I want to search for...
Permit #2023070330
Permit Details
Status: CANCEL
| Parcel Id: 07-11-31-7035-00400-0230 |
| Block: 00400 |
| Subdivision: 2172 - SECTION 35-BELLE TERRE |
| Job Phone: 386-234-9464 |
| Location Address: 18 BURROUGHS DR |
| Type: DR - DRIVEWAY |
| Issue Date: 07/25/2023 |
| NOC: RECORDED |
| Applicant name: CYRUS BROWN |
| Owner: OMS SHEILYN |
|
Address 18 BURROUGHS DRIVE PALM COAST, FL 32137 |
| Lot: 0230 |
| Contracted Stated Job Value: ¤8,720.00 |
| Job Description: 12 FEET CONCRETE CIRCLE DRIVEWAY |
| Type: CN |
Contractor
FLAGLER FINISH & CONCRETE LLC
| Status | Location Address | Mailing Address | Phone |
| ACTIVE |
101 PALM HARBOR PKWY BUNNELL, FL 32110 |
#209A PALM COAST, FL 32137 |
386-234-9464 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL APRON (AFTER POUR) | 05/14/2024 | Disapproved - NO FEE | EMADISON |
| Note: ** 05/14/24 NEED TO REMOVE HOT PATCH FROM CHIPPED EDGE OF APRON AND REPAIR CONCRETE EDGE WITH CONCRETE AS NOTED IN PREVIOUS INSPECTION ON 12/05/23 ____________________________________________________________________________________________________________________ 12/5/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE THE CHIPS IN THE DRIVEWAY FIXED BEFORE PASSING 2) NEED TO HAVE THE ROAD DAMAGE REPAIRED WITH HOT PATCH BEFORE PASSING | |||
| ROW - FINAL INSPECTION | 05/14/2024 | Disapproved - NO FEE | EMADISON |
| Note: ** 05/14/24 NEED TO FILL HOLE AND SOD AT END OF CULVERT ON LEFT SIDE AS NOTED IN THE PREVIOUS INSPECTION ON 12/05/23 ______________________________________________________________________________________________________________ 12/5/2023 - PREVIOUS INSPECTION NOTES NEED TO HAVE SOD AT THE END OF CULVERT ON THE LEFT SIDE OF DRIVEWAY RIGHT NOW THERE IS A BIG HOLE NEEDS FILLED AND SODED | |||
| ROW - FINAL APRON (AFTER POUR) | 12/05/2023 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) NEED TO HAVE THE CHIPS IN THE DRIVEWAY FIXED BEFORE PASSING 2) NEED TO HAVE THE ROAD DAMAGE REPAIRED WITH HOT PATCH BEFORE PASSING | |||
| ROW - FINAL INSPECTION | 12/05/2023 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: NEED TO HAVE SOD AT THE END OF CULVERT ON THE LEFT SIDE OF DRIVEWAY RIGHT NOW THERE IS A BIG HOLE NEEDS FILLED AND SODED | |||
| U -UTILITY RESIDENTIAL FINAL | 12/05/2023 | FINAL APPROVED | DHANEY |
| ROW- PRE-APRON (PRE-POUR) | 08/01/2023 | APPROVED - AS NOTED | EMADISON |
| Note: ** 08/01/23 At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. 88ec.900.04C Residential driveways shall be constructed using material with a minimum of three thousand pounds (3,000 Ibs.) per square inch with Fiber or wire mesh. ______________________________________________________________________________________________________________________ 7/28/2023 - PREVIOUS INSPECTION NOTE 7/27/2023 - PREVIOUS INSPECTION NOTES ** 07/27/23 REMOVE (2) SPRINKLER HEADS ALONG OLD DRIVEWAY THAT ARE IN POUR AREA ** NEED A MINIMUM OF 4 INCHES OF CONCRETE IN DRIVEAY POUR AREA ABOVE THE ROW (ALONG OLD DRIVEWAY ** NEED TO EXTEND FORM BOARDS TO LARGE OF AN OPENING NEED TO CONTAIN CONCRETE WITHIN POUR AREA ** AREAS OF CONCERN HIGHJ LIGHTED WITH WHITE PAINT ** CULVERT GOOD AT THE TIME OF INSPECTION ** SEE ATTACHED PHOTOS ___________________________________________________________________________________________________________________ | |||
| ROW- PRE-APRON (PRE-POUR) | 07/28/2023 | CANCELLED BY APPLICANT | EMADISON |
| Note: 7/27/2023 - PREVIOUS INSPECTION NOTES ** 07/27/23 REMOVE (2) SPRINKLER HEADS ALONG OLD DRIVEWAY THAT ARE IN POUR AREA ** NEED A MINIMUM OF 4 INCHES OF CONCRETE IN DRIVEAY POUR AREA ABOVE THE ROW (ALONG OLD DRIVEWAY ** NEED TO EXTEND FORM BOARDS TO LARGE OF AN OPENING NEED TO CONTAIN CONCRETE WITHIN POUR AREA ** AREAS OF CONCERN HIGHJ LIGHTED WITH WHITE PAINT ** CULVERT GOOD AT THE TIME OF INSPECTION ** SEE ATTACHED PHOTOS ___________________________________________________________________________________________________________________ | |||
| ROW- PRE-APRON (PRE-POUR) | 07/27/2023 | Disapproved -FEE REQUIRED | EMADISON |
| Note: ** 07/27/23 REMOVE (2) SPRINKLER HEADS ALONG OLD DRIVEWAY THAT ARE IN POUR AREA ** NEED A MINIMUM OF 4 INCHES OF CONCRETE IN DRIVEAY POUR AREA ABOVE THE ROW (ALONG OLD DRIVEWAY ** NEED TO EXTEND FORM BOARDS TO LARGE OF AN OPENING NEED TO CONTAIN CONCRETE WITHIN POUR AREA ** AREAS OF CONCERN HIGHJ LIGHTED WITH WHITE PAINT ** CULVERT GOOD AT THE TIME OF INSPECTION ** SEE ATTACHED PHOTOS ___________________________________________________________________________________________________________________ | |||
| ROW - FINAL INSPECTION | |||
| Note: 5/14/2024 - PREVIOUS INSPECTION NOTES ** 05/14/24 NEED TO FILL HOLE AND SOD AT END OF CULVERT ON LEFT SIDE AS NOTED IN THE PREVIOUS INSPECTION ON 12/05/23 ______________________________________________________________________________________________________________ 12/5/2023 - PREVIOUS INSPECTION NOTES NEED TO HAVE SOD AT THE END OF CULVERT ON THE LEFT SIDE OF DRIVEWAY RIGHT NOW THERE IS A BIG HOLE NEEDS FILLED AND SODED | |||
| ROW - FINAL APRON (AFTER POUR) | |||
| Note: 5/14/2024 - PREVIOUS INSPECTION NOTES ** 05/14/24 NEED TO REMOVE HOT PATCH FROM CHIPPED EDGE OF APRON AND REPAIR CONCRETE EDGE WITH CONCRETE AS NOTED IN PREVIOUS INSPECTION ON 12/05/23 ____________________________________________________________________________________________________________________ 12/5/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO HAVE THE CHIPS IN THE DRIVEWAY FIXED BEFORE PASSING 2) NEED TO HAVE THE ROAD DAMAGE REPAIRED WITH HOT PATCH BEFORE PASSING |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 07/10/2023 | 07/12/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| UTL | COMPLETE | 07/10/2023 | 07/17/2023 |
| Note: Released By: LARRY FITZGERALD - (386)286-2041 - LFITZGERALD@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/10/2023 | 07/10/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG REINSPECTION 20 | ¤20.00 | 05/13/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 05/13/2024 |
| SW ENG REINSPECTION 30 | ¤30.00 | 07/31/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 07/25/2023 |
| SITE PLAN 15 | ¤15.00 | 07/25/2023 |
| ADJUSTMENT 50% | (¤15.00) | 07/25/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 07/25/2023 |
| SW ENG INSPECTION 40 | ¤40.00 | 07/25/2023 |
| SW ENG PRE APRON | ¤30.00 | 07/25/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤370.00 |