I want to search for...
Permit #2023060536
Permit Details
Status: COED
| Parcel Id: 07-11-31-7027-00160-0100 |
| CONDITIONED SPACE: 2286 sqft |
| GARAGE: 588 sqft |
| OPENED PORCH (WITH ROOF) : 54 sqft |
| SCREEN PORCH (SOLID ROOF) : 307 sqft |
| Total Square Footage: 3235 sqft |
| Block: 00160 |
| Subdivision: 2128 - SECTION 27-WYNNFIELD |
| Job Phone: 904-305-8901 |
| Location Address: 14 WOODWORTH DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 06/28/2023 |
| NOC: RECORDED |
| Applicant name: ROBERT GEORGE INTILLE |
| Owner: MARONDA HOMES, LLC, OF FLORIDA |
|
Address 5220 SHAD RD JACKSONVILLE, FL 32257 |
| Lot: 0100 |
| Contracted Stated Job Value: ¤229,000.00 |
| Job Description: SINGLE FAMILY HOME |
| Type: CN |
Contractor
MARONDA HOMES, LLC OF FLORIDA
| Status | Location Address | State License Number | Phone |
| ACTIVE |
5220 SHAD ROAD JACKSONVILLE, FL 32257 |
CBC1253155 (Exp: 08/31/2026) | 904-268-7730 |
Sub Contractors
JOSEPH H STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PKWY SANFORD, FL 32771 |
CAC043953 (Exp: 08/31/2026) | 877-906-1113 |
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
DEBORAH MAXINE JACKSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1165 SOUTH 5TH MACCLENNY, FL 32063 |
CCC1330709 (Exp: 08/31/2026) | 904-322-9409 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 12/27/2023 | FINAL APPROVED | LMILLER |
| Note: 12-27-23 Notes below rwsolved 12/21/2023 - PREVIOUS INSPECTION NOTES 12/21/23 1. Shear screws for anti back flows on hose bibs are missing 2. Thermostat is not working 3. No E-cals on site 4. Front bathroom mixing valve trim needs to be sealed at tile Stopped inspection not ready 12/20/2023 - PREVIOUS INSPECTION NOTES Blower door test being conducted, inspection stopped not ready | |||
| BLD - BUILDING FINAL | 12/21/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 12/21/23 1. Shear screws for anti back flows on hose bibs are missing 2. Thermostat is not working 3. No E-cals on site 4. Front bathroom mixing valve trim needs to be sealed at tile Stopped inspection not ready 12/20/2023 - PREVIOUS INSPECTION NOTES Blower door test being conducted, inspection stopped not ready | |||
| BLD - BUILDING FINAL | 12/20/2023 | Disapproved - NO FEE | MKRASKI |
| Note: Blower door test being conducted, inspection stopped not ready | |||
| U-CROSS CONNECTION | 12/20/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irr-no cross connection | |||
| ROW - FINAL APRON (AFTER POUR) | 12/20/2023 | APPROVED | TPOLACEK |
| Note: 12/20/23 ** PIPE IS GOOD, CUTS ARE MADE, CULVERT CLEAR HOT PATCH COMPLETE. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 12/19/23 ** HOT PATCH STILL NEEDED BEFORE A AFTER POUR CAN BE SUBMITTED. FIELD SURVEY APPROVED. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 12/20/2023 | APPROVED | TPOLACEK |
| Note: 12/20/23 ** UPON WALKING SITE ALL LOOKS GOOD. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 12/19/23 ** HOT PATCH STILL NEEDED BEFORE A AFTER POUR CAN BE SUBMITTED. FIELD SURVEY APPROVED. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| U -UTILITY RESIDENTIAL FINAL | 12/20/2023 | FINAL APPROVED | LFITZGERALD |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/19/2023 | APPROVED - AS NOTED | TPOLACEK |
| Note: 12/19/23 ** HOT PATCH STILL NEEDED BEFORE A AFTER POUR CAN BE SUBMITTED. FIELD SURVEY APPROVED. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/18/2023 | APPROVED | TPOLACEK |
| Note: 12/18/23 UPON WALKING PROPERTY THE FINAL SURVEY WILL WORK AS INDICATED | |||
| ROW- PRE-APRON (PRE-POUR) | 12/06/2023 | APPROVED | PFLANAGAN |
| Note: CORRECTIONS MADE IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------------------------------- 12/5/2023 - PREVIOUS INSPECTION NOTES NO CHANGES FROM YESTERDAYS INSPECTION SOIL AND ROCK IS STILL TO SOFT NEED TO COMPACT SOIL DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) ----------------------------------------------------------------------------- 12/4/2023 - PREVIOUS INSPECTION NOTES SOIL AND ROCK IS TO SOFT NEED TO COMPACT SOIL SO IT MEETS CITY'S STANDARDS. DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) | |||
| ROW- PRE-APRON (PRE-POUR) | 12/05/2023 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: NO CHANGES FROM YESTERDAYS INSPECTION SOIL AND ROCK IS STILL TO SOFT NEED TO COMPACT SOIL DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) ----------------------------------------------------------------------------- 12/4/2023 - PREVIOUS INSPECTION NOTES SOIL AND ROCK IS TO SOFT NEED TO COMPACT SOIL SO IT MEETS CITY'S STANDARDS. DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) | |||
| ROW- PRE-APRON (PRE-POUR) | 12/04/2023 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: SOIL AND ROCK IS TO SOFT NEED TO COMPACT SOIL SO IT MEETS CITY'S STANDARDS. DRAWING #300 G (3) SOIL SUBGRADE TO BE COMPACTED TO 95% PROCTOR DENSITY (PER ASTM D 1557) | |||
| ELECTRIC - EARLY POWER | 11/20/2023 | APPROVED | JSTEWART |
| U - SEWER TIE IN | 11/14/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| LATH/BRICK/ WATER BARRIER | 10/13/2023 | APPROVED | JSTEWART |
| Note: New inspection due to canceled inspection 10/10/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 9/22/23: Still need revision as listed below before any additional inspections will be approved. Inspector Notes from Inspection 2450 9/18/23: 1). Need revision for Truss HGR26 to show correct W2 web orientation on left side as shown on truss details. Also, missing engineering on this web. 2). Front right bedroom straps need nails fully embedded. Contractor to check all before next inspection. 9/15/2023 - PREVIOUS INSPECTION NOTES Sheathing not nailed off properly | |||
| LATH/BRICK/ WATER BARRIER | 10/12/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 10/10/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2467 9/22/23: Still need revision as listed below before any additional inspections will be approved. Inspector Notes from Inspection 2450 9/18/23: 1). Need revision for Truss HGR26 to show correct W2 web orientation on left side as shown on truss details. Also, missing engineering on this web. 2). Front right bedroom straps need nails fully embedded. Contractor to check all before next inspection. 9/15/2023 - PREVIOUS INSPECTION NOTES Sheathing not nailed off properly | |||
| LATH/BRICK/ WATER BARRIER | 10/10/2023 | CANCELLED BY APPLICANT | MKRASKI |
| Note: Inspector Notes from Inspection 2467 9/22/23: Still need revision as listed below before any additional inspections will be approved. Inspector Notes from Inspection 2450 9/18/23: 1). Need revision for Truss HGR26 to show correct W2 web orientation on left side as shown on truss details. Also, missing engineering on this web. 2). Front right bedroom straps need nails fully embedded. Contractor to check all before next inspection. 9/15/2023 - PREVIOUS INSPECTION NOTES Sheathing not nailed off properly | |||
| INSULATION | 10/09/2023 | APPROVED | MKRASKI |
| ALL ROUGH | 10/03/2023 | APPROVED | MKRASKI |
| ALL ROUGH | 10/02/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Nail plate required for island power chase (at wall) 2. Disconnect for ODU is behind A/C pad will need to be moved 3. Several windows missing stickers 4. Window missing in garage 5. Product approval for MI windows does not match what is installed 6. Mullbar bracket is missing anchors in back doublt window | |||
| ROOF VALLEY & METAL | 09/22/2023 | APPROVED - AS NOTED | RSIMS |
| Note: 9/22/23: Still need revision as listed below before any additional inspections will be approved. Inspector Notes from Inspection 2450 9/18/23: 1). Need revision for Truss HGR26 to show correct W2 web orientation on left side as shown on truss details. Also, missing engineering on this web. 2). Front right bedroom straps need nails fully embedded. Contractor to check all before next inspection. 9/15/2023 - PREVIOUS INSPECTION NOTES Sheathing not nailed off properly | |||
| WALL SHEATHING | 09/18/2023 | APPROVED - AS NOTED | RSIMS |
| Note: 9/18/23: 1). Need revision for Truss HGR26 to show correct W2 web orientation on left side as shown on truss details. Also, missing engineering on this web. 2). Front right bedroom straps need nails fully embedded. Contractor to check all before next inspection. 9/15/2023 - PREVIOUS INSPECTION NOTES Sheathing not nailed off properly | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/18/2023 | APPROVED - AS NOTED | RSIMS |
| Note: 9/18/23: 1). Need revision for Truss HGR26 to show correct W2 web orientation on left side as shown on truss details. Also, missing engineering on this web. 2). Front right bedroom straps need nails fully embedded. Contractor to check all before next inspection. 9/15/2023 - PREVIOUS INSPECTION NOTES 1. Framers still working | |||
| WALL SHEATHING | 09/15/2023 | Disapproved - NO FEE | MKRASKI |
| Note: Sheathing not nailed off properly | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/15/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. Framers still working | |||
| ROOF SHEATHING | 09/15/2023 | APPROVED | MKRASKI |
| ROOF SHEATHING | 09/14/2023 | CANCELLED BY APPLICANT | WEB |
| WALL SHEATHING | 09/14/2023 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/14/2023 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC-TUG | 09/14/2023 | APPROVED | JWALKER |
| ELECTRIC-TUG | 09/13/2023 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/13/2023 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING | 09/12/2023 | CANCELLED BY APPLICANT | WEB |
| WALL SHEATHING | 09/12/2023 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC-TUG | 09/11/2023 | CANCELLED BY APPLICANT | WEB |
| WALL SHEATHING | 09/08/2023 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING | 09/08/2023 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/08/2023 | CANCELLED BY APPLICANT | WEB |
| TIE BEAM / LINTEL | 08/23/2023 | CANCELLED BY APPLICANT | WEB |
| TIE BEAM / LINTEL | 08/21/2023 | APPROVED | FWILLIS |
| FOUND SURVEY APPROVED (OFFICE) | 08/09/2023 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 08/09/2023 | APPROVED | FWILLIS |
| Note: 8/8/2023 - PREVIOUS INSPECTION NOTES 8/8/23: 1). Significant dirt cave in at ground wire on right side. 2). Footers throughout have dirt wash in reducing rebar clearance to under 3" minimum. 3). 6" sleeve for 3" PVC drain is not completely through the footer. (on right) | |||
| MONOLITHIC SLAB | 08/08/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 8/8/23: 1). Significant dirt cave in at ground wire on right side. 2). Footers throughout have dirt wash in reducing rebar clearance to under 3" minimum. 3). 6" sleeve for 3" PVC drain is not completely through the footer. (on right) | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 08/02/2023 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 08/02/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 07/18/2023 | APPROVED | CSTONE |
| Note: 7/14/2023 8:08:22 AM- PREVIOUS INSPECTION NOTES clearing still | |||
| WATER METER INSTALLATION REQUEST | 07/13/2023 | Disapproved -FEE REQUIRED | CBOWERMASTER |
| Note: clearing still |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 10/02/2023 | 10/03/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/08/2023 | 08/09/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/08/2023 | 08/08/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/23/2023 | 06/23/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/23/2023 | 06/23/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/12/2023 | 06/13/2023 |
| Note: Held By: JPI 20230600532 Maronda 1 hour not approved 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet. 2. Product Approval number 12328.9 appears to have reached expiration per a DBPR inquiry. Please cure. 107.2.4 | |||
| CUSVC | COMPLETE | 06/12/2023 | 06/14/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/12/2023 | 06/12/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/12/2023 | 06/12/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/12/2023 | 06/12/2023 |
| LOCATE | COMPLETE | 06/12/2023 | 06/14/2023 |
| Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/12/2023 | 06/13/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide return air out of Den on duct layout | |||
| SW1 | COMPLETE | 06/12/2023 | 06/20/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/12/2023 | 06/13/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 06/12/2023 | 07/25/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/27/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/21/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/21/2023 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/21/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 12/21/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 12/21/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 12/21/2023 |
| SW ENG REINSPECTION 30 | ¤30.00 | 12/21/2023 |
| REINSPECTION FEE | ¤40.00 | 12/21/2023 |
| SURCHARGE FS 533.721 | ¤5.32 | 06/28/2023 |
| SURCHARGE - FS 468.631 | ¤7.98 | 06/28/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 06/28/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 06/28/2023 |
| SW ENG PRE APRON | ¤30.00 | 06/28/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 06/28/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 06/28/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 06/28/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 06/28/2023 |
| SEWER CREDIT | (¤1,466.00) | 06/28/2023 |
| SEWER INSPECTION | ¤25.00 | 06/28/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 06/28/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 06/28/2023 |
| SITE PLAN 30 | ¤30.00 | 06/28/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 06/28/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 06/28/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 06/28/2023 |
| IMPACT FEE FIRE | ¤420.52 | 06/28/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 06/28/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 06/28/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 06/28/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 06/28/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 06/28/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 06/28/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 06/28/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 06/28/2023 |
| CONNECTION FEES | ¤1,166.26 | 06/28/2023 |
| WATER- TURN ON | ¤25.00 | 06/28/2023 |
| ADJUSTMENT 50% | (¤532.15) | 06/28/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 06/28/2023 |
| INSPECTION - RESIDENTIAL | ¤805.75 | 06/28/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤228.54 | 06/28/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,269.07 |