I want to search for...
Permit #2023060823
Permit Details
Status: COED
| Parcel Id: 28-10-30-5415-00000-1040 |
| CONDITIONED SPACE: 1986 sqft |
| GARAGE: 443 sqft |
| OPENED PORCH (WITH ROOF) : 78 sqft |
| SCREEN PORCH (SOLID ROOF) : 221 sqft |
| Total Square Footage: 2728 sqft |
| Subdivision: 2310 - SAWMILL BRANCH 2A |
| Job Phone: 904-219-3385 |
| Location Address: 8 SAWMILL CT |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/13/2023 |
| NOC: RECORDED |
| Applicant name: RAYMOND CLIVE CROSBY |
| Owner: DR HORTON INC |
|
Address 4220 RACE TRACK RD ST JOHNS , FL 32259 |
| Lot: 104 |
| Contracted Stated Job Value: ¤198,600.00 |
| Job Description: SINGLE FAMILY |
| Type: CN |
Contractor
DR HORTON, INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
4220 RACE TRACK RD SAINT JOHNS, FL 32259 |
CBC058997 (Exp: 08/31/2026) | 904-268-2845 | 904-899-5992 |
Sub Contractors
PAUL ERIC FORSTER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6114 GOODMAN RD JACKSONVILLE, FL 32244 |
CFC1429261 (Exp: 08/31/2026) | 904-647-1820 |
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
JAMES M GREENSLADE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
311 S BAY ST BUNNELL, FL 32110 |
EC13006083 (Exp: 08/31/2026) | 386-263-2960 | 386-263-2980 |
EDWARD DOUGLAS TENNANT
| Status | Location Address | State License Number | Phone | Fax |
| INACTIVE |
3370 AGRICULTURAL CENTER DRIVE ST. AUGUSTINE , FL 32092 |
CAC1813372 (Exp: 08/31/2026) | (904)829-8898 | (904)829-6587 |
Inspection History
| Type | Request Date | Result | Inspector |
| U -UTILITY RESIDENTIAL FINAL | 12/15/2023 | APPROVED - AS NOTED | LFITZGERALD |
| Note: clean out broken down at fitting-some soils washed into line-required water to be flushed/ran from house to ensure no clog-water flowed as normal-lummer installed new riserpipe with cap 12/13/2023 - PREVIOUS INSPECTION NOTES 12/11/2023 - PREVIOUS INSPECTION NOTES Sewer clean out cap/lid missing - needs installed 12/13 . | |||
| U -UTILITY RESIDENTIAL FINAL | 12/13/2023 | Disapproved - NO FEE | DHANEY |
| Note: 12/11/2023 - PREVIOUS INSPECTION NOTES Sewer clean out cap/lid missing - needs installed 12/13 . | |||
| ROW - STORMWATER FINAL | 12/13/2023 | APPROVED | EMADISON |
| Note: | |||
| U -UTILITY RESIDENTIAL FINAL | 12/11/2023 | CANCELLED BY APPLICANT | DHANEY |
| ROW - FINAL APRON (AFTER POUR) | 12/11/2023 | APPROVED | GBERTOLA |
| Note: AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 12/11/2023 | Disapproved - NO FEE | GBERTOLA |
| Note: 12/12/23= DRAINAGE CONVEYANCE ON THE RIGHT SIDE IS NOT CONSISTENT, Section 300.01 (A)(1)(C)(6). DESIGN A SWALE AT THE BACK OF THE PROPERTY TO DIVERT WATER AWAY FROM THE HOUSE. | |||
| BLD - BUILDING FINAL | 12/11/2023 | FINAL APPROVED | JSTEWART |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/21/2023 | APPROVED | EMADISON |
| Note: | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 11/21/2023 | APPROVED | EMADISON |
| U-CROSS CONNECTION | 11/20/2023 | APPROVED | DHANEY |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 11/16/2023 | Disapproved - NO FEE | EMADISON |
| Note: ** 11/16/23 FINAL SURVEY SHOWS WATER WILL FLOW BACK TOWARDS STRUCTURE ** Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. (D)Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’.(E) | |||
| ELECTRIC - EARLY POWER | 10/25/2023 | APPROVED | RSIMS |
| Note: 10/20/2023 - PREVIOUS INSPECTION NOTES 10/20/23: 1). Outlet boxes at kitchen counters are covered with tile so visual confirmation of being safed off cannot be done. 2). Garbage disposal switch is missing the cover. Inspector Notes from Inspection 2200 Release to FPL at 10:24 AM 08/25/2023 | |||
| ROW- PRE-APRON (PRE-POUR) | 10/20/2023 | APPROVED | RGROSS |
| ELECTRIC - EARLY POWER | 10/20/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 10/20/23: 1). Outlet boxes at kitchen counters are covered with tile so visual confirmation of being safed off cannot be done. 2). Garbage disposal switch is missing the cover. Inspector Notes from Inspection 2200 Release to FPL at 10:24 AM 08/25/2023 | |||
| GRAVITY SEWER TEST | 09/11/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| U - SEWER TIE IN | 09/11/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| INSULATION | 09/07/2023 | APPROVED | FWILLIS |
| LATH/BRICK/ WATER BARRIER | 08/29/2023 | APPROVED | TSTAUFFACHER |
| ALL ROUGH | 08/29/2023 | APPROVED | TSTAUFFACHER |
| ELECTRIC-TUG | 08/25/2023 | APPROVED - AS NOTED | TSTAUFFACHER |
| Note: Release to FPL at 10:24 AM 08/25/2023 | |||
| ROOF VALLEY & METAL | 08/10/2023 | APPROVED | RSIMS |
| Note: Inspector Notes from Inspection 2460 1. Stud pack missing 2 anchor (screws) Right side front entry, marked on print. 2. Cant see front or back porch beam notch, marked on print. Check on next inspection | |||
| WALL SHEATHING | 08/07/2023 | APPROVED | MKRASKI |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/07/2023 | APPROVED - AS NOTED | MKRASKI |
| Note: 1. Stud pack missing 2 anchor (screws) Right side front entry, marked on print. 2. Cant see front or back porch beam notch, marked on print. Check on next inspection | |||
| SHEARWALL | 08/02/2023 | APPROVED | FWILLIS |
| Note: Inspector Notes from Inspection 2250 7/20/23- Please instal permit box into ground for address, and document protection. | |||
| FOUND SURVEY APPROVED (OFFICE) | 08/01/2023 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 07/20/2023 | APPROVED - AS NOTED | JSTEWART |
| Note: 7/20/23- Please instal permit box into ground for address, and document protection. | |||
| WATER METER INSTALLATION REQUEST | 07/17/2023 | APPROVED | CSTONE |
| PLUMBING 1ST ROUGH UNDERGROUND | 07/17/2023 | APPROVED | MGIBSON |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 08/01/2023 | 08/01/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/01/2023 | 08/01/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/11/2023 | 07/11/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | HOLD | 07/10/2023 | 07/10/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Repeat comments: Bedrooms are labeled incorrectly on floor plan Horizontal 10" trim band must wrap corners at least two feet On color sheet one of the accent color boxes must be checked | |||
| MECH | COMPLETE | 07/10/2023 | 07/11/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/10/2023 | 07/11/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| URB | COMPLETE | 06/20/2023 | 07/07/2023 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 06/15/2023 | 06/16/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 06/15/2023 | 06/16/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 06/15/2023 | 06/20/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to reference the 2017 NEC in the riser diagram | |||
| ENGIN1 | COMPLETE | 06/15/2023 | 06/16/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/15/2023 | 06/20/2023 |
| LOCATE | COMPLETE | 06/15/2023 | 06/20/2023 |
| Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM | |||
| MECH | HOLD | 06/15/2023 | 06/20/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show R11 insulation in walls. Energy Calcs say R13. Revise to match. 2. Direction house faces on Heatload does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2020 7Th Edition | |||
| SW1 | COMPLETE | 06/15/2023 | 06/22/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/15/2023 | 06/20/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Bedrooms are labeled incorrectly on floor plan Horizontal 10" trim band must wrap corners at least two feet On color sheet one of the accent color boxes must be checked | |||
| BADMIN | COMPLETE | 06/15/2023 | 06/20/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/14/2023 |
| CONNECTION FEES | ¤25.00 | 07/13/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 07/13/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 07/13/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 07/13/2023 |
| IMPACT FEE FIRE | ¤420.52 | 07/13/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/13/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/13/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 07/13/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 07/13/2023 |
| IMPACT FEE TRANSPORTATION | ¤3,311.00 | 07/13/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/13/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 07/13/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 07/13/2023 |
| SURCHARGE FS 533.721 | ¤4.58 | 07/13/2023 |
| SURCHARGE - FS 468.631 | ¤6.87 | 07/13/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/13/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/13/2023 |
| SW ENG PRE APRON | ¤30.00 | 07/13/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/13/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/13/2023 |
| TRANS IMPACT FEE ADMIN | ¤99.33 | 07/13/2023 |
| TRANS IMPACT FEE ADMIN | (¤99.33) | 07/13/2023 |
| SEWER INSPECTION | ¤25.00 | 07/13/2023 |
| SEWER CAPITAL FACILITY | ¤2,803.23 | 07/13/2023 |
| WATER CAPITAL FACILITY FEE | ¤2,605.24 | 07/13/2023 |
| SITE PLAN 30 | ¤30.00 | 07/13/2023 |
| WATER-METER | ¤505.39 | 07/13/2023 |
| WATER-METER | ¤419.86 | 07/13/2023 |
| ADJUSTMENT 50% | (¤458.02) | 07/13/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/13/2023 |
| INSPECTION - RESIDENTIAL | ¤690.25 | 07/13/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤195.78 | 07/13/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤18,796.85 |