I want to search for...
Permit #2023061332
Permit Details
Status: COED
| Parcel Id: 07-11-31-7057-00120-0020 |
| GARAGE: 422 sqft |
| OPENED PORCH (WITH ROOF) : 155 sqft |
| CONDITIONED SPACE: 1621 sqft |
| Total Square Footage: 2198 sqft |
| Block: 00120 |
| Subdivision: 2123 - SECTION 57-ULYSSES TREES |
| Job Phone: 229-375-9123 |
| Location Address: 9 UTICA PATH |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 07/14/2023 |
| NOC: RECORDED |
| Applicant name: WILLIAM ROBERT BARRICK |
| Owner: NOU THERITH & CHANDA H&W |
|
Address 115 ULATURN TRL PALM COAST, FL 32164 |
| Lot: 0020 |
| Contracted Stated Job Value: ¤259,360.00 |
| Job Description: single family residence |
| Type: CN |
Contractor
RBI HOMES
| Status | Location Address | State License Number | Phone |
| CANCEL |
21 CEDARWOOD CT PALM COAST, FL 32137 |
RB29003845 (Exp: 08/31/2025) | 386-585-4097 |
Sub Contractors
WILLIAM ROBERT BARRICK
| Status | Location Address | Mailing Address | State License Number | Phone |
| CANCEL |
50 LEANNI WAY PALM COAST, FL 32137 |
STE E2 PALM COAST, FL 32137 |
RC29027799 (Exp: 08/31/2025) | 229-375-9123 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 912 PALM COAST, FL 32164 |
CAC1820539 (Exp: 08/31/2026) | 386-264-0550 |
DAVID SCOTT MORRIS
| Status | Location Address | State License Number | Phone |
| INACTIVE |
63 LEIDEL DR PALM COAST, FL 32137 |
ER13015750 (Exp: 08/31/2026) | 386-569-7262 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 02/05/2024 | FINAL APPROVED | BTAYLOR |
| Note: 9/13/23: Need revision submitted to & approved by the City for the different underlayment installed (Barricade UDL pro synthetic) than what was originally submitted. (GAF self adhering). | |||
| U-CROSS CONNECTION | 02/02/2024 | APPROVED - AS NOTED | JHARDING |
| Note: No irrigation, no cross connections. | |||
| ROW - FINAL APRON (AFTER POUR) | 02/02/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 2/2/24 PIPE IS OK. CUTS MADE. CULVERT ENDS CLEANED OUT. HOT PATCH COMPLETED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 2/1/24 UPON WALKING PROPERTY DETERMINED THAT THERE IS CORRECTION NEED ON THE RIGHT SIDE SWALE AT THE PROPERTY LINE. THERE IS A WASHOUT THAT NEEDS TO BE REPAIRED, SLOPED AND THE HIGH SPOT TAKEN OUT. ON THELEFT SIDE SWALE AT PROPERTY LINE YOU WILL NEED TO MATCH GRADE BEFORE ROW FINAL WILL BE PASSED. OTHER CORRECTIONS MAY BE REQUIRED BADES ON CONDITIONS IN ANY FUTURE INSPECTIONS. APPROVING THIS FIELD SURVEY AS NOTED. | |||
| ROW - STORMWATER FINAL | 02/02/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 2/2/24 SWALE SOD CORRECTION MADE. MET WITH CM AND I AM GOING TO APPROVE THIS INSPECTION AS NOTED THAT HE KNOWS AND WILL TAKE CARE OF TODAY, A FEW PIECES OF SOD ON TWO SMALL BARE AREAS ARE REQUIRED. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. _________________________________________________________________________________________________________________________ Inspector Notes from Inspection 9465 2/1/24 UPON WALKING PROPERTY DETERMINED THAT THERE IS CORRECTION NEED ON THE RIGHT SIDE SWALE AT THE PROPERTY LINE. THERE IS A WASHOUT THAT NEEDS TO BE REPAIRED, SLOPED AND THE HIGH SPOT TAKEN OUT. ON THELEFT SIDE SWALE AT PROPERTY LINE YOU WILL NEED TO MATCH GRADE BEFORE ROW FINAL WILL BE PASSED. OTHER CORRECTIONS MAY BE REQUIRED BADES ON CONDITIONS IN ANY FUTURE INSPECTIONS. APPROVING THIS FIELD SURVEY AS NOTED. | |||
| U -UTILITY RESIDENTIAL FINAL | 02/02/2024 | FINAL APPROVED | JHARDING |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/01/2024 | APPROVED | FSLADISH |
| Note: Inspector Notes from Inspection 9270 12/13/23 ** READY TO POUR IN THE FUTURE PLEASE DO NOT SECURE FRONT FORM BOARD TO ASPHALT. THERE SHOULD BE NO WOOD OR OTHER CONSTRUCTION MATERIAL IN THE ROADWAY.At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/01/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 2/1/24 UPON WALKING PROPERTY DETERMINED THAT THERE IS CORRECTION NEED ON THE RIGHT SIDE SWALE AT THE PROPERTY LINE. THERE IS A WASHOUT THAT NEEDS TO BE REPAIRED, SLOPED AND THE HIGH SPOT TAKEN OUT. ON THELEFT SIDE SWALE AT PROPERTY LINE YOU WILL NEED TO MATCH GRADE BEFORE ROW FINAL WILL BE PASSED. OTHER CORRECTIONS MAY BE REQUIRED BADES ON CONDITIONS IN ANY FUTURE INSPECTIONS. APPROVING THIS FIELD SURVEY AS NOTED. | |||
| ROW- PRE-APRON (PRE-POUR) | 12/13/2023 | APPROVED - AS NOTED | TPOLACEK |
| Note: 12/13/23 ** READY TO POUR IN THE FUTURE PLEASE DO NOT SECURE FRONT FORM BOARD TO ASPHALT. THERE SHOULD BE NO WOOD OR OTHER CONSTRUCTION MATERIAL IN THE ROADWAY.At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. | |||
| U - SEWER TIE IN | 12/01/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 12/01/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ELECTRIC - EARLY POWER | 11/30/2023 | APPROVED - AS NOTED | BTAYLOR |
| Note: 11-30-23 1. Emailed FPL at 2:30. | |||
| INSULATION | 10/12/2023 | APPROVED | BTAYLOR |
| LATH/BRICK/ WATER BARRIER | 10/10/2023 | APPROVED | BTAYLOR |
| ALL ROUGH | 10/09/2023 | APPROVED | BTAYLOR |
| ROOF VALLEY & METAL | 09/18/2023 | APPROVED | BTAYLOR |
| Note: 9/13/2023 - PREVIOUS INSPECTION NOTES 9/13/23: Need revision submitted to & approved by the City for the different underlayment installed (Barricade UDL pro synthetic) than what was originally submitted. (GAF self adhering). 1). Also, missing 5" x 5" wall flashing at front entry vertical walls. 9/11/2023 - PREVIOUS INSPECTION NOTES 9-11-23 1. Underlaminate not nailed off properly. | |||
| ROOF VALLEY & METAL | 09/13/2023 | Disapproved - NO FEE | RSIMS |
| Note: 9/13/23: Need revision submitted to & approved by the City for the different underlayment installed (Barricade UDL pro synthetic) than what was originally submitted. (GAF self adhering). 1). Also, missing 5" x 5" wall flashing at front entry vertical walls. 9/11/2023 - PREVIOUS INSPECTION NOTES 9-11-23 1. Underlaminate not nailed off properly. | |||
| WALL SHEATHING | 09/11/2023 | APPROVED | BTAYLOR |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 09/11/2023 | APPROVED | BTAYLOR |
| ROOF VALLEY & METAL | 09/11/2023 | Disapproved - NO FEE | BTAYLOR |
| Note: 9-11-23 1. Underlaminate not nailed off properly. | |||
| FOUND SURVEY APPROVED (OFFICE) | 09/08/2023 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 08/23/2023 | APPROVED | BTAYLOR |
| MONOLITHIC SLAB | 08/16/2023 | APPROVED | BTAYLOR |
| Note: 8/15/2023 - PREVIOUS INSPECTION NOTES 8-15-23 1. Reinforced footer's not built per detail. | |||
| MONOLITHIC SLAB | 08/15/2023 | Disapproved - NO FEE | BTAYLOR |
| Note: 8-15-23 1. Reinforced footer's not built per detail. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 08/10/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 08/01/2023 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 01/10/2024 | 01/10/2024 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM address doesn't match permit. | |||
| MECH | COMPLETE | 01/05/2024 | 01/09/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/11/2023 | 12/11/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/13/2023 | 09/15/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/07/2023 | 09/08/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/07/2023 | 09/07/2023 |
| Note: Released By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 08/25/2023 | 08/25/2023 |
| Note: Marked INFORMATION By: LIBBY MUSGROVE - - LMUSGROVE@PALMCOASTGOV.COM WE do not review Formboard surveys - only foundation | |||
| BADMIN | INFORMATION | 07/14/2023 | 07/14/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM The owner address and contractor address needs to be a complete address. The purpose of the NOC is to provide contact infromation for notice to owners to be sent. This needs to be corrected AND rerecorded. IN addition, the description of improvement should be what you are building 'single family residence' | |||
| ZON | COMPLETE | 07/07/2023 | 07/07/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/07/2023 | 07/13/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 06/27/2023 | 06/29/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Complete truss plan packet cover sheet or first page to include the design professional of record (building design engineer or architect) approval stamp indicating acceptance and approval of truss design (Not wet seal) | |||
| CUSVC | COMPLETE | 06/27/2023 | 06/30/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 06/27/2023 | 06/30/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/27/2023 | 06/27/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 06/27/2023 | 06/27/2023 |
| LOCATE | COMPLETE | 06/27/2023 | 06/28/2023 |
| Note: Released By: CANDACE STONE - (386)986-2539 - CSTONE@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/27/2023 | 06/28/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/27/2023 | 07/05/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/27/2023 | 06/27/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Color sheet missing the color name Must have a minimum four shrubs along each front side wrapping corners | |||
| SWALE | COMPLETE | 06/27/2023 | 08/04/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 02/05/2024 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 07/14/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 07/14/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 07/14/2023 |
| IMPACT FEE FIRE | ¤420.52 | 07/14/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 07/14/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 07/14/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 07/14/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 07/14/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 07/14/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 07/14/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 07/14/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 07/14/2023 |
| SURCHARGE FS 533.721 | ¤4.74 | 07/14/2023 |
| SURCHARGE - FS 468.631 | ¤7.11 | 07/14/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 07/14/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 07/14/2023 |
| SW ENG PRE APRON | ¤30.00 | 07/14/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 07/14/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/14/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 07/14/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 07/14/2023 |
| SEWER CREDIT | (¤850.00) | 07/14/2023 |
| SEWER INSPECTION | ¤25.00 | 07/14/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 07/14/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 07/14/2023 |
| SITE PLAN 30 | ¤30.00 | 07/14/2023 |
| WATER- TURN ON | ¤25.00 | 07/14/2023 |
| ADJUSTMENT 50% | (¤473.90) | 07/14/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/14/2023 |
| INSPECTION - RESIDENTIAL | ¤715.00 | 07/14/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤202.80 | 07/14/2023 |
| CONNECTION FEES | ¤1,166.26 | 07/14/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,545.38 |