I want to search for...
Permit #2023061149
Permit Details
Status: FINAL
| Parcel Id: 20-12-31-2964-00000-1560 |
| Block: 00000 |
| Subdivision: 2307 - GRAND LANDINGS PHASE 4 |
| Job Phone: 386-212-2958 |
| Location Address: 105 NIGHTHAWK LN |
| Type: PO - POOL |
| Issue Date: 08/03/2023 |
| NOC: RECORDED |
| Applicant name: COBY KYLE MOORE |
| Owner: DE LIMA ALEX OLIVEIRA RODRIGUES & CARLA HENRIQUES |
|
Address 105 NIGHTHAWK LANE PALM COAST, FL 32164 |
| Lot: 1560 |
| Contracted Stated Job Value: ¤58,000.00 |
| Job Description: Swimming pool with deck- new fence by others |
| Type: CN |
Contractor
CM DESIGNS INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1050 ROBERTS STREET ORMOND BEACH, FL 32174 |
CPC1456991 (Exp: 08/31/2026) | (386)615-7425 | 386-676-2963 |
Sub Contractors
GREGORY ALAN WARD
| Status | Location Address | State License Number | Phone |
| INACTIVE |
P.O. BOX 731453 ORMOND BEACH, FL 32174 |
EC13005000 (Exp: 08/31/2026) | 386-566-7248 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 01/05/2024 | FINAL APPROVED | RSIMS |
| Note: 1/4/2024 - PREVIOUS INSPECTION NOTES 1/4/24: No answer at the door. 1). Remote alarm is plugged in at the exterior of the house. Must be installed on the House interior for Pool Final Inspection. Also, the magnet for resetting the alarms was not on site so I could not test the pool side alarm. | |||
| POOL FINAL | 01/04/2024 | Disapproved - NO FEE | RSIMS |
| Note: 1/4/24: No answer at the door. 1). Remote alarm is plugged in at the exterior of the house. Must be installed on the House interior for Pool Final Inspection. Also, the magnet for resetting the alarms was not on site so I could not test the pool side alarm. | |||
| U -UTILITY RESIDENTIAL FINAL | 01/04/2024 | FINAL APPROVED | JHARDING |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/27/2023 | APPROVED - AS NOTED | FSLADISH |
| Note: 12/27/23 SURVEY CORRECTIONS MADE PER INSPECTORS NOTES. APPROVING AS NOTED. 12/15/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. 2) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 3) Sec 300.02 B1 If the survey is incomplete, unclear, does not adequately show the drainage patterns | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/27/2023 | APPROVED - AS NOTED | FSLADISH |
| Note: 12/27/23 SPOKE TO THE HOMEOWNER CARLA WHO INDICATED NO ADVERSE DRAINAGE CONDITIONS FROM POOL BUILD, SHE SAID EVEN DURING THIS SEASON OF EXCESS RAIN THAT SHE HAS NOT HAD ANY DRAINAGE ISSUES. APPROVING AS NOTED. Inspector Notes from Inspection 9463 12/27/23 SURVEY CORRECTIONS MADE PER INSPECTORS NOTES. APPROVING AS NOTED. 12/15/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. 2) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 3) Sec 300.02 B1 If the survey is incomplete, unclear, does not adequately show the drainage patterns | |||
| ROW - FINAL INSPECTION | 12/27/2023 | APPROVED - AS NOTED | FSLADISH |
| Note: 12/27/23 SPOKE TO THE HOMEOWNER CARLA WHO INDICATED NO ADVERSE DRAINAGE CONDITIONS FROM POOL BUILD, SHE SAID EVEN DURING THIS SEASON OF EXCESS RAIN THAT SHE HAS NOT HAD ANY DRAINAGE ISSUES. APPROVING AS NOTED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. _______________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 12/27/23 SPOKE TO THE HOMEOWNER CARLA WHO INDICATED NO ADVERSE DRAINAGE CONDITIONS FROM POOL BUILD, SHE SAID EVEN DURING THIS SEASON OF EXCESS RAIN THAT SHE HAS NOT HAD ANY DRAINAGE ISSUES. APPROVING AS NOTED. Inspector Notes from Inspection 9463 12/27/23 SURVEY CORRECTIONS MADE PER INSPECTORS NOTES. APPROVING AS NOTED. 12/15/2023 - PREVIOUS INSPECTION NOTES 1) Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. 2) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 3) Sec 300.02 B1 If the survey is incomplete, unclear, does not adequately show the drainage patterns | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/15/2023 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. 2) Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. 3) Sec 300.02 B1 If the survey is incomplete, unclear, does not adequately show the drainage patterns | |||
| ELECTRIC AND ALARM | 12/05/2023 | APPROVED | RSIMS |
| POOL DECK | 10/10/2023 | APPROVED | RSIMS |
| STEEL AND GROUND | 09/25/2023 | APPROVED | RSIMS |
| STEEL AND GROUND | 09/22/2023 | CANCELLED BY APPLICANT | WEB |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/25/2023 | 07/27/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 07/25/2023 | 07/25/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please rename your files correctly. | |||
| ZON | COMPLETE | 07/14/2023 | 07/14/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | HOLD | 07/13/2023 | 07/17/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Provide detail or note on plans showing existing fence or screen enclosure complies with R4501.17.1.8. Show door swing and latch height. | |||
| ZON | HOLD | 07/13/2023 | 07/13/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM for the fence permit the homeowner must create a profile on our portal under homeowner and submit a fence acknowlegment so it creates a fence permit for this property. once this has been completed let me know and I will release the permit. Currently on hold until that is completed | |||
| SW1 | COMPLETE | 07/13/2023 | 07/18/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/22/2023 | 06/26/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Provide detail or note on plans showing existing fence or screen enclosure complies with R4501.17.1.8. Show door swing and latch height. | |||
| ELEC | COMPLETE | 06/22/2023 | 06/26/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/22/2023 | 06/23/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/22/2023 | 06/26/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/22/2023 | 06/26/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site Plan: Please provide Clear deck dimensions on the site plan. please make sure the placement of pool equiptment on site plan match the pool plan. Currently it does not match. Demoonstrate how the pool will be enclosed by the fence on site plan Fence or screen for pool: Permit for fence must be completed by the home owner. Pool must be fully enclosed by fence (height/material/color as allowed by City Land Development Code) or screen enclosure. A baby fence does not meet the Land Development Code requirements. Please demonstrate the proposed fence meets Land Development Code requirements as per Chapter 4 of the Land Development Code. IF THERE IS TO BE A "FENCE BY OTHERS" THERE MUST BE A FENCE PERMIT (ACKNOWLEDGEMENT BY OWNER OF PROPERTY AS TO FENCE REQUIREMENTS) ON RECORD PRIOR TO ISSUANCE OF A POOL PERMIT. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤127.50) | 08/03/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/03/2023 |
| INSPECTION- POOL | ¤160.00 | 08/03/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 08/03/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 08/03/2023 |
| SURCHARGE - FS 468.631 | ¤2.00 | 08/03/2023 |
| SW ENG INSPECTION 40 | ¤40.00 | 08/03/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 08/03/2023 |
| SITE PLAN 30 | ¤30.00 | 08/03/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤221.50 |