2023051307

Permit Details

Status: COED

Parcel Id: 07-11-31-7021-00010-0340
CONDITIONED SPACE: 1298 sqft
CONDITIONED SPACE: 1298 sqft
GARAGE: 262 sqft
GARAGE: 262 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
OPENED PORCH (WITH ROOF) : 50 sqft
OPENED PORCH (WITH ROOF) : 27 sqft
OPENED PORCH (WITH ROOF) : 27 sqft
Total Square Footage: 3274 sqft
Block: 00010
Subdivision: 2186 - SECTION 21-WYNNFIELD
Job Phone: 863-647-5815
Location Address: 83 WELLWOOD LN
Type: DU - DUPLEX
Issue Date: 08/29/2023
NOC: RECORDED
Applicant name: MARK ALLAN HULBERT
Owner: SU CASA PROPERTY MANAGEMENT OF FLORIDA LLC

Address

5116 S LAKELAND DRIVE

LAKELAND, FL 33813

Lot: 0340
Contracted Stated Job Value: ¤300,000.00
Job Description: DUPLEX - THE OPPORTUNITY MODEL
Type: CN
Original Permit #: 2023031577

Contractor

HULBERT HOMES INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 6254

LAKELAND, FL 33813

CRC1331304 (Exp: 08/31/2026) 863-647-5815

Sub Contractors

MOISES MERINO DIAZ
Status Location Address State License Number Phone
ACTIVE

3104 ORANOLE ROAD

ORLANDO, FL 32810

CAC1820980 (Exp: 08/31/2026) 407-225-3149
DUSTIN L ESTEP
Status Location Address State License Number Phone Fax
ACTIVE

2041 N HIAWASSEE RD

APOPKA, FL 32703

CCC1330971 (Exp: 08/31/2026) 407-702-0206 352-988-6629
ANTONIO VINCENZO DAHM
Status Location Address State License Number Phone
ACTIVE

10 RYBAR LANE

PALM COAST, FL 32164

CFC1429951 (Exp: 08/31/2026) 386-237-5692
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/14/2024 FINAL APPROVED MKRASKI
BLD - BUILDING FINAL 05/08/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 5/8/24 1. Front doors do not stay closed 2. Insulation foam in attic space must be painted with fire retardant (AHU and plywood in attic) 3. Island power is required to have outlets at each end per NEC 210.50 C 2 4. Laundry circuits must just serve laundry room NEC 210.11 C 2 5. Dinning area cicuit not labled in panel 5/2/2024 - PREVIOUS INSPECTION NOTES 5/2/24 1. Temp power pole must be removed before final 2. AHU's (both units) have undersized breaker installed 3. Extra building materials need to be removed before final 4. 2'' square washer are required for garage door bucks per plans (removed during door installion it appears) Stopped inspection in garage 4/26/2024 - PREVIOUS INSPECTION NOTES 1. Line set chase needs to be sealed 2. Backflow preventer on outside hose bibs need to have tamper proof screw broken off 3. Soffit penitrations above electrical service need to be properly sealed 4. Porta john needs to be removed before final 5. All garage penitrations need to be sealed Stopped inspection, Only walked outside and in garage, did not check AHU in attic
BLD - BUILDING FINAL 05/02/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 5/2/24 1. Temp power pole must be removed before final 2. AHU's (both units) have undersized breaker installed 3. Extra building materials need to be removed before final 4. 2'' square washer are required for garage door bucks per plans (removed during door installion it appears) Stopped inspection in garage 4/26/2024 - PREVIOUS INSPECTION NOTES 1. Line set chase needs to be sealed 2. Backflow preventer on outside hose bibs need to have tamper proof screw broken off 3. Soffit penitrations above electrical service need to be properly sealed 4. Porta john needs to be removed before final 5. All garage penitrations need to be sealed Stopped inspection, Only walked outside and in garage, did not check AHU in attic
BLD - BUILDING FINAL 04/26/2024 Disapproved - NO FEE MKRASKI
Note: 1. Line set chase needs to be sealed 2. Backflow preventer on outside hose bibs need to have tamper proof screw broken off 3. Soffit penitrations above electrical service need to be properly sealed 4. Porta john needs to be removed before final 5. All garage penitrations need to be sealed Stopped inspection, Only walked outside and in garage, did not check AHU in attic
U-CROSS CONNECTION 04/23/2024 FINAL APPROVED LFITZGERALD
Note: has potable irrigation with PVB AT BOTH UNITS-NO CROSS CNNECTION
ROW- PROJECT STATUS 04/19/2024 APPROVED GBERTOLA
Note: MEETING WITH THE BUILDER
ROW - FINAL APRON (AFTER POUR) 04/19/2024 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/19/2024 APPROVED GBERTOLA
Note: 5/19/2024= COMPARING THE FINAL SURVEY AND SWALE PLAN, THE DIFFERENCE IS 2 HUNDRED. STILL INSIDE THE TOLERANCE. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 4/17/2024 - PREVIOUS INSPECTION NOTES 1) THE CULVERT PIPE IS OUT OF TOLERANCE WITH THE SWALE PLAN DETAIL THAT WAS PROVIDED. 2) YOUR DRAINAGE OF THE LOT DOESN'T MATCH WITH THE LATEST SITE PLAN THAT WAS PROPOSED AND APPROVED. THE FINAL SURVEY SHOWS YOUR WATER FLOWING FROM BACK TO THE FRONT. BUT THE SITE PLAN SHOWS THE BACK YARD AT THE BACK CORNERS OF THE HOUSE WAS PROPOSED TO THE DRAIN TO THE DRAINAGE FEATURE IN THE BACK. 3) THE DRAINAGE ALONG THE SIDES OF THE HOUSE NEED TO HAVE POSITIVE FALL TO THE FRONT ROADSIDE SWALE.
ROW FIELD SURVEY /GRADING CERTIFICATION 04/19/2024 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW - STORMWATER FINAL 04/19/2024 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/17/2024 Disapproved - NO FEE PFLANAGAN
Note: 1) THE CULVERT PIPE IS OUT OF TOLERANCE WITH THE SWALE PLAN DETAIL THAT WAS PROVIDED. 2) YOUR DRAINAGE OF THE LOT DOESN'T MATCH WITH THE LATEST SITE PLAN THAT WAS PROPOSED AND APPROVED. THE FINAL SURVEY SHOWS YOUR WATER FLOWING FROM BACK TO THE FRONT. BUT THE SITE PLAN SHOWS THE BACK YARD AT THE BACK CORNERS OF THE HOUSE WAS PROPOSED TO THE DRAIN TO THE DRAINAGE FEATURE IN THE BACK. 3) THE DRAINAGE ALONG THE SIDES OF THE HOUSE NEED TO HAVE POSITIVE FALL TO THE FRONT ROADSIDE SWALE.
ELECTRIC - EARLY POWER 04/05/2024 APPROVED - AS NOTED KSANDOE
Note: Inspector Notes from Inspection 2170 Emailed FPL @ 1010. Release Power 12/20/2023 - PREVIOUS INSPECTION NOTES Emailed FPL @ 1118. Release Power Inspector Notes from Inspection 2170 Emailed FPL @ 1010. Release Power 12/20/2023 - PREVIOUS INSPECTION NOTES
ROW- PRE-APRON (PRE-POUR) 02/29/2024 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
U - SEWER TIE IN 02/27/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
GRAVITY SEWER TEST 02/27/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
FIREWALL FINAL 02/21/2024 APPROVED MKRASKI
FIREWALL FINAL 02/20/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 2/20/24 Ceiling is already hung, can not see if previous item has been repaired. 1/10/2024 - PREVIOUS INSPECTION NOTES PVC protecting Wires going through firewall not fire foamed..
INSULATION 02/09/2024 APPROVED RSIMS
Note: 2/7/2024 - PREVIOUS INSPECTION NOTES
INSULATION 02/07/2024 CANCELLED BY APPLICANT MKRASKI
FIREWALL DRYWALL NAILING 02/02/2024 APPROVED KSANDOE
Note: 1/31/2024 - PREVIOUS INSPECTION NOTES Smoke barrier needs to extend all the way to the facia through the soffits 1/25/2024 - PREVIOUS INSPECTION NOTES 1/24/2024 - PREVIOUS INSPECTION NOTES 1. Soffit is up and can not verify that smoke barrier extends to top of soffit 2. All seams and joints need to be sealed, (will not see again for final, plans call for 5/8''s type x on ceiling and firewall) 3. All conduits extending through smoke barrier must be sealed
ELECTRIC TEMP POLE 02/02/2024 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 1010. Release Power 12/20/2023 - PREVIOUS INSPECTION NOTES
FIREWALL DRYWALL NAILING 01/31/2024 Disapproved - NO FEE KSANDOE
Note: Smoke barrier needs to extend all the way to the facia through the soffits 1/25/2024 - PREVIOUS INSPECTION NOTES 1/24/2024 - PREVIOUS INSPECTION NOTES 1. Soffit is up and can not verify that smoke barrier extends to top of soffit 2. All seams and joints need to be sealed, (will not see again for final, plans call for 5/8''s type x on ceiling and firewall) 3. All conduits extending through smoke barrier must be sealed
FIREWALL DRYWALL NAILING 01/25/2024 CANCELLED BY APPLICANT MKRASKI
Note: 1/24/2024 - PREVIOUS INSPECTION NOTES 1. Soffit is up and can not verify that smoke barrier extends to top of soffit 2. All seams and joints need to be sealed, (will not see again for final, plans call for 5/8''s type x on ceiling and firewall) 3. All conduits extending through smoke barrier must be sealed
FIREWALL DRYWALL NAILING 01/24/2024 Disapproved - NO FEE MKRASKI
Note: 1. Soffit is up and can not verify that smoke barrier extends to top of soffit 2. All seams and joints need to be sealed, (will not see again for final, plans call for 5/8''s type x on ceiling and firewall) 3. All conduits extending through smoke barrier must be sealed
LATH/BRICK/ WATER BARRIER 01/24/2024 APPROVED MKRASKI
ALL ROUGH 01/10/2024 APPROVED - AS NOTED BTAYLOR
Note: 12/20/2023 - PREVIOUS INSPECTION NOTES 12/15/2023 - PREVIOUS INSPECTION NOTES 12/15/23: Need revision submitted to & Approved by the City for the different windows that are installed (41886) than what was originally submitted (17676-R2). Also, please provide installation instructions as this size window under the FPA number does not show on the DBPR approved documents. * Need Meter Panels labeled for A & B units. Unit A: 1). 5ft head pressure not holding. 2). Dryer exhaust needs to be properly sealed at roof sheathing. Unit B: 1). All windows are missing anchors at center locations. 1-10-24 1. Both units have holes in panel box that need to be filled. Plastic insert will not do. 2. Both units front and rear doors not installed. Check on insulation.
FIREWALL FINAL 01/10/2024 Disapproved - NO FEE FWILLIS
Note: PVC protecting Wires going through firewall not fire foamed..
ALL ROUGH 12/20/2023 CANCELLED BY APPLICANT MKRASKI
Note: 12/15/2023 - PREVIOUS INSPECTION NOTES 12/15/23: Need revision submitted to & Approved by the City for the different windows that are installed (41886) than what was originally submitted (17676-R2). Also, please provide installation instructions as this size window under the FPA number does not show on the DBPR approved documents. * Need Meter Panels labeled for A & B units. Unit A: 1). 5ft head pressure not holding. 2). Dryer exhaust needs to be properly sealed at roof sheathing. Unit B: 1). All windows are missing anchors at center locations.
ELECTRIC TEMP POLE 12/20/2023 CANCELLED BY APPLICANT MKRASKI
ALL ROUGH 12/15/2023 Disapproved - NO FEE RSIMS
Note: 12/15/23: Need revision submitted to & Approved by the City for the different windows that are installed (41886) than what was originally submitted (17676-R2). Also, please provide installation instructions as this size window under the FPA number does not show on the DBPR approved documents. * Need Meter Panels labeled for A & B units. Unit A: 1). 5ft head pressure not holding. 2). Dryer exhaust needs to be properly sealed at roof sheathing. Unit B: 1). All windows are missing anchors at center locations.
WALL SHEATHING 11/15/2023 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/15/2023 APPROVED FWILLIS
ROOF VALLEY & METAL 11/15/2023 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 11/14/2023 APPROVED TBAKER
TIE BEAM / LINTEL 10/18/2023 APPROVED RSIMS
Note: 10/17/2023 - PREVIOUS INSPECTION NOTES Contractor on site making repairs for missed dowels, stopped inspection not ready.
TIE BEAM / LINTEL 10/17/2023 Disapproved - NO FEE MKRASKI
Note: Contractor on site making repairs for missed dowels, stopped inspection not ready.
MONOLITHIC SLAB 10/03/2023 APPROVED MKRASKI
Note:
MONOLITHIC SLAB 10/02/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 10/2/23 1. No 50 lbs of pressure on supply lines 2. Missing 3 dowels marked on plans 3. Footings needs to be cleaned out where wash outs have occured 4. Form board need to be added or footing walls need to be backfilled to match details 9/29/2023 - PREVIOUS INSPECTION NOTES 9/28/2023 - PREVIOUS INSPECTION NOTES 9/28/23 1. No compaction test on site 2. No intent to treat paper work onsite Stopped inspection
MONOLITHIC SLAB 09/29/2023 CANCELLED BY APPLICANT MKRASKI
Note: 9/28/2023 - PREVIOUS INSPECTION NOTES 9/28/23 1. No compaction test on site 2. No intent to treat paper work onsite Stopped inspection
MONOLITHIC SLAB 09/28/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 9/28/23 1. No compaction test on site 2. No intent to treat paper work onsite Stopped inspection
MONOLITHIC SLAB 09/27/2023 CANCELLED BY APPLICANT FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 09/22/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 09/22/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 04/16/2024 04/17/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 02/21/2024 02/26/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/12/2023 11/14/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 11/12/2023 11/13/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/28/2023 09/29/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 09/28/2023 09/29/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 09/28/2023 09/29/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 08/14/2023 08/16/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLFM COMPLETE 08/14/2023 08/21/2023
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM According to the revised Survey submitted 8/14/23 and Site Plan submitted 8/21/23, the structure will not fall inside the SFHA. No elevation certificates will be required.
MECH HOLD 07/17/2023 07/18/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM This is a master filed home. Provide only heatload (Named Heatload) and Duct layout (Named duct layout) for both sides of duplex
PLFM HOLD 07/17/2023 08/01/2023
Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM Staff has not heard back from the survey company after the discussion about the flood zone line that took place on 7/21/23. Staff disagrees with the depicted location of the flood zone line, and instead believes it to be on the property. Per 10.02.07.B in the Land Development Code, the Base Flood Elevation must be established by an engineer and submitted to the City for review. Additional comments may apply when the analysis is submitted.
MECH HOLD 07/05/2023 07/06/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide heatload and duct layout for both sides of duplex. Provide correct garage orientation on duct layout and correct heatload for each side. Do not upload same doument for each side of duplex (Third Request)
PLFM HOLD 07/05/2023 07/10/2023
Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM Comment not addressed: both the Site Plan and Survey need to be revised. Revised survey was not provided. Per 10.02.07.B in the Land Development Code, the Base Flood Elevation must be established by an engineer and submitted to the City for review. Additional comments may apply when the analysis is submitted.
SW1 COMPLETE 07/05/2023 07/12/2023
Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/05/2023 07/05/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 07/05/2023 07/05/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM no zoning changes only for stw
SW1 HOLD 06/28/2023 06/28/2023
Note: Held By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM Refer to stormwater checklist to make the corrections needed to meet the city minimums stormwater requirements
ENGIN1 COMPLETE 06/20/2023 06/20/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
PLFM HOLD 06/20/2023 06/27/2023
Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM Comment not addressed: both the Site Plan and Survey need to be revised. Revised survey was not provided. Per 10.02.07.B in the Land Development Code, the Base Flood Elevation must be established by an engineer and submitted to the City for review. Additional comments may apply when the analysis is submitted.
MECH HOLD 06/20/2023 06/22/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide heatload and duct layout for both sides of duplex. (Second Request)
ZON COMPLETE 06/20/2023 06/20/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 06/05/2023 06/05/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
SWALE COMPLETE 05/25/2023 07/13/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
PLFM HOLD 05/25/2023 05/25/2023
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM There is an unnumbered A Zone on the property, both the Site Plan and Survey need to be revised as neither have this information. Per 10.02.07.B in the Land Development Code, the Base Flood Elevation must be established by an engineer and submitted to the City for review. Additional comments may apply when the analysis is submitted.
ENGIN1 HOLD 05/25/2023 05/25/2023
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Please provide slab elevations of 2 adjacent homes on survey.
ZON COMPLETE 05/24/2023 05/25/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 05/24/2023 05/26/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 05/24/2023 05/25/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 05/24/2023 05/30/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 05/24/2023 05/25/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 05/24/2023 05/26/2023
LOCATE COMPLETE 05/24/2023 05/26/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
MECH HOLD 05/24/2023 05/26/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide heatload and duct layout for both sides of duplex

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 05/15/2024
PLAN REVIEW - REVISION ¤32.50 05/15/2024
REINSPECTION RESIDENTIAL ¤40.00 05/15/2024
REINSPECTION RESIDENTIAL ¤40.00 05/15/2024
REINSPECTION RESIDENTIAL ¤40.00 05/15/2024
REINSPECTION RESIDENTIAL ¤40.00 05/15/2024
REINSPECTION RESIDENTIAL ¤40.00 05/15/2024
SW ENG REINSPECTION 20 ¤20.00 05/15/2024
SW ENG - REVIEW 20 ¤20.00 08/29/2023
SW ENG RES REVIEW 200 ¤200.00 08/29/2023
TRANS IMPACT FEE ADMIN ¤84.36 08/29/2023
TRANS IMPACT FEE ADMIN (¤84.36) 08/29/2023
SEWER INSPECTION ¤25.00 08/29/2023
SEWER CAPITAL FACILITY ¤10,689.64 08/29/2023
WATER CAPITAL FACILITY FEE ¤7,847.76 08/29/2023
SITE PLAN 30 ¤30.00 08/29/2023
CONNECTION FEES ¤2,332.52 08/29/2023
WATER- TURN ON ¤50.00 08/29/2023
ADJUSTMENT 50% (¤448.13) 08/29/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/29/2023
INSPECTION - RESIDENTIAL ¤866.25 08/29/2023
FIRE IMPACT FEE ADMIN ¤25.23 08/29/2023
FIRE IMPACT FEE ADMIN (¤25.23) 08/29/2023
FC IMPACT FEE EMS ¤62.00 08/29/2023
IMPACT FEE FIRE ¤841.04 08/29/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 08/29/2023
FC IMPACT FEE LIBRARY ¤268.00 08/29/2023
IMPACT FEE PARKS ¤3,538.30 08/29/2023
IMPACT FEE SCHOOL ¤10,900.00 08/29/2023
IMPACT FEE TRANSPORTATION ¤2,812.00 08/29/2023
WATER -IRRIGATION INSPECTION ¤50.00 08/29/2023
PARKS IMPACT FEE ADMIN ¤106.15 08/29/2023
PARKS IMPACT FEE ADMIN (¤106.15) 08/29/2023
SURCHARGE FS 533.721 ¤4.48 08/29/2023
SURCHARGE - FS 468.631 ¤6.72 08/29/2023
SW ENG - FOUNDATION SURVEY ¤20.00 08/29/2023
SW ENG INSPECTION 80 ¤80.00 08/29/2023
SW ENG PRE APRON ¤30.00 08/29/2023
Fees Total Due: ¤0.00 Total Paid: ¤40,746.08