Permit #2023060820

Permit Details

Status: COED

Parcel Id: 28-10-30-5415-00000-1840
CONDITIONED SPACE: 2353 sqft
GARAGE: 560 sqft
OPENED PORCH (WITH ROOF) : 30 sqft
SCREEN PORCH (SOLID ROOF) : 207 sqft
Total Square Footage: 3150 sqft
Subdivision: 2310 - SAWMILL BRANCH 2A
Job Phone: 904-219-3385
Location Address: 31 LUMBER JACK TR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/12/2023
NOC: RECORDED
Applicant name: RAYMOND CLIVE CROSBY
Owner: DR HORTON, INC

Address

4220 RACE TRACK RD

ST JOHNS, FL 32259

Lot: 184
Contracted Stated Job Value: ¤235,300.00
Job Description: SINGLE FAMILY
Type: CN

Contractor

DR HORTON, INC.
Status Location Address State License Number Phone Fax
ACTIVE

4220 RACE TRACK RD

SAINT JOHNS, FL 32259

CBC058997 (Exp: 08/31/2026) 904-268-2845 904-899-5992

Sub Contractors

EDWARD DOUGLAS TENNANT
Status Location Address State License Number Phone Fax
INACTIVE

3370 AGRICULTURAL CENTER DRIVE

ST. AUGUSTINE , FL 32092

CAC1813372 (Exp: 08/31/2026) (904)829-8898 (904)829-6587
PAUL ERIC FORSTER
Status Location Address State License Number Phone
ACTIVE

6114 GOODMAN RD

JACKSONVILLE, FL 32244

CFC1429261 (Exp: 08/31/2026) 904-647-1820
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
JAMES M GREENSLADE
Status Location Address State License Number Phone Fax
ACTIVE

311 S BAY ST

BUNNELL, FL 32110

EC13006083 (Exp: 08/31/2026) 386-263-2960 386-263-2980

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 12/07/2023 APPROVED RSIMS
Note: 12/1/2023 - PREVIOUS INSPECTION NOTES 12/1/23- 1. Master Toilet room Exhaust fan not working. M1507.2 Recirculation of air. 2. UNIT LABELING..FBC.R. M1303.1 MUST IDENTIFY MAXIMUM OVER CURRENT BREAKER SIZE ON AIR HANDLER AND OR CONDENSOR UNIT WITH FACTORY APPLIED LABEL
BLD - BUILDING FINAL 12/01/2023 Disapproved - NO FEE JSTEWART
Note: 12/1/23- 1. Master Toilet room Exhaust fan not working. M1507.2 Recirculation of air. 2. UNIT LABELING..FBC.R. M1303.1 MUST IDENTIFY MAXIMUM OVER CURRENT BREAKER SIZE ON AIR HANDLER AND OR CONDENSOR UNIT WITH FACTORY APPLIED LABEL
U-CROSS CONNECTION 11/20/2023 APPROVED DHANEY
U -UTILITY RESIDENTIAL FINAL 11/20/2023 FINAL APPROVED DHANEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 11/17/2023 APPROVED EMADISON
ROW FIELD SURVEY /GRADING CERTIFICATION 11/17/2023 APPROVED EMADISON
ROW - STORMWATER FINAL 11/17/2023 APPROVED EMADISON
ROW - FINAL APRON (AFTER POUR) 11/17/2023 APPROVED EMADISON
ELECTRIC - EARLY POWER 11/07/2023 APPROVED JSTEWART
Note: Inspector Notes from Inspection 2200 9/11/23-Authorize release of email to FPL @ 10:48a.
ROW- PRE-APRON (PRE-POUR) 10/30/2023 APPROVED PFLANAGAN
Note: ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARTS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
INSULATION 10/02/2023 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 9/20/23- Please make sure smoke detector in hallway is 4" away from wall. smoke detector in front bedroom at peak of vaulted ceiling needs to be 4" min from the center of the vault, Before Final. 9/12/2023 - PREVIOUS INSPECTION NOTES 1. Windows installed do not match product approval number revision is required 2. Dryer vent seam is not sealed 3. Chase for island power requires nail plate (wall side) 4. Structual studs have been cut at washer hook up. enginnered letter for repair is required to be submitted and apporved by Building dept. Stopped inspection not ready
GRAVITY SEWER TEST 09/22/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 09/22/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ALL ROUGH 09/20/2023 APPROVED - AS NOTED JSTEWART
Note: 9/20/23- Please make sure smoke detector in hallway is 4" away from wall. smoke detector in front bedroom at peak of vaulted ceiling needs to be 4" min from the center of the vault, Before Final. 9/12/2023 - PREVIOUS INSPECTION NOTES 1. Windows installed do not match product approval number revision is required 2. Dryer vent seam is not sealed 3. Chase for island power requires nail plate (wall side) 4. Structual studs have been cut at washer hook up. enginnered letter for repair is required to be submitted and apporved by Building dept. Stopped inspection not ready
LATH/BRICK/ WATER BARRIER 09/12/2023 Disapproved - NO FEE MKRASKI
Note: 1. Back porch beam is missing water barrier
LATH/BRICK/ WATER BARRIER 09/12/2023 APPROVED MKRASKI
ALL ROUGH 09/12/2023 Disapproved - NO FEE MKRASKI
Note: 1. Windows installed do not match product approval number revision is required 2. Dryer vent seam is not sealed 3. Chase for island power requires nail plate (wall side) 4. Structual studs have been cut at washer hook up. enginnered letter for repair is required to be submitted and apporved by Building dept. Stopped inspection not ready
ELECTRIC-TUG 09/11/2023 APPROVED - AS NOTED JSTEWART
Note: 9/11/23-Authorize release of email to FPL @ 10:48a.
ROOF VALLEY & METAL 08/28/2023 APPROVED RSIMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/25/2023 APPROVED TSTAUFFACHER
Note: 8/24/2023 - PREVIOUS INSPECTION NOTES 98/24/2023- Prior notes not done 8/22/2023 - PREVIOUS INSPECTION NOTES 8/22/23: Roof sheathing bump checked/ Ties checked - approved Truss Engineering - Disapproved 1). Truss T14 (all 6) are missing one piece of engineering in the center & the installed engineering pieces are on the wrong webs per MiTek. 2). Trusses T63 & T64 are missing engineering per MiTek. Marked on MiTek.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/24/2023 Disapproved -FEE REQUIRED TSTAUFFACHER
Note: 98/24/2023- Prior notes not done 8/22/2023 - PREVIOUS INSPECTION NOTES 8/22/23: Roof sheathing bump checked/ Ties checked - approved Truss Engineering - Disapproved 1). Truss T14 (all 6) are missing one piece of engineering in the center & the installed engineering pieces are on the wrong webs per MiTek. 2). Trusses T63 & T64 are missing engineering per MiTek. Marked on MiTek.
WALL SHEATHING 08/22/2023 APPROVED RSIMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 08/22/2023 PARTIALLY APPROVED RSIMS
Note: 8/22/23: Roof sheathing bump checked/ Ties checked - approved Truss Engineering - Disapproved 1). Truss T14 (all 6) are missing one piece of engineering in the center & the installed engineering pieces are on the wrong webs per MiTek. 2). Trusses T63 & T64 are missing engineering per MiTek. Marked on MiTek.
FOUND SURVEY APPROVED (OFFICE) 08/03/2023 APPROVED TBAKER
MONOLITHIC SLAB 07/27/2023 APPROVED FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 07/24/2023 APPROVED JSTEWART
WATER METER INSTALLATION REQUEST 07/13/2023 APPROVED CSTONE

Review History

Department Status Date In Date Out
BLD COMPLETE 09/14/2023 09/15/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/03/2023 08/03/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 08/03/2023 08/03/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 07/14/2023 07/14/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ZON COMPLETE 07/10/2023 07/10/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 07/10/2023 07/11/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
URB COMPLETE 06/16/2023 07/06/2023
Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM
BLD COMPLETE 06/15/2023 06/16/2023
Note: Released By: JPI
CUSVC COMPLETE 06/15/2023 06/16/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 06/15/2023 06/20/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 06/15/2023 06/16/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 06/15/2023 06/20/2023
LOCATE COMPLETE 06/15/2023 06/20/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
MECH HOLD 06/15/2023 06/20/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Heatload does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2020 7Th Edition
SW1 COMPLETE 06/15/2023 06/21/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 06/15/2023 06/20/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM going forward please check one of the boxes that states no more than 2 accent colors.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/07/2023
CONNECTION FEES ¤25.00 07/12/2023
FIRE IMPACT FEE ADMIN ¤12.62 07/12/2023
FIRE IMPACT FEE ADMIN (¤12.62) 07/12/2023
FC IMPACT FEE EMS ¤62.00 07/12/2023
IMPACT FEE FIRE ¤420.52 07/12/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/12/2023
FC IMPACT FEE LIBRARY ¤268.00 07/12/2023
IMPACT FEE PARKS ¤1,769.15 07/12/2023
IMPACT FEE SCHOOL ¤5,450.00 07/12/2023
IMPACT FEE TRANSPORTATION ¤3,311.00 07/12/2023
WATER -IRRIGATION INSPECTION ¤25.00 07/12/2023
PARKS IMPACT FEE ADMIN ¤53.07 07/12/2023
PARKS IMPACT FEE ADMIN (¤53.07) 07/12/2023
SURCHARGE FS 533.721 ¤5.34 07/12/2023
SURCHARGE - FS 468.631 ¤8.01 07/12/2023
SW ENG - FOUNDATION SURVEY ¤20.00 07/12/2023
SW ENG INSPECTION 80 ¤80.00 07/12/2023
SW ENG PRE APRON ¤30.00 07/12/2023
SW ENG - REVIEW 20 ¤20.00 07/12/2023
SW ENG RES REVIEW 200 ¤200.00 07/12/2023
TRANS IMPACT FEE ADMIN ¤99.33 07/12/2023
TRANS IMPACT FEE ADMIN (¤99.33) 07/12/2023
SEWER INSPECTION ¤25.00 07/12/2023
SEWER CAPITAL FACILITY ¤2,803.23 07/12/2023
WATER CAPITAL FACILITY FEE ¤2,605.24 07/12/2023
SITE PLAN 30 ¤30.00 07/12/2023
WATER-METER ¤505.39 07/12/2023
WATER-METER ¤419.86 07/12/2023
ADJUSTMENT 50% (¤533.91) 07/12/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/12/2023
INSPECTION - RESIDENTIAL ¤808.50 07/12/2023
PLAN REVIEW - RESIDENTIAL ¤229.32 07/12/2023
Fees Total Due: ¤0.00 Total Paid: ¤18,874.65