I want to search for...
Permit #2023070225
Permit Details
Status: COED
| Parcel Id: 07-11-31-7059-00170-0030 |
| CONDITIONED SPACE: 2306 sqft |
| GARAGE: 466 sqft |
| OPENED PORCH (WITH ROOF) : 170 sqft |
| Total Square Footage: 2942 sqft |
| Block: 00170 |
| Subdivision: 2211 - SECTION 59-SEMINOLE PARK |
| Job Phone: 831-383-2883 |
| Location Address: 2 SEA SWIRL PL |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 02/06/2024 |
| NOC: RECORDED |
| Applicant name: EDWARD LEE DAUBERT JR |
| Owner: FLORIDA SUN PARTNERS II LLC |
|
Address 6751 FORUM DRIVE SUITE 210 ORLANDO, FL 32821 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤220,324.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
BRITE BUILDING GROUP LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6751 FORUM DRIVE SUITE 210 ORLANDO, FL 32821 |
CBC1266303 (Exp: 08/31/2026) | 831-383-2883 |
Sub Contractors
DUSTIN L ESTEP
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2041 N HIAWASSEE RD APOPKA, FL 32703 |
CCC1330971 (Exp: 08/31/2026) | 407-702-0206 | 352-988-6629 |
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CAC1820196 (Exp: 08/31/2026) | 407-404-4000 |
ANTHONY OKEITH FENNELL
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N. WESTMONTE DR, SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
EC13011194 (Exp: 08/31/2026) | 407-404-4000 |
JASON LEE JAMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
217 N WESTMONTE DR SUITE 1007 ALTAMONTE SPRINGS, FL 32714 |
CFC1430061 (Exp: 08/31/2026) | 407-404-4000 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 09/25/2024 | APPROVED | FSLADISH |
| Note: 9/25/24 PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ______________________________________________________________________________________________________________________ 9/23/2024 - PREVIOUS INSPECTION NOTES CANCELED BY TEXT -------------------------------------------------- 9/13/24 UPON WALKING PROPERTY FOUND AREAS OF WASHOUTS ON BOTH SIDES OF DRIVEWAY NEAR MITERED ENDS AND DRIVEWAY APRON. THERE ARE AREAS ON THE LEFT SIDE PROPERTY LINE THAT WILL NEED TO BE FILLED IN, COMPACTED AND SODDED TO MATCH GRADE. IN THE REAR LEFT CORNER THERE IS A GOOD AMOUNT OF STANDING WATER IN AN AREA THAT APPEARS TO HAVE BEEN DISTURBED DURING CLEARING. I CALLED CM DAN AND ASKED HIM FOR ANY INFO AND LET HIM KNOW THAT UNLESS WE HAVE PHOTOS AND A COMMUNICATION TRAIL THAT THIS WAS EXISTING PRE CLEARING, THEY WOULD BE REQUIRED TO CORRECT THIS AREA TO AS GOOD OR BETTER CONDITION. HE INDICATED HE DID NOT KNOW BUT WOULD CONTACT THE NEIGHBOR TO FIND OUT INFORMATION REGARDING THIS. HE INDICATED THAT THEY WOULD FIX THIS AREA IF NEED BE. BASED ON THIS CONVERSATION AS A COURTESY I LET HIM KNOW THAT I WOULD PASS THE FIELD SURVEY AS NOTED WITH THE CAVEAT THAT THESE AREAS WILL NEED TO BE REPAIRED BEFORE A ROW FINAL PASSAGE. HE AGREED. PHOTOS FOR REFERENCE. Inspector Notes from Inspection 9463 9/12/24 ELEVATION SHOTS AGAINST STRUCTURE PROVIDED AS REQUIRED. ELEVATION SHOT IN SWALE AT CORNER REVISED TO INDICATE FLOW AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED THAT I WILL VERIFY ON FIELD SURVEY INSPECTION. __________________________________________________________________________________________________________________________ 9/10/2024 - PREVIOUS INSPECTION NOTES 9/10/24 YOU NEED TO PROVIDE ELEVATION SHOTS ON ALL CORNERS OF THE STUCTURE AND EVERY 20 FT ALONG IT. SO WE CAN DETERMINE IF IT MEETS BELOW FFE REQUIREMENTS. FRONT TWO CORNERS HAVE NO ELEVATION SHOTS. YOU ARE SHOWING YOU SWALE TO BE 5 TENTHS HIGHER (25.3) AT THE CORNER THAN THE PREVIOUS SHOT OF 24.8 UPSTREAM. THIS WILL IMPEDE DRAINAGE FLOW AND CAUSE WATER TO POOL IN THIS AREA. Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for woodframe structures. (H) Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT WITHIN SWALE PLAN DIAGRAM TOLERANCE. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9463 9/12/24 ELEVATION SHOTS AGAINST STRUCTURE PROVIDED AS REQUIRED. ELEVATION SHOT IN SWALE AT CORNER REVISED TO INDICATE FLOW AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED THAT I WILL VERIFY ON FIELD SURVEY INSPECTION. __________________________________________________________________________________________________________________________ 9/10/2024 - PREVIOUS INSPECTION NOTES 9/10/24 YOU NEED TO PROVIDE ELEVATION SHOTS ON ALL CORNERS OF THE STUCTURE AND EVERY 20 FT ALONG IT. SO WE CAN DETERMINE IF IT MEETS BELOW FFE REQUIREMENTS. FRONT TWO CORNERS HAVE NO ELEVATION SHOTS. YOU ARE SHOWING YOU SWALE TO BE 5 TENTHS HIGHER (25.3) AT THE CORNER THAN THE PREVIOUS SHOT OF 24.8 UPSTREAM. THIS WILL IMPEDE DRAINAGE FLOW AND CAUSE WATER TO POOL IN THIS AREA. Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for woodframe structures. (H) Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT WITHIN SWALE PLAN DIAGRAM TOLERANCE. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| ROW - STORMWATER FINAL | 09/25/2024 | APPROVED | FSLADISH |
| Note: 9/25/24 AT THE TIME OF THIS THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ________________________________________________________________________________________________________________________ 9/23/2024 - PREVIOUS INSPECTION NOTES CANCELED BY TEXT --------------------------------------------- 9/13/24 UPON WALKING PROPERTY FOUND AREAS OF WASHOUTS ON BOTH SIDES OF DRIVEWAY NEAR MITERED ENDS AND DRIVEWAY APRON. THERE ARE AREAS ON THE LEFT SIDE PROPERTY LINE THAT WILL NEED TO BE FILLED IN, COMPACTED AND SODDED TO MATCH GRADE. IN THE REAR LEFT CORNER THERE IS A GOOD AMOUNT OF STANDING WATER IN AN AREA THAT APPEARS TO HAVE BEEN DISTURBED DURING CLEARING. I CALLED CM DAN AND ASKED HIM FOR ANY INFO AND LET HIM KNOW THAT UNLESS WE HAVE PHOTOS AND A COMMUNICATION TRAIL THAT THIS WAS EXISTING PRE CLEARING, THEY WOULD BE REQUIRED TO CORRECT THIS AREA TO AS GOOD OR BETTER CONDITION. HE INDICATED HE DID NOT KNOW BUT WOULD CONTACT THE NEIGHBOR TO FIND OUT INFORMATION REGARDING THIS. HE INDICATED THAT THEY WOULD FIX THIS AREA IF NEED BE. BASED ON THIS CONVERSATION AS A COURTESY I LET HIM KNOW THAT I WOULD PASS THE FIELD SURVEY AS NOTED WITH THE CAVEAT THAT THESE AREAS WILL NEED TO BE REPAIRED BEFORE A ROW FINAL PASSAGE. HE AGREED. PHOTOS FOR REFERENCE. Inspector Notes from Inspection 9463 9/12/24 ELEVATION SHOTS AGAINST STRUCTURE PROVIDED AS REQUIRED. ELEVATION SHOT IN SWALE AT CORNER REVISED TO INDICATE FLOW AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED THAT I WILL VERIFY ON FIELD SURVEY INSPECTION. __________________________________________________________________________________________________________________________ 9/10/2024 - PREVIOUS INSPECTION NOTES 9/10/24 YOU NEED TO PROVIDE ELEVATION SHOTS ON ALL CORNERS OF THE STUCTURE AND EVERY 20 FT ALONG IT. SO WE CAN DETERMINE IF IT MEETS BELOW FFE REQUIREMENTS. FRONT TWO CORNERS HAVE NO ELEVATION SHOTS. YOU ARE SHOWING YOU SWALE TO BE 5 TENTHS HIGHER (25.3) AT THE CORNER THAN THE PREVIOUS SHOT OF 24.8 UPSTREAM. THIS WILL IMPEDE DRAINAGE FLOW AND CAUSE WATER TO POOL IN THIS AREA. Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for woodframe structures. (H) Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT WITHIN SWALE PLAN DIAGRAM TOLERANCE. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9463 9/12/24 ELEVATION SHOTS AGAINST STRUCTURE PROVIDED AS REQUIRED. ELEVATION SHOT IN SWALE AT CORNER REVISED TO INDICATE FLOW AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED THAT I WILL VERIFY ON FIELD SURVEY INSPECTION. __________________________________________________________________________________________________________________________ 9/10/2024 - PREVIOUS INSPECTION NOTES 9/10/24 YOU NEED TO PROVIDE ELEVATION SHOTS ON ALL CORNERS OF THE STUCTURE AND EVERY 20 FT ALONG IT. SO WE CAN DETERMINE IF IT MEETS BELOW FFE REQUIREMENTS. FRONT TWO CORNERS HAVE NO ELEVATION SHOTS. YOU ARE SHOWING YOU SWALE TO BE 5 TENTHS HIGHER (25.3) AT THE CORNER THAN THE PREVIOUS SHOT OF 24.8 UPSTREAM. THIS WILL IMPEDE DRAINAGE FLOW AND CAUSE WATER TO POOL IN THIS AREA. Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for woodframe structures. (H) Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT WITHIN SWALE PLAN DIAGRAM TOLERANCE. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| ROW - STORMWATER FINAL | 09/23/2024 | CANCELLED BY APPLICANT | PFLANAGAN |
| Note: CANCELED BY TEXT --------------------------------------------- 9/13/24 UPON WALKING PROPERTY FOUND AREAS OF WASHOUTS ON BOTH SIDES OF DRIVEWAY NEAR MITERED ENDS AND DRIVEWAY APRON. THERE ARE AREAS ON THE LEFT SIDE PROPERTY LINE THAT WILL NEED TO BE FILLED IN, COMPACTED AND SODDED TO MATCH GRADE. IN THE REAR LEFT CORNER THERE IS A GOOD AMOUNT OF STANDING WATER IN AN AREA THAT APPEARS TO HAVE BEEN DISTURBED DURING CLEARING. I CALLED CM DAN AND ASKED HIM FOR ANY INFO AND LET HIM KNOW THAT UNLESS WE HAVE PHOTOS AND A COMMUNICATION TRAIL THAT THIS WAS EXISTING PRE CLEARING, THEY WOULD BE REQUIRED TO CORRECT THIS AREA TO AS GOOD OR BETTER CONDITION. HE INDICATED HE DID NOT KNOW BUT WOULD CONTACT THE NEIGHBOR TO FIND OUT INFORMATION REGARDING THIS. HE INDICATED THAT THEY WOULD FIX THIS AREA IF NEED BE. BASED ON THIS CONVERSATION AS A COURTESY I LET HIM KNOW THAT I WOULD PASS THE FIELD SURVEY AS NOTED WITH THE CAVEAT THAT THESE AREAS WILL NEED TO BE REPAIRED BEFORE A ROW FINAL PASSAGE. HE AGREED. PHOTOS FOR REFERENCE. Inspector Notes from Inspection 9463 9/12/24 ELEVATION SHOTS AGAINST STRUCTURE PROVIDED AS REQUIRED. ELEVATION SHOT IN SWALE AT CORNER REVISED TO INDICATE FLOW AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED THAT I WILL VERIFY ON FIELD SURVEY INSPECTION. __________________________________________________________________________________________________________________________ 9/10/2024 - PREVIOUS INSPECTION NOTES 9/10/24 YOU NEED TO PROVIDE ELEVATION SHOTS ON ALL CORNERS OF THE STUCTURE AND EVERY 20 FT ALONG IT. SO WE CAN DETERMINE IF IT MEETS BELOW FFE REQUIREMENTS. FRONT TWO CORNERS HAVE NO ELEVATION SHOTS. YOU ARE SHOWING YOU SWALE TO BE 5 TENTHS HIGHER (25.3) AT THE CORNER THAN THE PREVIOUS SHOT OF 24.8 UPSTREAM. THIS WILL IMPEDE DRAINAGE FLOW AND CAUSE WATER TO POOL IN THIS AREA. Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for woodframe structures. (H) Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT WITHIN SWALE PLAN DIAGRAM TOLERANCE. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9463 9/12/24 ELEVATION SHOTS AGAINST STRUCTURE PROVIDED AS REQUIRED. ELEVATION SHOT IN SWALE AT CORNER REVISED TO INDICATE FLOW AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED THAT I WILL VERIFY ON FIELD SURVEY INSPECTION. __________________________________________________________________________________________________________________________ 9/10/2024 - PREVIOUS INSPECTION NOTES 9/10/24 YOU NEED TO PROVIDE ELEVATION SHOTS ON ALL CORNERS OF THE STUCTURE AND EVERY 20 FT ALONG IT. SO WE CAN DETERMINE IF IT MEETS BELOW FFE REQUIREMENTS. FRONT TWO CORNERS HAVE NO ELEVATION SHOTS. YOU ARE SHOWING YOU SWALE TO BE 5 TENTHS HIGHER (25.3) AT THE CORNER THAN THE PREVIOUS SHOT OF 24.8 UPSTREAM. THIS WILL IMPEDE DRAINAGE FLOW AND CAUSE WATER TO POOL IN THIS AREA. Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for woodframe structures. (H) Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT WITHIN SWALE PLAN DIAGRAM TOLERANCE. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| ROW - FINAL APRON (AFTER POUR) | 09/23/2024 | CANCELLED BY APPLICANT | PFLANAGAN |
| Note: CANCELED BY TEXT -------------------------------------------------- 9/13/24 UPON WALKING PROPERTY FOUND AREAS OF WASHOUTS ON BOTH SIDES OF DRIVEWAY NEAR MITERED ENDS AND DRIVEWAY APRON. THERE ARE AREAS ON THE LEFT SIDE PROPERTY LINE THAT WILL NEED TO BE FILLED IN, COMPACTED AND SODDED TO MATCH GRADE. IN THE REAR LEFT CORNER THERE IS A GOOD AMOUNT OF STANDING WATER IN AN AREA THAT APPEARS TO HAVE BEEN DISTURBED DURING CLEARING. I CALLED CM DAN AND ASKED HIM FOR ANY INFO AND LET HIM KNOW THAT UNLESS WE HAVE PHOTOS AND A COMMUNICATION TRAIL THAT THIS WAS EXISTING PRE CLEARING, THEY WOULD BE REQUIRED TO CORRECT THIS AREA TO AS GOOD OR BETTER CONDITION. HE INDICATED HE DID NOT KNOW BUT WOULD CONTACT THE NEIGHBOR TO FIND OUT INFORMATION REGARDING THIS. HE INDICATED THAT THEY WOULD FIX THIS AREA IF NEED BE. BASED ON THIS CONVERSATION AS A COURTESY I LET HIM KNOW THAT I WOULD PASS THE FIELD SURVEY AS NOTED WITH THE CAVEAT THAT THESE AREAS WILL NEED TO BE REPAIRED BEFORE A ROW FINAL PASSAGE. HE AGREED. PHOTOS FOR REFERENCE. Inspector Notes from Inspection 9463 9/12/24 ELEVATION SHOTS AGAINST STRUCTURE PROVIDED AS REQUIRED. ELEVATION SHOT IN SWALE AT CORNER REVISED TO INDICATE FLOW AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED THAT I WILL VERIFY ON FIELD SURVEY INSPECTION. __________________________________________________________________________________________________________________________ 9/10/2024 - PREVIOUS INSPECTION NOTES 9/10/24 YOU NEED TO PROVIDE ELEVATION SHOTS ON ALL CORNERS OF THE STUCTURE AND EVERY 20 FT ALONG IT. SO WE CAN DETERMINE IF IT MEETS BELOW FFE REQUIREMENTS. FRONT TWO CORNERS HAVE NO ELEVATION SHOTS. YOU ARE SHOWING YOU SWALE TO BE 5 TENTHS HIGHER (25.3) AT THE CORNER THAN THE PREVIOUS SHOT OF 24.8 UPSTREAM. THIS WILL IMPEDE DRAINAGE FLOW AND CAUSE WATER TO POOL IN THIS AREA. Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for woodframe structures. (H) Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT WITHIN SWALE PLAN DIAGRAM TOLERANCE. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9463 9/12/24 ELEVATION SHOTS AGAINST STRUCTURE PROVIDED AS REQUIRED. ELEVATION SHOT IN SWALE AT CORNER REVISED TO INDICATE FLOW AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED THAT I WILL VERIFY ON FIELD SURVEY INSPECTION. __________________________________________________________________________________________________________________________ 9/10/2024 - PREVIOUS INSPECTION NOTES 9/10/24 YOU NEED TO PROVIDE ELEVATION SHOTS ON ALL CORNERS OF THE STUCTURE AND EVERY 20 FT ALONG IT. SO WE CAN DETERMINE IF IT MEETS BELOW FFE REQUIREMENTS. FRONT TWO CORNERS HAVE NO ELEVATION SHOTS. YOU ARE SHOWING YOU SWALE TO BE 5 TENTHS HIGHER (25.3) AT THE CORNER THAN THE PREVIOUS SHOT OF 24.8 UPSTREAM. THIS WILL IMPEDE DRAINAGE FLOW AND CAUSE WATER TO POOL IN THIS AREA. Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for woodframe structures. (H) Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT WITHIN SWALE PLAN DIAGRAM TOLERANCE. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| BLD - BUILDING FINAL | 09/18/2024 | FINAL APPROVED | BTAYLOR |
| Note: 9/16/2024 - PREVIOUS INSPECTION NOTES 9-16-24 1. No hot water. 2. Air handler needs to have lockout breaker installed. | |||
| BLD - BUILDING FINAL | 09/16/2024 | Disapproved - NO FEE | BTAYLOR |
| Note: 9-16-24 1. No hot water. 2. Air handler needs to have lockout breaker installed. | |||
| U-CROSS CONNECTION | 09/16/2024 | APPROVED - AS NOTED | BWRIGHT |
| Note: IRR with potable water. PVB in place. No CC. | |||
| U -UTILITY RESIDENTIAL FINAL | 09/16/2024 | FINAL APPROVED | BWRIGHT |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/13/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 9/13/24 UPON WALKING PROPERTY FOUND AREAS OF WASHOUTS ON BOTH SIDES OF DRIVEWAY NEAR MITERED ENDS AND DRIVEWAY APRON. THERE ARE AREAS ON THE LEFT SIDE PROPERTY LINE THAT WILL NEED TO BE FILLED IN, COMPACTED AND SODDED TO MATCH GRADE. IN THE REAR LEFT CORNER THERE IS A GOOD AMOUNT OF STANDING WATER IN AN AREA THAT APPEARS TO HAVE BEEN DISTURBED DURING CLEARING. I CALLED CM DAN AND ASKED HIM FOR ANY INFO AND LET HIM KNOW THAT UNLESS WE HAVE PHOTOS AND A COMMUNICATION TRAIL THAT THIS WAS EXISTING PRE CLEARING, THEY WOULD BE REQUIRED TO CORRECT THIS AREA TO AS GOOD OR BETTER CONDITION. HE INDICATED HE DID NOT KNOW BUT WOULD CONTACT THE NEIGHBOR TO FIND OUT INFORMATION REGARDING THIS. HE INDICATED THAT THEY WOULD FIX THIS AREA IF NEED BE. BASED ON THIS CONVERSATION AS A COURTESY I LET HIM KNOW THAT I WOULD PASS THE FIELD SURVEY AS NOTED WITH THE CAVEAT THAT THESE AREAS WILL NEED TO BE REPAIRED BEFORE A ROW FINAL PASSAGE. HE AGREED. PHOTOS FOR REFERENCE. Inspector Notes from Inspection 9463 9/12/24 ELEVATION SHOTS AGAINST STRUCTURE PROVIDED AS REQUIRED. ELEVATION SHOT IN SWALE AT CORNER REVISED TO INDICATE FLOW AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED THAT I WILL VERIFY ON FIELD SURVEY INSPECTION. __________________________________________________________________________________________________________________________ 9/10/2024 - PREVIOUS INSPECTION NOTES 9/10/24 YOU NEED TO PROVIDE ELEVATION SHOTS ON ALL CORNERS OF THE STUCTURE AND EVERY 20 FT ALONG IT. SO WE CAN DETERMINE IF IT MEETS BELOW FFE REQUIREMENTS. FRONT TWO CORNERS HAVE NO ELEVATION SHOTS. YOU ARE SHOWING YOU SWALE TO BE 5 TENTHS HIGHER (25.3) AT THE CORNER THAN THE PREVIOUS SHOT OF 24.8 UPSTREAM. THIS WILL IMPEDE DRAINAGE FLOW AND CAUSE WATER TO POOL IN THIS AREA. Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for woodframe structures. (H) Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT WITHIN SWALE PLAN DIAGRAM TOLERANCE. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9463 9/12/24 ELEVATION SHOTS AGAINST STRUCTURE PROVIDED AS REQUIRED. ELEVATION SHOT IN SWALE AT CORNER REVISED TO INDICATE FLOW AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED THAT I WILL VERIFY ON FIELD SURVEY INSPECTION. __________________________________________________________________________________________________________________________ 9/10/2024 - PREVIOUS INSPECTION NOTES 9/10/24 YOU NEED TO PROVIDE ELEVATION SHOTS ON ALL CORNERS OF THE STUCTURE AND EVERY 20 FT ALONG IT. SO WE CAN DETERMINE IF IT MEETS BELOW FFE REQUIREMENTS. FRONT TWO CORNERS HAVE NO ELEVATION SHOTS. YOU ARE SHOWING YOU SWALE TO BE 5 TENTHS HIGHER (25.3) AT THE CORNER THAN THE PREVIOUS SHOT OF 24.8 UPSTREAM. THIS WILL IMPEDE DRAINAGE FLOW AND CAUSE WATER TO POOL IN THIS AREA. Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for woodframe structures. (H) Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT WITHIN SWALE PLAN DIAGRAM TOLERANCE. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/12/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 9/12/24 ELEVATION SHOTS AGAINST STRUCTURE PROVIDED AS REQUIRED. ELEVATION SHOT IN SWALE AT CORNER REVISED TO INDICATE FLOW AT THE TIME OF THIS INSPECTION. APPROVING AS NOTED THAT I WILL VERIFY ON FIELD SURVEY INSPECTION. __________________________________________________________________________________________________________________________ 9/10/2024 - PREVIOUS INSPECTION NOTES 9/10/24 YOU NEED TO PROVIDE ELEVATION SHOTS ON ALL CORNERS OF THE STUCTURE AND EVERY 20 FT ALONG IT. SO WE CAN DETERMINE IF IT MEETS BELOW FFE REQUIREMENTS. FRONT TWO CORNERS HAVE NO ELEVATION SHOTS. YOU ARE SHOWING YOU SWALE TO BE 5 TENTHS HIGHER (25.3) AT THE CORNER THAN THE PREVIOUS SHOT OF 24.8 UPSTREAM. THIS WILL IMPEDE DRAINAGE FLOW AND CAUSE WATER TO POOL IN THIS AREA. Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for woodframe structures. (H) Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT WITHIN SWALE PLAN DIAGRAM TOLERANCE. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/10/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 9/10/24 YOU NEED TO PROVIDE ELEVATION SHOTS ON ALL CORNERS OF THE STUCTURE AND EVERY 20 FT ALONG IT. SO WE CAN DETERMINE IF IT MEETS BELOW FFE REQUIREMENTS. FRONT TWO CORNERS HAVE NO ELEVATION SHOTS. YOU ARE SHOWING YOU SWALE TO BE 5 TENTHS HIGHER (25.3) AT THE CORNER THAN THE PREVIOUS SHOT OF 24.8 UPSTREAM. THIS WILL IMPEDE DRAINAGE FLOW AND CAUSE WATER TO POOL IN THIS AREA. Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for woodframe structures. (H) Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. Inspector Notes from Inspection 9270 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT WITHIN SWALE PLAN DIAGRAM TOLERANCE. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| ELECTRIC - EARLY POWER | 08/23/2024 | APPROVED - AS NOTED | KSANDOE |
| Note: Release Power | |||
| FLOOR / WALL PENETRATION | 08/23/2024 | APPROVED | KSANDOE |
| GRAVITY SEWER TEST | 08/02/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| U - SEWER TIE IN | 08/02/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 07/30/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 7/30/24 BM WAS'NT MATCHING UP. SPOKE TO JEFF CREWS WHO INDICATED HE SPOKE WITH THE GRADER AND THAT THE BM HAD SOMEHOW BEEN DAMAGED. JEFF TOLD ME TO SET LEFT SIDE CENTER LINE 26.10 AS BM AND CONFIRM RIGHT SIDE (INTERSECTION) WAS 26.25 AS INDICATED IN HIS NOTES. RIGHT WAS 26.20. USING THE 26.10 AS MY BASE LINE, PIPE SHOT 24.40 to a 24.38. JEFF SAID THIS WAS ACCEPTABLE SO I AM GOING TO APPROVE THIS AS NOTED. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. | |||
| PEP TANK INSTALLATION REQUEST | 07/16/2024 | APPROVED | CBOWERMASTER |
| LATH/BRICK/ WATER BARRIER | 07/03/2024 | APPROVED | BTAYLOR |
| INSULATION | 07/03/2024 | APPROVED | BTAYLOR |
| ALL ROUGH | 06/28/2024 | APPROVED | BTAYLOR |
| ELECTRIC-TUG | 06/27/2024 | APPROVED | RMARTIN |
| ROOF VALLEY & METAL | 06/25/2024 | APPROVED | BTAYLOR |
| WALL SHEATHING | 06/20/2024 | APPROVED | BTAYLOR |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 06/20/2024 | APPROVED - AS NOTED | BTAYLOR |
| Note: 6-20-24 1. Silt fence needs to be replaced before next inspection. | |||
| FOUND SURVEY APPROVED (OFFICE) | 06/18/2024 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 06/05/2024 | APPROVED | BTAYLOR |
| MONOLITHIC SLAB | 05/28/2024 | APPROVED | BTAYLOR |
| PLUMBING 1ST ROUGH UNDERGROUND | 05/22/2024 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 04/25/2024 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 07/10/2024 | 07/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/10/2024 | 07/10/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 06/17/2024 | 06/18/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 06/17/2024 | 06/17/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 04/08/2024 | 04/09/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 04/05/2024 | 04/08/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Plans show unvented attic. Energy Calcs say vented. revise calcs | |||
| BLD | COMPLETE | 04/01/2024 | 04/02/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 12/22/2023 | 01/03/2024 |
| Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/22/2023 | 12/22/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/11/2023 | 12/11/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 12/11/2023 | 12/19/2023 |
| Note: Held By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM 1- Please add adjacent elevations to lot 4 at a 20-foot interval and a 10 foot offset. 2- Please confirm/clarify one existing elevation that shows 00 inside the property. | |||
| ZON | COMPLETE | 12/11/2023 | 12/11/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/01/2023 | 12/01/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/01/2023 | 12/01/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 12/01/2023 | 12/11/2023 |
| Note: Held By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM 1- Please add adjacent elevations to lot 4 at a 20-foot interval and revise the proposed elevations adjacent to lot 4 to ensure that they do not negatively affect it. 2- Please depict the proposed loation of the PEP tank. 3- Please revise one existing elevation that shows 00. | |||
| ZON | HOLD | 10/26/2023 | 10/26/2023 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Floor plan and site plan have been corrected so that the AC pad is on the right side. Now you must still have the landscape plan corrected to match. | |||
| ENGIN1 | HOLD | 10/26/2023 | 10/26/2023 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Site benchmark elevation disagrees with other site elevations by .6' | |||
| SW1 | COMPLETE | 10/26/2023 | 11/07/2023 |
| Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM | |||
| ZON | HOLD | 09/14/2023 | 09/14/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Floor plan: Shows the AC on the right of the house all other plans show the ac on the left of the home. Site plan ladscape and floor plan should match | |||
| ENGIN1 | HOLD | 09/14/2023 | 09/15/2023 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Site benchmark elevation disagrees with other site elevations by .6' | |||
| SW1 | HOLD | 09/14/2023 | 09/20/2023 |
| Note: Held By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM The subject lots drainage must not negatively impact any adjacent property. (B) Unless specifically stated the subject lot must drain from back to front or a portion may be drained to an adjacent City drainage feature. (B) WATER IN THE BACK YARD IS RUNNING INTO THE EMPTY LOT IN THE BACK. STORMWATER NEED TO RUN FROM THE BACK TO THE FRONT | |||
| BLD | COMPLETE | 09/14/2023 | 09/15/2023 |
| Note: Released By: JPI | |||
| ELEC | COMPLETE | 09/14/2023 | 09/15/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 08/25/2023 | 08/28/2023 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Site benchmark elevation disagrees with other site elevations by .6' Wrong survey was submitted on 8-18 | |||
| ENGIN1 | COMPLETE | 08/18/2023 | 08/18/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/18/2023 | 08/18/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Site plan submitted not for this address REPEAT COMMENT: window on right side of home is missing banding around the window | |||
| BLD | COMPLETE | 08/18/2023 | 08/19/2023 |
| Note: Released By: JPI | |||
| SW1 | HOLD | 08/18/2023 | 08/28/2023 |
| Note: Held By: FRANK SLADISH - - FSLADISH@PALMCOASTGOV.COM Must provide the actual proposed FFE of the structure not just a minimum on your site plan. | |||
| ENGIN1 | HOLD | 08/11/2023 | 08/11/2023 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Site benchmark elevation disagrees with other site elevations by .6' | |||
| BLD | HOLD | 07/24/2023 | 07/24/2023 |
| Note: Held By: JPI 1) Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet. | |||
| ZON | HOLD | 07/24/2023 | 07/24/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comment Elevation plan : window on Row side RS of home is missing banding around the window | |||
| ENGIN1 | COMPLETE | 07/24/2023 | 07/25/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Site benchmark elevation disagrees with other site elevations by .6' | |||
| SW1 | HOLD | 07/24/2023 | 07/31/2023 |
| Note: Held By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM Need more elevations off the rear patio demonstrating enough drainage away from the structure. | |||
| ELEC | COMPLETE | 07/24/2023 | 07/25/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 07/17/2023 | 07/17/2023 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Site benchmark elevation disagrees with other site elevations by .6' | |||
| BLD | HOLD | 07/07/2023 | 07/07/2023 |
| Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet. | |||
| CUSVC | COMPLETE | 07/07/2023 | 07/10/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/07/2023 | 07/11/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/07/2023 | 07/07/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 07/07/2023 | 07/10/2023 |
| LOCATE | COMPLETE | 07/07/2023 | 07/11/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/07/2023 | 07/11/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 07/07/2023 | 07/17/2023 |
| Note: Held By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM Must have an accepted sight plan to review. | |||
| ZON | HOLD | 07/07/2023 | 07/11/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Site plan: please add material of walkway Elevation plan : window on Row side RS of home is missing banding around the window | |||
| BADMIN | COMPLETE | 07/07/2023 | 07/11/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 07/07/2023 | 12/11/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 09/25/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 09/25/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 09/25/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 09/25/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 02/06/2024 |
| CONNECTION FEES | ¤1,166.26 | 02/06/2024 |
| WATER- TURN ON | ¤25.00 | 02/06/2024 |
| ADJUSTMENT 50% | (¤512.73) | 02/06/2024 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 02/06/2024 |
| INSPECTION - RESIDENTIAL | ¤775.50 | 02/06/2024 |
| PLAN REVIEW - RESIDENTIAL | ¤219.96 | 02/06/2024 |
| FC IMPACT FEE EMS | ¤62.00 | 02/06/2024 |
| IMPACT FEE FIRE | ¤420.52 | 02/06/2024 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 02/06/2024 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 02/06/2024 |
| IMPACT FEE PARKS | ¤1,769.15 | 02/06/2024 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 02/06/2024 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 02/06/2024 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 02/06/2024 |
| SURCHARGE FS 533.721 | ¤5.13 | 02/06/2024 |
| SURCHARGE - FS 468.631 | ¤7.69 | 02/06/2024 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 02/06/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 02/06/2024 |
| SW ENG PRE APRON | ¤30.00 | 02/06/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 02/06/2024 |
| SW ENG RES REVIEW 200 | ¤200.00 | 02/06/2024 |
| SEWER CREDIT | (¤1,342.00) | 02/06/2024 |
| SEWER INSPECTION | ¤25.00 | 02/06/2024 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 02/06/2024 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 02/06/2024 |
| SITE PLAN 30 | ¤30.00 | 02/06/2024 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,185.68 |