Permit #2023051581

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00150-0030
CONDITIONED SPACE: 1876 sqft
GARAGE: 414 sqft
OPENED PORCH (WITH ROOF) : 68 sqft
Total Square Footage: 2358 sqft
Block: 00150
Subdivision: 2155 - SECTION 32-ROYAL PALMS
Job Phone: 904-268-7730
Location Address: 151 ROLLING SANDS DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/28/2023
NOC: RECORDED
Applicant name: SCOTT CHRISTIAN HOWARD
Owner: FOCUS HOMES LLC

Address

5220 SHAD RD

JACKSONVILLE, FL 32257

Lot: 0030
Contracted Stated Job Value: ¤179,000.00
Job Description: Single Family Residence
Type: CN

Contractor

FOCUS HOMES LLC OF FLORIDA
Status Location Address Mailing Address State License Number Phone
ACTIVE

5220 SHAD RD

JACKSONVILLE, FL 32257

# 202

JACKSONVILLE, FL 32257

CRC1332443 (Exp: 08/31/2026) 904-268-7730

Sub Contractors

RONALD KEVIN HAUPT
Status Location Address State License Number Phone
ACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

CAC058534 (Exp: 08/31/2026) 407-321-0064
CLINTON J HULSLANDER SR
Status Location Address State License Number Phone Fax
ACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

CFC1430632 (Exp: 08/31/2026) 407-321-0064 407-688-8534
DANIEL GREGORY PUGLISI
Status Location Address State License Number Phone
INACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

EC13011195 (Exp: 08/31/2024) 407-302-7800
DEBORAH MAXINE JACKSON
Status Location Address State License Number Phone
ACTIVE

1165 SOUTH 5TH

MACCLENNY, FL 32063

CCC1330709 (Exp: 08/31/2026) 904-322-9409

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 12/13/2023 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ROW - STORMWATER FINAL 12/07/2023 APPROVED PFLANAGAN
Note: CORRECTIONS MADE At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved ------------------------------------------------------------------------------------ 12/6/2023 - PREVIOUS INSPECTION NOTES STILL NEED TO HAVE ALL BARE AREAS IN ADJACENT LOT SODED ------------------------------------------------------------------------------------- 12/5/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT 2) NEED TO HAVE ALL BARE AREAS ON THE RIGHT SIDE PROPERTY LINE SODED AND THE SOD NEEDS TO MATCH SOD EXISTING ON THE ADJACENT LOT
ROW - FINAL APRON (AFTER POUR) 12/06/2023 APPROVED PFLANAGAN
Note: CONTRACTOR HERE AT THE TIME OF THE INSPECTION DOING ROAD DAMAGE PATCH --------------------------------------------------------------------------------- 12/5/2023 - PREVIOUS INSPECTION NOTES NEED TO HAVE THE ROAD DAMAGE PATCHED WITH HOT PATCH BEFORE PASSING
ROW - STORMWATER FINAL 12/06/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: STILL NEED TO HAVE ALL BARE AREAS IN ADJACENT LOT SODED ------------------------------------------------------------------------------------- 12/5/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT 2) NEED TO HAVE ALL BARE AREAS ON THE RIGHT SIDE PROPERTY LINE SODED AND THE SOD NEEDS TO MATCH SOD EXISTING ON THE ADJACENT LOT
ROW - STORMWATER FINAL 12/05/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT 2) NEED TO HAVE ALL BARE AREAS ON THE RIGHT SIDE PROPERTY LINE SODED AND THE SOD NEEDS TO MATCH SOD EXISTING ON THE ADJACENT LOT
ROW - FINAL APRON (AFTER POUR) 12/05/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: NEED TO HAVE THE ROAD DAMAGE PATCHED WITH HOT PATCH BEFORE PASSING
BLD - BUILDING FINAL 12/05/2023 FINAL APPROVED JWALKER
Note: 12/4/2023 - PREVIOUS INSPECTION NOTES 1. GFI outlet under the exterior meter can is not working. 2. While testing the bedroom smoke detectors they are only setting off the hallway smoke detectore and not the other bedrooms. There is possible compatability issue due to the different types of smokes used.
BLD - BUILDING FINAL 12/04/2023 Disapproved - NO FEE JWALKER
Note: 1. GFI outlet under the exterior meter can is not working. 2. While testing the bedroom smoke detectors they are only setting off the hallway smoke detectore and not the other bedrooms. There is possible compatability issue due to the different types of smokes used.
ROW - FINAL APRON (AFTER POUR) 12/04/2023 CANCELLED BY APPLICANT WEB
ROW - STORMWATER FINAL 12/04/2023 CANCELLED BY APPLICANT WEB
U -UTILITY RESIDENTIAL FINAL 12/04/2023 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/01/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 12/01/2023 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW- PRE-APRON (PRE-POUR) 11/09/2023 CANCELLED BY APPLICANT WEB
ROW- PRE-APRON (PRE-POUR) 11/08/2023 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARTS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ELECTRIC - EARLY POWER 10/26/2023 APPROVED JWALKER
Note: Inspector Notes from Inspection 2200 9/26/2023 - PREVIOUS INSPECTION NOTES SCH 80 pedestal conduit still has not been anchored to the wall. Job box hidden by dumpster does not meet requirements of R319.1 addressing 9/25/2023 - PREVIOUS INSPECTION NOTES 9/25/23 Below listed corrections have not been made. Schedule 80 conduit will also need to be anchored to the wall now that the siding has been installed. 8/31/2023 - PREVIOUS INSPECTION NOTES 1. The metal and the Sch 80 Conduit connections are missing weather tight gaskets where they connect to the panels. 9-28-23 1. Emailed FPL at 10:53.
ELECTRIC-TUG 09/28/2023 APPROVED - AS NOTED BTAYLOR
Note: 9/26/2023 - PREVIOUS INSPECTION NOTES SCH 80 pedestal conduit still has not been anchored to the wall. Job box hidden by dumpster does not meet requirements of R319.1 addressing 9/25/2023 - PREVIOUS INSPECTION NOTES 9/25/23 Below listed corrections have not been made. Schedule 80 conduit will also need to be anchored to the wall now that the siding has been installed. 8/31/2023 - PREVIOUS INSPECTION NOTES 1. The metal and the Sch 80 Conduit connections are missing weather tight gaskets where they connect to the panels. 9-28-23 1. Emailed FPL at 10:53.
ELECTRIC-TUG 09/26/2023 Disapproved -FEE REQUIRED KSANDOE
Note: SCH 80 pedestal conduit still has not been anchored to the wall. Job box hidden by dumpster does not meet requirements of R319.1 addressing 9/25/2023 - PREVIOUS INSPECTION NOTES 9/25/23 Below listed corrections have not been made. Schedule 80 conduit will also need to be anchored to the wall now that the siding has been installed. 8/31/2023 - PREVIOUS INSPECTION NOTES 1. The metal and the Sch 80 Conduit connections are missing weather tight gaskets where they connect to the panels.
ELECTRIC-TUG 09/25/2023 Disapproved -FEE REQUIRED JWALKER
Note: 9/25/23 Below listed corrections have not been made. Schedule 80 conduit will also need to be anchored to the wall now that the siding has been installed. 8/31/2023 - PREVIOUS INSPECTION NOTES 1. The metal and the Sch 80 Conduit connections are missing weather tight gaskets where they connect to the panels.
INSULATION 09/20/2023 APPROVED JWALKER
Note: 9/19/2023 - PREVIOUS INSPECTION NOTES 9/14/23 The microwave duct has not been corrected. Check at insulation.
INSULATION 09/19/2023 CANCELLED BY APPLICANT JWALKER
Note: 9/14/23 The microwave duct has not been corrected. Check at insulation.
LATH/BRICK/ WATER BARRIER 09/15/2023 APPROVED JWALKER
Note: 9/14/2023 - PREVIOUS INSPECTION NOTES 9/14/23 1. The rear slider has not been corrected. 2. The fornt door and the corners at the front entry ceiling have not been corrected. 9/13/2023 - PREVIOUS INSPECTION NOTES 1. The rear slider and the front door have not had the self adhereing flashing installed. Details on WP of the prints. 2. Front entry ceiling, zip sheating not sealed.
ALL ROUGH 09/14/2023 APPROVED - AS NOTED JWALKER
Note: 9/14/23 The microwave duct has not been corrected. Check at insulation. 9/13/2023 - PREVIOUS INSPECTION NOTES 1. Electrical sevrice feeder wire needs to be supported minnimum 4.5' o.c. where it runs parallel with the roof trusses. NEC 334.30 2. Service feeder wires need to be connected at the subpanel, connect and tourqe. NEC 110.14 3. Fill the shower liner for water tight test. 4. The kitchen knee wall concrete cut out at the sink drain needs to be sealed. 5. Seal the microwave exhaust duct mechanical joints.
LATH/BRICK/ WATER BARRIER 09/14/2023 Disapproved -FEE REQUIRED JWALKER
Note: 9/14/23 1. The rear slider has not been corrected. 2. The fornt door and the corners at the front entry ceiling have not been corrected. 9/13/2023 - PREVIOUS INSPECTION NOTES 1. The rear slider and the front door have not had the self adhereing flashing installed. Details on WP of the prints. 2. Front entry ceiling, zip sheating not sealed.
LATH/BRICK/ WATER BARRIER 09/13/2023 Disapproved - NO FEE JWALKER
Note: 1. The rear slider and the front door have not had the self adhereing flashing installed. Details on WP of the prints. 2. Front entry ceiling, zip sheating not sealed.
ALL ROUGH 09/13/2023 Disapproved - NO FEE JWALKER
Note: 1. Electrical sevrice feeder wire needs to be supported minnimum 4.5' o.c. where it runs parallel with the roof trusses. NEC 334.30 2. Service feeder wires need to be connected at the subpanel, connect and tourqe. NEC 110.14 3. Fill the shower liner for water tight test. 4. The kitchen knee wall concrete cut out at the sink drain needs to be sealed. 5. Seal the microwave exhaust duct mechanical joints.
ROOF VALLEY & METAL 09/08/2023 APPROVED JWALKER
ROOF VALLEY & METAL 09/07/2023 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 09/07/2023 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 09/05/2023 CANCELLED BY APPLICANT WEB
ROOF VALLEY & METAL 09/05/2023 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/01/2023 APPROVED JWALKER
Note: 8/29/2023 - PREVIOUS INSPECTION NOTES
ELECTRIC-TUG 08/31/2023 Disapproved - NO FEE JWALKER
Note: 1. The metal and the Sch 80 Conduit connections are missing weather tight gaskets where they connect to the panels.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/29/2023 CANCELLED BY APPLICANT JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/25/2023 CANCELLED BY APPLICANT WEB
ROOF SHEATHING 08/24/2023 APPROVED JWALKER
WALL SHEATHING 08/24/2023 APPROVED JWALKER
MONOLITHIC SLAB 08/10/2023 CANCELLED BY APPLICANT WEB
FOUND SURVEY APPROVED (OFFICE) 08/09/2023 APPROVED TBAKER
MONOLITHIC SLAB 08/08/2023 APPROVED JWALKER
Note: 1 stop 9:21 am workers still preparing site.
U - SEWER TIE IN 08/07/2023 APPROVED MGIBSON
U - SEWER TIE IN 08/04/2023 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 08/04/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 08/04/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 07/17/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 08/08/2023 08/09/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 08/08/2023 08/08/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ELEC COMPLETE 06/23/2023 06/26/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 06/23/2023 06/23/2023
Note: Released By: JPI
SW1 COMPLETE 06/12/2023 06/12/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
SWALE COMPLETE 06/01/2023 07/17/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 05/31/2023 06/01/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD HOLD 05/31/2023 06/02/2023
Note: Held By: JPI 2023051575 1 hour not approved 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the Truss Reactions Summary Sheet for each profile type. For ease of review, please label this file Truss Summary- Profiles or of a similar nomenclature. 107.3.5
CUSVC COMPLETE 05/31/2023 06/02/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 05/31/2023 06/01/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need correct outlet spacing NEC 2017 210.52 M.Bed behind door
ENGIN1 COMPLETE 05/31/2023 06/01/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 05/31/2023 06/01/2023
LOCATE COMPLETE 05/31/2023 06/02/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 05/31/2023 06/02/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN COMPLETE 05/31/2023 06/05/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 12/12/2023
REINSPECTION RESIDENTIAL ¤40.00 12/12/2023
REINSPECTION RESIDENTIAL ¤40.00 12/12/2023
REINSPECTION RESIDENTIAL ¤40.00 12/12/2023
SW ENG REINSPECTION 20 ¤20.00 12/12/2023
SW ENG REINSPECTION 20 ¤20.00 12/12/2023
SW ENG REINSPECTION 20 ¤20.00 12/12/2023
SW ENG - REVIEW 20 ¤20.00 06/28/2023
SW ENG RES REVIEW 200 ¤200.00 06/28/2023
TRANS IMPACT FEE ADMIN ¤54.36 06/28/2023
TRANS IMPACT FEE ADMIN (¤54.36) 06/28/2023
SEWER CREDIT (¤1,466.00) 06/28/2023
SEWER INSPECTION ¤25.00 06/28/2023
SEWER CAPITAL FACILITY ¤5,344.82 06/28/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 06/28/2023
SITE PLAN 30 ¤30.00 06/28/2023
CONNECTION FEES ¤1,166.26 06/28/2023
WATER- TURN ON ¤25.00 06/28/2023
ADJUSTMENT 50% (¤417.42) 06/28/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/28/2023
INSPECTION - RESIDENTIAL ¤627.00 06/28/2023
PLAN REVIEW - RESIDENTIAL ¤177.84 06/28/2023
FIRE IMPACT FEE ADMIN ¤12.62 06/28/2023
FIRE IMPACT FEE ADMIN (¤12.62) 06/28/2023
FC IMPACT FEE EMS ¤62.00 06/28/2023
IMPACT FEE FIRE ¤420.52 06/28/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/28/2023
FC IMPACT FEE LIBRARY ¤268.00 06/28/2023
IMPACT FEE PARKS ¤1,769.15 06/28/2023
IMPACT FEE SCHOOL ¤5,450.00 06/28/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 06/28/2023
WATER -IRRIGATION INSPECTION ¤25.00 06/28/2023
PARKS IMPACT FEE ADMIN ¤53.07 06/28/2023
PARKS IMPACT FEE ADMIN (¤53.07) 06/28/2023
SURCHARGE FS 533.721 ¤4.17 06/28/2023
SURCHARGE - FS 468.631 ¤6.26 06/28/2023
SW ENG - FOUNDATION SURVEY ¤20.00 06/28/2023
SW ENG INSPECTION 80 ¤80.00 06/28/2023
SW ENG PRE APRON ¤30.00 06/28/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,051.48