I want to search for...

Permit #2023070962

Permit Details

Status: COED

Parcel Id: 07-11-31-7032-00370-0090
CONDITIONED SPACE: 1500 sqft
GARAGE: 396 sqft
OPENED PORCH (WITH ROOF) : 112 sqft
Total Square Footage: 2008 sqft
Block: 00370
Subdivision: 2155 - SECTION 32-ROYAL PALMS
Job Phone: 202-494-2019
Location Address: 18 RUTH DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/06/2023
NOC: RECORDED
Applicant name: GARY ANDREW FISCHER
Owner: RAMIREZ ANTONINO T & JOSEFINA

Address

10071 LACROSSE AVENUE

SKOKIE, IL 60077

Lot: 0090
Contracted Stated Job Value: ¤150,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

INB HOMES
Status Location Address Mailing Address State License Number Phone
ACTIVE

3670 MAGUIRE BLVD

ORLANDO, FL 32803

SUITE 210

ORLANDO, FL 32803

CGC048746 (Exp: 08/31/2026) 407-476-8195

Sub Contractors

HEATH EDWARD SANFORD
Status Location Address State License Number Phone
ACTIVE

126 EAST END RD

SAN MATEO, FL 32187

CFC1429896 (Exp: 08/31/2026) 386-871-8823
ROBERT MICHAEL RENNER
Status Location Address State License Number Phone
ACTIVE

531 CODISCO WAY

SANFORD, FL 32771

CAC051477 (Exp: 08/31/2026) 407-333-2665
TERRY BRICE DICKERSON
Status Location Address State License Number Phone
ACTIVE

4300 ST JOHN'S PARKWAY

ALPHARETTA, GA 30009

CCC1326209 (Exp: 08/31/2026) 407-548-6733
JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/27/2024 FINAL APPROVED JWALKER
Note: 2/23/2024 - PREVIOUS INSPECTION NOTES 1. The dishwasher receptable cannot be on one of the two required kitchen counter top circuits. The breaker marked DW, at the bottom right of the electrical sub panel is not operating the dishwasher receptable. The dishwasher outlet is connected to the Kit 1 circuit. NEC 210.52 2. The heat pump is to be 3" above the ajoining grade. The pad will need to be raised FBCR-M1305.1.4.1 Ground clearance. 3. Missing grille HVAC supply in the living room.
ROW - FINAL APRON (AFTER POUR) 02/23/2024 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ---------------------------------------------------------------------------------------- 2/21/24 UPON WALKING PROPERTY DETERMINED YOU WILL NEED TO REMOVE THE BUSH AND MULCH FROM OUTLINED AREA AND REPLACE WITH SOD AT GRADE TO ALLOW DRAINAGE TO FLOW FREELY THRU DRAINAGE CONVEYANCE FROM REAR TO FRONT SWALE. APPROVING THIS FIELD SURVEY AS A COURTESY SO YOU MAY MOVE FORWARD. OTHER CORRECTIONS MAY BE DEEMED NECCESSARY ON ADDITIONAL INSPECTIONS AT INSPECTORS DISCRETION.
ROW - STORMWATER FINAL 02/23/2024 APPROVED - AS NOTED PFLANAGAN
Note: THERE ARE SOME TRASH IN YOUR LOT PLEASE PICK UP ALL TRASH AND PLEASE CLEAN CULVERT PIPE OUT NO DIRT SHOULD BE IN THE MITERED ENDS. -------------------------------------------------------------------------------------------- 2/21/24 UPON WALKING PROPERTY DETERMINED YOU WILL NEED TO REMOVE THE BUSH AND MULCH FROM OUTLINED AREA AND REPLACE WITH SOD AT GRADE TO ALLOW DRAINAGE TO FLOW FREELY THRU DRAINAGE CONVEYANCE FROM REAR TO FRONT SWALE. APPROVING THIS FIELD SURVEY AS A COURTESY SO YOU MAY MOVE FORWARD. OTHER CORRECTIONS MAY BE DEEMED NECCESSARY ON ADDITIONAL INSPECTIONS AT INSPECTORS DISCRETION.
U -UTILITY RESIDENTIAL FINAL 02/23/2024 FINAL APPROVED LFITZGERALD
BLD - BUILDING FINAL 02/23/2024 Disapproved -FEE REQUIRED JWALKER
Note: 1. The dishwasher receptable cannot be on one of the two required kitchen counter top circuits. The breaker marked DW, at the bottom right of the electrical sub panel is not operating the dishwasher receptable. The dishwasher outlet is connected to the Kit 1 circuit. NEC 210.52 2. The heat pump is to be 3" above the ajoining grade. The pad will need to be raised FBCR-M1305.1.4.1 Ground clearance. 3. Missing grille HVAC supply in the living room.
U-CROSS CONNECTION 02/22/2024 APPROVED - AS NOTED LFITZGERALD
Note: no irrigation-no cross connection
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/21/2024 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 02/21/2024 APPROVED - AS NOTED FSLADISH
Note: 2/21/24 UPON WALKING PROPERTY DETERMINED YOU WILL NEED TO REMOVE THE BUSH AND MULCH FROM OUTLINED AREA AND REPLACE WITH SOD AT GRADE TO ALLOW DRAINAGE TO FLOW FREELY THRU DRAINAGE CONVEYANCE FROM REAR TO FRONT SWALE. APPROVING THIS FIELD SURVEY AS A COURTESY SO YOU MAY MOVE FORWARD. OTHER CORRECTIONS MAY BE DEEMED NECCESSARY ON ADDITIONAL INSPECTIONS AT INSPECTORS DISCRETION.
ELECTRIC - EARLY POWER 01/30/2024 APPROVED JWALKER
ROW- PRE-APRON (PRE-POUR) 01/24/2024 APPROVED PFLANAGAN
Note: CORRECTIONS MADE IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ------------------------------------------------------------------------------------- 1/23/2024 - PREVIOUS INSPECTION NOTES 1) THE CULVERT PIPE IS PITCH MORE THAN A .10 NEED TO RESET SO CULVERT DON'T PITCH MORE THAN .10. Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan and nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) THE FORM BOARD ALONG THE ROAD EDGE HAS BEEN RAN OVER IT IS NOT ATTACHED TO FORM STAKES ANY MORE.
ROW- PRE-APRON (PRE-POUR) 01/23/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) THE CULVERT PIPE IS PITCH MORE THAN A .10 NEED TO RESET SO CULVERT DON'T PITCH MORE THAN .10. Sec 300.01c3 The driveway culvert(s) must be set within the range established by the Swale Plan and nor shall it be sloped more than 0.10 feet in the direction of the drainage flow. 2) THE FORM BOARD ALONG THE ROAD EDGE HAS BEEN RAN OVER IT IS NOT ATTACHED TO FORM STAKES ANY MORE.
U - SEWER TIE IN 01/11/2024 APPROVED MGIBSON
Note: 1/10/2024 - PREVIOUS INSPECTION NOTES CAN'T SEE TAP WATER IN HOLE
GRAVITY SEWER TEST 01/11/2024 APPROVED MGIBSON
Note: 1/10/2024 - PREVIOUS INSPECTION NOTES NO TEST ON SEWER LINE
GRAVITY SEWER TEST 01/10/2024 Disapproved - NO FEE MGIBSON
Note: NO TEST ON SEWER LINE
U - SEWER TIE IN 01/10/2024 Disapproved - NO FEE MGIBSON
Note: CAN'T SEE TAP WATER IN HOLE
INSULATION 12/14/2023 APPROVED JWALKER
LATH/BRICK/ WATER BARRIER 12/07/2023 APPROVED JWALKER
Note: Inspector Notes from Inspection 2420 Please have the approved duct layout print onsite at insulation inspection.
ALL ROUGH 12/05/2023 APPROVED - AS NOTED JWALKER
Note: Please have the approved duct layout print onsite at insulation inspection.
ELECTRIC-TUG 12/04/2023 APPROVED JWALKER
ROOF VALLEY & METAL 11/27/2023 APPROVED JWALKER
Note: Inspector Notes from Inspection 2460 11/21/23: Please have a dumpster on site and trash piles cleaned up to make site safe for inspections prior to the next inspection. Check at next inspection. * Please have the dirt like substance cleaned from EJ01 truss web 3/5 so that the original integrity can be confirmed.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/21/2023 APPROVED - AS NOTED RSIMS
Note: 11/21/23: Please have a dumpster on site and trash piles cleaned up to make site safe for inspections prior to the next inspection. Check at next inspection. * Please have the dirt like substance cleaned from EJ01 truss web 3/5 so that the original integrity can be confirmed.
ROOF SHEATHING 11/17/2023 APPROVED - AS NOTED JWALKER
Note: Trash piled up in the front yard needs to be placed in a dumpster or removed. Prior to next inspection.
WALL SHEATHING 11/17/2023 APPROVED JWALKER
FOUND SURVEY APPROVED (OFFICE) 11/15/2023 APPROVED TBAKER
TIE BEAM / LINTEL 11/07/2023 APPROVED JWALKER
MONOLITHIC SLAB 10/31/2023 APPROVED JWALKER
Note: 10/30/2023 - PREVIOUS INSPECTION NOTES Missing structual drawings, Only page S-1.1 of the structual's are in the job box. Please have a full set of approved plans onsite for all inspections.
MONOLITHIC SLAB 10/30/2023 Disapproved - NO FEE JWALKER
Note: Missing structual drawings, Only page S-1.1 of the structual's are in the job box. Please have a full set of approved plans onsite for all inspections.
PLUMBING 1ST ROUGH UNDERGROUND 10/25/2023 APPROVED MGIBSON
ROW - DRAINAGE 10/09/2023 APPROVED PFLANAGAN
Note: 10/2/2023 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAN ALL DIRT AND SEDIMENT OFF THE ROAD THIS IS AN HAZARD FOR MOTORIST 2) NEED TO EXTEND THE SILT FENCE TO THE FRONT AND STOP AT THE RIGHT OF WAY LINE AND PUT IT ACROSS THE FRONT SO SEDIMENT DOESN'T WASH BACK IN TO ROAD SIDE SWALE LEAVE AN CONSTRUCTION ENTRANCE TO GAIN ACCESS TO LOT 3) NEED TO CLEAR ROAD SIDE SWALE FRON ALL SEDIMENT SO WATER CAN FLOW TO OUTFALL 4) NEED TO PUT THE PORTER JOHN ON YOUR LOT AND OUT OF RIGHT OF WAY
ROW - DRAINAGE 10/02/2023 Disapproved - NO FEE PFLANAGAN
Note: 1) NEED TO CLEAN ALL DIRT AND SEDIMENT OFF THE ROAD THIS IS AN HAZARD FOR MOTORIST 2) NEED TO EXTEND THE SILT FENCE TO THE FRONT AND STOP AT THE RIGHT OF WAY LINE AND PUT IT ACROSS THE FRONT SO SEDIMENT DOESN'T WASH BACK IN TO ROAD SIDE SWALE LEAVE AN CONSTRUCTION ENTRANCE TO GAIN ACCESS TO LOT 3) NEED TO CLEAR ROAD SIDE SWALE FRON ALL SEDIMENT SO WATER CAN FLOW TO OUTFALL 4) NEED TO PUT THE PORTER JOHN ON YOUR LOT AND OUT OF RIGHT OF WAY
WATER METER INSTALLATION REQUEST 09/19/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 01/24/2024 01/25/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ZON COMPLETE 11/15/2023 11/15/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
ENGIN1 COMPLETE 11/15/2023 11/15/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
MECH COMPLETE 11/15/2023 11/16/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 10/30/2023 11/02/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 HOLD 10/26/2023 10/26/2023
Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Formboard survey is unacceptable as foundation survey. Please submit foundation survey showing location, dimensions and elevation of finished concrete foundation/slab.
ZON COMPLETE 10/20/2023 10/20/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 08/03/2023 08/03/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/03/2023 08/03/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 08/03/2023 08/09/2023
Note: Released By: EDWARD MADISON - - EMADISON@PALMCOASTGOV.COM
BLD COMPLETE 07/21/2023 07/26/2023
Note: Released By: JPI
CUSVC COMPLETE 07/21/2023 07/24/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 07/21/2023 07/24/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 07/21/2023 07/21/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 07/21/2023 07/25/2023
LOCATE COMPLETE 07/21/2023 07/25/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 07/21/2023 07/25/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 07/21/2023 07/28/2023
Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM
ZON HOLD 07/21/2023 07/25/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM House layout on plans do not match layout on site and landscape plans. All windows and doors facing right of way must have banding placed around them. Garage door missing banding.
SWALE COMPLETE 07/21/2023 09/11/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 02/26/2024
REINSPECTION RESIDENTIAL ¤40.00 02/26/2024
SW ENG - INSPECTION 20 ¤20.00 02/26/2024
SW ENG - INSPECTION 20 ¤20.00 02/26/2024
SW ENG REINSPECTION 30 ¤30.00 02/26/2024
SW ENG - REVIEW 20 ¤20.00 09/06/2023
SW ENG RES REVIEW 200 ¤200.00 09/06/2023
TRANS IMPACT FEE ADMIN ¤54.36 09/06/2023
TRANS IMPACT FEE ADMIN (¤54.36) 09/06/2023
SEWER CREDIT (¤1,147.00) 09/06/2023
SEWER INSPECTION ¤25.00 09/06/2023
SEWER CAPITAL FACILITY ¤5,344.82 09/06/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 09/06/2023
SITE PLAN 30 ¤30.00 09/06/2023
SW ENG INSPECTION 80 ¤80.00 09/06/2023
SW ENG PRE APRON ¤30.00 09/06/2023
WATER- TURN ON ¤25.00 09/06/2023
ADJUSTMENT 50% (¤345.06) 09/06/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/06/2023
INSPECTION - RESIDENTIAL ¤514.25 09/06/2023
PLAN REVIEW - RESIDENTIAL ¤145.86 09/06/2023
CONNECTION FEES ¤1,166.26 09/06/2023
FIRE IMPACT FEE ADMIN ¤12.62 09/06/2023
FIRE IMPACT FEE ADMIN (¤12.62) 09/06/2023
FC IMPACT FEE EMS ¤62.00 09/06/2023
IMPACT FEE FIRE ¤420.52 09/06/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 09/06/2023
FC IMPACT FEE LIBRARY ¤268.00 09/06/2023
IMPACT FEE PARKS ¤1,769.15 09/06/2023
IMPACT FEE SCHOOL ¤5,450.00 09/06/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 09/06/2023
WATER -IRRIGATION INSPECTION ¤25.00 09/06/2023
PARKS IMPACT FEE ADMIN ¤53.07 09/06/2023
PARKS IMPACT FEE ADMIN (¤53.07) 09/06/2023
SURCHARGE FS 533.721 ¤3.45 09/06/2023
SURCHARGE - FS 468.631 ¤5.18 09/06/2023
SW ENG - FOUNDATION SURVEY ¤20.00 09/06/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,238.81