I want to search for...

Permit #2023070793

Permit Details

Status: COED

Parcel Id: 07-11-31-7026-00020-0280
CONDITIONED SPACE: 1392 sqft
GARAGE: 450 sqft
OPENED PORCH (WITH ROOF) : 130 sqft
SCREEN PORCH (SOLID ROOF) : 72 sqft
CONDITIONED SPACE: 1392 sqft
GARAGE: 450 sqft
OPENED PORCH (WITH ROOF) : 72 sqft
OPENED PORCH (WITH ROOF) : 130 sqft
Total Square Footage: 4088 sqft
Block: 00020
Subdivision: 2153 - SECTION 26-PINE GROVE
Job Phone: 386-627-0430
Location Address: 40 PINE HILL LN
Type: DU - DUPLEX
Issue Date: 08/15/2023
NOC: RECORDED
Applicant name: ANNA WIKTORIA LISOWSKI
Owner: LESNIEWSKI PIOTR & ADRIANA H&W

Address

63 JACKLYN CT

INWOOD, NY 11096

Lot: 0280
Contracted Stated Job Value: ¤400,000.00
Job Description: Duplex
Type: CN

Contractor

GOLDEN FOX HOME REMODELING, INC
Status Location Address State License Number Phone
ACTIVE

72 HERNANDEZ AVE

PALM COAST, FL 32137

CBC1259266 (Exp: 08/31/2026) 386-627-0430

Sub Contractors

DANIEL J LUSINSKI
Status Location Address Mailing Address State License Number Phone
ACTIVE

389 PALM COAST PARKWAY SW

PALM COAST, FL 32137

#4

PALM COAST, FL 32137

CCC1330133 (Exp: 08/31/2026) 386-338-7926
WILLIAM TODD SIKES
Status Location Address State License Number Phone
ACTIVE

83 PORT ROYAL DR

ST AUGUSTINE, FL 32084

EC0002726 (Exp: 08/31/2026) 904-762-8762
JUAN CARLOS GONZALEZ
Status Location Address State License Number
ACTIVE

1328 COUNTY ROAD 308

CRESCENT CITY, FL 32112

RF11067806 (Exp: 08/31/2027)
SCOTT H STILLWELL
Status Location Address State License Number Phone
ACTIVE

4500 US 1 UNIT 206

BUNNELL, FL 32110

CAC1819433 (Exp: 08/31/2026) 386-864-4404

Inspection History

Type Request Date Result Inspector
U-CROSS CONNECTION 03/14/2024 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no crooss connectin
ROW - FINAL APRON (AFTER POUR) 03/13/2024 APPROVED PFLANAGAN
Note: CORRECTIONS MADE --------------------------------------------------------------- ** 03/11/24 BEFORE ROW FINAL ** BUILDER IS REQUIRED TO REMOVE LARGE CHUNK OF CONCRETE THAT WAS DUMPED IN VACANT ACROSS THE STREET (NOTE WHITE ARROW POINTING IN DIRECTION) ** REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ACROSS STREET ** REPAIR AND SOD ROW IN VACANT ACROSS THE STREET TO MATCH THE EXISTING GRADE DO NOT SET SOD TOP CREATE A DAM ***NEEDS TO BE CUT IN***
ROW - FINAL INSPECTION 03/13/2024 APPROVED PFLANAGAN
Note: CORRECTIONS MADE ---------------------------------------------------------------- ** 03/11/24 BEFORE ROW FINAL ** BUILDER IS REQUIRED TO REMOVE LARGE CHUNK OF CONCRETE THAT WAS DUMPED IN VACANT ACROSS THE STREET (NOTE WHITE ARROW POINTING IN DIRECTION) ** REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ACROSS STREET ** REPAIR AND SOD ROW IN VACANT ACROSS THE STREET TO MATCH THE EXISTING GRADE DO NOT SET SOD TOP CREATE A DAM ***NEEDS TO BE CUT IN***
U -UTILITY RESIDENTIAL FINAL 03/13/2024 FINAL APPROVED LFITZGERALD
BLD - BUILDING FINAL 03/12/2024 FINAL APPROVED KSANDOE
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/11/2024 APPROVED EMADISON
Note: 3/7/2024 - PREVIOUS INSPECTION NOTES 1) ALL THE ELEVATIONS AGAINST THE STRUCTURE NEED TO BE A MINIMUM OF 4" BELOW FFE. Section 300.01 (A)(1)(C)(6) .Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. 2) WHEN WALKING THE PROPERTY TO VERIFY THE FINAL SURVEY ACCURACY. I NOTICE THAT THE 10' OFF SET ELEVATIONS ON BOTH SIDE ADJACENT PROPERTYS CAN NOT BE THE CORRECT ELEVATIONS. NEED TO GET SURVEYOR TO COME OUT TO COLLECT THE RIGHT ELEVATION SO THERE IS NO INCONSISTENCYS IN THE FIELD AND THE FINAL SURVEY. ALSO WITH THE ELEVATION BEING WRONG THE DRAINAGE DOESN'T MEET CITY STANDARDS. HERE IS THE CODE FOR THIS STANDARD Sec. 300.04 E7 The top of slope of “w” swales along the property lines shall be a minimum of 0.30 feet higher than the toe of slope.
ROW FIELD SURVEY /GRADING CERTIFICATION 03/11/2024 APPROVED - AS NOTED EMADISON
Note: ** 03/11/24 BEFORE ROW FINAL ** BUILDER IS REQUIRED TO REMOVE LARGE CHUNK OF CONCRETE THAT WAS DUMPED IN VACANT ACROSS THE STREET (NOTE WHITE ARROW POINTING IN DIRECTION) ** REMOVE ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANT ACROSS STREET ** REPAIR AND SOD ROW IN VACANT ACROSS THE STREET TO MATCH THE EXISTING GRADE DO NOT SET SOD TOP CREATE A DAM ***NEEDS TO BE CUT IN***
ROW- FINAL SURVEY/GRADING CERTIFICATION 03/07/2024 Disapproved - NO FEE PFLANAGAN
Note: 1) ALL THE ELEVATIONS AGAINST THE STRUCTURE NEED TO BE A MINIMUM OF 4" BELOW FFE. Section 300.01 (A)(1)(C)(6) .Sod elevations adjacent to the structure are 4” below the FFE for block and 6” for wood frame structures. 2) WHEN WALKING THE PROPERTY TO VERIFY THE FINAL SURVEY ACCURACY. I NOTICE THAT THE 10' OFF SET ELEVATIONS ON BOTH SIDE ADJACENT PROPERTYS CAN NOT BE THE CORRECT ELEVATIONS. NEED TO GET SURVEYOR TO COME OUT TO COLLECT THE RIGHT ELEVATION SO THERE IS NO INCONSISTENCYS IN THE FIELD AND THE FINAL SURVEY. ALSO WITH THE ELEVATION BEING WRONG THE DRAINAGE DOESN'T MEET CITY STANDARDS. HERE IS THE CODE FOR THIS STANDARD Sec. 300.04 E7 The top of slope of “w” swales along the property lines shall be a minimum of 0.30 feet higher than the toe of slope.
ROW- PRE-APRON (PRE-POUR) 02/01/2024 APPROVED PFLANAGAN
Note: CORRECTION MADE ON THE LEFT CULVERT IT IS NOW 8' FROM EDGE OF PAVEMENT. READY TO POUR BOTH CULVERTS. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ---------------------------------------------------------------------------------------------- 1/31/2024 - PREVIOUS INSPECTION NOTES OK TO POUR THE RIGHT DRIVEWAY ONLY IF YOU ARE FACE THE HOUSE FROM THE STREET. LEFT DRIVEWAY LEFT SIDE OF CULVERT IT TO CLOSE TO THE EDGE OF PAVEMENT BY 6" NEED TO MOVE CULVERT 6" TOWARDS THE HOUSE. TALK TO SAM WITH GOLDEN FOX AND WANTS ME TO RESCHEDULE THE PRE POUR FOR TOMORROW 2/1/24
ROW- PRE-APRON (PRE-POUR) 01/31/2024 PARTIALLY APPROVED PFLANAGAN
Note: OK TO POUR THE RIGHT DRIVEWAY ONLY IF YOU ARE FACE THE HOUSE FROM THE STREET. LEFT DRIVEWAY LEFT SIDE OF CULVERT IT TO CLOSE TO THE EDGE OF PAVEMENT BY 6" NEED TO MOVE CULVERT 6" TOWARDS THE HOUSE. TALK TO SAM WITH GOLDEN FOX AND WANTS ME TO RESCHEDULE THE PRE POUR FOR TOMORROW 2/1/24
ELECTRIC - EARLY POWER 01/11/2024 APPROVED RSIMS
Note: 1/11/24: FPL emailed to release power.
GRAVITY SEWER TEST 01/03/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 THIS WAS APPROVED ON 9/14/23
U - SEWER TIE IN 01/03/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2060 THIS WAS APPROVED ON 9/14/23
PEP TANK INSTALLATION REQUEST 12/18/2023 APPROVED BVITALE
INSULATION 12/12/2023 APPROVED KSANDOE
ALL ROUGH 12/06/2023 APPROVED KSANDOE
Note: Swale needs to be maintained clear and free flowing 12/4/2023 - PREVIOUS INSPECTION NOTES 1. Metalic pancake boxes are filled with stucco, must be cleaned out to ensure ground screw and proper bond 2. Ser cable is required to be secured within 12'' of panel 3. Dryer vent has wrong nail plates, Nail plates for mech. duct require the extend 2'' below top plate 4. Dryer vent seam is required to be sealed Stopped inspection not ready
ALL ROUGH 12/04/2023 Disapproved - NO FEE MKRASKI
Note: 1. Metalic pancake boxes are filled with stucco, must be cleaned out to ensure ground screw and proper bond 2. Ser cable is required to be secured within 12'' of panel 3. Dryer vent has wrong nail plates, Nail plates for mech. duct require the extend 2'' below top plate 4. Dryer vent seam is required to be sealed Stopped inspection not ready
LATH/BRICK/ WATER BARRIER 11/15/2023 APPROVED KSANDOE
Note: 11/14/2023 - PREVIOUS INSPECTION NOTES 11/14/23: Only the first of the two deficiencies was resolved. Please have wire lath installed over the exposed water line below the hose bib at the back of the house as previously noted. 11/13/2023 - PREVIOUS INSPECTION NOTES 11/13/23: Unit B: (Right side): Left side of garage below light box where cinder block is drilled & chipped out and Back of the unit at hose bibb requires wire lath.
LATH/BRICK/ WATER BARRIER 11/14/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/14/23: Only the first of the two deficiencies was resolved. Please have wire lath installed over the exposed water line below the hose bib at the back of the house as previously noted. 11/13/2023 - PREVIOUS INSPECTION NOTES 11/13/23: Unit B: (Right side): Left side of garage below light box where cinder block is drilled & chipped out and Back of the unit at hose bibb requires wire lath.
LATH/BRICK/ WATER BARRIER 11/13/2023 Disapproved - NO FEE RSIMS
Note: 11/13/23: Unit B: (Right side): Left side of garage below light box where cinder block is drilled & chipped out and Back of the unit at hose bibb requires wire lath.
FIREWALL FINAL 11/09/2023 APPROVED KSANDOE
FIREWALL DRYWALL NAILING 11/07/2023 APPROVED KSANDOE
ROOF VALLEY & METAL 11/02/2023 APPROVED KSANDOE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 10/31/2023 APPROVED KSANDOE
WALL SHEATHING 10/27/2023 APPROVED KSANDOE
FOUND SURVEY APPROVED (OFFICE) 10/12/2023 APPROVED TBAKER
TIE BEAM / LINTEL 10/09/2023 APPROVED KSANDOE
MONOLITHIC SLAB 09/20/2023 APPROVED KSANDOE
Note: 9/19/2023 - PREVIOUS INSPECTION NOTES Form boards and excavation for foundation cast in earth is not sufficient to contain and form concrete. Please address
MONOLITHIC SLAB 09/19/2023 Disapproved - NO FEE KSANDOE
Note: Form boards and excavation for foundation cast in earth is not sufficient to contain and form concrete. Please address
PLUMBING 1ST ROUGH UNDERGROUND 09/15/2023 APPROVED - AS NOTED MGIBSON
Note: THIS WAS APPROVED ON 9/14/23
PLUMBING 1ST ROUGH UNDERGROUND 09/14/2023 CANCELLED BY APPLICANT WEB
WATER METER INSTALLATION REQUEST 09/05/2023 APPROVED CBOWERMASTER
Note: 8/24/2023 12:43:16 PM- PREVIOUS INSPECTION NOTES logs
WATER METER INSTALLATION REQUEST 08/23/2023 Disapproved -FEE REQUIRED CBOWERMASTER
Note: logs

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 10/10/2023 10/12/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 10/10/2023 10/10/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 08/01/2023 08/01/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/01/2023 08/01/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 08/01/2023 08/09/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
LOCATE COMPLETE 08/01/2023 08/02/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
BLD COMPLETE 07/31/2023 07/31/2023
Note: Released By: JPI
ZON HOLD 07/31/2023 08/01/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Flood map panel number incorrect on survey/site plan
ELEC COMPLETE 07/31/2023 08/01/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/31/2023 08/01/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD HOLD 07/19/2023 07/19/2023
Note: Held By: JPI 1) Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
CUSVC COMPLETE 07/19/2023 07/24/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 07/19/2023 07/21/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit a duplex riser diagram that includes all wire sizes and breaker sizes
ENGIN1 COMPLETE 07/19/2023 07/19/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 07/19/2023 07/21/2023
LOCATE COMPLETE 07/19/2023 07/25/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 07/19/2023 07/21/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 07/19/2023 07/25/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 07/19/2023 07/20/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Address incorrect on plans. Should say pine hill Flood map panel number incorrect on survey/site plan Lot square footage incorrect on survey/site plan
BADMIN COMPLETE 07/19/2023 07/21/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 07/19/2023 08/09/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 03/12/2024
REINSPECTION FEE ¤40.00 03/12/2024
SURCHARGE FS 533.721 ¤7.21 08/15/2023
SURCHARGE - FS 468.631 ¤10.82 08/15/2023
SW ENG - FOUNDATION SURVEY ¤20.00 08/15/2023
SW ENG INSPECTION 80 ¤80.00 08/15/2023
SW ENG PRE APRON ¤30.00 08/15/2023
SW ENG - REVIEW 20 ¤20.00 08/15/2023
SW ENG RES REVIEW 200 ¤200.00 08/15/2023
TRANS IMPACT FEE ADMIN ¤84.36 08/15/2023
TRANS IMPACT FEE ADMIN (¤84.36) 08/15/2023
SEWER CREDIT (¤2,294.00) 08/15/2023
SEWER INSPECTION ¤25.00 08/15/2023
SEWER CAPITAL FACILITY ¤10,689.64 08/15/2023
WATER CAPITAL FACILITY FEE ¤7,847.76 08/15/2023
SITE PLAN 30 ¤30.00 08/15/2023
CONNECTION FEES ¤2,332.52 08/15/2023
FIRE IMPACT FEE ADMIN ¤25.23 08/15/2023
FIRE IMPACT FEE ADMIN (¤25.23) 08/15/2023
FC IMPACT FEE EMS ¤124.00 08/15/2023
IMPACT FEE FIRE ¤841.04 08/15/2023
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 08/15/2023
FC IMPACT FEE LIBRARY ¤536.00 08/15/2023
IMPACT FEE PARKS ¤3,538.30 08/15/2023
IMPACT FEE SCHOOL ¤10,900.00 08/15/2023
IMPACT FEE TRANSPORTATION ¤2,812.00 08/15/2023
WATER -IRRIGATION INSPECTION ¤50.00 08/15/2023
PARKS IMPACT FEE ADMIN ¤106.15 08/15/2023
PARKS IMPACT FEE ADMIN (¤106.15) 08/15/2023
WATER- TURN ON ¤50.00 08/15/2023
ADJUSTMENT 50% (¤721.00) 08/15/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/15/2023
INSPECTION - RESIDENTIAL ¤1,100.00 08/15/2023
PLAN REVIEW - RESIDENTIAL ¤312.00 08/15/2023
Fees Total Due: ¤0.00 Total Paid: ¤39,087.29