I want to search for...

Permit #2023060738

Permit Details

Status: COED

Parcel Id: 28-10-30-5415-00000-0340
CONDITIONED SPACE: 2147 sqft
GARAGE: 557 sqft
OPENED PORCH (WITH ROOF) : 54 sqft
PATIO/DECK (NO ROOF) : 70 sqft
Total Square Footage: 2828 sqft
Subdivision: 2310 - SAWMILL BRANCH 2A
Job Phone: 904-219-3385
Location Address: 14 HULETT WOODS RD
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/13/2023
NOC: RECORDED
Applicant name: RAYMOND CLIVE CROSBY
Owner: D R HORTON INC

Address

4220 RACE TRACK ROAD

SAINT JOHNS, FL 32259

Lot: 34
Contracted Stated Job Value: ¤214,700.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

DR HORTON, INC.
Status Location Address State License Number Phone Fax
ACTIVE

4220 RACE TRACK RD

SAINT JOHNS, FL 32259

CBC058997 (Exp: 08/31/2026) 904-268-2845 904-899-5992

Sub Contractors

EDWARD DOUGLAS TENNANT
Status Location Address State License Number Phone Fax
INACTIVE

3370 AGRICULTURAL CENTER DRIVE

ST. AUGUSTINE , FL 32092

CAC1813372 (Exp: 08/31/2026) (904)829-8898 (904)829-6587
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
JAMES M GREENSLADE
Status Location Address State License Number Phone Fax
ACTIVE

311 S BAY ST

BUNNELL, FL 32110

EC13006083 (Exp: 08/31/2026) 386-263-2960 386-263-2980

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/13/2023 APPROVED RSIMS
U-CROSS CONNECTION 12/13/2023 APPROVED DHANEY
ROW - STORMWATER FINAL 12/13/2023 APPROVED EMADISON
U -UTILITY RESIDENTIAL FINAL 12/13/2023 FINAL APPROVED DHANEY
ROW - FINAL APRON (AFTER POUR) 12/05/2023 APPROVED GBERTOLA
Note: AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- FINAL SURVEY/GRADING CERTIFICATION 12/05/2023 APPROVED GBERTOLA
Note: AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW FIELD SURVEY /GRADING CERTIFICATION 12/05/2023 APPROVED GBERTOLA
Note: AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ELECTRIC - EARLY POWER 11/14/2023 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 10am
ROW- PRE-APRON (PRE-POUR) 11/08/2023 APPROVED GBERTOLA
Note: READY TO POUR . MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVERT DETAIL
GRAVITY SEWER TEST 10/24/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 10/24/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
INSULATION 10/18/2023 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 10/11/23: Must be resolved prior to Insulation Inspection. Check at Insulation Inspection! Marked on plans. 1). Smoke detector in kitchen area is too close to supply register. NFPA72 - 29.8.3.4(6) 2). Smoke detector in Bedroom 3 is too close to supply register. NFPA72 - 29.8.3.4(6) Inspector Notes from Inspection 2467 9/20/23- Missing Metal flashing at (2) eybrow overhangs at garage, make sure installed at shingle installation/before final. Inspector Notes from Inspection 2450 9/6/23- Please moving forward, do not caulk over nails in Hardy Wall board before inspection. Need to see nail head size, and embedment.
LATH/BRICK/ WATER BARRIER 10/11/2023 APPROVED RSIMS
Note: Inspector Notes from Inspection 2467 9/20/23- Missing Metal flashing at (2) eybrow overhangs at garage, make sure installed at shingle installation/before final. Inspector Notes from Inspection 2450 9/6/23- Please moving forward, do not caulk over nails in Hardy Wall board before inspection. Need to see nail head size, and embedment.
ALL ROUGH 10/11/2023 APPROVED - AS NOTED RSIMS
Note: 10/11/23: Must be resolved prior to Insulation Inspection. Check at Insulation Inspection! Marked on plans. 1). Smoke detector in kitchen area is too close to supply register. NFPA72 - 29.8.3.4(6) 2). Smoke detector in Bedroom 3 is too close to supply register. NFPA72 - 29.8.3.4(6) Inspector Notes from Inspection 2467 9/20/23- Missing Metal flashing at (2) eybrow overhangs at garage, make sure installed at shingle installation/before final. Inspector Notes from Inspection 2450 9/6/23- Please moving forward, do not caulk over nails in Hardy Wall board before inspection. Need to see nail head size, and embedment.
ELECTRIC-TUG 09/22/2023 APPROVED - AS NOTED JSTEWART
Note: 9/22/23- Authorize release of email to FPL @ 9:37a.
ROOF VALLEY & METAL 09/20/2023 APPROVED - AS NOTED JSTEWART
Note: 9/20/23- Missing Metal flashing at (2) eybrow overhangs at garage, make sure installed at shingle installation/before final. Inspector Notes from Inspection 2450 9/6/23- Please moving forward, do not caulk over nails in Hardy Wall board before inspection. Need to see nail head size, and embedment.
WALL SHEATHING 09/06/2023 APPROVED - AS NOTED JSTEWART
Note: 9/6/23- Please moving forward, do not caulk over nails in Hardy Wall board before inspection. Need to see nail head size, and embedment.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 09/06/2023 APPROVED - AS NOTED JSTEWART
Note: 9/6/23- Please change 2x6 header to a 2x8 header per plan in Laundry rm. will check at all rough.
FOUND SURVEY APPROVED (OFFICE) 08/17/2023 APPROVED TDOAK
MONOLITHIC SLAB 08/11/2023 APPROVED FWILLIS
Note: 8/10/2023 - PREVIOUS INSPECTION NOTES 8/10/23: No Stamped Approved Plans in Permit Box laying on the ground. (FBC 107.3.1)
MONOLITHIC SLAB 08/10/2023 Disapproved -FEE REQUIRED RSIMS
Note: 8/10/23: No Stamped Approved Plans in Permit Box laying on the ground. (FBC 107.3.1)
PLUMBING 1ST ROUGH UNDERGROUND 08/08/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 08/03/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 08/17/2023 08/17/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 08/17/2023 08/17/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
MECH COMPLETE 07/10/2023 07/11/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
URB COMPLETE 06/16/2023 06/16/2023
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM
BLD COMPLETE 06/14/2023 06/14/2023
Note: Released By: JPI
CUSVC COMPLETE 06/14/2023 06/15/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 06/14/2023 06/20/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/14/2023 06/15/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 06/14/2023 06/20/2023
LOCATE COMPLETE 06/14/2023 06/20/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
MECH HOLD 06/14/2023 06/20/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Square footage on Energy Calcs does not match the house plans 2. Direction house faces on Heatload does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2020 7Th Edition
SW1 COMPLETE 06/14/2023 06/21/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 06/14/2023 06/16/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BADMIN COMPLETE 06/14/2023 06/20/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/14/2023
CONNECTION FEES ¤25.00 07/13/2023
FIRE IMPACT FEE ADMIN ¤12.62 07/13/2023
FIRE IMPACT FEE ADMIN (¤12.62) 07/13/2023
FC IMPACT FEE EMS ¤62.00 07/13/2023
IMPACT FEE FIRE ¤420.52 07/13/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/13/2023
FC IMPACT FEE LIBRARY ¤268.00 07/13/2023
IMPACT FEE PARKS ¤1,769.15 07/13/2023
IMPACT FEE SCHOOL ¤5,450.00 07/13/2023
IMPACT FEE TRANSPORTATION ¤3,311.00 07/13/2023
WATER -IRRIGATION INSPECTION ¤25.00 07/13/2023
PARKS IMPACT FEE ADMIN ¤53.07 07/13/2023
PARKS IMPACT FEE ADMIN (¤53.07) 07/13/2023
SURCHARGE FS 533.721 ¤4.84 07/13/2023
SURCHARGE - FS 468.631 ¤7.27 07/13/2023
SW ENG - FOUNDATION SURVEY ¤20.00 07/13/2023
SW ENG INSPECTION 80 ¤80.00 07/13/2023
SW ENG PRE APRON ¤30.00 07/13/2023
SW ENG - REVIEW 20 ¤20.00 07/13/2023
SW ENG RES REVIEW 200 ¤200.00 07/13/2023
TRANS IMPACT FEE ADMIN ¤99.33 07/13/2023
TRANS IMPACT FEE ADMIN (¤99.33) 07/13/2023
SEWER INSPECTION ¤25.00 07/13/2023
SEWER CAPITAL FACILITY ¤2,803.23 07/13/2023
WATER CAPITAL FACILITY FEE ¤2,605.24 07/13/2023
SITE PLAN 30 ¤30.00 07/13/2023
WATER-METER ¤505.39 07/13/2023
WATER-METER ¤419.86 07/13/2023
ADJUSTMENT 50% (¤484.49) 07/13/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/13/2023
INSPECTION - RESIDENTIAL ¤731.50 07/13/2023
PLAN REVIEW - RESIDENTIAL ¤207.48 07/13/2023
Fees Total Due: ¤0.00 Total Paid: ¤18,823.99