I want to search for...

Permit #2023070150

Permit Details

Status: COED

Parcel Id: 07-11-31-7060-00280-0180
CONDITIONED SPACE: 1880 sqft
GARAGE: 487 sqft
OPENED PORCH (WITH ROOF) : 300 sqft
OPENED PORCH (WITH ROOF) : 32 sqft
Total Square Footage: 2699 sqft
Block: 00280
Subdivision: -
Job Phone: 386-871-8082
Location Address: 99 SLOGANEER TR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/24/2023
NOC: RECORDED
Applicant name: GAYLORD JAY DOWNER
Owner: DOWNER JAMES

Address

100 E KENTUCKY AVE H-105

DELAND, FL 32724

Lot: 0180
Contracted Stated Job Value: ¤325,000.00
Job Description: Single Family Residence
Type: CN

Contractor

TRIAD BUILDING GROUP, LLC
Status Location Address State License Number Phone
ACTIVE

1280 BISCAYNE BLVD # 11

DELAND, FL 32724

CBC1262885 (Exp: 08/31/2026) 386-873-2791

Sub Contractors

FRED L HOUGH JR
Status Location Address State License Number Phone
ACTIVE

4740 HIGHWAY 11

DE LEON SPRINGS, FL 32130

EC13010201 (Exp: 08/31/2026) 386-736-0253
RICHARD LEE VONBROCKEN
Status Location Address State License Number Phone Fax
INACTIVE

1738 STATE AVE

HOLLY HILL, FL 32117

CAC035516 (Exp: 08/31/2026) (386)672-1950 (386)672-1952
GAYLORD JAY DOWNER
Status Location Address State License Number Phone
ACTIVE

1280 BISCAYNE BLVD # 11

DELAND, FL 32724

CBC1262885 (Exp: 08/31/2026) 386-873-2791
ROBERTO F GONZALEZ
Status Location Address State License Number Phone
ACTIVE

212 PALMETTO AVE

CRESCENT CITY, FL 32112

RF11067887 (Exp: 08/31/2027) 286-559-2885

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 04/12/2024 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-nobcross connection
BLD - BUILDING FINAL 04/10/2024 FINAL APPROVED BTAYLOR
Note: 3/28/2024 - PREVIOUS INSPECTION NOTES 3-28-24 1. Energy cals do not match equiptment installed.
BLD - BUILDING FINAL 03/28/2024 Disapproved - NO FEE BTAYLOR
Note: 3-28-24 1. Energy cals do not match equiptment installed.
U -UTILITY RESIDENTIAL FINAL 03/20/2024 FINAL APPROVED JHARDING
Note: 3/19/2024 - PREVIOUS INSPECTION NOTES No power to pep panel
ROW - STORMWATER FINAL 03/19/2024 APPROVED TPOLACEK
Note: 03/19/24 AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
U -UTILITY RESIDENTIAL FINAL 03/19/2024 Disapproved - NO FEE JHARDING
Note: No power to pep panel
ROW - FINAL APRON (AFTER POUR) 03/15/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/15/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 03/15/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ELECTRIC - EARLY POWER 02/29/2024 APPROVED - AS NOTED BTAYLOR
Note: 2/26/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2200 12-13-23 1. Emailed FPL at 12:47. 2-26-24 1. All outlets in kitchen either pulled out or dont have covers on them. 2-29-24 1. Emailed FPL at 2:14.
ELECTRIC - EARLY POWER 02/26/2024 Disapproved - NO FEE BTAYLOR
Note: Inspector Notes from Inspection 2200 12-13-23 1. Emailed FPL at 12:47. 2-26-24 1. All outlets in kitchen either pulled out or dont have covers on them.
ROW- PRE-APRON (PRE-POUR) 02/21/2024 APPROVED - AS NOTED FSLADISH
Note: 2/21/24 PIPE IS WITHIN TOLERANCE. THEY ARE ADDING FRONT ROAD EDGE FORMBOARD AT THIS TIME. APPROVING AS NOTED. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. _______________________________________________________________________________________________________________________ 2/20/2024 - PREVIOUS INSPECTION NOTED
ROW- PRE-APRON (PRE-POUR) 02/20/2024 CANCELLED BY APPLICANT FSLADISH
U - SEWER TIE IN 02/16/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 NEED TO CHANGE PLUMBING SUB CONTRACTOR BEFORE NEXT INSPECTION
GRAVITY SEWER TEST 02/16/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 NEED TO CHANGE PLUMBING SUB CONTRACTOR BEFORE NEXT INSPECTION
PEP TANK INSTALLATION REQUEST 01/26/2024 APPROVED BVITALE
LATH/BRICK/ WATER BARRIER 01/04/2024 APPROVED BTAYLOR
INSULATION 12/20/2023 APPROVED BTAYLOR
ALL ROUGH 12/18/2023 APPROVED BTAYLOR
ELECTRIC-TUG 12/13/2023 APPROVED - AS NOTED BTAYLOR
Note: 12-13-23 1. Emailed FPL at 12:47.
ROOF VALLEY & METAL 12/08/2023 APPROVED BTAYLOR
Note: 12/5/2023 - PREVIOUS INSPECTION NOTES 12-5-23 1. Incorrect nailing pattern for underlaymant.
ROOF VALLEY & METAL 12/05/2023 Disapproved - NO FEE BTAYLOR
Note: 12-5-23 1. Incorrect nailing pattern for underlaymant.
WALL SHEATHING 11/29/2023 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/29/2023 APPROVED BTAYLOR
FOUND SURVEY APPROVED (OFFICE) 11/28/2023 APPROVED TBAKER
TIE BEAM / LINTEL 11/08/2023 APPROVED BTAYLOR
Note: 11/6/2023 - PREVIOUS INSPECTION NOTES 11/6/23: * no address marked as required.(FBC 319.1 / 501.2). * Missing dowels & rebar at 2 locations. Marked on plans * Window sill mortar beds along with mortar joints at precast window sills are too thick. 1/2" Max per FBC R606.3.1 Marked at sills & highlighted on plans. * Check mortar joints in between block that are excessive.
TIE BEAM / LINTEL 11/06/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/6/23: * no address marked as required.(FBC 319.1 / 501.2). * Missing dowels & rebar at 2 locations. Marked on plans * Window sill mortar beds along with mortar joints at precast window sills are too thick. 1/2" Max per FBC R606.3.1 Marked at sills & highlighted on plans. * Check mortar joints in between block that are excessive.
MONOLITHIC SLAB 10/24/2023 Disapproved -FEE REQUIRED RSIMS
Note: 10/23/23: Small (8" x 11") prints are not clearly legible. Large prints are not stamped approved. Please provide legible approved prints before re-inspection. (11" x 17" minimum preferably). 1). No compaction report. 2). Right side plumbing sleeve is not fully through the footer as required. (305.3).
MONOLITHIC SLAB 10/24/2023 APPROVED BTAYLOR
Note: 10/23/2023 - PREVIOUS INSPECTION NOTES 10/23/23: Small (8" x 11") prints are not clearly legible. Large prints are not stamped approved. Please provide legible approved prints before re-inspection. (11" x 17" minimum preferably). 1). No compaction report. 2). Right side plumbing sleeve is not fully through the footer as required. (305.3).
PLUMBING 1ST ROUGH UNDERGROUND 10/19/2023 APPROVED - AS NOTED MGIBSON
Note: NEED TO CHANGE PLUMBING SUB CONTRACTOR BEFORE NEXT INSPECTION
WATER METER INSTALLATION REQUEST 09/13/2023 APPROVED CBOWERMASTER
Note: 9/5/2023 12:39:23 PM- PREVIOUS INSPECTION NOTES wooded lot
WATER METER INSTALLATION REQUEST 09/05/2023 Disapproved -FEE REQUIRED CBOWERMASTER
Note: wooded lot

Review History

Department Status Date In Date Out
MECH COMPLETE 04/05/2024 04/08/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/28/2023 11/28/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 11/28/2023 11/28/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 08/23/2023 08/24/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC HOLD 08/22/2023 08/22/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Engineer plans still call out for a 400 amp service and so do the electric load calcs.
MECH HOLD 08/22/2023 08/23/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide heatload calculation. it is missing from Energy calcs
BLD COMPLETE 08/22/2023 08/23/2023
Note: Released By: JPI
ELEC COMPLETE 08/22/2023 08/22/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 08/02/2023 08/04/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide heatlaod and duct layout signed by AC contractor. 2. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition
ELEC HOLD 08/02/2023 08/03/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. 2/0 Alum. is not rated for the 400 mp service. NEC 2017 Table 310.15(B)(16)
ZON COMPLETE 08/02/2023 08/03/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD HOLD 08/02/2023 08/07/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
BLD HOLD 07/08/2023 07/16/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
BADMIN COMPLETE 07/08/2023 07/10/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 07/06/2023 07/07/2023
Note: Held By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Released By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
CUSVC COMPLETE 07/06/2023 07/10/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 07/06/2023 07/10/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Electrical load calculations do not match the living space of the house. NEC 2017 220 2. Submit a electrical riser diagram that includes all wire sizes and breaker sizes
ENGIN1 COMPLETE 07/06/2023 07/06/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 07/06/2023 07/10/2023
LOCATE COMPLETE 07/06/2023 07/10/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 07/06/2023 07/10/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide Entire heatload and duct layout signed by the AC contractor 2. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition
SW1 COMPLETE 07/06/2023 07/17/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON HOLD 07/06/2023 07/11/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide sod type and if irrigation will be installed on landscape plan Must have a minimum of four shrubs along each front side wrapping corners of home Horizontal band must wrap the left corner at least two foot
SWALE COMPLETE 07/06/2023 08/10/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 04/10/2024
REINSPECTION RESIDENTIAL ¤40.00 04/10/2024
REINSPECTION RESIDENTIAL ¤40.00 04/10/2024
CONTRACTOR CHANGE ¤20.00 04/10/2024
REINSPECTION FEE ¤40.00 04/10/2024
SURCHARGE FS 533.721 ¤5.89 08/24/2023
SURCHARGE - FS 468.631 ¤8.83 08/24/2023
SW ENG - FOUNDATION SURVEY ¤20.00 08/24/2023
SW ENG INSPECTION 80 ¤80.00 08/24/2023
SW ENG PRE APRON ¤30.00 08/24/2023
SW ENG - REVIEW 20 ¤20.00 08/24/2023
SW ENG RES REVIEW 200 ¤200.00 08/24/2023
TRANS IMPACT FEE ADMIN ¤54.36 08/24/2023
TRANS IMPACT FEE ADMIN (¤54.36) 08/24/2023
SEWER CREDIT (¤1,466.00) 08/24/2023
SEWER INSPECTION ¤25.00 08/24/2023
SEWER CAPITAL FACILITY ¤5,344.82 08/24/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 08/24/2023
SITE PLAN 30 ¤30.00 08/24/2023
FIRE IMPACT FEE ADMIN ¤12.62 08/24/2023
FIRE IMPACT FEE ADMIN (¤12.62) 08/24/2023
FC IMPACT FEE EMS ¤62.00 08/24/2023
IMPACT FEE FIRE ¤420.52 08/24/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 08/24/2023
FC IMPACT FEE LIBRARY ¤268.00 08/24/2023
IMPACT FEE PARKS ¤1,769.15 08/24/2023
IMPACT FEE SCHOOL ¤5,450.00 08/24/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 08/24/2023
WATER -IRRIGATION INSPECTION ¤25.00 08/24/2023
PARKS IMPACT FEE ADMIN ¤53.07 08/24/2023
PARKS IMPACT FEE ADMIN (¤53.07) 08/24/2023
CONNECTION FEES ¤1,166.26 08/24/2023
WATER- TURN ON ¤25.00 08/24/2023
ADJUSTMENT 50% (¤588.63) 08/24/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/24/2023
INSPECTION - RESIDENTIAL ¤893.75 08/24/2023
PLAN REVIEW - RESIDENTIAL ¤253.50 08/24/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,199.47