I want to search for...

Permit #2023070295

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00620-0040
CONDITIONED SPACE: 2274 sqft
GARAGE: 494 sqft
OPENED PORCH (WITH ROOF) : 212 sqft
Total Square Footage: 2980 sqft
Block: 00620
Subdivision: 2155 - SECTION 32-ROYAL PALMS
Job Phone: 229-375-9123
Location Address: 24 ROCKING LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 07/25/2023
NOC: RECORDED
Applicant name: WILLIAM ROBERT BARRICK
Owner: JMR III

Address

10 WHITTINGTON DR

PALM COAST, FL 32164

Lot: 0040
Contracted Stated Job Value: ¤313,812.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

RBI HOMES
Status Location Address State License Number Phone
CANCEL

21 CEDARWOOD CT

PALM COAST, FL 32137

RB29003845 (Exp: 08/31/2025) 386-585-4097

Sub Contractors

JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
DAVID SCOTT MORRIS
Status Location Address State License Number Phone
INACTIVE

63 LEIDEL DR

PALM COAST, FL 32137

ER13015750 (Exp: 08/31/2026) 386-569-7262
WILLIAM ROBERT BARRICK
Status Location Address Mailing Address State License Number Phone
CANCEL

50 LEANNI WAY

PALM COAST, FL 32137

STE E2

PALM COAST, FL 32137

RC29027799 (Exp: 08/31/2025) 229-375-9123
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

PO BOX 912

PALM COAST, FL 32164

CAC1820539 (Exp: 08/31/2026) 386-264-0550

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/09/2024 FINAL APPROVED AGAETANO
Note: 5/8/2024 - PREVIOUS INSPECTION NOTES 05-08-2024 1. Multiple outlets loose. Check all. 2. Lanai outlets need waterproof covers.
BLD - BUILDING FINAL 05/08/2024 Disapproved - NO FEE AGAETANO
Note: 05-08-2024 1. Multiple outlets loose. Check all. 2. Lanai outlets need waterproof covers.
ROW - FINAL APRON (AFTER POUR) 05/03/2024 APPROVED TPOLACEK
Note: *** NOTES ADDED BY TPOLACEK 5/3/2024 9:29:03 AM *** PIPE IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW - STORMWATER FINAL 05/03/2024 APPROVED TPOLACEK
Note: *** NOTES ADDED BY TPOLACEK 5/3/2024 9:29:34 AM *** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
U -UTILITY RESIDENTIAL FINAL 05/03/2024 FINAL APPROVED DHANEY
Note: Inspector Notes from Inspection 9035 has potable irrigation with PVB-no cross connection
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/01/2024 APPROVED TPOLACEK
ROW FIELD SURVEY /GRADING CERTIFICATION 05/01/2024 APPROVED TPOLACEK
Note: 05/01/24 BUILDER CREATED THE REQUESTED DRAINAGE SYSTEM IN THE BACK YARD. DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY.AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THE BUILDER NEEDS TO SUBMIT A NEW SITE PLAN. ADDITIONALLY, THEY NEED TO CREATE A DRAINAGE SYSTEM THAT GOES FROM THE BACK TO THE FRONT BY MAKING A SWALE AROUND THE PROPERTY THAT IS AT LEAST 3/10 LOWER THAN THE PROPERTY LINE.PER GBERTOLA
U-CROSS CONNECTION 05/01/2024 APPROVED - AS NOTED LFITZGERALD
Note: has potable irrigation with PVB-no cross connection
ROW- PRE-APRON (PRE-POUR) 04/24/2024 APPROVED TPOLACEK
Note: AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW- PROJECT STATUS 04/18/2024 APPROVED GBERTOLA
Note: 4/18/24= meeting with the builder
ROW- PROJECT STATUS 03/27/2024 APPROVED GBERTOLA
Note: THE BUILDER NEEDS TO SUBMIT A NEW SITE PLAN. ADDITIONALLY, THEY NEED TO CREATE A DRAINAGE SYSTEM THAT GOES FROM THE BACK TO THE FRONT BY MAKING A SWALE AROUND THE PROPERTY THAT IS AT LEAST 3/10 LOWER THAN THE PROPERTY LINE.per gbertola
ELECTRIC - EARLY POWER 03/12/2024 APPROVED JWALKER
Note: 3/11/2024 - PREVIOUS INSPECTION NOTES Master toilet room missing double switch cover.
ELECTRIC - EARLY POWER 03/11/2024 Disapproved - NO FEE JWALKER
Note: Master toilet room missing double switch cover.
GRAVITY SEWER TEST 02/14/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 02/14/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
LATH/BRICK/ WATER BARRIER 01/10/2024 APPROVED JWALKER
Note: 1/8/2024 - PREVIOUS INSPECTION NOTES Wire mesh will need to be installed over the exposed zip tape around the windows. Zip tape is not an approved base for plaster.
INSULATION 01/09/2024 APPROVED JWALKER
Note: 1/8/2024 - PREVIOUS INSPECTION NOTES 1/8/24 The below listed corrections from the all rough inspection have not been completed. 1. The HVAC distribution box above the kitchen area is missing supports. 2. Microwave exhaust duct. Seal all mechanical joints and install nail plates front and rear at the 2x4 wall top plate. 3. Missing nail plates for wire above the den / study window at the top chord. Check for corrections at the Insulation inspection.
INSULATION 01/08/2024 Disapproved - NO FEE JWALKER
Note: 1/8/24 The below listed corrections from the all rough inspection have not been completed. 1. The HVAC distribution box above the kitchen area is missing supports. 2. Microwave exhaust duct. Seal all mechanical joints and install nail plates front and rear at the 2x4 wall top plate. 3. Missing nail plates for wire above the den / study window at the top chord. Check for corrections at the Insulation inspection.
LATH/BRICK/ WATER BARRIER 01/08/2024 Disapproved - NO FEE JWALKER
Note: Wire mesh will need to be installed over the exposed zip tape around the windows. Zip tape is not an approved base for plaster.
ALL ROUGH 01/04/2024 APPROVED - AS NOTED JWALKER
Note: 1. The HVAC distribution box above the kitchen area is missing supports. 2. Microwave exhaust duct. Seal all mechanical joints and install nail plates front and rear at the 2x4 wall top plate. 3. Missing nail plates for wire above the den / study window at the top chord. Check for corrections at the Insulation inspection.
ELECTRIC TEMP POLE 12/28/2023 APPROVED JWALKER
Note: 12/22/2023 - PREVIOUS INSPECTION NOTES Cross bacing 2x's have not been supported at the bases. Common practice is to drive stake's into the ground and nail the cross braces to the stake's. 12/21/2023 - PREVIOUS INSPECTION NOTES Post needs to be cross braced both ways.
ELECTRIC TEMP POLE 12/22/2023 Disapproved - NO FEE JWALKER
Note: Cross bacing 2x's have not been supported at the bases. Common practice is to drive stake's into the ground and nail the cross braces to the stake's. 12/21/2023 - PREVIOUS INSPECTION NOTES Post needs to be cross braced both ways.
ROW - DRAINAGE 12/22/2023 APPROVED TPOLACEK
Note: 12/22/23 CORRECTION WERE MADE AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ___________________________________________________________________________________________ 12/15/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE THE PORTER JOHN OUT OF RIGHT OF WAY AND PUT IT ON YOUR LOT 2) NEED TO PUT A SILT FENCE AROUND THE ENTIRE CONSTRUCTION SITE AND LEAVE AN ENTRANCE TO YOUR LOT THE SILT FENCE ALONG THE RIGHT OF WAY WILL ALLOW NO SEDIMENT TO WASH IN THE ROADSIDE SWALE ANY MORE 3) NEED TO LEAVE THE ROADSIDE SWALE OPEN AT ALL TIMES DURING CONSTRCTION OR PUT AN TEMP. CULVERT SO WATER WILL FLOW TO OUTFALL 4) NEED TO CLEAN ALL SEDIMENT OUT OF ADJACENT LOTS ROADSIDE SWALE NEXT INSPECTION ON 12/22/23. YOU WILL HAVE 7 BUSINESS DAY TO FIX ALL AREAS ABOVE OR THERE WILL BE AN INSPECTION HOLD ON THIS CONSTRCTION SITE.
ELECTRIC TEMP POLE 12/21/2023 Disapproved - NO FEE JWALKER
Note: Post needs to be cross braced both ways.
ROW - DRAINAGE 12/15/2023 Disapproved - NO FEE PFLANAGAN
Note: 1) NEED TO REMOVE THE PORTER JOHN OUT OF RIGHT OF WAY AND PUT IT ON YOUR LOT 2) NEED TO PUT A SILT FENCE AROUND THE ENTIRE CONSTRUCTION SITE AND LEAVE AN ENTRANCE TO YOUR LOT THE SILT FENCE ALONG THE RIGHT OF WAY WILL ALLOW NO SEDIMENT TO WASH IN THE ROADSIDE SWALE ANY MORE 3) NEED TO LEAVE THE ROADSIDE SWALE OPEN AT ALL TIMES DURING CONSTRCTION OR PUT AN TEMP. CULVERT SO WATER WILL FLOW TO OUTFALL 4) NEED TO CLEAN ALL SEDIMENT OUT OF ADJACENT LOTS ROADSIDE SWALE NEXT INSPECTION ON 12/22/23. YOU WILL HAVE 7 BUSINESS DAY TO FIX ALL AREAS ABOVE OR THERE WILL BE AN INSPECTION HOLD ON THIS CONSTRCTION SITE.
ROOF VALLEY & METAL 12/05/2023 APPROVED JWALKER
Note: 11/29/2023 - PREVIOUS INSPECTION NOTES 11/29/23 Peel and stick or metal is required in valleys 11/17/23 Items 2 and 4 listed below need to be corrected prior to all rough inspection. 11/15/2023 - PREVIOUS INSPECTION NOTES 1. Please have a full set of approved drawings in order onsited for reinspection. 2. Front entry framing and truss connections are concealed by sheating. All sheating does Not need to be removed. Just remove enough to unconceal. 3. The HTS20 anchor at the garage bearing wall needs to attach to the PLS post below. Wrapping around the top plate is not the correct application. 4. Rear bearing wall missing the CS stapping at the 2x8 header. 5. Install the L-50 anchor at the overframing. See over framing detail. 6. Truss T-14 is missing a hold down anchor at the inner CMU wall.
ROOF VALLEY & METAL 11/29/2023 Disapproved - NO FEE MKRASKI
Note: 11/29/23 Peel and stick or metal is required in valleys 11/17/23 Items 2 and 4 listed below need to be corrected prior to all rough inspection. 11/15/2023 - PREVIOUS INSPECTION NOTES 1. Please have a full set of approved drawings in order onsited for reinspection. 2. Front entry framing and truss connections are concealed by sheating. All sheating does Not need to be removed. Just remove enough to unconceal. 3. The HTS20 anchor at the garage bearing wall needs to attach to the PLS post below. Wrapping around the top plate is not the correct application. 4. Rear bearing wall missing the CS stapping at the 2x8 header. 5. Install the L-50 anchor at the overframing. See over framing detail. 6. Truss T-14 is missing a hold down anchor at the inner CMU wall.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/17/2023 APPROVED - AS NOTED JWALKER
Note: 11/17/23 Items 2 and 4 listed below need to be corrected prior to all rough inspection. 11/15/2023 - PREVIOUS INSPECTION NOTES 1. Please have a full set of approved drawings in order onsited for reinspection. 2. Front entry framing and truss connections are concealed by sheating. All sheating does Not need to be removed. Just remove enough to unconceal. 3. The HTS20 anchor at the garage bearing wall needs to attach to the PLS post below. Wrapping around the top plate is not the correct application. 4. Rear bearing wall missing the CS stapping at the 2x8 header. 5. Install the L-50 anchor at the overframing. See over framing detail. 6. Truss T-14 is missing a hold down anchor at the inner CMU wall.
WALL SHEATHING 11/15/2023 APPROVED JWALKER
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/15/2023 Disapproved - NO FEE JWALKER
Note: 1. Please have a full set of approved drawings in order onsited for reinspection. 2. Front entry framing and truss connections are concealed by sheating. All sheating does Not need to be removed. Just remove enough to unconceal. 3. The HTS20 anchor at the garage bearing wall needs to attach to the PLS post below. Wrapping around the top plate is not the correct application. 4. Rear bearing wall missing the CS stapping at the 2x8 header. 5. Install the L-50 anchor at the overframing. See over framing detail. 6. Truss T-14 is missing a hold down anchor at the inner CMU wall.
FOUND SURVEY APPROVED (OFFICE) 10/05/2023 APPROVED TBAKER
TIE BEAM / LINTEL 09/26/2023 APPROVED KSANDOE
Note: 9/25/2023 - PREVIOUS INSPECTION NOTES 1. Lintel 9 at the garage calls for to #5 rebar to be installed at the bottom. Only 1 installed. 2. Lintel (6) at the rear lanai slider opening calls for 2 at the top and 2 at the bottom reinforcing bars. Only 1 installed top and bottom. 3. Rear lanai lintel not numbered also calls for 2 top and 2 bottom only 1 installed. See page 4.0FF of the prints. 4. Lintel (2) at the front entry 2 top and 2 bottom. 5. The precast window sills have not been installed.
TIE BEAM / LINTEL 09/25/2023 Disapproved - NO FEE JWALKER
Note: 1. Lintel 9 at the garage calls for to #5 rebar to be installed at the bottom. Only 1 installed. 2. Lintel (6) at the rear lanai slider opening calls for 2 at the top and 2 at the bottom reinforcing bars. Only 1 installed top and bottom. 3. Rear lanai lintel not numbered also calls for 2 top and 2 bottom only 1 installed. See page 4.0FF of the prints. 4. Lintel (2) at the front entry 2 top and 2 bottom. 5. The precast window sills have not been installed.
MONOLITHIC SLAB 09/13/2023 APPROVED JWALKER
PLUMBING 1ST ROUGH UNDERGROUND 09/01/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 08/18/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BADMIN INFORMATION 04/08/2024 04/08/2024
Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM For future submittals, please include a description of what the change/revision is. Site plans are not reviewed by the Building Staff, boxes identifed should be one of these, zoning, stormwater or engineering.
SW1 COMPLETE 04/08/2024 04/15/2024
Note: Released By: SINA VEDADI MOGHADAM - (386)986-2569 - SVEDADIMOGHADAM@PALMCOASTGOV.COM
ZON COMPLETE 04/08/2024 04/08/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 04/04/2024 04/08/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 01/31/2024 02/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 01/31/2024 02/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 01/02/2024 01/02/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 01/02/2024 01/02/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 11/14/2023 11/16/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/04/2023 10/05/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 10/04/2023 10/04/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/21/2023 08/22/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 08/21/2023 08/28/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 08/21/2023 08/21/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 08/15/2023 08/21/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 07/19/2023 07/24/2023
Note: Released By: JPI
SWALE COMPLETE 07/11/2023 08/15/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 07/10/2023 07/16/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
CUSVC COMPLETE 07/10/2023 07/11/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 07/10/2023 07/11/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/10/2023 07/11/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 07/10/2023 07/10/2023
LOCATE COMPLETE 07/10/2023 07/11/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 07/10/2023 07/12/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 07/10/2023 07/18/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON COMPLETE 07/10/2023 07/11/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BADMIN COMPLETE 07/10/2023 07/17/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 05/08/2024
CONTRACTOR CHANGE ¤20.00 05/08/2024
SW ENG - INSPECTION 20 ¤20.00 05/08/2024
SW ENG - INSPECTION 20 ¤20.00 05/08/2024
SW ENG REINSPECTION 20 ¤20.00 05/08/2024
SW ENG REINSPECTION 20 ¤20.00 05/08/2024
PLAN REVIEW - REVISION ¤32.50 05/08/2024
CONNECTION FEES ¤1,166.26 07/25/2023
SW ENG - REVIEW 20 ¤20.00 07/25/2023
SW ENG RES REVIEW 200 ¤200.00 07/25/2023
TRANS IMPACT FEE ADMIN ¤54.36 07/25/2023
TRANS IMPACT FEE ADMIN (¤54.36) 07/25/2023
SEWER CREDIT (¤1,147.00) 07/25/2023
SEWER INSPECTION ¤25.00 07/25/2023
SEWER CAPITAL FACILITY ¤5,344.82 07/25/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 07/25/2023
SITE PLAN 30 ¤30.00 07/25/2023
SW ENG INSPECTION 80 ¤80.00 07/25/2023
SW ENG PRE APRON ¤30.00 07/25/2023
WATER-METER ¤505.39 07/25/2023
WATER- TURN ON ¤25.00 07/25/2023
WATER- TURN ON ¤25.00 07/25/2023
ADJUSTMENT 50% (¤569.21) 07/25/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 07/25/2023
INSPECTION - RESIDENTIAL ¤863.50 07/25/2023
PLAN REVIEW - RESIDENTIAL ¤244.92 07/25/2023
FIRE IMPACT FEE ADMIN ¤12.62 07/25/2023
FIRE IMPACT FEE ADMIN (¤12.62) 07/25/2023
FC IMPACT FEE EMS ¤62.00 07/25/2023
IMPACT FEE FIRE ¤420.52 07/25/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 07/25/2023
FC IMPACT FEE LIBRARY ¤268.00 07/25/2023
IMPACT FEE PARKS ¤1,769.15 07/25/2023
IMPACT FEE SCHOOL ¤5,450.00 07/25/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 07/25/2023
WATER -IRRIGATION INSPECTION ¤25.00 07/25/2023
WATER -IRRIGATION INSPECTION ¤25.00 07/25/2023
PARKS IMPACT FEE ADMIN ¤53.07 07/25/2023
PARKS IMPACT FEE ADMIN (¤53.07) 07/25/2023
SURCHARGE FS 533.721 ¤5.69 07/25/2023
SURCHARGE - FS 468.631 ¤8.54 07/25/2023
SW ENG - FOUNDATION SURVEY ¤20.00 07/25/2023
Fees Total Due: ¤0.00 Total Paid: ¤21,033.96