I want to search for...
Permit #2023051560
Permit Details
Status: EXPIRED
| Parcel Id: 07-11-31-7029-00490-0010 |
| Block: 00490 |
| Subdivision: 2209 - SECTION 29-ROYAL PALMS |
| Job Phone: 904-885-0891 |
| Location Address: 28 RYKILL WAY |
| Type: EL - ELECTRICAL |
| Issue Date: 06/09/2023 |
| NOC: Unknown |
| Applicant name: DANIEL JOSEPH SCHWARZKOPF |
| Owner: COREY SHELDON & DENISE H&W |
|
Address 28 RYKILL WAY PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤1,200.00 |
| Job Description: Install Spa |
| Type: CN |
Contractor
ANCHOR ELECTRIC OF FLORIDA, INC.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4601 E MOODY BLVD D6 PALM COAST, FL 32164 |
EC13010351 (Exp: 08/31/2026) | 386-313-6211 |
Inspection History
| Type | Request Date | Result | Inspector |
| ELECTRIC 2ND ROUGH | 12/07/2023 | Disapproved - NO FEE | JWALKER |
| Note: 1. Spa dissconnect is to be a minimum of 5' away from the water's edge. NEC 680.13 2. The 50 amp circuit breaker at the Disconnect is to be GFI protected. NEC 680.21 3. Spa pump will need to be bonded to the screen lania. | |||
| ELECTRIC FINAL | 12/04/2023 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC FINAL | |||
| ELECTRIC 2ND ROUGH | |||
| Note: 12/7/2023 - PREVIOUS INSPECTION NOTES 1. Spa dissconnect is to be a minimum of 5' away from the water's edge. NEC 680.13 2. The 50 amp circuit breaker at the Disconnect is to be GFI protected. NEC 680.21 3. Spa pump will need to be bonded to the screen lania. |
Review History
| Department | Status | Date In | Date Out |
| ELEC | COMPLETE | 06/09/2023 | 06/09/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 05/31/2023 | 06/01/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to show wire size for all new circuits being added. 2. . Provide note on plan that any glazing 60 inches or less from water’s edge measured in a straight line and with bottom exposed edge of glazing less than 60 inches vertically above any standing or walking surface will be tempered glass before pool final inspection per R308.4.5. 3. Spa needs to be bonded to new screen enclosure. NEC 2017 680.26 |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤61.25) | 06/09/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/09/2023 |
| INSPECTION- ELECTRICAL | ¤60.00 | 06/09/2023 |
| PLAN REVIEW - MISC 32.50 | ¤32.50 | 06/09/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 06/09/2023 |
| SURCHARGE - FS 468.631 | ¤2.00 | 06/09/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤65.25 |