I want to search for...

Permit #2023070304

Permit Details

Status: COED

Parcel Id: 07-11-31-7026-00650-0380
CONDITIONED SPACE: 1500 sqft
GARAGE: 396 sqft
OPENED PORCH (WITH ROOF) : 100 sqft
OPENED PORCH (WITH ROOF) : 12 sqft
Total Square Footage: 2008 sqft
Block: 00650
Subdivision: 2153 - SECTION 26-PINE GROVE
Job Phone: 202-494-2019
Location Address: 33 PINWHEEL LN
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/07/2023
NOC: RECORDED
Applicant name: GARY ANDREW FISCHER
Owner: INB FUND 2 LLC

Address

3670 MAGUIRE BOULEVARD SUITE 220

ORLANDO, FL 32803

Lot: 0380
Contracted Stated Job Value: ¤150,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INB HOMES
Status Location Address Mailing Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD

ORLANDO, FL 32803

SUITE 210

ORLANDO, FL 32803

CGC048746 (Exp: 08/31/2026) 407-476-8195

Sub Contractors

ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 01/29/2024 APPROVED - AS NOTED FSLADISH
Note: 1/29/24 DRIVEWAY APRON WING REPAIRED AS REQUIRED. PIPE GOOD. CUTS MADE. HOT PATCH COMPLETED. CULVERT CLEAR. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ______________________________________________________________________________________________________________________ 1/26/2024 - PREVIOUS INSPECTION NOTES 1/24/26 PLEASE READ PREVIOUS INSPECTION NOTES. YOU NEED TO REPAIR LEFT SIDE DRIVEWAY APRON FLAIR CRACK PHOTO FOR REFERENCE. 1/24/2024 - PREVIOUS INSPECTION NOTES 1/24/24 DRIVEWAY APRON CRACK NOT REPAIRED AT THE TIME OF THIS INSPECTION AS NOTED PREVIOUSLY. PLEAS MAKE REQUIRED REPAIR BEFORE RESUBMITTING FOR AFTERPOUR INSPECTION. PHOTO ENCLOSED FOR REFERENCE. ____________________________________________________________________________________________________________________________ NEED TO FIX THE LEFT APRON FLAIR CRACK BEFORE PASSING AFTER POUR
BLD - BUILDING FINAL 01/26/2024 FINAL APPROVED RSIMS
Note: 1/24/2024 - PREVIOUS INSPECTION NOTES 1/24/24: 1). No hot water. (Also, Cold water supply valve to water heater is bad). 2). AHU: Installed unit model number does not match Energy Calcs. 3). Range: anti-tip device is not installed properly & therefore does no prevent tipping. 4). Garage door opener is not operating properly so safety eyes could not be tested. 5). Condensing unit does not have the required 3" ground clearance. M1305.1.4.1 6). Exterior GFCI below meter panel is not identified. NEC 408.4 (A) 7). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max off floor) 8). Master bathroom: Shower along curb & vanity along bottom are not sealed as required. FBC-P2705.1(3) 9). Washing Machine Box cover is missing. 10). Hall bath vanity is not sealed along the bottom as required. FBC-P2705.1(3) Where fixtures come in contact with walls and floors, the contact shall be water tight.
ROW - FINAL APRON (AFTER POUR) 01/26/2024 Disapproved -FEE REQUIRED FSLADISH
Note: 1/24/26 PLEASE READ PREVIOUS INSPECTION NOTES. YOU NEED TO REPAIR LEFT SIDE DRIVEWAY APRON FLAIR CRACK PHOTO FOR REFERENCE. 1/24/2024 - PREVIOUS INSPECTION NOTES 1/24/24 DRIVEWAY APRON CRACK NOT REPAIRED AT THE TIME OF THIS INSPECTION AS NOTED PREVIOUSLY. PLEAS MAKE REQUIRED REPAIR BEFORE RESUBMITTING FOR AFTERPOUR INSPECTION. PHOTO ENCLOSED FOR REFERENCE. ____________________________________________________________________________________________________________________________ NEED TO FIX THE LEFT APRON FLAIR CRACK BEFORE PASSING AFTER POUR
ROW - FINAL APRON (AFTER POUR) 01/24/2024 Disapproved -FEE REQUIRED FSLADISH
Note: 1/24/24 DRIVEWAY APRON CRACK NOT REPAIRED AT THE TIME OF THIS INSPECTION AS NOTED PREVIOUSLY. PLEAS MAKE REQUIRED REPAIR BEFORE RESUBMITTING FOR AFTERPOUR INSPECTION. PHOTO ENCLOSED FOR REFERENCE. ____________________________________________________________________________________________________________________________ NEED TO FIX THE LEFT APRON FLAIR CRACK BEFORE PASSING AFTER POUR
BLD - BUILDING FINAL 01/24/2024 Disapproved -FEE REQUIRED RSIMS
Note: 1/24/24: 1). No hot water. (Also, Cold water supply valve to water heater is bad). 2). AHU: Installed unit model number does not match Energy Calcs. 3). Range: anti-tip device is not installed properly & therefore does no prevent tipping. 4). Garage door opener is not operating properly so safety eyes could not be tested. 5). Condensing unit does not have the required 3" ground clearance. M1305.1.4.1 6). Exterior GFCI below meter panel is not identified. NEC 408.4 (A) 7). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max off floor) 8). Master bathroom: Shower along curb & vanity along bottom are not sealed as required. FBC-P2705.1(3) 9). Washing Machine Box cover is missing. 10). Hall bath vanity is not sealed along the bottom as required. FBC-P2705.1(3) Where fixtures come in contact with walls and floors, the contact shall be water tight.
U -UTILITY RESIDENTIAL FINAL 01/24/2024 APPROVED - AS NOTED LFITZGERALD
Note: Inspector Notes from Inspection 9035 pep tank alarmnot working-utility informed no irr-no cross connection
ROW FIELD SURVEY /GRADING CERTIFICATION 01/23/2024 APPROVED PFLANAGAN
Note: CORRECTION MADE ---------------------------------------------------------- 1/22/2024 - PREVIOUS INSPECTION NOTES PLEASE MAKE THE BERM BIGER SO IT WILL NOT WASH OUT ----------------------------------------------------------- 1/19/2024 - PREVIOUS INSPECTION NOTES NOT READY FOR INSPECTION ----------------------------------------------------------- 1/18/2024 - PREVIOUS INSPECTION NOTES THE BACK LEFT CORNER THE WATER IS IMPACTING THE LOT TO THE LEFT YOUR NEED TO FIX SO WATER WILL NOT IMPACT THAT AREA
ROW - STORMWATER FINAL 01/23/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
ROW FIELD SURVEY /GRADING CERTIFICATION 01/22/2024 Disapproved - NO FEE PFLANAGAN
Note: PLEASE MAKE THE BERM BIGER SO IT WILL NOT WASH OUT ----------------------------------------------------------- 1/19/2024 - PREVIOUS INSPECTION NOTES NOT READY FOR INSPECTION ----------------------------------------------------------- 1/18/2024 - PREVIOUS INSPECTION NOTES THE BACK LEFT CORNER THE WATER IS IMPACTING THE LOT TO THE LEFT YOUR NEED TO FIX SO WATER WILL NOT IMPACT THAT AREA
ROW FIELD SURVEY /GRADING CERTIFICATION 01/19/2024 CANCELLED BY APPLICANT PFLANAGAN
Note: NOT READY FOR INSPECTION ----------------------------------------------------------- 1/18/2024 - PREVIOUS INSPECTION NOTES THE BACK LEFT CORNER THE WATER IS IMPACTING THE LOT TO THE LEFT YOUR NEED TO FIX SO WATER WILL NOT IMPACT THAT AREA
ROW FIELD SURVEY /GRADING CERTIFICATION 01/18/2024 Disapproved - NO FEE PFLANAGAN
Note: THE BACK LEFT CORNER THE WATER IS IMPACTING THE LOT TO THE LEFT YOUR NEED TO FIX SO WATER WILL NOT IMPACT THAT AREA
U-CROSS CONNECTION 01/11/2024 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cross connection
ROW- FINAL SURVEY/GRADING CERTIFICATION 01/09/2024 APPROVED RGROSS
ELECTRIC - EARLY POWER 12/29/2023 APPROVED - AS NOTED BTAYLOR
Note: Inspector Notes from Inspection 2200 Emailed FPL @ 1105. Release Power 12-29-23 1. Emailed FPL at 12:36.
GRAVITY SEWER TEST 12/20/2023 APPROVED MGIBSON
U - SEWER TIE IN 12/20/2023 APPROVED MGIBSON
ROW- PRE-APRON (PRE-POUR) 12/15/2023 APPROVED GBERTOLA
Note: 12/15/23= AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR; THE BUILDER SHOULD DOUBLE-CHECK THE CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVERT DETAIL ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 12/14/2023 - PREVIOUS INSPECTION NOTES 1) THE MITER END FOOTERS NEED TO BE A MINIMUM OF 6"X6" SEE DIAGRAM Sec 300.E / 300.H 2) THERE ARE AREAS IN THE APRON THAT DONT GIVE YOU THE MINIMUM AMOUNT OF CONCRETE Sec.900.04A Driveway thickness on the right-of-way shall be either six inches (6") on firmly compacted subgrade of clean granular material.
ROW- PRE-APRON (PRE-POUR) 12/14/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) THE MITER END FOOTERS NEED TO BE A MINIMUM OF 6"X6" SEE DIAGRAM Sec 300.E / 300.H 2) THERE ARE AREAS IN THE APRON THAT DONT GIVE YOU THE MINIMUM AMOUNT OF CONCRETE Sec.900.04A Driveway thickness on the right-of-way shall be either six inches (6") on firmly compacted subgrade of clean granular material.
PEP TANK INSTALLATION REQUEST 11/22/2023 APPROVED CBOWERMASTER
INSULATION 11/15/2023 APPROVED KSANDOE
Note: 11/13/2023 - PREVIOUS INSPECTION NOTES 11/13/23: 1). Missing firestop at horizontal runs per FBC Required Locations FBC-302.11.1.2 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm). 2). Right side of garage along entire top plate/drywall nailer connection will require firestop since the top plate is above the garage ceiling. 3). Lineset sleeve is not sealed as required.
INSULATION 11/13/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/13/23: 1). Missing firestop at horizontal runs per FBC Required Locations FBC-302.11.1.2 1.2. Horizontally at intervals not exceeding 10 feet (3048 mm). 2). Right side of garage along entire top plate/drywall nailer connection will require firestop since the top plate is above the garage ceiling. 3). Lineset sleeve is not sealed as required.
LATH/BRICK/ WATER BARRIER 11/09/2023 APPROVED KSANDOE
ALL ROUGH 11/08/2023 APPROVED KSANDOE
Note: 11/7/2023 - PREVIOUS INSPECTION NOTES Need plans on site for inspection
ALL ROUGH 11/07/2023 Disapproved - NO FEE KSANDOE
Note: Need plans on site for inspection
ELECTRIC-TUG 11/07/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 1105. Release Power
ROOF VALLEY & METAL 10/24/2023 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2460 Clean up job site. Place all construction debris in dumpster
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/20/2023 APPROVED - AS NOTED KSANDOE
Note: Clean up job site. Place all construction debris in dumpster
ROOF SHEATHING 10/19/2023 APPROVED KSANDOE
WALL SHEATHING 10/19/2023 APPROVED KSANDOE
FOUND SURVEY APPROVED (OFFICE) 10/13/2023 APPROVED TBAKER
TIE BEAM / LINTEL 10/09/2023 APPROVED KSANDOE
MONOLITHIC SLAB 09/27/2023 APPROVED KSANDOE
PLUMBING 1ST ROUGH UNDERGROUND 09/26/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 09/05/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 01/25/2024 01/25/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/12/2023 10/13/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 10/12/2023 10/12/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 07/21/2023 07/24/2023
Note: Released By: JPI
ZON COMPLETE 07/19/2023 07/19/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD HOLD 07/19/2023 07/21/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. 25103.2 product approval has an applied for status on the DBPR website. Please provide a substitute.
BADMIN COMPLETE 07/19/2023 07/21/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 07/11/2023 08/16/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 07/10/2023 07/16/2023
Note: Held By: JPI 1. 25103.2 product approval has an applied for status on the DBPR website. Please provide a substitute. 2. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
CUSVC COMPLETE 07/10/2023 07/10/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 07/10/2023 07/11/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/10/2023 07/11/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 07/10/2023 07/10/2023
LOCATE COMPLETE 07/10/2023 07/11/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 07/10/2023 07/12/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 07/10/2023 07/18/2023
Note: Released By: FRANK SLADISH - - FSLADISH@PALMCOASTGOV.COM
ZON HOLD 07/10/2023 07/11/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM All windows and doors facing right of way must have banding placed around them.
BADMIN HOLD 07/10/2023 07/17/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. 25103.2 product approval has an applied for status on the DBPR website. Please provide a substitute. 2. Truss package is good.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
SW ENG REINSPECTION 20 ¤20.00 01/26/2024
SW ENG REINSPECTION 20 ¤20.00 01/25/2024
PLAN REVIEW - REVISION ¤32.50 01/25/2024
REINSPECTION RESIDENTIAL ¤40.00 01/25/2024
REINSPECTION RESIDENTIAL ¤40.00 01/23/2024
SW ENG REINSPECTION 30 ¤30.00 01/23/2024
SW ENG - REVIEW 20 ¤20.00 08/07/2023
SW ENG RES REVIEW 200 ¤200.00 08/07/2023
TRANS IMPACT FEE ADMIN ¤54.36 08/07/2023
TRANS IMPACT FEE ADMIN ¤54.36 08/07/2023
SEWER CREDIT (¤1,147.00) 08/07/2023
SEWER INSPECTION ¤25.00 08/07/2023
SEWER CAPITAL FACILITY ¤5,344.82 08/07/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 08/07/2023
SITE PLAN 30 ¤30.00 08/07/2023
WATER- TURN ON ¤25.00 08/07/2023
ADJUSTMENT 50% (¤345.06) 08/07/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/07/2023
INSPECTION - RESIDENTIAL ¤514.25 08/07/2023
PLAN REVIEW - RESIDENTIAL ¤145.86 08/07/2023
CONNECTION FEES ¤1,166.26 08/07/2023
FIRE IMPACT FEE ADMIN ¤12.62 08/07/2023
FIRE IMPACT FEE ADMIN (¤12.62) 08/07/2023
FC IMPACT FEE EMS ¤62.00 08/07/2023
IMPACT FEE FIRE ¤420.52 08/07/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 08/07/2023
FC IMPACT FEE LIBRARY ¤268.00 08/07/2023
IMPACT FEE PARKS ¤1,769.15 08/07/2023
IMPACT FEE SCHOOL ¤5,450.00 08/07/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 08/07/2023
WATER -IRRIGATION INSPECTION ¤25.00 08/07/2023
PARKS IMPACT FEE ADMIN ¤53.07 08/07/2023
PARKS IMPACT FEE ADMIN (¤53.07) 08/07/2023
SURCHARGE FS 533.721 ¤3.45 08/07/2023
SURCHARGE - FS 468.631 ¤5.18 08/07/2023
SW ENG - FOUNDATION SURVEY ¤20.00 08/07/2023
SW ENG INSPECTION 80 ¤80.00 08/07/2023
SW ENG PRE APRON ¤30.00 08/07/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,387.53