I want to search for...

Permit #2023060982

Permit Details

Status: COED

Parcel Id: 07-11-31-7015-00010-0270
CONDITIONED SPACE: 2804 sqft
OPENED PORCH (WITH ROOF) : 52 sqft
SCREEN PORCH (SOLID ROOF) : 396 sqft
GARAGE: 741 sqft
Total Square Footage: 3993 sqft
Block: 00010
Subdivision: 2194 - SECTION 15-COUNTRY CLUB COVE
Job Phone: 386-445-2012
Location Address: 59 COCHISE CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/02/2023
NOC: RECORDED
Applicant name: JOHN NICHOLAS CORDASCI
Owner: DAVID O GARGANO AND CHI D GARGANO

Address

275 EVERGREEN AVENUE

HAMDEN, CT 06518

Lot: 0270
Contracted Stated Job Value: ¤614,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

SKYWAY BUILDERS INC
Status Location Address State License Number Phone
INACTIVE

PO BOX 354786

PALM COAST, FL 32135

CBC1263769 (Exp: 08/31/2024) 386-445-2012

Sub Contractors

HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
MARK JOHN LUTCZA
Status Location Address State License Number Phone
ACTIVE

26 ROYAL LEAF LANE

PALM COAST, FL 32164

EC13005145 (Exp: 08/31/2026) 386-586-0770
RICHARD GARY WILSON JR
Status Location Address Mailing Address State License Number Phone
ACTIVE

1504 OLD MOODY BLVD

BUNNELL, FL 32110

UNIT 6

BUNNELL, FL 32110

CAC1817645 (Exp: 08/31/2026) 386-586-6290
DANIEL DAVID RUTKOWSKI III
Status Location Address State License Number Phone Fax
ACTIVE

1687 STATE AVENUE

HOLLY HILL, FL 32117

CCC1328639 (Exp: 08/31/2026) 386-290-7490 386-256-0001

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 06/26/2024 FINAL APPROVED JSTEWART
U -UTILITY RESIDENTIAL FINAL 06/18/2024 FINAL APPROVED BWRIGHT
Note: 6/17/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LFITZGERALD 6/17/2024 10:36:06 AM *** unable to locate sewer C/O at the tap
ROW - STORMWATER FINAL 06/17/2024 APPROVED EMADISON
U -UTILITY RESIDENTIAL FINAL 06/17/2024 Disapproved -FEE REQUIRED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 6/17/2024 10:36:06 AM *** unable to locate sewer C/O at the tap
U-CROSS CONNECTION 06/17/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 6/17/2024 10:35:26 AM *** irrigatin meter-no cross connection
ROW - FINAL APRON (AFTER POUR) 06/17/2024 APPROVED EMADISON
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/04/2024 APPROVED EMADISON
Note:
ROW FIELD SURVEY /GRADING CERTIFICATION 06/04/2024 APPROVED EMADISON
ROW- PRE-APRON (PRE-POUR) 05/03/2024 APPROVED - AS NOTED EMADISON
Note: *** NOTES ADDED BY EMADISON 5/3/2024 10:40:57 AM *** ** 05/03/24 READY TO SET PAVERS ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved. 5/2/2024 - PREVIOUS INSPECTION NOTES ** 05/02/24 AS NOTED IN PREVIOUS INSPECTION DATED 04/05/24 ** BUILDER NEEDS TO SCHEDULE THE NEXT PRE-POUR INSPECTION AFTER YOU HAVE SPREAD AND COMPACTED THE PAVER BASE MATERIAL ** ***DO NOT SET ANY PAVERS*** UNTIL AFTER THE INSPECTION FOR COMPACTION OF PAVER BASE MATERIAL HAS BEEN APPROVED ** SEE ATTACHED PHOTOS FROM TODAYS INSPECTION ______________________________________________________________________________________________________________________ New inspection due to canceled inspection New inspection due to canceled inspection Inspector Notes from Inspection 9271 ** 04/26/24 PAVER RESTRAINT INSPECTION WAS PREVIOUSLY PASSED 0N 04/05/24 ** THE NEXT DRIVEWAY PRE-POUR INSPECTION REQUIRED IS AFTER YOU HAVE SPREAD AND COMPACTED THE PAVER BASE MATERIAL. ******** DO NOT SET ANY PAVERS UNTIL THE NEXR PRE-POUR INSPECTION HAS BEEN APPROVED********
ROW- PRE-APRON (PRE-POUR) 05/02/2024 Disapproved -FEE REQUIRED EMADISON
Note: ** 05/02/24 AS NOTED IN PREVIOUS INSPECTION DATED 04/05/24 ** BUILDER NEEDS TO SCHEDULE THE NEXT PRE-POUR INSPECTION AFTER YOU HAVE SPREAD AND COMPACTED THE PAVER BASE MATERIAL ** ***DO NOT SET ANY PAVERS*** UNTIL AFTER THE INSPECTION FOR COMPACTION OF PAVER BASE MATERIAL HAS BEEN APPROVED ** SEE ATTACHED PHOTOS FROM TODAYS INSPECTION ______________________________________________________________________________________________________________________ New inspection due to canceled inspection New inspection due to canceled inspection Inspector Notes from Inspection 9271 ** 04/26/24 PAVER RESTRAINT INSPECTION WAS PREVIOUSLY PASSED 0N 04/05/24 ** THE NEXT DRIVEWAY PRE-POUR INSPECTION REQUIRED IS AFTER YOU HAVE SPREAD AND COMPACTED THE PAVER BASE MATERIAL. ******** DO NOT SET ANY PAVERS UNTIL THE NEXR PRE-POUR INSPECTION HAS BEEN APPROVED********
ROW- PRE-APRON (PRE-POUR) 05/01/2024 CANCELLED BY APPLICANT WEB
Note: New inspection due to canceled inspection Inspector Notes from Inspection 9271 ** 04/26/24 PAVER RESTRAINT INSPECTION WAS PREVIOUSLY PASSED 0N 04/05/24 ** THE NEXT DRIVEWAY PRE-POUR INSPECTION REQUIRED IS AFTER YOU HAVE SPREAD AND COMPACTED THE PAVER BASE MATERIAL. ******** DO NOT SET ANY PAVERS UNTIL THE NEXR PRE-POUR INSPECTION HAS BEEN APPROVED********
ROW- PRE-APRON (PRE-POUR) 04/30/2024 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 9271 ** 04/26/24 PAVER RESTRAINT INSPECTION WAS PREVIOUSLY PASSED 0N 04/05/24 ** THE NEXT DRIVEWAY PRE-POUR INSPECTION REQUIRED IS AFTER YOU HAVE SPREAD AND COMPACTED THE PAVER BASE MATERIAL. ******** DO NOT SET ANY PAVERS UNTIL THE NEXR PRE-POUR INSPECTION HAS BEEN APPROVED********
ROW- PAVER RESTRAINTS 04/26/2024 APPROVED - AS NOTED EMADISON
Note: ** 04/26/24 PAVER RESTRAINT INSPECTION WAS PREVIOUSLY PASSED 0N 04/05/24 ** THE NEXT DRIVEWAY PRE-POUR INSPECTION REQUIRED IS AFTER YOU HAVE SPREAD AND COMPACTED THE PAVER BASE MATERIAL. ******** DO NOT SET ANY PAVERS UNTIL THE NEXR PRE-POUR INSPECTION HAS BEEN APPROVED********
ROW- PRE-APRON (PRE-POUR) 04/05/2024 PARTIALLY APPROVED PFLANAGAN
Note: READY TO POUR APRON AND PAVER RESTRAINTS ONLY. ALL BASE NEEDS TO SPREAD AND COMPACTED BEFORE NEXT PREPOUR WILL BE SCHEDULED AND PASSED **** DO NOT LAY ANY PAVERS AT THIS TIME**** AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS
ROW- PAVER RESTRAINTS 04/05/2024 APPROVED PFLANAGAN
Note: PAVER RESTRAINTS GOOD AT THIS TIME
ELECTRIC - EARLY POWER 02/21/2024 APPROVED AGAETANO
INSULATION 12/27/2023 APPROVED AGAETANO
INSULATION 12/22/2023 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 12/18/2023 APPROVED AGAETANO
ALL ROUGH 12/18/2023 APPROVED - AS NOTED AGAETANO
Note: 11/27/2023 - PREVIOUS INSPECTION NOTES 12-18-2023 1. Energy calcs do not match windows installed. Please revise and submit to the building department. 2. Nail plate needed at dryer vent. Check at insulation.
WINDOW NAILING 11/27/2023 APPROVED AGAETANO
Note: 11-27-2023 SGD frame approved only.
ALL ROUGH 11/27/2023 CANCELLED BY APPLICANT AGAETANO
GRAVITY SEWER TEST 11/03/2023 APPROVED RSIMS
U - SEWER TIE IN 11/03/2023 APPROVED RSIMS
WALL SHEATHING 10/02/2023 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/02/2023 APPROVED - AS NOTED AGAETANO
Note: 10-02-2023 Floor plan, 2 x 12 header does not have HTT4 and studs installed. Please install per plan. LVL not sufficient fasteners. Check at next inspection.
ROOF VALLEY & METAL 10/02/2023 APPROVED AGAETANO
ELECTRIC TEMP POLE 09/20/2023 APPROVED AGAETANO
TIE BEAM / LINTEL 09/06/2023 APPROVED AGAETANO
FOUND SURVEY APPROVED (OFFICE) 08/29/2023 APPROVED TBAKER
MONOLITHIC SLAB 08/22/2023 APPROVED FWILLIS
Note: 8/21/2023 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection 8/17/2023 - PREVIOUS INSPECTION NOTES Slab work not started 08-21-2023 1. F1 footings not installed per plan. Check all F1 footings. 2. Garage bearing wall plumbing lines not per code. 3. AC line not installed as per plan. Cannot run paralell to bearing wall footing. 4. Refrigerator water lines not installed as per code. Releiving arch and or pipes need to be sleeved. 5. Multiple areas need to be tamped. Inspection stopped.
MONOLITHIC SLAB 08/21/2023 Disapproved - NO FEE AGAETANO
Note: New inspection due to canceled inspection 8/17/2023 - PREVIOUS INSPECTION NOTES Slab work not started 08-21-2023 1. F1 footings not installed per plan. Check all F1 footings. 2. Garage bearing wall plumbing lines not per code. 3. AC line not installed as per plan. Cannot run paralell to bearing wall footing. 4. Refrigerator water lines not installed as per code. Releiving arch and or pipes need to be sleeved. 5. Multiple areas need to be tamped. Inspection stopped.
ROW- PROJECT STATUS 08/21/2023 APPROVED PFLANAGAN
Note: WENT OUT TO LOOK AT ROAD DAMAGE BUILDER REQUEST. SEE PHOTOS ON INSPECTION 9200 DATED 8/21/23 FOR AREA THAT NEEDS REPAIRED AREA WAS PAINTED. THIS INSPECTION WAS DURING SLAB POUR. THE BUILDER WILL BE RESPONSIBILE FOR THE AREA OUT LINED IN PAINT. IF THERE IS ANY MORE AREAS AT AFTER POUR AREAS WILL NEED REPAIRED.
MONOLITHIC SLAB 08/18/2023 CANCELLED BY APPLICANT WEB
Note: 8/17/2023 - PREVIOUS INSPECTION NOTES Slab work not started
MONOLITHIC SLAB 08/17/2023 Disapproved -FEE REQUIRED TSTAUFFACHER
Note: Slab work not started
PLUMBING 1ST ROUGH UNDERGROUND 08/16/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 08/04/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 06/03/2024 06/07/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
MECH COMPLETE 06/03/2024 06/07/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 04/18/2024 04/22/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 COMPLETE 04/18/2024 04/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 04/18/2024 04/18/2024
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 04/18/2024 04/18/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/28/2023 08/29/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 08/28/2023 08/29/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
SW1 COMPLETE 07/27/2023 07/27/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON COMPLETE 07/20/2023 07/21/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/19/2023 07/19/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ELEC COMPLETE 07/19/2023 07/21/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON HOLD 07/19/2023 07/19/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please turn in original right of way agreement for recording
BLD COMPLETE 07/19/2023 07/21/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SW1 HOLD 07/19/2023 07/25/2023
Note: Held By: FRANK SLADISH - - FSLADISH@PALMCOASTGOV.COM Need to know if this structure is block or wood to determine if the FFE elevation will work. On the right side the proposed elevations go up and down, they are not consistent flowing frow rear to front.
BADMIN INFORMATION 06/29/2023 06/29/2023
Note: Marked INFORMATION By: MICHELLE RAMOS - - MRAMOS@PALMCOASTGOV.COM Unable to process NOC must include State of Florida, County of Flagler. It may be notarized out of state however document must state on top. State of Florida, County of Flagler.
SW1 HOLD 06/28/2023 06/28/2023
Note: Held By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM The tolerance along side lot lines is no more than 20 feet flat, with positive fall on each side. Positive fall is considered to be 0.10 feet in 20 feet. The minimum fall from the rear property line to the front is 0.50 feet. Refer to stormwater checklist to make the corrections needed to meet the city minimums stormwater requirements
BADMIN COMPLETE 06/22/2023 06/26/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON HOLD 06/20/2023 06/23/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide a right of way agreement for paver driveway. It must be signed by all owners on the deed and notarized. Once electronic copy is approved we will ask for the original copy to send for recording
BLD HOLD 06/20/2023 06/23/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
CUSVC COMPLETE 06/20/2023 06/21/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 06/20/2023 06/22/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need to reference the 2017 NEC 2. Need correct outlet spacing in M.bed and bed 3. NEC 2017 210.52 3. All outlets in laundry room need to be GFCI protected. NEC 2017 210.8
ENGIN1 COMPLETE 06/20/2023 06/20/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 06/20/2023 06/22/2023
LOCATE COMPLETE 06/20/2023 06/23/2023
Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 06/20/2023 06/22/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SWALE COMPLETE 06/20/2023 07/28/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 06/27/2024
REINSPECTION FEE ¤40.00 06/27/2024
SW ENG REINSPECTION 20 ¤20.00 06/27/2024
SW ENG REINSPECTION 30 ¤30.00 06/27/2024
PLAN REVIEW - REVISION ¤32.50 06/27/2024
REINSPECTION RESIDENTIAL ¤40.00 06/27/2024
CONNECTION FEES ¤1,166.26 08/02/2023
SW ENG - REVIEW 20 ¤20.00 08/02/2023
SW ENG RES REVIEW 200 ¤200.00 08/02/2023
TRANS IMPACT FEE ADMIN ¤54.36 08/02/2023
TRANS IMPACT FEE ADMIN (¤54.36) 08/02/2023
SEWER INSPECTION ¤25.00 08/02/2023
SEWER CAPITAL FACILITY ¤5,344.82 08/02/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 08/02/2023
SITE PLAN 30 ¤30.00 08/02/2023
SURCHARGE FS 533.721 ¤10.99 08/02/2023
SURCHARGE - FS 468.631 ¤16.48 08/02/2023
SW ENG - FOUNDATION SURVEY ¤20.00 08/02/2023
SW ENG INSPECTION 80 ¤80.00 08/02/2023
SW ENG PRE APRON ¤30.00 08/02/2023
WATER-METER ¤505.39 08/02/2023
WATER- TURN ON ¤25.00 08/02/2023
WATER- TURN ON ¤25.00 08/02/2023
ADJUSTMENT 50% (¤1,098.71) 08/02/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/02/2023
INSPECTION - RESIDENTIAL ¤1,688.50 08/02/2023
PLAN REVIEW - RESIDENTIAL ¤478.92 08/02/2023
FIRE IMPACT FEE ADMIN ¤12.62 08/02/2023
FIRE IMPACT FEE ADMIN (¤12.62) 08/02/2023
FC IMPACT FEE EMS ¤62.00 08/02/2023
IMPACT FEE FIRE ¤420.52 08/02/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 08/02/2023
FC IMPACT FEE LIBRARY ¤268.00 08/02/2023
IMPACT FEE PARKS ¤1,769.15 08/02/2023
IMPACT FEE SCHOOL ¤5,450.00 08/02/2023
RECORDING FEE REIMBURSE DOC ¤44.00 08/02/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 08/02/2023
WATER -IRRIGATION INSPECTION ¤25.00 08/02/2023
WATER -IRRIGATION INSPECTION ¤25.00 08/02/2023
PARKS IMPACT FEE ADMIN ¤53.07 08/02/2023
PARKS IMPACT FEE ADMIN (¤53.07) 08/02/2023
Fees Total Due: ¤0.00 Total Paid: ¤22,797.70