I want to search for...

Permit #2023060822

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7037-01350-0290
CONDITIONED SPACE: 649 sqft
OPENED PORCH (WITH ROOF) : 44 sqft
OPENED PORCH (WITH ROOF) : 42 sqft
Total Square Footage: 735 sqft
Block: 01350
Subdivision: 2176 - SECTION 37-LAKEVIEW
Job Phone: 386-547-2095
Location Address: 51 LONDON DR
Type: BA - BUILDING ADDITION
Issue Date: 07/27/2023
NOC: RECORDED
Applicant name: GEORGE FREDERICH BURTON III
Owner: KELSKE BRIAN J & CHRISTI L H&W

Address

51 LONDON DRIVE

PALM COAST, FL 32137

Lot: 0290
Contracted Stated Job Value: ¤94,450.00
Job Description: ADDITION
Type: CN

Contractor

GEORGE BURTON CONSTRUCTION, INC
Status Location Address State License Number Phone Fax
ACTIVE

1 SUNNY ROAD

ORMOND BEACH, FL 32173

CGC1515993 (Exp: 08/31/2026) 386-676-2837 386-672-2897

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/23/2024 FINAL APPROVED JSTEWART
Note: 2/20/2024 - PREVIOUS INSPECTION NOTES 1. Entry door requires a switched lightoutside door 2. Exteior outlets/GFCi are required to be the weather resisant type 3. Smoke detectors need to have back up battery installed 4. No hot water
U -UTILITY RESIDENTIAL FINAL 02/23/2024 FINAL APPROVED DHANEY
Note: 2/20/2024 - PREVIOUS INSPECTION NOTES Drive not completed - Call back when completed .
BLD - BUILDING FINAL 02/20/2024 Disapproved - NO FEE MKRASKI
Note: 1. Entry door requires a switched lightoutside door 2. Exteior outlets/GFCi are required to be the weather resisant type 3. Smoke detectors need to have back up battery installed 4. No hot water
U -UTILITY RESIDENTIAL FINAL 02/20/2024 CANCELLED BY APPLICANT DHANEY
Note: Drive not completed - Call back when completed .
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/16/2024 APPROVED GBERTOLA
Note: 2/16/24=AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 2/9/2024 - PREVIOUS INSPECTION NOTES ** 02/09/24 Finished Floor Elevations (FFE): Site Plan must include the FFE of the subject property as well as the FFE of any adjacent developed properties. (A) Land Development Code Technical Manual, Section 300.01 (A)(1)(B)(3) ** Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A)Land Development Code Technical Manual, Section 300.01 (A)(1)(B)(4) ** Elevations on all adjacent property lines at 20-foot intervals. (B)Land Development Code Technical Manual, Section 300.01 (A)(1)(B)(5) **
ROW FIELD SURVEY /GRADING CERTIFICATION 02/16/2024 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR.
ROW - FINAL INSPECTION 02/16/2024 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. HOMEOWNER WILL INSTALL PAVERS AROUND THE HOUSE
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/09/2024 Disapproved - NO FEE EMADISON
Note: ** 02/09/24 Finished Floor Elevations (FFE): Site Plan must include the FFE of the subject property as well as the FFE of any adjacent developed properties. (A) Land Development Code Technical Manual, Section 300.01 (A)(1)(B)(3) ** Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A)Land Development Code Technical Manual, Section 300.01 (A)(1)(B)(4) ** Elevations on all adjacent property lines at 20-foot intervals. (B)Land Development Code Technical Manual, Section 300.01 (A)(1)(B)(5) **
LATH/BRICK/ WATER BARRIER 12/22/2023 APPROVED FWILLIS
INSULATION 12/13/2023 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 1. Exterior door have not been installed 2. Must submit exterior siding to building dept. and be approved before next inspection Check on next inspection
ALL ROUGH 12/04/2023 APPROVED - AS NOTED MKRASKI
Note: 1. Exterior door have not been installed 2. Must submit exterior siding to building dept. and be approved before next inspection Check on next inspection
ROOF VALLEY & METAL 11/16/2023 APPROVED FWILLIS
WALL SHEATHING 11/13/2023 APPROVED JSTEWART
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/13/2023 APPROVED JSTEWART
DOWN CELL 11/08/2023 APPROVED FWILLIS
TIE BEAM / LINTEL 10/26/2023 APPROVED FWILLIS
Note: 10/24/2023 - PREVIOUS INSPECTION NOTES 10/24/23: Marked on Plans * Pin into existing house is not epoxied as required & previously identified on 10/20/23. * Down rod is not tied to dowel as required. (corner of entry where new dowel was installed). 10/20/2023 - PREVIOUS INSPECTION NOTES 10/20/23- Multiple footing dowels need relocated for min 3/4' emedment. R606.13.4 CLEARANCE FROM MASONRY Multiple reinforcement tie ins to existing masonry need to be epoxied and secured (marked on walls).
TIE BEAM / LINTEL 10/24/2023 Disapproved -FEE REQUIRED RSIMS
Note: 10/24/23: Marked on Plans * Pin into existing house is not epoxied as required & previously identified on 10/20/23. * Down rod is not tied to dowel as required. (corner of entry where new dowel was installed). 10/20/2023 - PREVIOUS INSPECTION NOTES 10/20/23- Multiple footing dowels need relocated for min 3/4' emedment. R606.13.4 CLEARANCE FROM MASONRY Multiple reinforcement tie ins to existing masonry need to be epoxied and secured (marked on walls).
TIE BEAM / LINTEL 10/20/2023 Disapproved - NO FEE JSTEWART
Note: 10/20/23- Multiple footing dowels need relocated for min 3/4' emedment. R606.13.4 CLEARANCE FROM MASONRY Multiple reinforcement tie ins to existing masonry need to be epoxied and secured (marked on walls).
MONOLITHIC SLAB 09/28/2023 APPROVED FWILLIS
Note: 9/26/2023 - PREVIOUS INSPECTION NOTES 9/26/23- Do to weather........Please clean out large cave in under barrier covering Footing reinforcement. R404.1.2.3.7.4 9/15/2023 - PREVIOUS INSPECTION NOTES PROOF OF COMPACTION NEEDED. INSTALL UFER GROUND.
MONOLITHIC SLAB 09/26/2023 Disapproved - NO FEE JSTEWART
Note: 9/26/23- Do to weather........Please clean out large cave in under barrier covering Footing reinforcement. R404.1.2.3.7.4 9/15/2023 - PREVIOUS INSPECTION NOTES PROOF OF COMPACTION NEEDED. INSTALL UFER GROUND.
MONOLITHIC SLAB 09/15/2023 Disapproved - NO FEE FWILLIS
Note: PROOF OF COMPACTION NEEDED. INSTALL UFER GROUND.
LATH/BRICK/ WATER BARRIER 09/15/2023 CANCELLED BY INSPECTOR FWILLIS
PLUMBING 1ST ROUGH UNDERGROUND 09/01/2023 APPROVED - AS NOTED MGIBSON
Note: NEED TO MOVE W/M VENT AWAY FROM PARELLEL FOOTER AND NEED TO REMOVE SANITARY TEE FROM SLAB, ALSO NEED TO REMOVE CARDBOARD FROM SHOWER AREA

Review History

Department Status Date In Date Out
BLD COMPLETE 12/12/2023 12/15/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BADMIN INFORMATION 11/20/2023 11/20/2023
Note: Marked INFORMATION By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM Wrong File Name Uploaded file name was not correct - Example: Site plan=site plan (do not add anything to the file names like numbers.)
BLD COMPLETE 07/27/2023 07/27/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
ELEC COMPLETE 07/21/2023 07/24/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 07/21/2023 07/25/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plan Sheet 40F5 is a new plan sheet not previously provided. Plan sheet includes contains structural design information and therefore must be signed and sealed by the Florida licensed professional engineer of record. Do not eliminate this plan sheet it. These details are required and so must be signed and sealed. FBC 107.1, Chapter 16. 2. Plan Sheet 30F5 is a new plan sheet not previously provided. Plan sheet contains structural design information and therefore must be signed and sealed by the Florida licensed professional engineer of record. Do not eliminate this plan sheet it. These details are required and so must be signed and sealed. FBC 107.1, Chapter 16. 2nd REQUEST
ZON COMPLETE 07/18/2023 07/18/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON HOLD 07/14/2023 07/14/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please fill out a single family dwelling affidavit. It will need to be signed by all owners and notarized. Once electronic copy is reviewed we will ask for the original to be dropped off for recording.
ZON HOLD 07/13/2023 07/13/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comment: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Job Description is unclear of exactly what you are proposing Dimensions on site plan do not match dimensions on plans. Please provide an elevation page. Plans must state that the addition exterior materials and colors will match existing.
MECH COMPLETE 07/13/2023 07/14/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC HOLD 07/13/2023 07/14/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. List all subcontractors 2. Need show if it is a long service or back to back service. If a long service it needs to comply with NEC 2017 230.70 3. Ned correct outlet spacing in master bedroom. switch wall. NEC 2017 210.52
BLD HOLD 07/13/2023 07/20/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building and Florida Building Code-Residential New Comment: Now that you have disclosed that the addition contains a bedroom / sleeping room provide the following: 1. Add note to electrical floor plan indicating new smoke alarms in addition shall be interconnected to all existing smoke alarms in the existing home and that existing areas of home are subject to inspection at time of final inspection to ensure smoke alarms are properly interconnected. Sections R314.3, R314.4. 2. Add note to electrical floor plan indicating carbon monoxide alarms shall be provided outside but within 10 feet of all existing bedrooms and existing areas of home are subject to inspection at time of final inspection to ensure carbon monoxide alarms have been provided at these locations. Sections R315.1.1, R315.1.3. New Comments: 1. Plan Sheet 40F5 is a new plan sheet not previously provided. Plan sheet includes contains structural design information and therefore must be signed and sealed by the Florida licensed professional engineer of record. Do not eliminate this plan sheet it. These details are required and so must be signed and sealed. FBC 107.1, Chapter 16. 2. Plan Sheet 30F5 is a new plan sheet not previously provided. Plan sheet contains structural design information and therefore must be signed and sealed by the Florida licensed professional engineer of record. Do not eliminate this plan sheet it. These details are required and so must be signed and sealed. FBC 107.1, Chapter 16.
PLUM COMPLETE 07/13/2023 07/20/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/13/2023 07/14/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 07/13/2023 07/18/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON HOLD 07/05/2023 07/05/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM repeat comment from Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Job Description is unclear of exactly what you are proposing Dimensions on site plan do not match dimensions on plans. Please provide an elevation page. Plans must state that the addition exterior materials and colors will match existing.
ELEC HOLD 07/05/2023 07/10/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to show what the room is and label it. 2. Room needs to comply with NEC 2017 210.52,210.70 210.8 3. List all subcontractors 2nd Request
MECH HOLD 07/05/2023 07/07/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Provide location of evaporator coil locations on floor plan or Energy Calcs
SW1 COMPLETE 07/05/2023 07/12/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
PLUM HOLD 07/05/2023 07/12/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM REPEAT COMMENT: Need floor plan to determine if Plumbing Review is required.
BLD HOLD 07/05/2023 07/11/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Repeat comment: 1. Provide complete truss package including truss layout / placement plan, truss cover sheet and profile sheets for each truss type. Plans to be signed and sealed by the truss manufacturer’s Florida licensed professional engineer. Truss plans to also include "approval" stamp by building engineer of record. You uploaded truss profile plan sheets under the Roofing Worksheet description. Remove and upload them with the truss layout plan and use the Truss Package description for all truss documents. Repeat comment: 2. Provide a completed Palm Coast Roofing Worksheet listing the roof covering and underlayment and their respective product approval numbers. Repeat comment: 3. Provide fully completed Palm Coat Product Approval worksheet. Include soffits and siding. Reeat comment: 4. Provide floor plan for addition drawn to sale. Identify room / rooms in the addition by name / type. Show all exterior doors and windows. Include sufficient area of adjacent existing home in floor plan to show what the adjacent room / rooms are and how access is provided to addition. If addition blocks any existing windows in existing home indicate how those windows will be re-located. (Plans uploaded not readable and need to be uploaded separately) Repeat comment: 5. Provide complete wall sections for each wall type including exterior walls and interior walls. Sections to include complete details from interior finishes through to exterior wall covering materials; include water resistive barrier; include interior furring, include vapor barrier; include insulation/ include exterior wall coverings, include interior wall coverings, include insulation. (Plans uploaded not readable and need to be uploaded separately)
BADMIN INFORMATION 06/27/2023 06/27/2023
Note: Marked INFORMATION By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM plans uploaded need to be individual uploaded not as a group. also structural plans need to be sealed plans
BLD HOLD 06/15/2023 06/23/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM 1. Provide complete truss package including truss layout / placement plan, truss cover sheet and profile sheets for each truss type. Plans to be signed and sealed by the truss manufacturer’s Florida licensed professional engineer. Truss plans to also include "approval" stamp by building engineer of record. You uploaded truss profile plan sheets under the Roofing Worksheet description. Remove and upload them with the truss layout plan and use the Truss Package description for all truss documents. 2. Provide a completed Palm Coast Roofing Worksheet listing the roof covering and underlayment and their respective product approval numbers. 3. Provide fully completed Palm Coat Product Approval worksheet. Include soffits and siding. 4. Provide floor plan for addition drawn to sale. Identify room / rooms in the addition by name / type. Show all exterior doors and windows. Include sufficient area of adjacent existing home in floor plan to show what the adjacent room / rooms are and how access is provided to addition. If addition blocks any existing windows in existing home indicate how those windows will be re-located. 5. Provide complete wall sections for each wall type including exterior walls and interior walls. Sections to include complete details from interior finishes through to exterior wall covering materials; include water resistive barrier; include interior furring, include vapor barrier; include insulation/ include exterior wall coverings, include interior wall coverings, include insulation. 6. Provide Completed City of Palm coast Roofing Worksheet
ELEC HOLD 06/15/2023 06/20/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to show what the room is and label it. 2. Room needs to comply with NEC 2017 210.52,210.70 210.8 3. List all subcontractors
GAS CANCEL 06/15/2023 06/20/2023
MECH HOLD 06/15/2023 06/20/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide floor plan and name room addition 2. Provide Energy Calculations
PLUM HOLD 06/15/2023 06/23/2023
Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Need floor plan to determine whether plumbing review is required.
SW1 HOLD 06/15/2023 06/21/2023
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO SHOW ONLY THE ADDITION ON THE SITE PLAN
ZON HOLD 06/15/2023 06/16/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Job Description is unclear of exactly what you are proposing Dimensions on site plan do not match dimensions on plans. Please provide an elevation page. Plans must state that the addition exterior materials and colors will match existing.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 02/16/2024
RECORDING FEE REIMBURSE DOC ¤10.00 07/27/2023
SURCHARGE FS 533.721 ¤2.00 07/27/2023
SURCHARGE - FS 468.631 ¤2.74 07/27/2023
SW ENG - INSPECTION 20 ¤20.00 07/27/2023
SW ENG - REVIEW 20 ¤20.00 07/27/2023
SITE PLAN 30 ¤30.00 07/27/2023
ADJUSTMENT 50% (¤182.68) 07/27/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/27/2023
INSPECTION - RESIDENTIAL ¤261.25 07/27/2023
PLAN REVIEW - RESIDENTIAL ¤74.10 07/27/2023
Fees Total Due: ¤0.00 Total Paid: ¤307.41