Permit #2023060001

Permit Details

Status: COED

Parcel Id: 07-11-31-7022-00080-0120
CONDITIONED SPACE: 2295 sqft
GARAGE: 538 sqft
OPENED PORCH (WITH ROOF) : 201 sqft
OPENED PORCH (WITH ROOF) : 229 sqft
Total Square Footage: 3263 sqft
Block: 00080
Subdivision: 2217 - SECTION 22-WYNNFIELD
Job Phone: 912-258-2201
Location Address: 273 WESTHAMPTON DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/04/2023
NOC: RECORDED
Applicant name: JAMES FUCETOLA III
Owner: PALM COAST COMMUNITIES LLC

Address

PO BOX 22547

ST SIMONS ISLAND, GA 31522

Lot: 0120
Contracted Stated Job Value: ¤175,000.00
Job Description: Single Family Residence
Type: CN

Contractor

PALM COAST COMMUNITIES LLC
Status Location Address State License Number Phone
INACTIVE

PO BOX 22547

PALM COAST, FL 32164

CBC1262878 (Exp: 08/31/2026) 321-501-4617

Sub Contractors

GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
JEFFREY TROY SABAKA
Status Location Address State License Number Phone Fax
ACTIVE

2191 DEERWOOD ACRES DR

ST AUGUSTINE, FL 32084

CFC1427439 (Exp: 08/31/2026) 904-838-2218 904-819-0965

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/23/2024 FINAL APPROVED MKRASKI
U-CROSS CONNECTION 02/22/2024 APPROVED - AS NOTED LFITZGERALD
Note: has potable irr with DBL CHECK-no crossconnectin
ROW - STORMWATER FINAL 02/22/2024 APPROVED - AS NOTED PFLANAGAN
Note: PLEASE CLEAN ALL DIRT OUT OF CULVERT PASSING AS NOTED
U -UTILITY RESIDENTIAL FINAL 02/22/2024 FINAL APPROVED LFITZGERALD
BLD - BUILDING FINAL 02/22/2024 Disapproved - NO FEE MKRASKI
Note: 1. Extra door must be removed before final in garage 2. Exterior penitraions need to be sealed (pipe for irragation zone wires) 3. AHU closest holes in wall need to be sealed 4. Liquid line going into AHU needs to be sealed
ROW - FINAL APRON (AFTER POUR) 02/21/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/21/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 02/21/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW- PRE-APRON (PRE-POUR) 01/30/2024 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
U - SEWER TIE IN 01/25/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ELECTRIC - EARLY POWER 01/16/2024 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 12pm
INSULATION 12/11/2023 APPROVED MKRASKI
ALL ROUGH 11/29/2023 APPROVED - AS NOTED MKRASKI
Note: Slab needs to be repaired in garage wall where it exposes drain pipe
ALL ROUGH 11/21/2023 Disapproved - NO FEE MKRASKI
Note: 1. Kitchen wall needs to be sealed where power and plumbing comes up 2. Plubing in spare bathroom needs to be moved inside wall 3. Dryer duct nail plate needs to extend 2'' below top plate 4. Master bedroom window missing anchors
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/20/2023 APPROVED FWILLIS
Note: 11/20/23 - ITEMS CORRECTED 11/17/2023 - PREVIOUS INSPECTION NOTES Truss bracing passed Bearing wall has not been addressed Could not locate truss T07 Truss T15 over entry is out of plumb. 11/16/2023 - PREVIOUS INSPECTION NOTES 11/16/23 1. Load bearing detail does not match what is installed, plans call for SP2s or SP4s on studs, marked on print 2. Load bearing opening not per deatil missing SP2s or SP4s, marked on print 3. Truss layout in engineering pack is wrong, (home is reveresed on plans) 4. No trade work shall start untill after this inspection has been passed Stopped inspection did not check truss engineering 11/13/2023 - PREVIOUS INSPECTION NOTES 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23 - THERE ARE NO FLOOR PLANS IN THE SET OF PLANS ON SITE. NO DETAILS FOR THE BEARING WALL IN GARAGE. PLEASE PROVIDE DETAIL FOR ANCHOR BOLTS STRAPPING ETC... 10/20/2023 - PREVIOUS INSPECTION NOTES 1. Not ready 2. New set of plans need to be onsite for inspector
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/17/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Truss bracing passed Bearing wall has not been addressed Could not locate truss T07 Truss T15 over entry is out of plumb. 11/16/2023 - PREVIOUS INSPECTION NOTES 11/16/23 1. Load bearing detail does not match what is installed, plans call for SP2s or SP4s on studs, marked on print 2. Load bearing opening not per deatil missing SP2s or SP4s, marked on print 3. Truss layout in engineering pack is wrong, (home is reveresed on plans) 4. No trade work shall start untill after this inspection has been passed Stopped inspection did not check truss engineering 11/13/2023 - PREVIOUS INSPECTION NOTES 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23 - THERE ARE NO FLOOR PLANS IN THE SET OF PLANS ON SITE. NO DETAILS FOR THE BEARING WALL IN GARAGE. PLEASE PROVIDE DETAIL FOR ANCHOR BOLTS STRAPPING ETC... 10/20/2023 - PREVIOUS INSPECTION NOTES 1. Not ready 2. New set of plans need to be onsite for inspector
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/16/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 11/16/23 1. Load bearing detail does not match what is installed, plans call for SP2s or SP4s on studs, marked on print 2. Load bearing opening not per deatil missing SP2s or SP4s, marked on print 3. Truss layout in engineering pack is wrong, (home is reveresed on plans) 4. No trade work shall start untill after this inspection has been passed Stopped inspection did not check truss engineering 11/13/2023 - PREVIOUS INSPECTION NOTES 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23 - THERE ARE NO FLOOR PLANS IN THE SET OF PLANS ON SITE. NO DETAILS FOR THE BEARING WALL IN GARAGE. PLEASE PROVIDE DETAIL FOR ANCHOR BOLTS STRAPPING ETC... 10/20/2023 - PREVIOUS INSPECTION NOTES 1. Not ready 2. New set of plans need to be onsite for inspector
LATH/BRICK/ WATER BARRIER 11/16/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/13/2023 CANCELLED BY APPLICANT MKRASKI
Note: 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23 - THERE ARE NO FLOOR PLANS IN THE SET OF PLANS ON SITE. NO DETAILS FOR THE BEARING WALL IN GARAGE. PLEASE PROVIDE DETAIL FOR ANCHOR BOLTS STRAPPING ETC... 10/20/2023 - PREVIOUS INSPECTION NOTES 1. Not ready 2. New set of plans need to be onsite for inspector
ROOF VALLEY & METAL 10/31/2023 FINAL APPROVED FWILLIS
ROOF SHEATHING 10/23/2023 APPROVED FWILLIS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/23/2023 Disapproved - NO FEE FWILLIS
Note: 10/23/23 - THERE ARE NO FLOOR PLANS IN THE SET OF PLANS ON SITE. NO DETAILS FOR THE BEARING WALL IN GARAGE. PLEASE PROVIDE DETAIL FOR ANCHOR BOLTS STRAPPING ETC... 10/20/2023 - PREVIOUS INSPECTION NOTES 1. Not ready 2. New set of plans need to be onsite for inspector
WALL SHEATHING 10/20/2023 APPROVED MKRASKI
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/20/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 1. Not ready 2. New set of plans need to be onsite for inspector
FOUND SURVEY APPROVED (OFFICE) 10/19/2023 APPROVED TBAKER
TIE BEAM / LINTEL 10/05/2023 APPROVED BTAYLOR
Note: 10/4/2023 - PREVIOUS INSPECTION NOTES Dowel not drilled and epoxied deep enough STOPPED inspection, Check all missed dowels to ensure they are per repair detail
TIE BEAM / LINTEL 10/04/2023 Disapproved -FEE REQUIRED MKRASKI
Note: Dowel not drilled and epoxied deep enough STOPPED inspection, Check all missed dowels to ensure they are per repair detail
MONOLITHIC SLAB 09/26/2023 APPROVED JWALKER
Note: 9/25/2023 - PREVIOUS INSPECTION NOTES 1. Missing multiple downs marked on plans 2. Footings need to be back filled to form boards or additional form boards added marked on primt 3. Roots need to be removed from footing marked on print 4. Dowels in wrong cells per plans marked on print
MONOLITHIC SLAB 09/25/2023 Disapproved - NO FEE MKRASKI
Note: 1. Missing multiple downs marked on plans 2. Footings need to be back filled to form boards or additional form boards added marked on primt 3. Roots need to be removed from footing marked on print 4. Dowels in wrong cells per plans marked on print
MONOLITHIC SLAB 09/22/2023 CANCELLED BY APPLICANT WEB
PLUMBING 1ST ROUGH UNDERGROUND 09/18/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 09/18/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 08/24/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 11/08/2023 11/13/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/19/2023 10/19/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 10/19/2023 10/19/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/21/2023 07/24/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 07/21/2023 07/21/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 07/21/2023 07/24/2023
Note: Released By: JPI
MECH COMPLETE 07/21/2023 07/24/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/21/2023 07/24/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 07/21/2023 07/28/2023
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
BLD HOLD 06/01/2023 06/02/2023
Note: 1. The SF on the energy calcs varies from the floor plan SF. Please cure. 107.2.6 2. Per City Truss Submittal Requirements dated April 15, 2023, provide the Truss Reactions Summary Sheet for each profile type. For ease of review, please label this file Truss Summary- Profiles or of a similar nomenclature. 107.3.5
CUSVC COMPLETE 06/01/2023 06/05/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 06/01/2023 06/01/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/01/2023 06/01/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 06/01/2023 06/01/2023
LOCATE COMPLETE 06/01/2023 06/02/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
MECH HOLD 06/01/2023 06/05/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show R5 insulation in walls and R30 in vented attic. Energy Calcs say R8 insulation in walls and R19 in unvented attic. Revised to match. 2. Energy calcs do not match the house plans.
SW1 COMPLETE 06/01/2023 06/12/2023
Note: Released By: FRANK SLADISH - - FSLADISH@PALMCOASTGOV.COM
ZON HOLD 06/01/2023 06/02/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Need one additional tree for this lot size.
BADMIN COMPLETE 06/01/2023 06/05/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 06/01/2023 08/15/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 HOLD 06/01/2023 06/01/2023
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Benchmark elevation on site plan is 8' +/- below center of road elevation

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/23/2024
REINSPECTION RESIDENTIAL ¤40.00 02/23/2024
REINSPECTION RESIDENTIAL ¤40.00 02/23/2024
REINSPECTION RESIDENTIAL ¤40.00 02/23/2024
CONNECTION FEES ¤1,166.26 08/04/2023
FIRE IMPACT FEE ADMIN ¤12.62 08/04/2023
FIRE IMPACT FEE ADMIN (¤12.62) 08/04/2023
FC IMPACT FEE EMS ¤62.00 08/04/2023
IMPACT FEE FIRE ¤420.52 08/04/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 08/04/2023
FC IMPACT FEE LIBRARY ¤268.00 08/04/2023
IMPACT FEE PARKS ¤1,769.15 08/04/2023
IMPACT FEE SCHOOL ¤5,450.00 08/04/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 08/04/2023
WATER -IRRIGATION INSPECTION ¤25.00 08/04/2023
PARKS IMPACT FEE ADMIN ¤53.07 08/04/2023
PARKS IMPACT FEE ADMIN (¤53.07) 08/04/2023
SURCHARGE FS 533.721 ¤5.34 08/04/2023
SURCHARGE - FS 468.631 ¤8.01 08/04/2023
SW ENG - FOUNDATION SURVEY ¤20.00 08/04/2023
SW ENG INSPECTION 80 ¤80.00 08/04/2023
SW ENG PRE APRON ¤30.00 08/04/2023
SW ENG - REVIEW 20 ¤20.00 08/04/2023
SW ENG RES REVIEW 200 ¤200.00 08/04/2023
TRANS IMPACT FEE ADMIN ¤54.36 08/04/2023
TRANS IMPACT FEE ADMIN (¤54.36) 08/04/2023
SEWER CREDIT (¤1,147.00) 08/04/2023
SEWER INSPECTION ¤25.00 08/04/2023
SEWER CAPITAL FACILITY ¤5,344.82 08/04/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 08/04/2023
SITE PLAN 30 ¤30.00 08/04/2023
WATER- TURN ON ¤25.00 08/04/2023
ADJUSTMENT 50% (¤533.91) 08/04/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/04/2023
INSPECTION - RESIDENTIAL ¤808.50 08/04/2023
PLAN REVIEW - RESIDENTIAL ¤229.32 08/04/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,449.89