I want to search for...

Permit #2023061150

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7003-00190-0070
Block: 00190
Subdivision: 2190 - SECTION 3-COUNTRY CLUB COVE
Job Phone: 386-212-2958
Location Address: 7 CASTLE CT
Type: PO - POOL
Issue Date: 08/09/2023
NOC: RECORDED
Applicant name: COBY KYLE MOORE
Owner: ZULLER MICHAEL & HOLLY ADAMONIS-ZULLER H&W

Address

7 CASTLE COURT

PALM COAST, FL 32137

Lot: 0070
Contracted Stated Job Value: ¤72,000.00
Job Description: SWIMMING POOL -EXISTING FENCE FOR OUTER SAFETY
Type: CN

Contractor

CM DESIGNS INC.
Status Location Address State License Number Phone Fax
ACTIVE

1050 ROBERTS STREET

ORMOND BEACH, FL 32174

CPC1456991 (Exp: 08/31/2026) (386)615-7425 386-676-2963

Sub Contractors

GREGORY ALAN WARD
Status Location Address State License Number Phone
INACTIVE

P.O. BOX 731453

ORMOND BEACH, FL 32174

EC13005000 (Exp: 08/31/2026) 386-566-7248

Inspection History

Type Request Date Result Inspector
POOL FINAL 05/14/2024 FINAL APPROVED LMILLER
Note: 5-14-24 Items listed below resolved New inspection due to canceled inspection 5/3/2024 - PREVIOUS INSPECTION NOTES FBCR- Chapter 45 1. Left side gate will not self close and latch. Gates are to be self latching and self closing. 2. The gap between the bottom of the barriers and the finish grade can be no more than 2". Check the fences and right side gate at reispection. 3. The lower fence at the left side of the yard is not meeting the minimum height off finsih grade to top of barrier of 48".
POOL FINAL 05/08/2024 CANCELLED BY APPLICANT WEB
Note: 5/3/2024 - PREVIOUS INSPECTION NOTES FBCR- Chapter 45 1. Left side gate will not self close and latch. Gates are to be self latching and self closing. 2. The gap between the bottom of the barriers and the finish grade can be no more than 2". Check the fences and right side gate at reispection. 3. The lower fence at the left side of the yard is not meeting the minimum height off finsih grade to top of barrier of 48".
POOL FINAL 05/03/2024 Disapproved - NO FEE JWALKER
Note: FBCR- Chapter 45 1. Left side gate will not self close and latch. Gates are to be self latching and self closing. 2. The gap between the bottom of the barriers and the finish grade can be no more than 2". Check the fences and right side gate at reispection. 3. The lower fence at the left side of the yard is not meeting the minimum height off finsih grade to top of barrier of 48".
U -UTILITY RESIDENTIAL FINAL 05/02/2024 FINAL APPROVED LFITZGERALD
ROW FIELD SURVEY /GRADING CERTIFICATION 04/26/2024 APPROVED EMADISON
Note: ** 04/26/24 SPOKE WITH HOMEOWNER NO ISSUES WITH DRAINAGE __________________________________________________________________________________________________________________ 4/25/2024 - PREVIOUS INSPECTION NOTES ** 04/25/24 INSPECTOR UNABLE TO CONDUCT THE FIELD SURVEY INSPECTION, AS THERE IS A PRIVACEY FENCE AROUND PROPERTY THAT THE INSPECTOR NEEDS PERMISSION TO ENTER. INSPECTOR RANG DOORBELL NO ONE ANSWERED DOOR TO GRANT PERMISSION . ** BUILDER CAN LEAVE A NOTE IN APPLICANT NOTES STATING HOMEOWNER GIVES PERMISSION TO ENTER THE PROPERTY BEHIND THE FENCE OR SOMEONE NEEDS TO BE HOME TO GRANT ACCESS
ROW - FINAL INSPECTION 04/26/2024 APPROVED EMADISON
Note: ** At the time of the inspection all minimum city requirements were met. It is the builder’s responsibility to ensure that nothing changes after this Inspection is approved.
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/25/2024 APPROVED EMADISON
Note:
ROW FIELD SURVEY /GRADING CERTIFICATION 04/25/2024 Disapproved - NO FEE EMADISON
Note: ** 04/25/24 INSPECTOR UNABLE TO CONDUCT THE FIELD SURVEY INSPECTION, AS THERE IS A PRIVACEY FENCE AROUND PROPERTY THAT THE INSPECTOR NEEDS PERMISSION TO ENTER. INSPECTOR RANG DOORBELL NO ONE ANSWERED DOOR TO GRANT PERMISSION . ** BUILDER CAN LEAVE A NOTE IN APPLICANT NOTES STATING HOMEOWNER GIVES PERMISSION TO ENTER THE PROPERTY BEHIND THE FENCE OR SOMEONE NEEDS TO BE HOME TO GRANT ACCESS
ROW- FINAL SURVEY/GRADING CERTIFICATION 04/11/2024 Disapproved - NO FEE FSLADISH
Note: 4/11/24 THIS IS A BOUNDARY SURVEY. WE NEED A SURVEY WITH ELAVATIONS TO DETERMINE IF THE DRAINGE CONFORMS TO COPC STANDARDS.
ELECTRIC AND ALARM 01/30/2024 APPROVED AGAETANO
POOL DECK 12/13/2023 APPROVED FWILLIS
STEEL AND GROUND 10/09/2023 APPROVED AGAETANO

Review History

Department Status Date In Date Out
BLD COMPLETE 08/04/2023 08/04/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 08/04/2023 08/04/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
SW1 COMPLETE 08/04/2023 08/09/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
BLD HOLD 06/22/2023 06/26/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Provide detail or note on plans showing existing fence or screen enclosure complies with R4501.17.1.8. Show door swing and latch height.
ELEC COMPLETE 06/22/2023 06/26/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 06/22/2023 06/23/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/22/2023 06/28/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON HOLD 06/22/2023 06/26/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: Provide deck dimesions on the site plan and the pool plan deck was not included Show how fence will enclose the pool around the property on the site plan

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 50% (¤127.50) 08/09/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/09/2023
INSPECTION- POOL ¤160.00 08/09/2023
PLAN REVIEW - RESIDENTIAL ¤65.00 08/09/2023
SURCHARGE FS 533.721 ¤2.00 08/09/2023
SURCHARGE - FS 468.631 ¤2.00 08/09/2023
SW ENG INSPECTION 40 ¤40.00 08/09/2023
SW ENG - REVIEW 20 ¤20.00 08/09/2023
SITE PLAN 30 ¤30.00 08/09/2023
Fees Total Due: ¤0.00 Total Paid: ¤221.50