Permit #2023060532

Permit Details

Status: COED

Parcel Id: 07-11-31-7037-01470-0030
CONDITIONED SPACE: 2052 sqft
GARAGE: 407 sqft
OPENED PORCH (WITH ROOF) : 16 sqft
Total Square Footage: 2475 sqft
Block: 01470
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: 904-305-8901
Location Address: 104 LEE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/28/2023
NOC: RECORDED
Applicant name: ROBERT GEORGE INTILLE
Owner: MARONDA HOMES LLC, OF FLORIDA

Address

5220 SHAD RD

JACKSONVILLE, FL 32257

Lot: 0030
Contracted Stated Job Value: ¤195,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

MARONDA HOMES, LLC OF FLORIDA
Status Location Address State License Number Phone
ACTIVE

5220 SHAD ROAD

JACKSONVILLE, FL 32257

CBC1253155 (Exp: 08/31/2026) 904-268-7730

Sub Contractors

CLINTON J HULSLANDER SR
Status Location Address State License Number Phone Fax
ACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

CFC1430632 (Exp: 08/31/2026) 407-321-0064 407-688-8534
RONALD KEVIN HAUPT
Status Location Address State License Number Phone
ACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

CAC058534 (Exp: 08/31/2026) 407-321-0064
DANIEL GREGORY PUGLISI
Status Location Address State License Number Phone
INACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

EC13011195 (Exp: 08/31/2024) 407-302-7800
DEBORAH MAXINE JACKSON
Status Location Address State License Number Phone
ACTIVE

1165 SOUTH 5TH

MACCLENNY, FL 32063

CCC1330709 (Exp: 08/31/2026) 904-322-9409

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/13/2023 CANCELLED BY APPLICANT WEB
Note: 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23- Previous Note not rectified....Please seal wall in garage at ufer and install visual box. Also Ufer ground is not Utilized, Improper grounding. NEC 250.68(A). MISSING UFER GROUND .NEC..250.52(3). could not locate 2nd ground rod 6' away... NEC.250.56 12/8/2023 - PREVIOUS INSPECTION NOTES 12/8/23- Please seal wall in garage at ufer and install visual box. Seal ceiling at exhaust duct, please sela hole in wall at microwave cabinet. Please seal around the dryer vent box.
BLD - BUILDING FINAL 12/13/2023 FINAL APPROVED JSTEWART
Note: New inspection due to canceled inspection 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23- Previous Note not rectified....Please seal wall in garage at ufer and install visual box. Also Ufer ground is not Utilized, Improper grounding. NEC 250.68(A). MISSING UFER GROUND .NEC..250.52(3). could not locate 2nd ground rod 6' away... NEC.250.56 12/8/2023 - PREVIOUS INSPECTION NOTES 12/8/23- Please seal wall in garage at ufer and install visual box. Seal ceiling at exhaust duct, please sela hole in wall at microwave cabinet. Please seal around the dryer vent box.
ROW - FINAL APRON (AFTER POUR) 12/13/2023 APPROVED EMADISON
ROW - FINAL APRON (AFTER POUR) 12/11/2023 CANCELLED BY APPLICANT WEB
Note: 12/8/2023 - PREVIOUS INSPECTION NOTES HOT PATCH NEED IT
U -UTILITY RESIDENTIAL FINAL 12/11/2023 FINAL APPROVED DHANEY
Note: 12/8/2023 - PREVIOUS INSPECTION NOTES 12/4/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 No irrigation, no cross connections. Sewer clean out needs trimmed to ground level . Sewer clean out still needs trimmed down . 12/8 .
BLD - BUILDING FINAL 12/11/2023 Disapproved -FEE REQUIRED JSTEWART
Note: 12/11/23- Previous Note not rectified....Please seal wall in garage at ufer and install visual box. Also Ufer ground is not Utilized, Improper grounding. NEC 250.68(A). MISSING UFER GROUND .NEC..250.52(3). could not locate 2nd ground rod 6' away... NEC.250.56 12/8/2023 - PREVIOUS INSPECTION NOTES 12/8/23- Please seal wall in garage at ufer and install visual box. Seal ceiling at exhaust duct, please sela hole in wall at microwave cabinet. Please seal around the dryer vent box.
BLD - BUILDING FINAL 12/08/2023 Disapproved - NO FEE JSTEWART
Note: 12/8/23- Please seal wall in garage at ufer and install visual box. Seal ceiling at exhaust duct, please sela hole in wall at microwave cabinet. Please seal around the dryer vent box.
U -UTILITY RESIDENTIAL FINAL 12/08/2023 Disapproved -FEE REQUIRED DHANEY
Note: 12/4/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 No irrigation, no cross connections. Sewer clean out needs trimmed to ground level . Sewer clean out still needs trimmed down . 12/8 .
ROW - STORMWATER FINAL 12/08/2023 APPROVED GBERTOLA
Note: AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW - FINAL APRON (AFTER POUR) 12/08/2023 Disapproved -FEE REQUIRED GBERTOLA
Note: HOT PATCH NEED IT
U -UTILITY RESIDENTIAL FINAL 12/04/2023 Disapproved - NO FEE DHANEY
Note: Inspector Notes from Inspection 9035 No irrigation, no cross connections. Sewer clean out needs trimmed to ground level .
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/01/2023 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 12/01/2023 APPROVED EMADISON
U-CROSS CONNECTION 11/27/2023 APPROVED - AS NOTED JHARDING
Note: No irrigation, no cross connections.
ROW- PRE-APRON (PRE-POUR) 11/21/2023 APPROVED - AS NOTED EMADISON
Note: ** 11/21/23 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. _____________________________________________________________________________________________________________________ 11/20/2023 - PREVIOUS INSPECTION NOTES 1) THE RIGHT MITER END FOOTER NEEDS TO BE A MINIMUM OF 6"X6" 2) THE FORM BOARD ALONG EDGE OF ROAD IS IN THE ROAD NEED TO MOVE TO EDGE OF PAVEMENT 3) CULVERT PIPE NEEDS TO BE DUG OUT TO HALF WAY UP CULVERT
ROW- PRE-APRON (PRE-POUR) 11/20/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) THE RIGHT MITER END FOOTER NEEDS TO BE A MINIMUM OF 6"X6" 2) THE FORM BOARD ALONG EDGE OF ROAD IS IN THE ROAD NEED TO MOVE TO EDGE OF PAVEMENT 3) CULVERT PIPE NEEDS TO BE DUG OUT TO HALF WAY UP CULVERT
ELECTRIC - EARLY POWER 11/09/2023 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2200 Emailed FPL @ 1303. Release Power 9/22/2023 - PREVIOUS INSPECTION NOTES 9/18/2023 - PREVIOUS INSPECTION NOTES 9/18/23 No repairs made 9/14/2023 - PREVIOUS INSPECTION NOTES 9/14/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56 9/21/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56
U - SEWER TIE IN 11/03/2023 CANCELLED BY APPLICANT WEB
U - SEWER TIE IN 11/02/2023 APPROVED MKRASKI
PEP TANK INSTALLATION REQUEST 10/12/2023 APPROVED CBOWERMASTER
LATH/BRICK/ WATER BARRIER 10/09/2023 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2420 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation.
LATH/BRICK/ WATER BARRIER 10/06/2023 APPROVED FWILLIS
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2420 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation.
INSULATION 10/05/2023 APPROVED FWILLIS
Note: 10/4/2023 - PREVIOUS INSPECTION NOTES 10/4/23: 1). Left bathroom above tub, right bedroom above window, back wall above SGD & above window the stuffed in insulation is not providing the 1" minimum space as required by FBC R806.3. 2). Garage right side-Firestop is not complete. Marked with FS below. 3). Kitchen island sleeve pipe needs to be firestopped at both ends where wire enters pipe. 10/4/2023 - PREVIOUS INSPECTION NOTES 10/4/23 - ON SITE 12P INSULATION NOT COMPLETE. JUST STARTING TO INSTALL. Inspector Notes from Inspection 2420 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation.
INSULATION 10/04/2023 Disapproved -FEE REQUIRED FWILLIS
Note: 10/4/23 - ON SITE 12P INSULATION NOT COMPLETE. JUST STARTING TO INSTALL. Inspector Notes from Inspection 2420 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation.
INSULATION 10/04/2023 Disapproved - NO FEE RSIMS
Note: 10/4/23: 1). Left bathroom above tub, right bedroom above window, back wall above SGD & above window the stuffed in insulation is not providing the 1" minimum space as required by FBC R806.3. 2). Garage right side-Firestop is not complete. Marked with FS below. 3). Kitchen island sleeve pipe needs to be firestopped at both ends where wire enters pipe. 10/4/2023 - PREVIOUS INSPECTION NOTES 10/4/23 - ON SITE 12P INSULATION NOT COMPLETE. JUST STARTING TO INSTALL. Inspector Notes from Inspection 2420 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation.
WINDOW NAILING 10/02/2023 APPROVED AGAETANO
Note: Inspector Notes from Inspection 2420 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation.
ALL ROUGH 09/28/2023 APPROVED - AS NOTED JSTEWART
Note: 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation.
ELECTRIC-TUG 09/25/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 1303. Release Power 9/22/2023 - PREVIOUS INSPECTION NOTES 9/18/2023 - PREVIOUS INSPECTION NOTES 9/18/23 No repairs made 9/14/2023 - PREVIOUS INSPECTION NOTES 9/14/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56 9/21/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56
ELECTRIC-TUG 09/22/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 9/18/2023 - PREVIOUS INSPECTION NOTES 9/18/23 No repairs made 9/14/2023 - PREVIOUS INSPECTION NOTES 9/14/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56 9/21/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56
ROOF VALLEY & METAL 09/21/2023 APPROVED FWILLIS
ELECTRIC-TUG 09/18/2023 Disapproved -FEE REQUIRED MKRASKI
Note: 9/18/23 No repairs made 9/14/2023 - PREVIOUS INSPECTION NOTES 9/14/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56
ELECTRIC-TUG 09/14/2023 Disapproved -FEE REQUIRED JSTEWART
Note: 9/14/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/14/2023 APPROVED FWILLIS
WALL SHEATHING 09/13/2023 APPROVED FWILLIS
ROOF SHEATHING 09/13/2023 APPROVED FWILLIS
ELECTRIC-TUG 09/13/2023 CANCELLED BY APPLICANT WEB
ELECTRIC-TUG 09/11/2023 CANCELLED BY APPLICANT WEB
WALL SHEATHING 09/11/2023 CANCELLED BY APPLICANT WEB
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/11/2023 CANCELLED BY APPLICANT WEB
ROOF SHEATHING 09/11/2023 CANCELLED BY APPLICANT WEB
TIE BEAM / LINTEL 08/28/2023 CANCELLED BY APPLICANT WEB
TIE BEAM / LINTEL 08/24/2023 APPROVED KSANDOE
FOUND SURVEY APPROVED (OFFICE) 08/23/2023 APPROVED TBAKER
MONOLITHIC SLAB 08/11/2023 CANCELLED BY APPLICANT WEB
MONOLITHIC SLAB 08/10/2023 APPROVED MKRASKI
PLUMBING 1ST ROUGH UNDERGROUND 08/07/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 08/07/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 07/25/2023 APPROVED CBOWERMASTER
WATER METER INSTALLATION REQUEST 07/24/2023 CANCELLED BY APPLICANT WEB
WATER METER INSTALLATION REQUEST 07/18/2023 CANCELLED BY APPLICANT WEB

Review History

Department Status Date In Date Out
MECH COMPLETE 12/05/2023 12/05/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 09/28/2023 10/03/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON COMPLETE 08/24/2023 08/25/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/24/2023 08/25/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 08/24/2023 08/31/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON COMPLETE 08/23/2023 08/23/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/23/2023 08/23/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 08/23/2023 08/23/2023
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT OF 7/19 HOLD COMMENT - NOT ADDRESSED Please provide dimensions of proposed screen room and concrete pad on revised site plan to match engineered plans for screen.
BADMIN INFORMATION 07/19/2023 07/19/2023
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM for future submttals, please name your plans PLAN or the page name. (size, etc. can be included at the end of the file names)
BLD COMPLETE 07/19/2023 07/21/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 07/19/2023 07/21/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 07/19/2023 07/19/2023
Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please provide dimensions of proposed screen room and concrete pad on site plan to match engineered plans for screen.
CUSVC COMPLETE 06/26/2023 06/26/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
BLD COMPLETE 06/23/2023 06/23/2023
Note: Released By: JPI
BLD HOLD 06/12/2023 06/13/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet. 2. Product Approval number 12328.9 appears to have reached expiration per a DBPR inquiry. Please cure. 107.2.4
CUSVC HOLD 06/12/2023 06/13/2023
Note: Held By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Please correct utility application to reflect correct address & parcel number
ELEC COMPLETE 06/12/2023 06/13/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/12/2023 06/12/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 06/12/2023 06/12/2023
LOCATE COMPLETE 06/12/2023 06/14/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 06/12/2023 06/13/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/12/2023 06/20/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 06/12/2023 06/12/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 06/12/2023 07/24/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADMINISTRATIVE RESIDENTIAL ¤200.00 12/13/2023
PLAN REVIEW - REVISION ¤32.50 12/13/2023
REINSPECTION RESIDENTIAL ¤40.00 12/13/2023
REINSPECTION RESIDENTIAL ¤40.00 12/13/2023
REINSPECTION RESIDENTIAL ¤40.00 12/13/2023
REINSPECTION RESIDENTIAL ¤40.00 12/13/2023
REINSPECTION RESIDENTIAL ¤40.00 12/13/2023
CONTRACTOR CHANGE ¤20.00 12/13/2023
SW ENG REINSPECTION 20 ¤20.00 12/13/2023
SW ENG REINSPECTION 30 ¤30.00 12/13/2023
REINSPECTION FEE ¤40.00 12/13/2023
SURCHARGE FS 533.721 ¤4.47 06/28/2023
SURCHARGE - FS 468.631 ¤6.71 06/28/2023
SW ENG - FOUNDATION SURVEY ¤20.00 06/28/2023
SW ENG INSPECTION 80 ¤80.00 06/28/2023
SW ENG PRE APRON ¤30.00 06/28/2023
SW ENG - REVIEW 20 ¤20.00 06/28/2023
SW ENG RES REVIEW 200 ¤200.00 06/28/2023
TRANS IMPACT FEE ADMIN ¤54.36 06/28/2023
TRANS IMPACT FEE ADMIN (¤54.36) 06/28/2023
SEWER CREDIT (¤2,465.75) 06/28/2023
SEWER INSPECTION ¤25.00 06/28/2023
SEWER CAPITAL FACILITY ¤5,344.82 06/28/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 06/28/2023
SITE PLAN 30 ¤30.00 06/28/2023
FIRE IMPACT FEE ADMIN ¤12.62 06/28/2023
FIRE IMPACT FEE ADMIN (¤12.62) 06/28/2023
FC IMPACT FEE EMS ¤62.00 06/28/2023
IMPACT FEE FIRE ¤420.52 06/28/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/28/2023
FC IMPACT FEE LIBRARY ¤268.00 06/28/2023
IMPACT FEE PARKS ¤1,769.15 06/28/2023
IMPACT FEE SCHOOL ¤5,450.00 06/28/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 06/28/2023
WATER -IRRIGATION INSPECTION ¤25.00 06/28/2023
PARKS IMPACT FEE ADMIN ¤53.07 06/28/2023
PARKS IMPACT FEE ADMIN (¤53.07) 06/28/2023
CONNECTION FEES ¤1,166.26 06/28/2023
INSPECTION - RESIDENTIAL ¤673.75 06/28/2023
PLAN REVIEW - RESIDENTIAL ¤191.10 06/28/2023
WATER- TURN ON ¤25.00 06/28/2023
ADJUSTMENT 50% (¤447.43) 06/28/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/28/2023
Fees Total Due: ¤0.00 Total Paid: ¤19,424.98