I want to search for...

Permit #2023060441

Permit Details

Status: COED

Parcel Id: 07-11-31-7010-00180-0140
CONDITIONED SPACE: 2208 sqft
GARAGE: 438 sqft
OPENED PORCH (WITH ROOF) : 197 sqft
Total Square Footage: 2843 sqft
Block: 00180
Subdivision: 2137 - SECTION 10-FLORIDA PARK
Job Phone: 386-445-9009
Location Address: 22 FLEMINGWOOD LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/20/2023
NOC: RECORDED
Applicant name: BRIAN ANDREW GAZZOLI
Owner: BRANDON TYLER EDWARD

Address

2 FLAXTON LANE

PALM COAST, FL 32137

Lot: 0140
Contracted Stated Job Value: ¤309,000.00
Job Description: Single Family Residence
Type: CN

Contractor

SEAGATE HOMES, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

185 CYPRESS POINT PARKWAY

Palm Coast, FL 32137

SUITE 7

Palm Coast, FL 32137

CGC1518372 (Exp: 08/31/2026) 386-246-6132

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847
DENNIS GENE GAINEY
Status Location Address State License Number Phone Fax
INACTIVE

P.O. BOX 1203

Bunnell, FL 32110

CFC046004 (Exp: 08/31/2026) (386) 437-5637 386-437-3012
ANDREW SCOTT DIGAETANO JR
Status Location Address State License Number Phone
ACTIVE

44 FORT CAROLINE

PALM COAST, FL 32137

CCC1331606 (Exp: 08/31/2026) 386-302-9063
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 04/09/2024 FINAL APPROVED JSTEWART
U-CROSS CONNECTION 04/09/2024 APPROVED DHANEY
U -UTILITY RESIDENTIAL FINAL 04/09/2024 FINAL APPROVED DHANEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/05/2024 APPROVED PFLANAGAN
Note: CORRECTIONS MADE --------------------------------------------------------------------- 3/27/2024 - PREVIOUS INSPECTION NOTES 3/27/24 SURVEY SHOWS ONLY 5 HUNDRETHS FALL OFF THE REAR OF THE STRUCTURE. COPC REQUIRES 6 TENTHS WITHIN 10FT UNLESS OTERWISE PRE APPROVED. FROM THERE IT CONTINUES TO THE REAR OF PROPERTY SHOWING IT FLOWING ONTO NEIGHBORING PROPERTY. IN THE SITE PLAN IT SHOWS THERE IS TO BE A SWALE/BERM TO DIRECT THIS DRAINAGE TO THE RIGHT DOWN TOWARDS THE ROADSIDE SWALE. I DO NOT SEE ANY ELEVATION NUMBERS INDICATING THIS ON THE FINAL SURVEY. Drainage from the structure Section 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’ Negatively impact Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 ** 02/27/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ROW FIELD SURVEY /GRADING CERTIFICATION 04/05/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW - STORMWATER FINAL 04/05/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW - FINAL APRON (AFTER POUR) 04/05/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/27/2024 Disapproved - NO FEE FSLADISH
Note: 3/27/24 SURVEY SHOWS ONLY 5 HUNDRETHS FALL OFF THE REAR OF THE STRUCTURE. COPC REQUIRES 6 TENTHS WITHIN 10FT UNLESS OTERWISE PRE APPROVED. FROM THERE IT CONTINUES TO THE REAR OF PROPERTY SHOWING IT FLOWING ONTO NEIGHBORING PROPERTY. IN THE SITE PLAN IT SHOWS THERE IS TO BE A SWALE/BERM TO DIRECT THIS DRAINAGE TO THE RIGHT DOWN TOWARDS THE ROADSIDE SWALE. I DO NOT SEE ANY ELEVATION NUMBERS INDICATING THIS ON THE FINAL SURVEY. Drainage from the structure Section 300, Drawing 300.D, Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’ Negatively impact Section 300.01 (A)(1)(C)(6) Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property. (B) __________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9270 ** 02/27/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ROW- PRE-APRON (PRE-POUR) 02/27/2024 APPROVED - AS NOTED EMADISON
Note: ** 02/27/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL
ELECTRIC - EARLY POWER 02/23/2024 APPROVED AGAETANO
INSULATION 12/04/2023 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 11-29-2023 1. Head test failed. 2. Electric line underground not installed at kitchen island. Check both at insulation.
ALL ROUGH 11/29/2023 APPROVED - AS NOTED AGAETANO
Note: 11-29-2023 1. Head test failed. 2. Electric line underground not installed at kitchen island. Check both at insulation.
LATH/BRICK/ WATER BARRIER 11/21/2023 APPROVED AGAETANO
Note: 11/16/2023 - PREVIOUS INSPECTION NOTES 11/16/23: 1). No address as required by FBC 319.1 / 501.2 2). Wire lath on the right side columns & at the gable above the entry door are installed in the wrong direction. Per the manufacturer, The Stucco Institute & ASTM C1063 wire lath must be installed perpendicular to framing. 3). All 4 sides of the house have holes in the cinder block that are missing wire lath at low voltage wires, plumbing, outlet boxes, etc. as required to prevent weak spots in the stucco.
LATH/BRICK/ WATER BARRIER 11/16/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/16/23: 1). No address as required by FBC 319.1 / 501.2 2). Wire lath on the right side columns & at the gable above the entry door are installed in the wrong direction. Per the manufacturer, The Stucco Institute & ASTM C1063 wire lath must be installed perpendicular to framing. 3). All 4 sides of the house have holes in the cinder block that are missing wire lath at low voltage wires, plumbing, outlet boxes, etc. as required to prevent weak spots in the stucco.
ROOF VALLEY & METAL 11/06/2023 APPROVED AGAETANO
WALL SHEATHING 10/25/2023 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/25/2023 APPROVED JSTEWART
FOUND SURVEY APPROVED (OFFICE) 10/12/2023 APPROVED TBAKER
TIE BEAM / LINTEL 09/28/2023 APPROVED AGAETANO
MONOLITHIC SLAB 09/01/2023 Disapproved - NO FEE AGAETANO
Note: 09-01-2023 1. Organic material in garage slab area. 2. UFER ground not visible.
MONOLITHIC SLAB 09/01/2023 APPROVED AGAETANO
Note: 9/1/2023 - PREVIOUS INSPECTION NOTES 09-01-2023 1. Organic material in garage slab area. 2. UFER ground not visible. Superintendent addressed the issues.
PLUMBING 1ST ROUGH UNDERGROUND 08/16/2023 APPROVED - AS NOTED MGIBSON
Note: 8/15/2023 - PREVIOUS INSPECTION NOTES NEED TO HAVE STAMPED APPROVED PLANS ON SITE, WITH ADDRESS POSTED CLEARLY ADDRESS STILL NOT POSTED ON POST OF PERMIT BOX. NEEDS TO BE DONE BY NEXT INSPECTION
GRAVITY SEWER TEST 08/15/2023 APPROVED MGIBSON
PLUMBING 1ST ROUGH UNDERGROUND 08/15/2023 Disapproved -FEE REQUIRED MGIBSON
Note: NEED TO HAVE STAMPED APPROVED PLANS ON SITE, WITH ADDRESS POSTED CLEARLY
U - SEWER TIE IN 08/15/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
WATER METER INSTALLATION REQUEST 07/12/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 10/12/2023 10/12/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 10/12/2023 10/12/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 08/21/2023 08/22/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLENV COMPLETE 06/12/2023 06/16/2023
Note: Released By: CAROL MINI - - CJMINI@PALMCOASTGOV.COM JM 6/15/2023 No active Gopher Tortoise burrows were found. Staff recommends installing silt fence around the perimeter to keep any new GT's from entering the property.
BLD COMPLETE 06/09/2023 06/14/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 06/09/2023 06/13/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 06/09/2023 06/12/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/09/2023 06/09/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 06/09/2023 06/09/2023
LOCATE COMPLETE 06/09/2023 06/13/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 06/09/2023 06/13/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/09/2023 06/14/2023
Note: Released By: FRANK SLADISH - - FSLADISH@PALMCOASTGOV.COM
ZON COMPLETE 06/09/2023 06/12/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 06/09/2023 07/24/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 04/03/2024
REINSPECTION RESIDENTIAL ¤40.00 04/03/2024
REINSPECTION RESIDENTIAL ¤40.00 04/03/2024
CONNECTION FEES ¤1,166.26 06/20/2023
WATER- TURN ON ¤25.00 06/20/2023
ADJUSTMENT 50% (¤560.39) 06/20/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/20/2023
INSPECTION - RESIDENTIAL ¤849.75 06/20/2023
PLAN REVIEW - RESIDENTIAL ¤241.02 06/20/2023
FIRE IMPACT FEE ADMIN ¤12.62 06/20/2023
FIRE IMPACT FEE ADMIN (¤12.62) 06/20/2023
FC IMPACT FEE EMS ¤62.00 06/20/2023
IMPACT FEE FIRE ¤420.52 06/20/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/20/2023
FC IMPACT FEE LIBRARY ¤268.00 06/20/2023
IMPACT FEE PARKS ¤1,769.15 06/20/2023
IMPACT FEE SCHOOL ¤5,450.00 06/20/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 06/20/2023
WATER -IRRIGATION INSPECTION ¤25.00 06/20/2023
PARKS IMPACT FEE ADMIN ¤53.07 06/20/2023
PARKS IMPACT FEE ADMIN (¤53.07) 06/20/2023
SURCHARGE FS 533.721 ¤5.60 06/20/2023
SURCHARGE - FS 468.631 ¤8.41 06/20/2023
SW ENG - FOUNDATION SURVEY ¤20.00 06/20/2023
SW ENG INSPECTION 80 ¤80.00 06/20/2023
SW ENG PRE APRON ¤30.00 06/20/2023
SW ENG - REVIEW 20 ¤20.00 06/20/2023
SW ENG RES REVIEW 200 ¤200.00 06/20/2023
TRANS IMPACT FEE ADMIN ¤54.36 06/20/2023
TRANS IMPACT FEE ADMIN (¤54.36) 06/20/2023
SEWER CREDIT (¤1,147.00) 06/20/2023
SEWER INSPECTION ¤25.00 06/20/2023
SEWER CAPITAL FACILITY ¤5,344.82 06/20/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 06/20/2023
SITE PLAN 30 ¤30.00 06/20/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,417.02