Permit #2023070255
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-1090-000C0-2010 |
| Block: 000C0 |
| Subdivision: 1228 - SOUTHWEST QUADRANT |
| Job Phone: 229-375-9123 |
| Location Address: 160 CYPRESS POINT PKWY BLDG C |
| Type: CIA - COMMERCIAL INTERIOR EXTERIOR ALTERATION |
| Issue Date: 09/21/2023 |
| NOC: RECORDED |
| Applicant name: WILLIAM ROBERT BARRICK |
| Owner: 1ST GLOBAL REALTY LLC |
|
Address 160 CYPRESS POINT PKWY C212 PALM COAST, FL 32164 |
| Lot: 2010 |
| Contracted Stated Job Value: ¤9,500.00 |
| Job Description: UNIT C201 - INTERIOR RENOVATION - COASTAL REALTY PROS |
| Type: CN |
Contractor
RBI HOMES
| Status | Location Address | State License Number | Phone |
| CANCEL |
21 CEDARWOOD CT PALM COAST, FL 32137 |
RB29003845 (Exp: 08/31/2025) | 386-585-4097 |
Sub Contractors
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
DAVID SCOTT MORRIS
| Status | Location Address | State License Number | Phone |
| INACTIVE |
63 LEIDEL DR PALM COAST, FL 32137 |
ER13015750 (Exp: 08/31/2026) | 386-569-7262 |
Inspection History
| Type | Request Date | Result | Inspector |
| U - UTILITY COMMERCIAL FINAL | 12/11/2023 | FINAL APPROVED | LFITZGERALD |
| BUILDING FINAL | 12/07/2023 | Disapproved - NO FEE | FWILLIS |
| Note: NOT READY FOR FINAL. FIRE EXTINGUISHERS NOT MOUNTED. FRONT DOOR MOULDING ON THE SADDLE IS A TRIP HAZARD. FRONT DOOR CLOSING TO RAPIDLY AND LEAKING FLUID..... ADA SINGNAGE MISSING..... INSPECTION STOPPED......... | |||
| BUILDING FINAL | 12/07/2023 | FINAL APPROVED | FWILLIS |
| Note: 12/7/23 - ITEMS CORRECTED. 12/7/2023 - PREVIOUS INSPECTION NOTES NOT READY FOR FINAL. FIRE EXTINGUISHERS NOT MOUNTED. FRONT DOOR MOULDING ON THE SADDLE IS A TRIP HAZARD. FRONT DOOR CLOSING TO RAPIDLY AND LEAKING FLUID..... ADA SINGNAGE MISSING..... INSPECTION STOPPED......... | |||
| FIRE FINAL | 12/07/2023 | APPROVED | RMARTIN |
| ELECTRIC FINAL | 12/07/2023 | APPROVED | RMARTIN |
| Note: 12/5/2023 - PREVIOUS INSPECTION NOTES Picture needs to be moved from covering electrical panel, outlets in cove are not working check ALL, bath fan missing trim | |||
| HVAC FINAL | 12/05/2023 | FINAL APPROVED | CPISCITELLI |
| PLUMBING FINAL | 12/05/2023 | FINAL APPROVED | JWALKER |
| Note: Inspector Notes from Inspection 3080 THE ONLY THING BEING DONE IS SWITCHING W/C, LAV. LIKE FOR LIKE | |||
| ELECTRIC FINAL | 12/05/2023 | Disapproved - NO FEE | RMARTIN |
| Note: Picture needs to be moved from covering electrical panel, outlets in cove are not working check ALL, bath fan missing trim | |||
| FIREWALL FINAL | 12/05/2023 | APPROVED | FWILLIS |
| ABOVE CEILING | 11/21/2023 | Disapproved - NO FEE | RMARTIN |
| Note: 11/21/23 NEED TO HAVE HVAC CONTRACTOR LISTED, NEED TO HAVE RETURN DUCT MASTICED AND STRAPPED, NEED TO GET APPROVED REVISION FOR RETURN DUCT, 11/7/2023 - PREVIOUS INSPECTION NOTES MC CABLE HANGING OUT OF CEILING, NEED TO DOUBLE CHECK A FEW AREAS WHERE MC CABLE IS HANGING ON GRID NOT SUPPORTED | |||
| ABOVE CEILING | 11/21/2023 | APPROVED | RMARTIN |
| Note: 11/7/2023 - PREVIOUS INSPECTION NOTES MC CABLE HANGING OUT OF CEILING, NEED TO DOUBLE CHECK A FEW AREAS WHERE MC CABLE IS HANGING ON GRID NOT SUPPORTED | |||
| ABOVE CEILING | 11/07/2023 | Disapproved - NO FEE | RMARTIN |
| Note: MC CABLE HANGING OUT OF CEILING, NEED TO DOUBLE CHECK A FEW AREAS WHERE MC CABLE IS HANGING ON GRID NOT SUPPORTED | |||
| INSULATION | 11/02/2023 | Disapproved - NO FEE | FWILLIS |
| Note: NO INSULATION INSTALLED. | |||
| HVAC ROUGH | 11/02/2023 | APPROVED - AS NOTED | CPISCITELLI |
| Note: Need to check for balancing dampers and fresh air connection on the above ceiling inspection. Need revision before final for change in fresh air | |||
| FRAMING | 11/02/2023 | APPROVED | FWILLIS |
| HVAC ROUGH | 10/27/2023 | PARTIALLY APPROVED | CPISCITELLI |
| Note: 1. Need balancing dampers in supply outlets 2. Need to strap juction boxes 3. Fresh air calls for 2- 7inch lines. 4. Need approved mechanical plans onsite for inspection | |||
| PLUMBING 2ND ROUGH | 10/24/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THE ONLY THING BEING DONE IS SWITCHING W/C, LAV. LIKE FOR LIKE | |||
| ELECTRIC 2ND ROUGH | 10/17/2023 | APPROVED | RMARTIN |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 12/05/2023 | 12/05/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| FI1 | COMPLETE | 09/15/2023 | 09/15/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/15/2023 | 09/19/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| PLUM | COMPLETE | 09/15/2023 | 09/19/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/31/2023 | 08/31/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM COMMENTS BELOW PER THE 2020 FLORIDA BUILDING CODE-BUILDING, FLORIDA BUILDING CODE-EXISTING BUILDING AND FLORIDA BUILDING CODE-ACCESSIBILITY COMMENTS NO. 3 THROUGH 8 ADDED BY BUILDING OFFICIAL AFTER INITIAL REVIEW HOLD. ADDED TO PREVIOUS REVIEW HOLD AFTER REVIEW BY 1. Provide code analysis showing level of alteration per Chapter 6 of FBC Existing Building 2020 7th edition. Provide additional analysis per chapter 6 and identify any other required alterations. 2. Provide analysis with emphasis on accessibility 202.3 per FBC Accessibility 2020 7Th edition 3. Provide index of plan sheets on cover sheet. We have plan sheets 1.0, 4.0 and 7.0. 4.0 was not signed and sealed on the first submittal and has not been revised and re-uploaded. Where are plan sheets, 2.0, 3.0, 4.0, 5.0 and 6.0? If they do not exist then rename plan sheets on resubmittal. Match them with the engineer’s plan sheet naming convention. 4. Building is classified as Type IIB construction. Remove references to wood framed walls wood framing not allowed in IIB construction. Replace with non-combustible framing or fire-retardant wood framing. FBC Section 602.2, 603. 5. Door from bathroom that opens into hall is in violation of FBC-Building Section 1005.7. Doors in fully open position cannot reduce egress width (36 inches) by more than 7 inches. Doors in any position cannot reduce egress width by more than one-half 6. Door from hallway into front entry area (from hall side of door) does not meet clearances extending beyond latch side for forward approach, pull side of door. FBC-Accessibility 404.2.4.1 7. Door from office No. 1 to hall does not meet clearances extending beyond latch side of door for forward approach, pull side of door. FBC-Accessibility 404.2.4.1 8. Sink in break area must be accessible. Provide detail showing knee and toe clearance, counter top height, reach ranges, faucet type (no turning of the wrist) etc. FBC-Accessibility 306, 606. | |||
| FI1 | HOLD | 08/17/2023 | 08/28/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide Emergency Exit Sign in main hallway across from bathroom. 2. Provide Emergency Exit Sign in main hallway that can be seen when you step outside of bullpens. | |||
| ELEC | COMPLETE | 08/17/2023 | 08/22/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/17/2023 | 08/28/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| PLUM | HOLD | 08/17/2023 | 08/31/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM Engineer to define alteration level per the 2020 FBC-Existing Building and determine if any additional alterations are required as a result of the alteration level and whether any alterations are requried to existing bathrooms / plumbing fixtures. Plumbing review will not be marked complete until this item is resolved. | |||
| BLD | HOLD | 08/17/2023 | 08/31/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide code analysis showing level of alteration per Chapter 6 of FBC Existing Building 2020 &th edition. Provide additional analysis per chapter 6 and identify any other required alterations. 2. Provide analysis with emphasis on accessibility 202.3 per FBC Accessibility 2020 7Th edition | |||
| BLD | HOLD | 07/07/2023 | 07/20/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM 1. Permit application indicates proposed work is to add a bathroom. Submitted plans indicates an interior tenant build out. Please reconcile permit application and plans. 2. Plans are for commercial work and shall be signed and sealed by a Florida licensed architect and Florida professional engineer for any engineering design. If this is a tenant build out plans are extremely deficient. 3. No plan review performed. | |||
| DSD | COMPLETE | 07/07/2023 | 07/11/2023 |
| Note: Released By: JACQUELINE GONZALEZ - (386)986-3751 - JGONZALEZ@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 07/07/2023 | 07/17/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1.. Application is for added bathroom. Revise application to show interior build out. Where is the added bathroom? 2. Need to submit a lighting plan | |||
| FI1 | HOLD | 07/07/2023 | 07/12/2023 |
| Note: Held By: LEE MILLER - (386)986-3783 - WMILLER@PALMCOASTGOV.COM Please provide a written response to each comment below in a response letter and provide clouded response changes on plan sheets and add page locations for each response. 1. The application is for addition of a bathroom only, need to alter the permit to show commercial interior build out. 2. Please provide code analysis for a level 2 alteration for review including FBC Existing 7th edition, and FFPC 7th edition (2020) 3. Please provide life safety plan and clearly indicate the location of fire extinguishers, travel distance to extinguishers, travel distance to exits from the most remote location, exit signs in location such that the way to an exit is clearly identified from the exit of any office/room per FFPC I Fire Code 10.14.3.4.3 Additional comments are likely after resubmittal. | |||
| MECH | HOLD | 07/07/2023 | 07/17/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Provide code analysis showing level of alteration per Chapter 6 of FBC Existing Building and Chapter 3 FBC Building. 2. Application is for added bathroom. Revise application to show interior build out. Where is the added bathroom? 3. Provide Heatload Calculation per C403.2.1 FBC Energy Conservation 2020 7Th edition 4. Provide existing duct layout showing supply, return, fresh air and exhaust with proposed changes per 107.2.1 FBC Building 2020 7Th edition | |||
| PLUM | HOLD | 07/07/2023 | 07/20/2023 |
| Note: Held By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM 1. Permit application indicates proposed work is to add a bathroom. Submitted plans indicates an interior tenant build out. Please reconcile permit application and plans. 2. Plans are for commercial work and shall be signed and sealed by a Florida licensed architect and Florida professional engineer for any engineering design. If this is a tenant build out plans are extremely deficient. 3. No plan review performed. | |||
| UD1 | COMPLETE | 07/07/2023 | 07/10/2023 |
| Note: Released By: BRICE WRIGHT - (386)986-2398 - BWRIGHT@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 12/08/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 09/21/2023 |
| SURCHARGE - FS 468.631 | ¤2.00 | 09/21/2023 |
| SITE PLAN 30 | ¤30.00 | 09/21/2023 |
| ADJUSTMENT 50% | (¤105.00) | 09/21/2023 |
| ADMINISTRATIVE - COMMERCIAL | ¤75.00 | 09/21/2023 |
| INSPECTION COMMERCIAL | ¤70.00 | 09/21/2023 |
| PLAN REVIEW - COMMERCIAL | ¤65.00 | 09/21/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤159.00 |