I want to search for...
Permit #2023060807
Permit Details
Status: COED
| Parcel Id: 28-10-30-5415-00000-1100 |
| CONDITIONED SPACE: 2147 sqft |
| GARAGE: 557 sqft |
| OPENED PORCH (WITH ROOF) : 54 sqft |
| SCREEN PORCH (SOLID ROOF) : 131 sqft |
| Total Square Footage: 2889 sqft |
| Subdivision: 2310 - SAWMILL BRANCH 2A |
| Job Phone: 904-219-3385 |
| Location Address: 20 SAWMILL CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/10/2023 |
| NOC: RECORDED |
| Applicant name: RAYMOND CLIVE CROSBY |
| Owner: DR HORTON, INC |
|
Address 4220 RACE TRACK RD ST JOHNS, FL 32259 |
| Lot: 110 |
| Contracted Stated Job Value: ¤214,700.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
DR HORTON, INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
4220 RACE TRACK RD SAINT JOHNS, FL 32259 |
CBC058997 (Exp: 08/31/2026) | 904-268-2845 | 904-899-5992 |
Sub Contractors
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
JAMES M GREENSLADE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
311 S BAY ST BUNNELL, FL 32110 |
EC13006083 (Exp: 08/31/2026) | 386-263-2960 | 386-263-2980 |
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/11/2024 | FINAL APPROVED | JSTEWART |
| Note: 1/4/2024 - PREVIOUS INSPECTION NOTES 1. Cat5 needs to be sealed @ siding by metermain 2. ODU disconnect can not be behind unit 3. Drip edge is damaged/bent on front of home and needs to be sealed where it meets siding Stopped inspection outside not ready | |||
| U-CROSS CONNECTION | 01/04/2024 | APPROVED - AS NOTED | JHARDING |
| Note: No cross connections. | |||
| BLD - BUILDING FINAL | 01/04/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Cat5 needs to be sealed @ siding by metermain 2. ODU disconnect can not be behind unit 3. Drip edge is damaged/bent on front of home and needs to be sealed where it meets siding Stopped inspection outside not ready | |||
| ROW - STORMWATER FINAL | 01/04/2024 | APPROVED | TPOLACEK |
| Note: 01/04/24 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. _______________________________________________________________________ 12/27/2023 - PREVIOUS INSPECTION NOTES 12/27/23 ** STILL NEED TO CLEAN UP TRASH BY FRONT DOOR ** WASHOUT IN RIGHT REAR NOW PAINTED NEEDS TO FIXED BEFORE INSPECTION WILL PASS. Inspector Notes from Inspection 9272 Before Final Stormwater can be approved. *Steet and gutter needs cleaned *Washout at the rear right property line needs repaired *Trash all around the pond needs removed. *and whatever else may happen between now and the Stormwater Final | |||
| U -UTILITY RESIDENTIAL FINAL | 12/27/2023 | FINAL APPROVED | DHANEY |
| ROW - STORMWATER FINAL | 12/27/2023 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 12/27/23 ** STILL NEED TO CLEAN UP TRASH BY FRONT DOOR ** WASHOUT IN RIGHT REAR NOW PAINTED NEEDS TO FIXED BEFORE INSPECTION WILL PASS. Inspector Notes from Inspection 9272 Before Final Stormwater can be approved. *Steet and gutter needs cleaned *Washout at the rear right property line needs repaired *Trash all around the pond needs removed. *and whatever else may happen between now and the Stormwater Final | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/21/2023 | APPROVED | RGROSS |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/21/2023 | APPROVED | RGROSS |
| ROW - FINAL APRON (AFTER POUR) | 12/21/2023 | APPROVED - AS NOTED | RGROSS |
| Note: Before Final Stormwater can be approved. *Steet and gutter needs cleaned *Washout at the rear right property line needs repaired *Trash all around the pond needs removed. *and whatever else may happen between now and the Stormwater Final | |||
| ELECTRIC - EARLY POWER | 12/01/2023 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2200 9/29/23- Authorize release of email to FPL @ 11:13a. | |||
| ROW- PRE-APRON (PRE-POUR) | 11/29/2023 | APPROVED | GBERTOLA |
| Note: READY TO POUR MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVERT DETAIL | |||
| U - SEWER TIE IN | 11/07/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 11/07/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| INSULATION | 10/25/2023 | APPROVED | RSIMS |
| Note: 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23: Not Ready! Walked with Superintendent. 10/19/2023 - PREVIOUS INSPECTION NOTES 10/19/23:10/19/23: Inspection Stopped! Not Ready! Firestop missing in too many places to identify all. I had previously walked an Insulation Inspection (at another location) with the Superintendent & the Assistant Superintendent to identify all of the required locations. Examples: Missing Firestop * at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Some areas marked on studs with FS where required. * at cross bracing where ceiling elevation changes. * One location in garage. 10/18/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 10/11/23- Missing rear SGD, added a window nailing inspection. (Please do not trim, need to verify water barrier (flashing). Please block opening at insulation with plywood or plastic. No water preassure in building. P2503.7 WATER SUPPLY-SYSTEM TESTING Will check at insulation. | |||
| INSULATION | 10/23/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 10/23/23: Not Ready! Walked with Superintendent. 10/19/2023 - PREVIOUS INSPECTION NOTES 10/19/23:10/19/23: Inspection Stopped! Not Ready! Firestop missing in too many places to identify all. I had previously walked an Insulation Inspection (at another location) with the Superintendent & the Assistant Superintendent to identify all of the required locations. Examples: Missing Firestop * at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Some areas marked on studs with FS where required. * at cross bracing where ceiling elevation changes. * One location in garage. 10/18/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 10/11/23- Missing rear SGD, added a window nailing inspection. (Please do not trim, need to verify water barrier (flashing). Please block opening at insulation with plywood or plastic. No water preassure in building. P2503.7 WATER SUPPLY-SYSTEM TESTING Will check at insulation. | |||
| INSULATION | 10/19/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 10/19/23:10/19/23: Inspection Stopped! Not Ready! Firestop missing in too many places to identify all. I had previously walked an Insulation Inspection (at another location) with the Superintendent & the Assistant Superintendent to identify all of the required locations. Examples: Missing Firestop * at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Some areas marked on studs with FS where required. * at cross bracing where ceiling elevation changes. * One location in garage. 10/18/2023 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2420 10/11/23- Missing rear SGD, added a window nailing inspection. (Please do not trim, need to verify water barrier (flashing). Please block opening at insulation with plywood or plastic. No water preassure in building. P2503.7 WATER SUPPLY-SYSTEM TESTING Will check at insulation. | |||
| WINDOW NAILING | 10/19/2023 | APPROVED | RSIMS |
| Note: Inspector Notes from Inspection 2420 10/11/23- Missing rear SGD, added a window nailing inspection. (Please do not trim, need to verify water barrier (flashing). Please block opening at insulation with plywood or plastic. No water preassure in building. P2503.7 WATER SUPPLY-SYSTEM TESTING Will check at insulation. | |||
| LATH/BRICK/ WATER BARRIER | 10/11/2023 | APPROVED - AS NOTED | JSTEWART |
| Note: 10/11/23- Added a window nailing inspection for rear SGD. Please block opening with plywood or plastic. Please donot trim until nailing inspection is aproved (Nailing and Flashing). | |||
| ALL ROUGH | 10/11/2023 | APPROVED - AS NOTED | JSTEWART |
| Note: 10/11/23- Missing rear SGD, added a window nailing inspection. (Please do not trim, need to verify water barrier (flashing). Please block opening at insulation with plywood or plastic. No water preassure in building. P2503.7 WATER SUPPLY-SYSTEM TESTING Will check at insulation. | |||
| ELECTRIC-TUG | 09/29/2023 | APPROVED - AS NOTED | JSTEWART |
| Note: 9/29/23- Authorize release of email to FPL @ 11:13a. | |||
| ROOF VALLEY & METAL | 09/29/2023 | APPROVED | JSTEWART |
| WALL SHEATHING | 09/21/2023 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2470 Plywood only, No anchors or strapps have been installed check at tie down inspection | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/21/2023 | APPROVED | JSTEWART |
| Note: Inspector Notes from Inspection 2470 Plywood only, No anchors or strapps have been installed check at tie down inspection | |||
| FOUND SURVEY APPROVED (OFFICE) | 09/20/2023 | APPROVED | TBAKER |
| SHEARWALL | 09/12/2023 | APPROVED - AS NOTED | MKRASKI |
| Note: Plywood only, No anchors or strapps have been installed check at tie down inspection | |||
| MONOLITHIC SLAB | 08/22/2023 | APPROVED | TSTAUFFACHER |
| PLUMBING 1ST ROUGH UNDERGROUND | 08/17/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 07/24/2023 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 09/20/2023 | 09/20/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/20/2023 | 09/20/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/10/2023 | 07/10/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 06/16/2023 | 07/05/2023 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/15/2023 | 06/16/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 06/15/2023 | 06/16/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/15/2023 | 06/20/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/15/2023 | 06/15/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/15/2023 | 06/20/2023 |
| LOCATE | COMPLETE | 06/15/2023 | 06/20/2023 |
| Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/15/2023 | 06/20/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Heatload does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2020 7Th Edition | |||
| SW1 | COMPLETE | 06/15/2023 | 06/22/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/15/2023 | 06/16/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/11/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/11/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 01/11/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/10/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/10/2023 |
| TRANS IMPACT FEE ADMIN | ¤99.33 | 07/10/2023 |
| TRANS IMPACT FEE ADMIN | (¤99.33) | 07/10/2023 |
| SEWER INSPECTION | ¤25.00 | 07/10/2023 |
| SEWER CAPITAL FACILITY | ¤2,803.23 | 07/10/2023 |
| WATER CAPITAL FACILITY FEE | ¤2,605.24 | 07/10/2023 |
| SITE PLAN 30 | ¤30.00 | 07/10/2023 |
| WATER-METER | ¤505.39 | 07/10/2023 |
| WATER-METER | ¤419.86 | 07/10/2023 |
| ADJUSTMENT 50% | (¤489.79) | 07/10/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/10/2023 |
| INSPECTION - RESIDENTIAL | ¤739.75 | 07/10/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤209.82 | 07/10/2023 |
| CONNECTION FEES | ¤25.00 | 07/10/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 07/10/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 07/10/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 07/10/2023 |
| IMPACT FEE FIRE | ¤420.52 | 07/10/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/10/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/10/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 07/10/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 07/10/2023 |
| IMPACT FEE TRANSPORTATION | ¤3,311.00 | 07/10/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/10/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 07/10/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 07/10/2023 |
| SURCHARGE FS 533.721 | ¤4.90 | 07/10/2023 |
| SURCHARGE - FS 468.631 | ¤7.35 | 07/10/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/10/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/10/2023 |
| SW ENG PRE APRON | ¤30.00 | 07/10/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤18,889.42 |