I want to search for...
Permit #2023060822
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7037-01350-0290 |
| CONDITIONED SPACE: 649 sqft |
| OPENED PORCH (WITH ROOF) : 44 sqft |
| OPENED PORCH (WITH ROOF) : 42 sqft |
| Total Square Footage: 735 sqft |
| Block: 01350 |
| Subdivision: 2176 - SECTION 37-LAKEVIEW |
| Job Phone: 386-547-2095 |
| Location Address: 51 LONDON DR |
| Type: BA - BUILDING ADDITION |
| Issue Date: 07/27/2023 |
| NOC: RECORDED |
| Applicant name: GEORGE FREDERICH BURTON III |
| Owner: KELSKE BRIAN J & CHRISTI L H&W |
|
Address 51 LONDON DRIVE PALM COAST, FL 32137 |
| Lot: 0290 |
| Contracted Stated Job Value: ¤94,450.00 |
| Job Description: ADDITION |
| Type: CN |
Contractor
GEORGE BURTON CONSTRUCTION, INC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1 SUNNY ROAD ORMOND BEACH, FL 32173 |
CGC1515993 (Exp: 08/31/2026) | 386-676-2837 | 386-672-2897 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 02/23/2024 | FINAL APPROVED | JSTEWART |
| Note: 2/20/2024 - PREVIOUS INSPECTION NOTES 1. Entry door requires a switched lightoutside door 2. Exteior outlets/GFCi are required to be the weather resisant type 3. Smoke detectors need to have back up battery installed 4. No hot water | |||
| U -UTILITY RESIDENTIAL FINAL | 02/23/2024 | FINAL APPROVED | DHANEY |
| Note: 2/20/2024 - PREVIOUS INSPECTION NOTES Drive not completed - Call back when completed . | |||
| BLD - BUILDING FINAL | 02/20/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Entry door requires a switched lightoutside door 2. Exteior outlets/GFCi are required to be the weather resisant type 3. Smoke detectors need to have back up battery installed 4. No hot water | |||
| U -UTILITY RESIDENTIAL FINAL | 02/20/2024 | CANCELLED BY APPLICANT | DHANEY |
| Note: Drive not completed - Call back when completed . | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/16/2024 | APPROVED | GBERTOLA |
| Note: 2/16/24=AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 2/9/2024 - PREVIOUS INSPECTION NOTES ** 02/09/24 Finished Floor Elevations (FFE): Site Plan must include the FFE of the subject property as well as the FFE of any adjacent developed properties. (A) Land Development Code Technical Manual, Section 300.01 (A)(1)(B)(3) ** Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A)Land Development Code Technical Manual, Section 300.01 (A)(1)(B)(4) ** Elevations on all adjacent property lines at 20-foot intervals. (B)Land Development Code Technical Manual, Section 300.01 (A)(1)(B)(5) ** | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/16/2024 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. | |||
| ROW - FINAL INSPECTION | 02/16/2024 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. HOMEOWNER WILL INSTALL PAVERS AROUND THE HOUSE | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/09/2024 | Disapproved - NO FEE | EMADISON |
| Note: ** 02/09/24 Finished Floor Elevations (FFE): Site Plan must include the FFE of the subject property as well as the FFE of any adjacent developed properties. (A) Land Development Code Technical Manual, Section 300.01 (A)(1)(B)(3) ** Elevations on all adjacent properties at a minimum of 20-foot intervals, on a 10 foot offset, outside the property lines. (A)Land Development Code Technical Manual, Section 300.01 (A)(1)(B)(4) ** Elevations on all adjacent property lines at 20-foot intervals. (B)Land Development Code Technical Manual, Section 300.01 (A)(1)(B)(5) ** | |||
| LATH/BRICK/ WATER BARRIER | 12/22/2023 | APPROVED | FWILLIS |
| INSULATION | 12/13/2023 | APPROVED | FWILLIS |
| Note: Inspector Notes from Inspection 2420 1. Exterior door have not been installed 2. Must submit exterior siding to building dept. and be approved before next inspection Check on next inspection | |||
| ALL ROUGH | 12/04/2023 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. Exterior door have not been installed 2. Must submit exterior siding to building dept. and be approved before next inspection Check on next inspection | |||
| ROOF VALLEY & METAL | 11/16/2023 | APPROVED | FWILLIS |
| WALL SHEATHING | 11/13/2023 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/13/2023 | APPROVED | JSTEWART |
| DOWN CELL | 11/08/2023 | APPROVED | FWILLIS |
| TIE BEAM / LINTEL | 10/26/2023 | APPROVED | FWILLIS |
| Note: 10/24/2023 - PREVIOUS INSPECTION NOTES 10/24/23: Marked on Plans * Pin into existing house is not epoxied as required & previously identified on 10/20/23. * Down rod is not tied to dowel as required. (corner of entry where new dowel was installed). 10/20/2023 - PREVIOUS INSPECTION NOTES 10/20/23- Multiple footing dowels need relocated for min 3/4' emedment. R606.13.4 CLEARANCE FROM MASONRY Multiple reinforcement tie ins to existing masonry need to be epoxied and secured (marked on walls). | |||
| TIE BEAM / LINTEL | 10/24/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 10/24/23: Marked on Plans * Pin into existing house is not epoxied as required & previously identified on 10/20/23. * Down rod is not tied to dowel as required. (corner of entry where new dowel was installed). 10/20/2023 - PREVIOUS INSPECTION NOTES 10/20/23- Multiple footing dowels need relocated for min 3/4' emedment. R606.13.4 CLEARANCE FROM MASONRY Multiple reinforcement tie ins to existing masonry need to be epoxied and secured (marked on walls). | |||
| TIE BEAM / LINTEL | 10/20/2023 | Disapproved - NO FEE | JSTEWART |
| Note: 10/20/23- Multiple footing dowels need relocated for min 3/4' emedment. R606.13.4 CLEARANCE FROM MASONRY Multiple reinforcement tie ins to existing masonry need to be epoxied and secured (marked on walls). | |||
| MONOLITHIC SLAB | 09/28/2023 | APPROVED | FWILLIS |
| Note: 9/26/2023 - PREVIOUS INSPECTION NOTES 9/26/23- Do to weather........Please clean out large cave in under barrier covering Footing reinforcement. R404.1.2.3.7.4 9/15/2023 - PREVIOUS INSPECTION NOTES PROOF OF COMPACTION NEEDED. INSTALL UFER GROUND. | |||
| MONOLITHIC SLAB | 09/26/2023 | Disapproved - NO FEE | JSTEWART |
| Note: 9/26/23- Do to weather........Please clean out large cave in under barrier covering Footing reinforcement. R404.1.2.3.7.4 9/15/2023 - PREVIOUS INSPECTION NOTES PROOF OF COMPACTION NEEDED. INSTALL UFER GROUND. | |||
| MONOLITHIC SLAB | 09/15/2023 | Disapproved - NO FEE | FWILLIS |
| Note: PROOF OF COMPACTION NEEDED. INSTALL UFER GROUND. | |||
| LATH/BRICK/ WATER BARRIER | 09/15/2023 | CANCELLED BY INSPECTOR | FWILLIS |
| PLUMBING 1ST ROUGH UNDERGROUND | 09/01/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: NEED TO MOVE W/M VENT AWAY FROM PARELLEL FOOTER AND NEED TO REMOVE SANITARY TEE FROM SLAB, ALSO NEED TO REMOVE CARDBOARD FROM SHOWER AREA |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/12/2023 | 12/15/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 11/20/2023 | 11/20/2023 |
| Note: Marked INFORMATION By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM Wrong File Name Uploaded file name was not correct - Example: Site plan=site plan (do not add anything to the file names like numbers.) | |||
| BLD | COMPLETE | 07/27/2023 | 07/27/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/21/2023 | 07/24/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 07/21/2023 | 07/25/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Plan Sheet 40F5 is a new plan sheet not previously provided. Plan sheet includes contains structural design information and therefore must be signed and sealed by the Florida licensed professional engineer of record. Do not eliminate this plan sheet it. These details are required and so must be signed and sealed. FBC 107.1, Chapter 16. 2. Plan Sheet 30F5 is a new plan sheet not previously provided. Plan sheet contains structural design information and therefore must be signed and sealed by the Florida licensed professional engineer of record. Do not eliminate this plan sheet it. These details are required and so must be signed and sealed. FBC 107.1, Chapter 16. 2nd REQUEST | |||
| ZON | COMPLETE | 07/18/2023 | 07/18/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | HOLD | 07/14/2023 | 07/14/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please fill out a single family dwelling affidavit. It will need to be signed by all owners and notarized. Once electronic copy is reviewed we will ask for the original to be dropped off for recording. | |||
| ZON | HOLD | 07/13/2023 | 07/13/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comment: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Job Description is unclear of exactly what you are proposing Dimensions on site plan do not match dimensions on plans. Please provide an elevation page. Plans must state that the addition exterior materials and colors will match existing. | |||
| MECH | COMPLETE | 07/13/2023 | 07/14/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 07/13/2023 | 07/14/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. List all subcontractors 2. Need show if it is a long service or back to back service. If a long service it needs to comply with NEC 2017 230.70 3. Ned correct outlet spacing in master bedroom. switch wall. NEC 2017 210.52 | |||
| BLD | HOLD | 07/13/2023 | 07/20/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All comments below per the 2020 Florida Building Code-Building and Florida Building Code-Residential New Comment: Now that you have disclosed that the addition contains a bedroom / sleeping room provide the following: 1. Add note to electrical floor plan indicating new smoke alarms in addition shall be interconnected to all existing smoke alarms in the existing home and that existing areas of home are subject to inspection at time of final inspection to ensure smoke alarms are properly interconnected. Sections R314.3, R314.4. 2. Add note to electrical floor plan indicating carbon monoxide alarms shall be provided outside but within 10 feet of all existing bedrooms and existing areas of home are subject to inspection at time of final inspection to ensure carbon monoxide alarms have been provided at these locations. Sections R315.1.1, R315.1.3. New Comments: 1. Plan Sheet 40F5 is a new plan sheet not previously provided. Plan sheet includes contains structural design information and therefore must be signed and sealed by the Florida licensed professional engineer of record. Do not eliminate this plan sheet it. These details are required and so must be signed and sealed. FBC 107.1, Chapter 16. 2. Plan Sheet 30F5 is a new plan sheet not previously provided. Plan sheet contains structural design information and therefore must be signed and sealed by the Florida licensed professional engineer of record. Do not eliminate this plan sheet it. These details are required and so must be signed and sealed. FBC 107.1, Chapter 16. | |||
| PLUM | COMPLETE | 07/13/2023 | 07/20/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/13/2023 | 07/14/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/13/2023 | 07/18/2023 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | HOLD | 07/05/2023 | 07/05/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM repeat comment from Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Job Description is unclear of exactly what you are proposing Dimensions on site plan do not match dimensions on plans. Please provide an elevation page. Plans must state that the addition exterior materials and colors will match existing. | |||
| ELEC | HOLD | 07/05/2023 | 07/10/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to show what the room is and label it. 2. Room needs to comply with NEC 2017 210.52,210.70 210.8 3. List all subcontractors 2nd Request | |||
| MECH | HOLD | 07/05/2023 | 07/07/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition 2. Provide location of evaporator coil locations on floor plan or Energy Calcs | |||
| SW1 | COMPLETE | 07/05/2023 | 07/12/2023 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 07/05/2023 | 07/12/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM REPEAT COMMENT: Need floor plan to determine if Plumbing Review is required. | |||
| BLD | HOLD | 07/05/2023 | 07/11/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Repeat comment: 1. Provide complete truss package including truss layout / placement plan, truss cover sheet and profile sheets for each truss type. Plans to be signed and sealed by the truss manufacturer’s Florida licensed professional engineer. Truss plans to also include "approval" stamp by building engineer of record. You uploaded truss profile plan sheets under the Roofing Worksheet description. Remove and upload them with the truss layout plan and use the Truss Package description for all truss documents. Repeat comment: 2. Provide a completed Palm Coast Roofing Worksheet listing the roof covering and underlayment and their respective product approval numbers. Repeat comment: 3. Provide fully completed Palm Coat Product Approval worksheet. Include soffits and siding. Reeat comment: 4. Provide floor plan for addition drawn to sale. Identify room / rooms in the addition by name / type. Show all exterior doors and windows. Include sufficient area of adjacent existing home in floor plan to show what the adjacent room / rooms are and how access is provided to addition. If addition blocks any existing windows in existing home indicate how those windows will be re-located. (Plans uploaded not readable and need to be uploaded separately) Repeat comment: 5. Provide complete wall sections for each wall type including exterior walls and interior walls. Sections to include complete details from interior finishes through to exterior wall covering materials; include water resistive barrier; include interior furring, include vapor barrier; include insulation/ include exterior wall coverings, include interior wall coverings, include insulation. (Plans uploaded not readable and need to be uploaded separately) | |||
| BADMIN | INFORMATION | 06/27/2023 | 06/27/2023 |
| Note: Marked INFORMATION By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM plans uploaded need to be individual uploaded not as a group. also structural plans need to be sealed plans | |||
| BLD | HOLD | 06/15/2023 | 06/23/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM 1. Provide complete truss package including truss layout / placement plan, truss cover sheet and profile sheets for each truss type. Plans to be signed and sealed by the truss manufacturer’s Florida licensed professional engineer. Truss plans to also include "approval" stamp by building engineer of record. You uploaded truss profile plan sheets under the Roofing Worksheet description. Remove and upload them with the truss layout plan and use the Truss Package description for all truss documents. 2. Provide a completed Palm Coast Roofing Worksheet listing the roof covering and underlayment and their respective product approval numbers. 3. Provide fully completed Palm Coat Product Approval worksheet. Include soffits and siding. 4. Provide floor plan for addition drawn to sale. Identify room / rooms in the addition by name / type. Show all exterior doors and windows. Include sufficient area of adjacent existing home in floor plan to show what the adjacent room / rooms are and how access is provided to addition. If addition blocks any existing windows in existing home indicate how those windows will be re-located. 5. Provide complete wall sections for each wall type including exterior walls and interior walls. Sections to include complete details from interior finishes through to exterior wall covering materials; include water resistive barrier; include interior furring, include vapor barrier; include insulation/ include exterior wall coverings, include interior wall coverings, include insulation. 6. Provide Completed City of Palm coast Roofing Worksheet | |||
| ELEC | HOLD | 06/15/2023 | 06/20/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to show what the room is and label it. 2. Room needs to comply with NEC 2017 210.52,210.70 210.8 3. List all subcontractors | |||
| GAS | CANCEL | 06/15/2023 | 06/20/2023 |
| MECH | HOLD | 06/15/2023 | 06/20/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide floor plan and name room addition 2. Provide Energy Calculations | |||
| PLUM | HOLD | 06/15/2023 | 06/23/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Need floor plan to determine whether plumbing review is required. | |||
| SW1 | HOLD | 06/15/2023 | 06/21/2023 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM NEED TO SHOW ONLY THE ADDITION ON THE SITE PLAN | |||
| ZON | HOLD | 06/15/2023 | 06/16/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Job Description is unclear of exactly what you are proposing Dimensions on site plan do not match dimensions on plans. Please provide an elevation page. Plans must state that the addition exterior materials and colors will match existing. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/16/2024 |
| RECORDING FEE REIMBURSE DOC | ¤10.00 | 07/27/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 07/27/2023 |
| SURCHARGE - FS 468.631 | ¤2.74 | 07/27/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 07/27/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/27/2023 |
| SITE PLAN 30 | ¤30.00 | 07/27/2023 |
| ADJUSTMENT 50% | (¤182.68) | 07/27/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/27/2023 |
| INSPECTION - RESIDENTIAL | ¤261.25 | 07/27/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤74.10 | 07/27/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤307.41 |