Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7034-00530-0090 |
| Block: 00530 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-236-9610 |
| Location Address: 39 ELDER DR |
| Type: PO - POOL |
| Issue Date: 08/08/2023 |
| NOC: RECORDED |
| Applicant name: SAMANTHA JESSICA ALEXANDER |
| Owner: SIBIGTROTH GREGG & LINDA HOULIHAN JTWROS |
|
Address 39 ELDER DRIVE PALM COAST, FL 32164 |
| Lot: 0090 |
| Contracted Stated Job Value: ¤80,000.00 |
| Job Description: swimming pool & enclosure |
| Type: CN |
Contractor
AGUA POOLS AND SPA INC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3438 LONGLEAF ROAD , |
CPC1459907 (Exp: 08/31/2026) | 386-492-6910 |
Sub Contractors
CHARLES K DAVIS
| Status | Location Address | State License Number | Phone |
| INACTIVE |
1410 RIDGEWOOD AVE HOLLY HILL, FL 32117 |
EC13011552 (Exp: 08/31/2026) | 386-236-9610 |
CHRISTOPHER DEAN BAZZLE
| Status | Location Address | State License Number | Phone |
| INACTIVE |
400 B 8TH ST , 0 |
CRC1333793 (Exp: 08/31/2026) | 386-492-6910 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 05/03/2024 | FINAL APPROVED | RSIMS |
| Note: 4/29/2024 - PREVIOUS INSPECTION NOTES 4/29/24: No one home at time of inspection. 1). Pool alarms are not in pool, hot tub or visibly in house. R4501.17.1.9(3) 2). Right side screen door stays open for a very long time before closing very slowly. Closer needs adjustment or replacement. Also, bottom door seal drags heavily on paver blocks. R4501.17.1.9(2). 3). Left side screen door closer needs adjustment to close in an approriate length of time to prevent accidental or unauthorized access. R4501.17.1.9(2). | |||
| POOL FINAL | 04/29/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 4/29/24: No one home at time of inspection. 1). Pool alarms are not in pool, hot tub or visibly in house. R4501.17.1.9(3) 2). Right side screen door stays open for a very long time before closing very slowly. Closer needs adjustment or replacement. Also, bottom door seal drags heavily on paver blocks. R4501.17.1.9(2). 3). Left side screen door closer needs adjustment to close in an approriate length of time to prevent accidental or unauthorized access. R4501.17.1.9(2). | |||
| U -UTILITY RESIDENTIAL FINAL | 04/26/2024 | FINAL APPROVED | JHARDING |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/25/2024 | APPROVED - AS NOTED | PFLANAGAN |
| Note: TALKED TO THE HOMEOWNER ABOUT THE FINAL SURVEY AND THE SITE PLAN NOT MATCHING THE DRAINAGE IN THE BACK. THERE IS AN POND BEHIND THEM THAT THE DRAINAGE DRAINS TO. PASSING AS NOTED THAT IT WILL WORK AND NOT HAVE ANY IMPACT TO THE HOUSE. ALSO HOME OWNER WILL BE PUTTING IN DRAIN IN LOW AREA ON RIGHT SIDE OF HOUSE SO WATER WILL NOT SIT ON THE HOUSE AND MOVE THE WATER TO THE FRONT. --------------------------------------------------------------------------------------------------------- 4/3/2024 - PREVIOUS INSPECTION NOTES 1) THE RIGHT SIDE WHERE YOU HAD YOUR ENTRANCE TO GET TO POOL SITE THE WATER IS FLOWING BACK TO THE HOUSE ALLOWING WATER TO SIT AGAINST THE STRUCTURE. FBC CHAPTER4 R401.3 Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’. 2) THE NEW DRAINAGE OF THE LOT DOESN'T MATCH THE FLOW ARROWS THAT WAS PROPOSED AT BEFORE PERMIT WAS ISSUED. 3) AS STATED IN THE LAST INSPECTION ALL IMPROVED LOTS SURROUNDING THIS LOT NEEDS TO BE IDENITYED AS IMPROVED AND NEED FFE ON ALL STRUCTURES AND DRAINAGE FEATURES WHICH INCLUDES CULVERT PIPE FOR DRIVEWAYS WITH IN 100'. Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. 4) THE NEW DRAINAGE IS IMPACTING THE ADJACENT LOT TO THE LEFT STATES THE FINAL SURVEY ELEVATION THAT WAS PROVIDED. Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property ----------------------------------------------------------------------------------------- 2/26/2024 - PREVIOUS INSPECTION NOTES JUST LIKE LAST INSPECTION RESULTS THIS SURVEY DOESN'T HAVE ANY ELEVATIONS TO DETERMIND IF THE DRAINAGE WORKS FOR THE NEW POOL. NEED TO HAVE A FINAL SURVEY WITH TOPO GRAPHIC ELEVATIONS EVERY 20' AND NEEDS TO CAPTURE ALL DRAINAGE FEATURES ON PROPERTY. NEED TO HAVE ELEVATIONS ON ALL ADJACENT LOTS 10' OFF THE PROPERTY LINES. Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. ---------------------------------------------------------------------------------------------- 2/21/2024 - PREVIOUS INSPECTION NOTES 2/21/24 THIS IS A BOUNDARY SURVEY. WE NEED A FINAL SURVEY SHOWING COPC REQUIRED ELEVATION SHOTS TO DETERMINE IF THE DRAINAGE IS GOING TO COFORM TO THE CPOC DRAINAGE SPECIFICATION REQUIREMENTS. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/25/2024 | APPROVED | PFLANAGAN |
| Note: Inspector Notes from Inspection 9463 TALKED TO THE HOMEOWNER ABOUT THE FINAL SURVEY AND THE SITE PLAN NOT MATCHING THE DRAINAGE IN THE BACK. THERE IS AN POND BEHIND THEM THAT THE DRAINAGE DRAINS TO. PASSING AS NOTED THAT IT WILL WORK AND NOT HAVE ANY IMPACT TO THE HOUSE. ALSO HOME OWNER WILL BE PUTTING IN DRAIN IN LOW AREA ON RIGHT SIDE OF HOUSE SO WATER WILL NOT SIT ON THE HOUSE AND MOVE THE WATER TO THE FRONT. | |||
| ROW - FINAL INSPECTION | 04/25/2024 | APPROVED | PFLANAGAN |
| Note: ROW DAMAGE IS FIX AT THIS TIME OF THIS INSPECTION | |||
| ROW- PROJECT STATUS | 04/25/2024 | APPROVED | PFLANAGAN |
| Note: TALK TO THE HOMEOWNER ABOUT SURVEY AND THE DRAINAGE OF THE LOT | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/03/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) THE RIGHT SIDE WHERE YOU HAD YOUR ENTRANCE TO GET TO POOL SITE THE WATER IS FLOWING BACK TO THE HOUSE ALLOWING WATER TO SIT AGAINST THE STRUCTURE. FBC CHAPTER4 R401.3 Drainage from the structure is to be a 6 inch (5%) minimum slope for the first 10’. 2) THE NEW DRAINAGE OF THE LOT DOESN'T MATCH THE FLOW ARROWS THAT WAS PROPOSED AT BEFORE PERMIT WAS ISSUED. 3) AS STATED IN THE LAST INSPECTION ALL IMPROVED LOTS SURROUNDING THIS LOT NEEDS TO BE IDENITYED AS IMPROVED AND NEED FFE ON ALL STRUCTURES AND DRAINAGE FEATURES WHICH INCLUDES CULVERT PIPE FOR DRIVEWAYS WITH IN 100'. Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. 4) THE NEW DRAINAGE IS IMPACTING THE ADJACENT LOT TO THE LEFT STATES THE FINAL SURVEY ELEVATION THAT WAS PROVIDED. Section 300.01 (A)(1)(C)(6). The subject lots drainage must not negatively impact any adjacent property ----------------------------------------------------------------------------------------- 2/26/2024 - PREVIOUS INSPECTION NOTES JUST LIKE LAST INSPECTION RESULTS THIS SURVEY DOESN'T HAVE ANY ELEVATIONS TO DETERMIND IF THE DRAINAGE WORKS FOR THE NEW POOL. NEED TO HAVE A FINAL SURVEY WITH TOPO GRAPHIC ELEVATIONS EVERY 20' AND NEEDS TO CAPTURE ALL DRAINAGE FEATURES ON PROPERTY. NEED TO HAVE ELEVATIONS ON ALL ADJACENT LOTS 10' OFF THE PROPERTY LINES. Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. ---------------------------------------------------------------------------------------------- 2/21/2024 - PREVIOUS INSPECTION NOTES 2/21/24 THIS IS A BOUNDARY SURVEY. WE NEED A FINAL SURVEY SHOWING COPC REQUIRED ELEVATION SHOTS TO DETERMINE IF THE DRAINAGE IS GOING TO COFORM TO THE CPOC DRAINAGE SPECIFICATION REQUIREMENTS. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/26/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: JUST LIKE LAST INSPECTION RESULTS THIS SURVEY DOESN'T HAVE ANY ELEVATIONS TO DETERMIND IF THE DRAINAGE WORKS FOR THE NEW POOL. NEED TO HAVE A FINAL SURVEY WITH TOPO GRAPHIC ELEVATIONS EVERY 20' AND NEEDS TO CAPTURE ALL DRAINAGE FEATURES ON PROPERTY. NEED TO HAVE ELEVATIONS ON ALL ADJACENT LOTS 10' OFF THE PROPERTY LINES. Sec 300.01 D2 The elevations on all adjacent identified (e.g. vacant or improved etc.) properties at a minimum of 20 foot intervals on a 10 foot offset outside the property lines. All undeveloped properties must be properly identified on the site plan and Final Survey. There must be sufficient elevation shots to indicate the intended drainage pattern. Sec 300.01D1 The elevations along all property lines must be at a minimum of 20 foot intervals. Sec 300.01 D3 The interior elevations at no greater than a 20 foot grid. There must be sufficient elevation shots to indicate the intended drainage pattern. ---------------------------------------------------------------------------------------------- 2/21/2024 - PREVIOUS INSPECTION NOTES 2/21/24 THIS IS A BOUNDARY SURVEY. WE NEED A FINAL SURVEY SHOWING COPC REQUIRED ELEVATION SHOTS TO DETERMINE IF THE DRAINAGE IS GOING TO COFORM TO THE CPOC DRAINAGE SPECIFICATION REQUIREMENTS. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/21/2024 | Disapproved - NO FEE | FSLADISH |
| Note: 2/21/24 THIS IS A BOUNDARY SURVEY. WE NEED A FINAL SURVEY SHOWING COPC REQUIRED ELEVATION SHOTS TO DETERMINE IF THE DRAINAGE IS GOING TO COFORM TO THE CPOC DRAINAGE SPECIFICATION REQUIREMENTS. | |||
| ELECTRIC AND ALARM | 11/27/2023 | APPROVED | BTAYLOR |
| POOL DECK | 10/19/2023 | APPROVED | JWALKER |
| STEEL AND GROUND | 09/11/2023 | APPROVED | RSIMS |
| Note: 9/8/2023 - PREVIOUS INSPECTION NOTES 9/8/23: ** Deep end of the pool is filled with water so visual inspection cannot be done. ** shallow end of the pool the stone has fallen under rebar reducing space under the 3" minimum required. | |||
| STEEL AND GROUND | 09/08/2023 | Disapproved - NO FEE | RSIMS |
| Note: 9/8/23: ** Deep end of the pool is filled with water so visual inspection cannot be done. ** shallow end of the pool the stone has fallen under rebar reducing space under the 3" minimum required. |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 07/31/2023 | 08/01/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/31/2023 | 08/07/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 07/25/2023 | 07/27/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 07/25/2023 | 07/27/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 07/25/2023 | 07/26/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 07/25/2023 | 07/31/2023 |
| Note: Released By: ROBERT GROSS - (386)986-4769 - RGROSS@PALMCOASTGOV.COM See notes on Additional Information Page | |||
| ZON | HOLD | 07/25/2023 | 07/26/2023 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Please provide all pool deck dimensions and location, dimensions and setbacks of pool equipment pads on site plan. |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/02/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 04/26/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 08/08/2023 |
| SITE PLAN 30 | ¤30.00 | 08/08/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 08/08/2023 |
| SURCHARGE - FS 468.631 | ¤2.00 | 08/08/2023 |
| SW ENG INSPECTION 40 | ¤40.00 | 08/08/2023 |
| ADJUSTMENT 50% | (¤127.50) | 08/08/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/08/2023 |
| INSPECTION- POOL | ¤160.00 | 08/08/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤65.00 | 08/08/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤281.50 |