I want to search for...
Permit #2023070707
Permit Details
Status: COED
| Parcel Id: 05-12-31-2755-00000-0050 |
| CONDITIONED SPACE: 1806 sqft |
| GARAGE: 458 sqft |
| OPENED PORCH (WITH ROOF) : 248 sqft |
| Total Square Footage: 2512 sqft |
| Block: 00000 |
| Subdivision: 2313 - THE GABLES SUBDIVISION |
| Job Phone: (386)756-0439 |
| Location Address: 209 HAWTHORN AVE |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/02/2023 |
| NOC: RECORDED |
| Applicant name: JAMES MICHAEL MATHER |
| Owner: PAYTAS HOMES INC |
|
Address PO BOX 290490 PORT ORANGE, FL 32127 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
PAYTAS HOMES INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 290490 PORT ORANGE, FL 32127 |
CBC1261873 (Exp: 08/31/2026) | (386)756-0439 |
Sub Contractors
GERALD EDWARD MASTERS JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
505 HERBERT STREET PORT ORANGE, FL 32129 |
EC13003217 (Exp: 08/31/2026) | (386)304-2600 |
DANIEL P HUCKS
| Status | Location Address | State License Number | Phone | Fax |
| CANCEL |
400 N. U.S. 1 Ormond Beach, FL 32174 |
CAC029376 (Exp: 08/31/2024) | 386-672-8494 | 386-673-7856 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
IAN MICHEAL JOHNSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
4244 JACKSON STREET PORT ORANGE, FL 32127 |
CCC1325915 (Exp: 08/31/2026) | 386-760-0764 | 386-760-3080 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 01/23/2024 | FINAL APPROVED | STHOMAS |
| ROW - STORMWATER FINAL | 01/23/2024 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. -------------------------------------------------------------------------------------- 1/10/2024 - PREVIOUS INSPECTION NOTES 1/10/24= THERE IS AN ISSUE WITH EXCESS WATER ACCUMULATING BETWEEN THE TWO HOUSES LOCATED AT #209 AND 211 ON THE RIGHT SIDE OF THE PROPERTY. THE DRAINAGE CONVAYANCE SYSTEM BETWEEN THE HOUSES NEEDS TO BE REDESIGNED TO ENSURE THAT WATER FLOWS FROM THE BACK TO THE FRONT. 12/29/23 UPON WALKING PROPERTY DETERMINED THAT YOU MAY NEED ON THE LEFT SIDE FRONT AT ADJOINING PROPERTY LINE TO REMOVE THE CLOSEST BUSH AND PORTION OF THE MULCH IN THE DRAINAGE CONVEYANCE TO ALLOW PROPER POSITIVE DRAINAGE WITHOUT WASHING MULCH OUT AND INTO THE ROADWAY. APPROVING THIS INSPECTION AS NOTED. WILL CHECK TO SEE FOR ANY CONFLICT WITH HOA COVENANT. | |||
| U -UTILITY RESIDENTIAL FINAL | 01/10/2024 | FINAL APPROVED | JHARDING |
| ROW - STORMWATER FINAL | 01/10/2024 | Disapproved - NO FEE | GBERTOLA |
| Note: 1/10/24= THERE IS AN ISSUE WITH EXCESS WATER ACCUMULATING BETWEEN THE TWO HOUSES LOCATED AT #209 AND 211 ON THE RIGHT SIDE OF THE PROPERTY. THE DRAINAGE CONVAYANCE SYSTEM BETWEEN THE HOUSES NEEDS TO BE REDESIGNED TO ENSURE THAT WATER FLOWS FROM THE BACK TO THE FRONT. 12/29/23 UPON WALKING PROPERTY DETERMINED THAT YOU MAY NEED ON THE LEFT SIDE FRONT AT ADJOINING PROPERTY LINE TO REMOVE THE CLOSEST BUSH AND PORTION OF THE MULCH IN THE DRAINAGE CONVEYANCE TO ALLOW PROPER POSITIVE DRAINAGE WITHOUT WASHING MULCH OUT AND INTO THE ROADWAY. APPROVING THIS INSPECTION AS NOTED. WILL CHECK TO SEE FOR ANY CONFLICT WITH HOA COVENANT. | |||
| ROW - FINAL APRON (AFTER POUR) | 01/10/2024 | APPROVED | GBERTOLA |
| Note: 1/10/24=AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. THIS INCLUDES BUT IS NOT LIMITED TO THE CULVERT PIPE ELEVATION APPROVAL FOR THE CONCRETE POUR. 12/29/23 UPON WALKING PROPERTY DETERMINED THAT YOU MAY NEED ON THE LEFT SIDE FRONT AT ADJOINING PROPERTY LINE TO REMOVE THE CLOSEST BUSH AND PORTION OF THE MULCH IN THE DRAINAGE CONVEYANCE TO ALLOW PROPER POSITIVE DRAINAGE WITHOUT WASHING MULCH OUT AND INTO THE ROADWAY. APPROVING THIS INSPECTION AS NOTED. WILL CHECK TO SEE FOR ANY CONFLICT WITH HOA COVENANT. | |||
| U-CROSS CONNECTION | 01/10/2024 | APPROVED - AS NOTED | JHARDING |
| Note: No cross connections. | |||
| ELECTRIC - EARLY POWER | 01/02/2024 | Approval - Private Provider | PPROVIDER |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/29/2023 | APPROVED | FSLADISH |
| Note: Inspector Notes from Inspection 9270 12/5/23 ** SPREAD AND COMPACTION INSPECTION COMPLETE YOU MAY NOW LAY PAVERS AT THE TIME OF INSPECTION ________________________________________________________________________ Inspector Notes from Inspection 9271 11/30/23 YOU ARE READY TO POUR PAVER RESTRAINTS AT THIS TIME. DO NOT LAY ANY PAVERS | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/29/2023 | APPROVED - AS NOTED | FSLADISH |
| Note: 12/29/23 UPON WALKING PROPERTY DETERMINED THAT YOU MAY NEED ON THE LEFT SIDE FRONT AT ADJOINING PROPERTY LINE TO REMOVE THE CLOSEST BUSH AND PORTION OF THE MULCH IN THE DRAINAGE CONVEYANCE TO ALLOW PROPER POSITIVE DRAINAGE WITHOUT WASHING MULCH OUT AND INTO THE ROADWAY. APPROVING THIS INSPECTION AS NOTED. WILL CHECK TO SEE FOR ANY CONFLICT WITH HOA COVENANT. | |||
| ROW- PRE-APRON (PRE-POUR) | 12/05/2023 | APPROVED - AS NOTED | TPOLACEK |
| Note: 12/5/23 ** SPREAD AND COMPACTION INSPECTION COMPLETE YOU MAY NOW LAY PAVERS AT THE TIME OF INSPECTION ________________________________________________________________________ Inspector Notes from Inspection 9271 11/30/23 YOU ARE READY TO POUR PAVER RESTRAINTS AT THIS TIME. DO NOT LAY ANY PAVERS | |||
| ROW- PAVER RESTRAINTS | 11/30/2023 | APPROVED - AS NOTED | FSLADISH |
| Note: 11/30/23 YOU ARE READY TO POUR PAVER RESTRAINTS AT THIS TIME. DO NOT LAY ANY PAVERS | |||
| ROW- PRE-APRON (PRE-POUR) | 11/30/2023 | PARTIALLY APPROVED | FSLADISH |
| Note: 11/30/23 YOU ARE APPROVED TO POUR DRIVEWAY APRON AND PAVER RESTRAINTS AS OF THIS INSPECTION. DO NOT LAY ANY PAVERS AT THIS TIME. NEXT INSPECTION WILL BE FOR PAVER BASE SPREAD AND COMPACTION. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. | |||
| U - SEWER TIE IN | 11/28/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 11/22/2023 | Approval - Private Provider | PPROVIDER |
| INSULATION | 11/01/2023 | Approval - Private Provider | PPROVIDER |
| ALL ROUGH | 10/27/2023 | Approval - Private Provider | PPROVIDER |
| WALL SHEATHING | 10/26/2023 | Approval - Private Provider | PPROVIDER |
| LATH/BRICK/ WATER BARRIER | 10/24/2023 | Approval - Private Provider | PPROVIDER |
| ROOF VALLEY & METAL | 10/09/2023 | Approval - Private Provider | PPROVIDER |
| TIE BEAM / LINTEL | 10/02/2023 | Approval - Private Provider | PPROVIDER |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 10/02/2023 | Approval - Private Provider | PPROVIDER |
| ELECTRIC-TUG | 10/02/2023 | Approval - Private Provider | PPROVIDER |
| MONOLITHIC SLAB | 10/02/2023 | Approval - Private Provider | PPROVIDER |
| FOUND SURVEY APPROVED (OFFICE) | 08/25/2023 | APPROVED | TBAKER |
| WATER METER INSTALLATION REQUEST | 08/21/2023 | APPROVED | CBOWERMASTER |
| PLUMBING 1ST ROUGH UNDERGROUND | 08/15/2023 | Approval - Private Provider | PPROVIDER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 08/25/2023 | 08/25/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/25/2023 | 08/25/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 07/25/2023 | 07/26/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/25/2023 | 07/25/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/25/2023 | 07/31/2023 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM See not on Additional Information Page. | |||
| CUSVC | HOLD | 07/17/2023 | 07/18/2023 |
| Note: Held By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Please correct the utility application to reflect the correct property address. | |||
| ENGIN1 | COMPLETE | 07/17/2023 | 07/18/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| LOCATE | COMPLETE | 07/17/2023 | 07/24/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 07/17/2023 | 07/24/2023 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM 1) NEED TO HAVE FLOW ARROWS TO SHOW WATER DRAINAGE 2) ALL WATER IS GOING UP AGAINST THE HOUSE WATER NEEDS TO SHEET AWAY FROM HOME THE OUT TO THE ROAD | |||
| ZON | HOLD | 07/17/2023 | 07/18/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Color sheet must state that the siding will match the stucco color Horizontal band must wrap corner at least 2 foot Please provide the width of the walkway on site plan/survey | |||
| URB | COMPLETE | 07/17/2023 | 07/19/2023 |
| Note: Released By: JOHN BEAUDET - (386)986-2456 - JBEAUDET@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| WATER-METER | ¤505.39 | 08/02/2023 |
| WATER-METER | ¤419.86 | 08/02/2023 |
| ADJUSTMENT 50% | (¤15.00) | 08/02/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/02/2023 |
| ADMINISTRATIVE - RESID PP | ¤225.00 | 08/02/2023 |
| CONNECTION FEES | ¤25.00 | 08/02/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 08/02/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 08/02/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 08/02/2023 |
| IMPACT FEE FIRE | ¤420.52 | 08/02/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 08/02/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 08/02/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 08/02/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 08/02/2023 |
| RECORDING FEE REIMBURSE DOC | ¤44.00 | 08/02/2023 |
| IMPACT FEE TRANSPORTATION | ¤3,311.00 | 08/02/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 08/02/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 08/02/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 08/02/2023 |
| SURCHARGE FS 533.721 | ¤2.40 | 08/02/2023 |
| SURCHARGE - FS 468.631 | ¤3.60 | 08/02/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 08/02/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 08/02/2023 |
| SW ENG PRE APRON | ¤30.00 | 08/02/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 08/02/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 08/02/2023 |
| TRANS IMPACT FEE ADMIN | ¤99.33 | 08/02/2023 |
| TRANS IMPACT FEE ADMIN | (¤99.33) | 08/02/2023 |
| SEWER INSPECTION | ¤25.00 | 08/02/2023 |
| SITE PLAN 30 | ¤30.00 | 08/02/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤13,168.92 |