I want to search for...
Permit #2023060532
Permit Details
Status: COED
| Parcel Id: 07-11-31-7037-01470-0030 |
| CONDITIONED SPACE: 2052 sqft |
| GARAGE: 407 sqft |
| OPENED PORCH (WITH ROOF) : 16 sqft |
| Total Square Footage: 2475 sqft |
| Block: 01470 |
| Subdivision: 2176 - SECTION 37-LAKEVIEW |
| Job Phone: 904-305-8901 |
| Location Address: 104 LEE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/28/2023 |
| NOC: RECORDED |
| Applicant name: ROBERT GEORGE INTILLE |
| Owner: MARONDA HOMES LLC, OF FLORIDA |
|
Address 5220 SHAD RD JACKSONVILLE, FL 32257 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤195,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
MARONDA HOMES, LLC OF FLORIDA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
5220 SHAD ROAD JACKSONVILLE, FL 32257 |
CBC1253155 (Exp: 08/31/2026) | 904-268-7730 |
Sub Contractors
CLINTON J HULSLANDER SR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CFC1430632 (Exp: 08/31/2026) | 407-321-0064 | 407-688-8534 |
RONALD KEVIN HAUPT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CAC058534 (Exp: 08/31/2026) | 407-321-0064 |
DANIEL GREGORY PUGLISI
| Status | Location Address | State License Number | Phone |
| INACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
EC13011195 (Exp: 08/31/2024) | 407-302-7800 |
DEBORAH MAXINE JACKSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1165 SOUTH 5TH MACCLENNY, FL 32063 |
CCC1330709 (Exp: 08/31/2026) | 904-322-9409 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/13/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23- Previous Note not rectified....Please seal wall in garage at ufer and install visual box. Also Ufer ground is not Utilized, Improper grounding. NEC 250.68(A). MISSING UFER GROUND .NEC..250.52(3). could not locate 2nd ground rod 6' away... NEC.250.56 12/8/2023 - PREVIOUS INSPECTION NOTES 12/8/23- Please seal wall in garage at ufer and install visual box. Seal ceiling at exhaust duct, please sela hole in wall at microwave cabinet. Please seal around the dryer vent box. | |||
| BLD - BUILDING FINAL | 12/13/2023 | FINAL APPROVED | JSTEWART |
| Note: New inspection due to canceled inspection 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23- Previous Note not rectified....Please seal wall in garage at ufer and install visual box. Also Ufer ground is not Utilized, Improper grounding. NEC 250.68(A). MISSING UFER GROUND .NEC..250.52(3). could not locate 2nd ground rod 6' away... NEC.250.56 12/8/2023 - PREVIOUS INSPECTION NOTES 12/8/23- Please seal wall in garage at ufer and install visual box. Seal ceiling at exhaust duct, please sela hole in wall at microwave cabinet. Please seal around the dryer vent box. | |||
| ROW - FINAL APRON (AFTER POUR) | 12/13/2023 | APPROVED | EMADISON |
| ROW - FINAL APRON (AFTER POUR) | 12/11/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 12/8/2023 - PREVIOUS INSPECTION NOTES HOT PATCH NEED IT | |||
| U -UTILITY RESIDENTIAL FINAL | 12/11/2023 | FINAL APPROVED | DHANEY |
| Note: 12/8/2023 - PREVIOUS INSPECTION NOTES 12/4/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 No irrigation, no cross connections. Sewer clean out needs trimmed to ground level . Sewer clean out still needs trimmed down . 12/8 . | |||
| BLD - BUILDING FINAL | 12/11/2023 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 12/11/23- Previous Note not rectified....Please seal wall in garage at ufer and install visual box. Also Ufer ground is not Utilized, Improper grounding. NEC 250.68(A). MISSING UFER GROUND .NEC..250.52(3). could not locate 2nd ground rod 6' away... NEC.250.56 12/8/2023 - PREVIOUS INSPECTION NOTES 12/8/23- Please seal wall in garage at ufer and install visual box. Seal ceiling at exhaust duct, please sela hole in wall at microwave cabinet. Please seal around the dryer vent box. | |||
| BLD - BUILDING FINAL | 12/08/2023 | Disapproved - NO FEE | JSTEWART |
| Note: 12/8/23- Please seal wall in garage at ufer and install visual box. Seal ceiling at exhaust duct, please sela hole in wall at microwave cabinet. Please seal around the dryer vent box. | |||
| U -UTILITY RESIDENTIAL FINAL | 12/08/2023 | Disapproved -FEE REQUIRED | DHANEY |
| Note: 12/4/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 No irrigation, no cross connections. Sewer clean out needs trimmed to ground level . Sewer clean out still needs trimmed down . 12/8 . | |||
| ROW - STORMWATER FINAL | 12/08/2023 | APPROVED | GBERTOLA |
| Note: AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. | |||
| ROW - FINAL APRON (AFTER POUR) | 12/08/2023 | Disapproved -FEE REQUIRED | GBERTOLA |
| Note: HOT PATCH NEED IT | |||
| U -UTILITY RESIDENTIAL FINAL | 12/04/2023 | Disapproved - NO FEE | DHANEY |
| Note: Inspector Notes from Inspection 9035 No irrigation, no cross connections. Sewer clean out needs trimmed to ground level . | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/01/2023 | APPROVED | EMADISON |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/01/2023 | APPROVED | EMADISON |
| U-CROSS CONNECTION | 11/27/2023 | APPROVED - AS NOTED | JHARDING |
| Note: No irrigation, no cross connections. | |||
| ROW- PRE-APRON (PRE-POUR) | 11/21/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 11/21/23 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. ** Sec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. _____________________________________________________________________________________________________________________ 11/20/2023 - PREVIOUS INSPECTION NOTES 1) THE RIGHT MITER END FOOTER NEEDS TO BE A MINIMUM OF 6"X6" 2) THE FORM BOARD ALONG EDGE OF ROAD IS IN THE ROAD NEED TO MOVE TO EDGE OF PAVEMENT 3) CULVERT PIPE NEEDS TO BE DUG OUT TO HALF WAY UP CULVERT | |||
| ROW- PRE-APRON (PRE-POUR) | 11/20/2023 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) THE RIGHT MITER END FOOTER NEEDS TO BE A MINIMUM OF 6"X6" 2) THE FORM BOARD ALONG EDGE OF ROAD IS IN THE ROAD NEED TO MOVE TO EDGE OF PAVEMENT 3) CULVERT PIPE NEEDS TO BE DUG OUT TO HALF WAY UP CULVERT | |||
| ELECTRIC - EARLY POWER | 11/09/2023 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2200 Emailed FPL @ 1303. Release Power 9/22/2023 - PREVIOUS INSPECTION NOTES 9/18/2023 - PREVIOUS INSPECTION NOTES 9/18/23 No repairs made 9/14/2023 - PREVIOUS INSPECTION NOTES 9/14/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56 9/21/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56 | |||
| U - SEWER TIE IN | 11/03/2023 | CANCELLED BY APPLICANT | WEB |
| U - SEWER TIE IN | 11/02/2023 | APPROVED | MKRASKI |
| PEP TANK INSTALLATION REQUEST | 10/12/2023 | APPROVED | CBOWERMASTER |
| LATH/BRICK/ WATER BARRIER | 10/09/2023 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2420 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation. | |||
| LATH/BRICK/ WATER BARRIER | 10/06/2023 | APPROVED | FWILLIS |
| Note: New inspection due to canceled inspection Inspector Notes from Inspection 2420 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation. | |||
| INSULATION | 10/05/2023 | APPROVED | FWILLIS |
| Note: 10/4/2023 - PREVIOUS INSPECTION NOTES 10/4/23: 1). Left bathroom above tub, right bedroom above window, back wall above SGD & above window the stuffed in insulation is not providing the 1" minimum space as required by FBC R806.3. 2). Garage right side-Firestop is not complete. Marked with FS below. 3). Kitchen island sleeve pipe needs to be firestopped at both ends where wire enters pipe. 10/4/2023 - PREVIOUS INSPECTION NOTES 10/4/23 - ON SITE 12P INSULATION NOT COMPLETE. JUST STARTING TO INSTALL. Inspector Notes from Inspection 2420 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation. | |||
| INSULATION | 10/04/2023 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: 10/4/23 - ON SITE 12P INSULATION NOT COMPLETE. JUST STARTING TO INSTALL. Inspector Notes from Inspection 2420 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation. | |||
| INSULATION | 10/04/2023 | Disapproved - NO FEE | RSIMS |
| Note: 10/4/23: 1). Left bathroom above tub, right bedroom above window, back wall above SGD & above window the stuffed in insulation is not providing the 1" minimum space as required by FBC R806.3. 2). Garage right side-Firestop is not complete. Marked with FS below. 3). Kitchen island sleeve pipe needs to be firestopped at both ends where wire enters pipe. 10/4/2023 - PREVIOUS INSPECTION NOTES 10/4/23 - ON SITE 12P INSULATION NOT COMPLETE. JUST STARTING TO INSTALL. Inspector Notes from Inspection 2420 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation. | |||
| WINDOW NAILING | 10/02/2023 | APPROVED | AGAETANO |
| Note: Inspector Notes from Inspection 2420 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation. | |||
| ALL ROUGH | 09/28/2023 | APPROVED - AS NOTED | JSTEWART |
| Note: 9/28/23- No Water pressure in Building. Please obtain revision of Product aproval for windows/doors installed. Front entry door not installed, Added a window nailing inspection for the front Entry door. (RO is blocked off with plastic). Will check at insulation. | |||
| ELECTRIC-TUG | 09/25/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Emailed FPL @ 1303. Release Power 9/22/2023 - PREVIOUS INSPECTION NOTES 9/18/2023 - PREVIOUS INSPECTION NOTES 9/18/23 No repairs made 9/14/2023 - PREVIOUS INSPECTION NOTES 9/14/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56 9/21/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56 | |||
| ELECTRIC-TUG | 09/22/2023 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 9/18/2023 - PREVIOUS INSPECTION NOTES 9/18/23 No repairs made 9/14/2023 - PREVIOUS INSPECTION NOTES 9/14/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56 9/21/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56 | |||
| ROOF VALLEY & METAL | 09/21/2023 | APPROVED | FWILLIS |
| ELECTRIC-TUG | 09/18/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 9/18/23 No repairs made 9/14/2023 - PREVIOUS INSPECTION NOTES 9/14/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56 | |||
| ELECTRIC-TUG | 09/14/2023 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 9/14/23- Improper grounding. No schedule 80 Chase pipe installed. MISSING UFER GROUND .NEC..250.52(3) could not locate 2nd ground rod 6' away, NEC.250.56 | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/14/2023 | APPROVED | FWILLIS |
| WALL SHEATHING | 09/13/2023 | APPROVED | FWILLIS |
| ROOF SHEATHING | 09/13/2023 | APPROVED | FWILLIS |
| ELECTRIC-TUG | 09/13/2023 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC-TUG | 09/11/2023 | CANCELLED BY APPLICANT | WEB |
| WALL SHEATHING | 09/11/2023 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/11/2023 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING | 09/11/2023 | CANCELLED BY APPLICANT | WEB |
| TIE BEAM / LINTEL | 08/28/2023 | CANCELLED BY APPLICANT | WEB |
| TIE BEAM / LINTEL | 08/24/2023 | APPROVED | KSANDOE |
| FOUND SURVEY APPROVED (OFFICE) | 08/23/2023 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 08/11/2023 | CANCELLED BY APPLICANT | WEB |
| MONOLITHIC SLAB | 08/10/2023 | APPROVED | MKRASKI |
| PLUMBING 1ST ROUGH UNDERGROUND | 08/07/2023 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 08/07/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 07/25/2023 | APPROVED | CBOWERMASTER |
| WATER METER INSTALLATION REQUEST | 07/24/2023 | CANCELLED BY APPLICANT | WEB |
| WATER METER INSTALLATION REQUEST | 07/18/2023 | CANCELLED BY APPLICANT | WEB |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 12/05/2023 | 12/05/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/28/2023 | 10/03/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/24/2023 | 08/25/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/24/2023 | 08/25/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/24/2023 | 08/31/2023 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/23/2023 | 08/23/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/23/2023 | 08/23/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/23/2023 | 08/23/2023 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM REPEAT OF 7/19 HOLD COMMENT - NOT ADDRESSED Please provide dimensions of proposed screen room and concrete pad on revised site plan to match engineered plans for screen. | |||
| BADMIN | INFORMATION | 07/19/2023 | 07/19/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM for future submttals, please name your plans PLAN or the page name. (size, etc. can be included at the end of the file names) | |||
| BLD | COMPLETE | 07/19/2023 | 07/21/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/19/2023 | 07/21/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 07/19/2023 | 07/19/2023 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please provide dimensions of proposed screen room and concrete pad on site plan to match engineered plans for screen. | |||
| CUSVC | COMPLETE | 06/26/2023 | 06/26/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/23/2023 | 06/23/2023 |
| Note: Released By: JPI | |||
| BLD | HOLD | 06/12/2023 | 06/13/2023 |
| Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet. 2. Product Approval number 12328.9 appears to have reached expiration per a DBPR inquiry. Please cure. 107.2.4 | |||
| CUSVC | HOLD | 06/12/2023 | 06/13/2023 |
| Note: Held By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Please correct utility application to reflect correct address & parcel number | |||
| ELEC | COMPLETE | 06/12/2023 | 06/13/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/12/2023 | 06/12/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/12/2023 | 06/12/2023 |
| LOCATE | COMPLETE | 06/12/2023 | 06/14/2023 |
| Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/12/2023 | 06/13/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/12/2023 | 06/20/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/12/2023 | 06/12/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 06/12/2023 | 07/24/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADMINISTRATIVE RESIDENTIAL | ¤200.00 | 12/13/2023 |
| PLAN REVIEW - REVISION | ¤32.50 | 12/13/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/13/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/13/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/13/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/13/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/13/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 12/13/2023 |
| SW ENG REINSPECTION 20 | ¤20.00 | 12/13/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 12/13/2023 |
| REINSPECTION FEE | ¤40.00 | 12/13/2023 |
| SURCHARGE FS 533.721 | ¤4.47 | 06/28/2023 |
| SURCHARGE - FS 468.631 | ¤6.71 | 06/28/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 06/28/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 06/28/2023 |
| SW ENG PRE APRON | ¤30.00 | 06/28/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/28/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/28/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 06/28/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 06/28/2023 |
| SEWER CREDIT | (¤2,465.75) | 06/28/2023 |
| SEWER INSPECTION | ¤25.00 | 06/28/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 06/28/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 06/28/2023 |
| SITE PLAN 30 | ¤30.00 | 06/28/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 06/28/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 06/28/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 06/28/2023 |
| IMPACT FEE FIRE | ¤420.52 | 06/28/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 06/28/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 06/28/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 06/28/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 06/28/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 06/28/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 06/28/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 06/28/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 06/28/2023 |
| CONNECTION FEES | ¤1,166.26 | 06/28/2023 |
| INSPECTION - RESIDENTIAL | ¤673.75 | 06/28/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤191.10 | 06/28/2023 |
| WATER- TURN ON | ¤25.00 | 06/28/2023 |
| ADJUSTMENT 50% | (¤447.43) | 06/28/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/28/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤19,424.98 |