Permit #2023060796

Permit Details

Status: COED

Parcel Id: 07-11-31-7014-00070-0710
CONDITIONED SPACE: 1992 sqft
GARAGE: 674 sqft
OPENED PORCH (WITH ROOF) : 333 sqft
Total Square Footage: 2999 sqft
Block: 00070
Subdivision: 2202 - SECTION 14-COUNTRY CLUB COVE
Job Phone: 386-445-9009
Location Address: 12 CROSSGATE CT E
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 06/27/2023
NOC: RECORDED
Applicant name: BRIAN ANDREW GAZZOLI
Owner: STEINMULLER MICHAEL & CLAUDIA STEINMULLER JTWROS

Address

860 HILLCREST DRIVE

ORIENT, NY 11957

Lot: 0710
Contracted Stated Job Value: ¤340,000.00
Job Description: Single Family Residence
Type: CN

Contractor

SEAGATE HOMES, LLC
Status Location Address Mailing Address State License Number Phone
ACTIVE

185 CYPRESS POINT PARKWAY

Palm Coast, FL 32137

SUITE 7

Palm Coast, FL 32137

CGC1518372 (Exp: 08/31/2026) 386-246-6132

Sub Contractors

RICHARD H SIMMONS JR
Status Location Address State License Number Phone Fax
ACTIVE

PO BOX 1963

BUNNELL, FL 32110

ES12001217 (Exp: 08/31/2026) 386-437-0607 386-437-1847
ANDREW SCOTT DIGAETANO JR
Status Location Address State License Number Phone
ACTIVE

44 FORT CAROLINE

PALM COAST, FL 32137

CCC1331606 (Exp: 08/31/2026) 386-302-9063
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
DONALD WALLS JR
Status Location Address State License Number Phone
INACTIVE

2860 S US HIGHWAY 17

, 0

LQ35326 (Exp: 04/04/2025) 386-698-1033
DENNIS GENE GAINEY
Status Location Address State License Number Phone Fax
INACTIVE

P.O. BOX 1203

Bunnell, FL 32110

CFC046004 (Exp: 08/31/2026) (386) 437-5637 386-437-3012

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/15/2024 FINAL APPROVED JWALKER
ROW - FINAL APRON (AFTER POUR) 05/13/2024 APPROVED EMADISON
Note: ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved.
ROW - STORMWATER FINAL 05/13/2024 APPROVED EMADISON
Note: ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved.
U -UTILITY RESIDENTIAL FINAL 05/09/2024 FINAL APPROVED LFITZGERALD
U-CROSS CONNECTION 05/09/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 5/9/2024 2:24:03 PM *** has potable irrigation with PVB-no cross connectin
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/08/2024 APPROVED EMADISON
Note: Inspector Notes from Inspection 9270 4/15/24 PIPE IS GOOD. YOU NEED TO TURN DOWN THE CULVERT PIPE BAND BOLTS SO THE ARE NOT IN THE POUR AT TOP OF PIPE. FOR FUTURE REFERENCE YOU NEED TO HAVE THE CUVERT END FOOTERS NO LONGER THAN 6" IN LENGTH TO THE BACK FORMBOARD. THEY ARE A BIT LONG. OTHERWISE YOU WILL BE CUTTING THE ADDITIONAL OVERPOUR OUT LATER. APPROVING TJIS INSPECTION AS NOTED. MAKE SURE YOU TURN THE BOLTS. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
ROW FIELD SURVEY /GRADING CERTIFICATION 05/08/2024 APPROVED - AS NOTED EMADISON
Note: *** NOTES ADDED BY EMADISON 5/8/2024 9:12:51 AM *** ** 05/08/24 ALONG RIGHT SIDE PROPERTY LINE OF VACANT BUILDER NEEDS TO CREATE A 2:1 BEFORE THE ROW FINAL IN APPROVED (NOTE AREAS OF WHITE PAINT)
ELEVATION CERTIFICATE-FINAL APPROVAL 05/08/2024 APPROVED JMYERS
ROW- PRE-APRON (PRE-POUR) 04/15/2024 APPROVED - AS NOTED FSLADISH
Note: 4/15/24 PIPE IS GOOD. YOU NEED TO TURN DOWN THE CULVERT PIPE BAND BOLTS SO THE ARE NOT IN THE POUR AT TOP OF PIPE. FOR FUTURE REFERENCE YOU NEED TO HAVE THE CUVERT END FOOTERS NO LONGER THAN 6" IN LENGTH TO THE BACK FORMBOARD. THEY ARE A BIT LONG. OTHERWISE YOU WILL BE CUTTING THE ADDITIONAL OVERPOUR OUT LATER. APPROVING TJIS INSPECTION AS NOTED. MAKE SURE YOU TURN THE BOLTS. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
ELECTRIC - EARLY POWER 03/12/2024 APPROVED AGAETANO
LATH/BRICK/ WATER BARRIER 02/23/2024 APPROVED AGAETANO
INSULATION 01/29/2024 APPROVED AGAETANO
ALL ROUGH 01/25/2024 APPROVED AGAETANO
Note: 01-25-2024 Gas rough inspected and approved.
WALL SHEATHING 01/18/2024 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/18/2024 APPROVED AGAETANO
ROOF VALLEY & METAL 01/18/2024 APPROVED AGAETANO
ELEV CERT-FOUNDATION APPROVAL 01/17/2024 APPROVED JMYERS
Note: The Foundation elevation certificate has been approved. Please provide Final prior to receiving CO.
TIE BEAM / LINTEL 12/21/2023 APPROVED AGAETANO
Note: 12/20/2023 - PREVIOUS INSPECTION NOTES 12-20-2023 1. Missed dowel 2. Clearance of rebar not met at CMU. Please see highlighted notes on drawings.
TIE BEAM / LINTEL 12/20/2023 Disapproved - NO FEE AGAETANO
Note: 12-20-2023 1. Missed dowel 2. Clearance of rebar not met at CMU. Please see highlighted notes on drawings.
FOUND SURVEY APPROVED (OFFICE) 12/15/2023 APPROVED TBAKER
MONOLITHIC SLAB 12/01/2023 APPROVED AGAETANO
Note: 11/30/2023 - PREVIOUS INSPECTION NOTES 11/29/2023 - PREVIOUS INSPECTION NOTES 11/28/2023 - PREVIOUS INSPECTION NOTES 11-28-23 1. Drill and epoxy bottom rebar of turn down footing into stem wall footing. Left side of building. ( Shower area). 2. UFER not visible. 3. Please tamp area. Check all. 4. Clearance on rebar. Check all. 5. Plumbing lines over column pad. Inspection stopped. 11-29-2023 Above issue not resolved. Plumbing lines installed over coulmn pad. Highlighted on previous inspection.
MONOLITHIC SLAB 11/30/2023 CANCELLED BY APPLICANT AGAETANO
Note: 11/29/2023 - PREVIOUS INSPECTION NOTES 11/28/2023 - PREVIOUS INSPECTION NOTES 11-28-23 1. Drill and epoxy bottom rebar of turn down footing into stem wall footing. Left side of building. ( Shower area). 2. UFER not visible. 3. Please tamp area. Check all. 4. Clearance on rebar. Check all. 5. Plumbing lines over column pad. Inspection stopped. 11-29-2023 Above issue not resolved. Plumbing lines installed over coulmn pad. Highlighted on previous inspection.
MONOLITHIC SLAB 11/29/2023 Disapproved -FEE REQUIRED AGAETANO
Note: 11/28/2023 - PREVIOUS INSPECTION NOTES 11-28-23 1. Drill and epoxy bottom rebar of turn down footing into stem wall footing. Left side of building. ( Shower area). 2. UFER not visible. 3. Please tamp area. Check all. 4. Clearance on rebar. Check all. 5. Plumbing lines over column pad. Inspection stopped. 11-29-2023 Above issue not resolved. Plumbing lines installed over coulmn pad. Highlighted on previous inspection.
MONOLITHIC SLAB 11/28/2023 Disapproved - NO FEE AGAETANO
Note: 11-28-23 1. Drill and epoxy bottom rebar of turn down footing into stem wall footing. Left side of building. ( Shower area). 2. UFER not visible. 3. Please tamp area. Check all. 4. Clearance on rebar. Check all. 5. Plumbing lines over column pad. Inspection stopped.
PLUMBING 1ST ROUGH UNDERGROUND 11/13/2023 APPROVED MGIBSON
GRAVITY SEWER TEST 11/13/2023 APPROVED MGIBSON
U - SEWER TIE IN 11/13/2023 APPROVED MGIBSON
DOWN CELL 08/31/2023 APPROVED FWILLIS
STEM WALL FOUNDATION 08/10/2023 Disapproved - NO FEE BTAYLOR
Note: 8-10-23 1. Stemwall is not built per detail.
STEM WALL FOUNDATION 08/10/2023 APPROVED BTAYLOR
Note: 8/10/2023 - PREVIOUS INSPECTION NOTES 8-10-23 1. Stemwall is not built per detail.
WATER METER INSTALLATION REQUEST 07/24/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
PLFM COMPLETE 05/07/2024 05/08/2024
Note: Released By: JERRY REITER - - JREITER@PALMCOASTGOV.COM Final Elevation certificate has been approved.
PLFM COMPLETE 01/16/2024 01/17/2024
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM The Foundation elevation certificate has been approved. Please provide Final prior to receiving CO.
ENGIN1 COMPLETE 12/14/2023 12/15/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/14/2023 12/15/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD COMPLETE 10/30/2023 11/02/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 09/20/2023 09/22/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 09/20/2023 09/25/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 08/24/2023 08/31/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLFM COMPLETE 08/01/2023 08/02/2023
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM The additional construction elevation certificate was rejected, one was already approved.
GAS COMPLETE 06/23/2023 06/23/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLFM CANCEL 06/23/2023 06/23/2023
ZON COMPLETE 06/23/2023 06/23/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
PLFM COMPLETE 06/21/2023 06/22/2023
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM The construction elevation certificate has been approved. Please provide foundation and final prior to receiving CO.
GAS HOLD 06/21/2023 06/23/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide BTUs for appliances on gas riser diagram. (Second Request) Gas riser not uploaded. Elevation cert was uploaded and named gas riser diagram
BLD COMPLETE 06/15/2023 06/20/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 06/15/2023 06/21/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 06/15/2023 06/20/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/15/2023 06/15/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS HOLD 06/15/2023 06/20/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide BTUs for appliances on gas riser diagram
LOCATE COMPLETE 06/15/2023 06/20/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 06/15/2023 06/20/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/15/2023 06/21/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 06/15/2023 06/16/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
PLFM HOLD 06/15/2023 06/16/2023
Note: Held By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM According to the Site Plan submitted, the structure will fall inside the Special Flood Hazard Area. Elevation Certificates will be required at construction drawings, foundation, and final.
SWALE COMPLETE 06/15/2023 07/28/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 05/15/2024
PLAN REVIEW - REVISION ¤32.50 05/15/2024
REINSPECTION RESIDENTIAL ¤40.00 05/15/2024
CONNECTION FEES ¤1,166.26 06/27/2023
FIRE IMPACT FEE ADMIN ¤12.62 06/27/2023
FIRE IMPACT FEE ADMIN (¤12.62) 06/27/2023
FC IMPACT FEE EMS ¤62.00 06/27/2023
IMPACT FEE FIRE ¤420.52 06/27/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 06/27/2023
FC IMPACT FEE LIBRARY ¤268.00 06/27/2023
IMPACT FEE PARKS ¤1,769.15 06/27/2023
IMPACT FEE SCHOOL ¤5,450.00 06/27/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 06/27/2023
WATER -IRRIGATION INSPECTION ¤25.00 06/27/2023
PARKS IMPACT FEE ADMIN ¤53.07 06/27/2023
PARKS IMPACT FEE ADMIN (¤53.07) 06/27/2023
SURCHARGE FS 533.721 ¤6.15 06/27/2023
SURCHARGE - FS 468.631 ¤9.23 06/27/2023
SW ENG - FOUNDATION SURVEY ¤20.00 06/27/2023
SW ENG INSPECTION 80 ¤80.00 06/27/2023
SW ENG PRE APRON ¤30.00 06/27/2023
SW ENG - REVIEW 20 ¤20.00 06/27/2023
SW ENG RES REVIEW 200 ¤200.00 06/27/2023
TRANS IMPACT FEE ADMIN ¤54.36 06/27/2023
TRANS IMPACT FEE ADMIN (¤54.36) 06/27/2023
SEWER CREDIT (¤1,147.00) 06/27/2023
SEWER INSPECTION ¤25.00 06/27/2023
SEWER CAPITAL FACILITY ¤5,344.82 06/27/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 06/27/2023
SITE PLAN 30 ¤30.00 06/27/2023
WATER- TURN ON ¤25.00 06/27/2023
ADJUSTMENT 50% (¤615.10) 06/27/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 06/27/2023
INSPECTION - RESIDENTIAL ¤935.00 06/27/2023
PLAN REVIEW - RESIDENTIAL ¤265.20 06/27/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,478.11