Permit #2023080486
Permit Details
Status: COED
| Parcel Id: 07-11-31-7034-01580-0050 |
| CONDITIONED SPACE: 1831 sqft |
| GARAGE: 473 sqft |
| OPENED PORCH (WITH ROOF) : 116 sqft |
| OPENED PORCH (WITH ROOF) : 245 sqft |
| OPENED PORCH (WITH ROOF) : 85 sqft |
| Total Square Footage: 2750 sqft |
| Block: 01580 |
| Subdivision: 2165 - SECTION 34-EASTHAMPTON |
| Job Phone: 386-237-1210 |
| Location Address: 179 ERIC DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/21/2023 |
| NOC: RECORDED |
| Applicant name: ANDREW POPOV |
| Owner: CFHA INVESTMENTS LLC |
|
Address 2527 AMATI DRIVE KISSIMMEE, FL 34741 |
| Lot: 0050 |
| Contracted Stated Job Value: ¤300,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
SILVER BREEZE HOMES
| Status | Location Address | State License Number | Phone |
| ACTIVE |
1 SEATHORN PATH UNIT A PALM COAST, FL 32164 |
RR282812121 (Exp: 08/31/2027) | 386-237-7700 |
Sub Contractors
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
MAXIM BUDNIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
9788 HALSEY RD JACKSONVILLE, FL 32246 |
EC13007415 (Exp: 08/31/2026) | 904-509-7306 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - STORMWATER FINAL | 02/21/2025 | APPROVED | FSLADISH |
| Note: 2/21/25 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. AT THE TIME OF THIS INSPECTIONS ALL COPC REQUIREMENTS WERE MET, NEITHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. ________________________________________________________________________________________________________________________ 2/18/2025 - PREVIOUS INSPECTION NOTES 02/18/25 TPOLACEK*** ALL SOD IN ADJACENT LOT ON LEFT SIDE MUST BE DUG DOWN TO MATCH EXISTING GRADE AS DESCRIBED IN THE SWALE PLAN DIAGRAM. SOD MUST ALWAYS MATCH GRADE. DRAWING 300.F 4) MATCH SOD TO EXISTING LAWNS. Inspector Notes from Inspection 9465 2/10/25 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. INSPECTORS NOTE. DUE TO THE NUMEROUS DRAINAGE INSPECTIONS AND AS DOCUMENTED ON THE LEFT SIDE IN PARTICULAR YOU WILL BE REQUIRED TO SOD THE LEFT SIDE ADJOINING SWALE WHERE IT IS BARE BEFORE ROW FINAL PASSAGE. | |||
| BLD - BUILDING FINAL | 02/20/2025 | FINAL APPROVED | MCONTRYMAN |
| ROW - FINAL APRON (AFTER POUR) | 02/18/2025 | APPROVED | TPOLACEK |
| Note: PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. Inspector Notes from Inspection 9465 2/10/25 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. INSPECTORS NOTE. DUE TO THE NUMEROUS DRAINAGE INSPECTIONS AND AS DOCUMENTED ON THE LEFT SIDE IN PARTICULAR YOU WILL BE REQUIRED TO SOD THE LEFT SIDE ADJOINING SWALE WHERE IT IS BARE BEFORE ROW FINAL PASSAGE. | |||
| ROW - STORMWATER FINAL | 02/18/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 02/18/25 TPOLACEK*** ALL SOD IN ADJACENT LOT ON LEFT SIDE MUST BE DUG DOWN TO MATCH EXISTING GRADE AS DESCRIBED IN THE SWALE PLAN DIAGRAM. SOD MUST ALWAYS MATCH GRADE. DRAWING 300.F 4) MATCH SOD TO EXISTING LAWNS. Inspector Notes from Inspection 9465 2/10/25 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. INSPECTORS NOTE. DUE TO THE NUMEROUS DRAINAGE INSPECTIONS AND AS DOCUMENTED ON THE LEFT SIDE IN PARTICULAR YOU WILL BE REQUIRED TO SOD THE LEFT SIDE ADJOINING SWALE WHERE IT IS BARE BEFORE ROW FINAL PASSAGE. | |||
| U -UTILITY RESIDENTIAL FINAL | 02/11/2025 | FINAL APPROVED | LFITZGERALD |
| U-CROSS CONNECTION | 02/11/2025 | APPROVED - AS NOTED | BWRIGHT |
| Note: No IRR. No CC | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/10/2025 | APPROVED | FSLADISH |
| Note: Inspector Notes from Inspection 9270 TALKED WITH THE BUILDER AND HE IS GOING TO ENSURE THAT THEY HAVE 6" OF CONCRETE BEHIND THE CULVERT TO THE RIGHT OF WAY LINE. PASSING AS NOTED THAT HE STATED THAT IT WILL BE DONE. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. -------------------------------------------------------------------------------------- 1/6/2025 - PREVIOUS INSPECTION NOTES 1/6/25 NOT READY TO POUR. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/10/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 2/10/25 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. INSPECTORS NOTE. DUE TO THE NUMEROUS DRAINAGE INSPECTIONS AND AS DOCUMENTED ON THE LEFT SIDE IN PARTICULAR YOU WILL BE REQUIRED TO SOD THE LEFT SIDE ADJOINING SWALE WHERE IT IS BARE BEFORE ROW FINAL PASSAGE. | |||
| ROW- PRE-APRON (PRE-POUR) | 01/13/2025 | APPROVED - AS NOTED | PFLANAGAN |
| Note: TALKED WITH THE BUILDER AND HE IS GOING TO ENSURE THAT THEY HAVE 6" OF CONCRETE BEHIND THE CULVERT TO THE RIGHT OF WAY LINE. PASSING AS NOTED THAT HE STATED THAT IT WILL BE DONE. IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. -------------------------------------------------------------------------------------- 1/6/2025 - PREVIOUS INSPECTION NOTES 1/6/25 NOT READY TO POUR. | |||
| ROW- PRE-APRON (PRE-POUR) | 01/06/2025 | CANCELLED BY APPLICANT | FSLADISH |
| Note: 1/6/25 NOT READY TO POUR. | |||
| ELECTRIC - EARLY POWER | 11/12/2024 | APPROVED | PKNAPIK |
| Note: Release power Inspector Notes from Inspection 2170 Release Power | |||
| GRAVITY SEWER TEST | 11/07/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| U - SEWER TIE IN | 11/07/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| ROW - DRAINAGE | 10/15/2024 | APPROVED | FSLADISH |
| Note: 10/15/24 REQUIRED CORRECTIONS MADE AT THE TIME OF THIS INSPECTION. WILL MONITOR SITE FOR COMPLIANCE. ________________________________________________________________________________________________________________________ 10/14/2024 - PREVIOUS INSPECTION NOTES 10/14/24 SPOKE WITH PAUL GRADER WAS ON SITE. WILL BE FIXING THE SWALE TODAY. PARTIALLY APPROVING. WILL INSPECT TOMORROW FOR COMPLETION. ____________________________________________________________________________________________________________________ 10/11/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO DO ALL BELOW ---------------------------------------------------------------------------------------------- 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24 YOU NEED TO CLEAN OUT YOUR TEMPORARY CULVRT PIPE AND RESET IT TO GRADE. YOU ARE CAUSING A BACKUP IN THE SWALE. YOU NEED TO FIX THE WASHOUT AT THE LEFT SIDE PROPERTY LINE THE SWALE HAS ALMOST WASHED OUT TO THE ROAD EDGE. WILL BE BACK FOR COMPLIANCE REINSPECTION 10/11/24. PHOTO FOR REFERENCE. 10/13/2023 - PREVIOUS INSPECTION NOTES 10/13/23 STILL NEED TO GET PORTA POTTY OUT THE ROW AND ONTO YOUR SITE. MAKE SURE TO KEEP SWALE TO GRADE AND MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. I WILL BE BACK FOR REINSPECTION FOR COMPLIANCE ON 10/16/23. _______________________________________________________________________________________________________________________ 10/11/2023 - PREVIOUS INSPECTION NOTES 10/11/23 STILL NEED TO GET PORTA POTTY OUT THE ROW AND ONTO YOUR SITE. MAKE SURE TO KEEP SWALE TO GRADE AND MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. I WILL BE BACK FOR REINSPECTION FOR COMPLIANCE ON 10/13/23 __________________________________________________________________________________________________________________________ 10/6/2023 - PREVIOUS INSPECTION NOTES 10/06/23 SWALE IS STILL OPEN AT THIS TIME, IT WILL NEED TO BE MAINTAINED DAILY UNTIL AND AFTER TEMPORARY PIPE IS INSTALLED. WILL BE BACK ON 10/11/23 FOR REINSPECTION. NEED TO REMOVE THE PORTA POTTY FROM SWALE AND PUT IT ON YOUR SITE. _________________________________________________________________________________________________________________________ 10/5/2023 - PREVIOUS INSPECTION NOTES 10/05/23 BUILDER CALLED AND LEFT A VOICE MAIL STATING THAT THEY ARE ON SCHEDULE TO HAVE TEMPORARY CULVERT PIPE INSTALLED. AT THIS TIME THE SWALE IS GRADED. I WILL SCEDULE A DRAINAGE INSPECTION FOR TOMORROW. NO FEE __________________________________________________________________________________________________________________________ rjg. Caller at 181 says the new build is blocking the drainage of the swale. Port o potty right in the middle with no temp culvert. Please inspect. | |||
| ROW - DRAINAGE | 10/14/2024 | PARTIALLY APPROVED | FSLADISH |
| Note: 10/14/24 SPOKE WITH PAUL GRADER WAS ON SITE. WILL BE FIXING THE SWALE TODAY. PARTIALLY APPROVING. WILL INSPECT TOMORROW FOR COMPLETION. ____________________________________________________________________________________________________________________ 10/11/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO DO ALL BELOW ---------------------------------------------------------------------------------------------- 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24 YOU NEED TO CLEAN OUT YOUR TEMPORARY CULVRT PIPE AND RESET IT TO GRADE. YOU ARE CAUSING A BACKUP IN THE SWALE. YOU NEED TO FIX THE WASHOUT AT THE LEFT SIDE PROPERTY LINE THE SWALE HAS ALMOST WASHED OUT TO THE ROAD EDGE. WILL BE BACK FOR COMPLIANCE REINSPECTION 10/11/24. PHOTO FOR REFERENCE. 10/13/2023 - PREVIOUS INSPECTION NOTES 10/13/23 STILL NEED TO GET PORTA POTTY OUT THE ROW AND ONTO YOUR SITE. MAKE SURE TO KEEP SWALE TO GRADE AND MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. I WILL BE BACK FOR REINSPECTION FOR COMPLIANCE ON 10/16/23. _______________________________________________________________________________________________________________________ 10/11/2023 - PREVIOUS INSPECTION NOTES 10/11/23 STILL NEED TO GET PORTA POTTY OUT THE ROW AND ONTO YOUR SITE. MAKE SURE TO KEEP SWALE TO GRADE AND MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. I WILL BE BACK FOR REINSPECTION FOR COMPLIANCE ON 10/13/23 __________________________________________________________________________________________________________________________ 10/6/2023 - PREVIOUS INSPECTION NOTES 10/06/23 SWALE IS STILL OPEN AT THIS TIME, IT WILL NEED TO BE MAINTAINED DAILY UNTIL AND AFTER TEMPORARY PIPE IS INSTALLED. WILL BE BACK ON 10/11/23 FOR REINSPECTION. NEED TO REMOVE THE PORTA POTTY FROM SWALE AND PUT IT ON YOUR SITE. _________________________________________________________________________________________________________________________ 10/5/2023 - PREVIOUS INSPECTION NOTES 10/05/23 BUILDER CALLED AND LEFT A VOICE MAIL STATING THAT THEY ARE ON SCHEDULE TO HAVE TEMPORARY CULVERT PIPE INSTALLED. AT THIS TIME THE SWALE IS GRADED. I WILL SCEDULE A DRAINAGE INSPECTION FOR TOMORROW. NO FEE __________________________________________________________________________________________________________________________ rjg. Caller at 181 says the new build is blocking the drainage of the swale. Port o potty right in the middle with no temp culvert. Please inspect. | |||
| ROW - DRAINAGE | 10/11/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: STILL NEED TO DO ALL BELOW ---------------------------------------------------------------------------------------------- 10/7/2024 - PREVIOUS INSPECTION NOTES 10/7/24 YOU NEED TO CLEAN OUT YOUR TEMPORARY CULVRT PIPE AND RESET IT TO GRADE. YOU ARE CAUSING A BACKUP IN THE SWALE. YOU NEED TO FIX THE WASHOUT AT THE LEFT SIDE PROPERTY LINE THE SWALE HAS ALMOST WASHED OUT TO THE ROAD EDGE. WILL BE BACK FOR COMPLIANCE REINSPECTION 10/11/24. PHOTO FOR REFERENCE. 10/13/2023 - PREVIOUS INSPECTION NOTES 10/13/23 STILL NEED TO GET PORTA POTTY OUT THE ROW AND ONTO YOUR SITE. MAKE SURE TO KEEP SWALE TO GRADE AND MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. I WILL BE BACK FOR REINSPECTION FOR COMPLIANCE ON 10/16/23. _______________________________________________________________________________________________________________________ 10/11/2023 - PREVIOUS INSPECTION NOTES 10/11/23 STILL NEED TO GET PORTA POTTY OUT THE ROW AND ONTO YOUR SITE. MAKE SURE TO KEEP SWALE TO GRADE AND MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. I WILL BE BACK FOR REINSPECTION FOR COMPLIANCE ON 10/13/23 __________________________________________________________________________________________________________________________ 10/6/2023 - PREVIOUS INSPECTION NOTES 10/06/23 SWALE IS STILL OPEN AT THIS TIME, IT WILL NEED TO BE MAINTAINED DAILY UNTIL AND AFTER TEMPORARY PIPE IS INSTALLED. WILL BE BACK ON 10/11/23 FOR REINSPECTION. NEED TO REMOVE THE PORTA POTTY FROM SWALE AND PUT IT ON YOUR SITE. _________________________________________________________________________________________________________________________ 10/5/2023 - PREVIOUS INSPECTION NOTES 10/05/23 BUILDER CALLED AND LEFT A VOICE MAIL STATING THAT THEY ARE ON SCHEDULE TO HAVE TEMPORARY CULVERT PIPE INSTALLED. AT THIS TIME THE SWALE IS GRADED. I WILL SCEDULE A DRAINAGE INSPECTION FOR TOMORROW. NO FEE __________________________________________________________________________________________________________________________ rjg. Caller at 181 says the new build is blocking the drainage of the swale. Port o potty right in the middle with no temp culvert. Please inspect. | |||
| ROW - DRAINAGE | 10/07/2024 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 10/7/24 YOU NEED TO CLEAN OUT YOUR TEMPORARY CULVRT PIPE AND RESET IT TO GRADE. YOU ARE CAUSING A BACKUP IN THE SWALE. YOU NEED TO FIX THE WASHOUT AT THE LEFT SIDE PROPERTY LINE THE SWALE HAS ALMOST WASHED OUT TO THE ROAD EDGE. WILL BE BACK FOR COMPLIANCE REINSPECTION 10/11/24. PHOTO FOR REFERENCE. 10/13/2023 - PREVIOUS INSPECTION NOTES 10/13/23 STILL NEED TO GET PORTA POTTY OUT THE ROW AND ONTO YOUR SITE. MAKE SURE TO KEEP SWALE TO GRADE AND MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. I WILL BE BACK FOR REINSPECTION FOR COMPLIANCE ON 10/16/23. _______________________________________________________________________________________________________________________ 10/11/2023 - PREVIOUS INSPECTION NOTES 10/11/23 STILL NEED TO GET PORTA POTTY OUT THE ROW AND ONTO YOUR SITE. MAKE SURE TO KEEP SWALE TO GRADE AND MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. I WILL BE BACK FOR REINSPECTION FOR COMPLIANCE ON 10/13/23 __________________________________________________________________________________________________________________________ 10/6/2023 - PREVIOUS INSPECTION NOTES 10/06/23 SWALE IS STILL OPEN AT THIS TIME, IT WILL NEED TO BE MAINTAINED DAILY UNTIL AND AFTER TEMPORARY PIPE IS INSTALLED. WILL BE BACK ON 10/11/23 FOR REINSPECTION. NEED TO REMOVE THE PORTA POTTY FROM SWALE AND PUT IT ON YOUR SITE. _________________________________________________________________________________________________________________________ 10/5/2023 - PREVIOUS INSPECTION NOTES 10/05/23 BUILDER CALLED AND LEFT A VOICE MAIL STATING THAT THEY ARE ON SCHEDULE TO HAVE TEMPORARY CULVERT PIPE INSTALLED. AT THIS TIME THE SWALE IS GRADED. I WILL SCEDULE A DRAINAGE INSPECTION FOR TOMORROW. NO FEE __________________________________________________________________________________________________________________________ rjg. Caller at 181 says the new build is blocking the drainage of the swale. Port o potty right in the middle with no temp culvert. Please inspect. | |||
| PEP TANK INSTALLATION REQUEST | 10/04/2024 | APPROVED | CBOWERMASTER |
| INSULATION | 09/30/2024 | APPROVED | CVANSTRAHLEN |
| Note: 9/30/24 Approved (CV) Inspector Notes from Inspection 2420 9/24/24 1. Range nail plate must extend a min of 2'' below the top plate FBCR M1308.2 Check on insulation 9/17/2024 - PREVIOUS INSPECTION NOTES 1. No E-cals on site FBC 107.3.1 2. Product approval sheet does not match windows installed a revision is required 3. Knee wall missing for kitchen island, no outlet boxes installed NEC 210.52 4. Electrical panel is not installed properly must be secured in the wall per manufacter specs 5. Interior load bearing wall top plate has been cut in half to run exhaust vent for range, Will need a engineered letter showing an approved repair 6. Nail plate missing for range vent must extend 2'' below top plate FBCR M1308.2 7. Tub must be filled to over flow FBCR P2503.7 8. SGD and garage entry door require solid blocking gaps over 1/4'' around frames FBCR 609.1 | |||
| ALL ROUGH | 09/24/2024 | APPROVED - AS NOTED | MKRASKI |
| Note: 9/24/24 1. Range nail plate must extend a min of 2'' below the top plate FBCR M1308.2 Check on insulation 9/17/2024 - PREVIOUS INSPECTION NOTES 1. No E-cals on site FBC 107.3.1 2. Product approval sheet does not match windows installed a revision is required 3. Knee wall missing for kitchen island, no outlet boxes installed NEC 210.52 4. Electrical panel is not installed properly must be secured in the wall per manufacter specs 5. Interior load bearing wall top plate has been cut in half to run exhaust vent for range, Will need a engineered letter showing an approved repair 6. Nail plate missing for range vent must extend 2'' below top plate FBCR M1308.2 7. Tub must be filled to over flow FBCR P2503.7 8. SGD and garage entry door require solid blocking gaps over 1/4'' around frames FBCR 609.1 | |||
| ALL ROUGH | 09/17/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. No E-cals on site FBC 107.3.1 2. Product approval sheet does not match windows installed a revision is required 3. Knee wall missing for kitchen island, no outlet boxes installed NEC 210.52 4. Electrical panel is not installed properly must be secured in the wall per manufacter specs 5. Interior load bearing wall top plate has been cut in half to run exhaust vent for range, Will need a engineered letter showing an approved repair 6. Nail plate missing for range vent must extend 2'' below top plate FBCR M1308.2 7. Tub must be filled to over flow FBCR P2503.7 8. SGD and garage entry door require solid blocking gaps over 1/4'' around frames FBCR 609.1 | |||
| LATH/BRICK/ WATER BARRIER | 09/11/2024 | APPROVED | KSANDOE |
| Note: Inspector Notes from Inspection 2460 8/19/2024 - PREVIOUS INSPECTION NOTES 08-19-2024 Roof sheathing only approved. Contractor can procedd with roof shingle installation at own risk. Approved drawings not on site. 08-20-2024 1.Engineering packet not on site. 2. A-4.1 indicates 2 z 12 at front entry. Lintels installed. Please submit a revision and have approved revisin on site prior to next inspection 3. Please indicate all load bearing walls. Check at next inspection. Contractor can proceed at own risk. Roof sheathing is approved. | |||
| ELECTRIC TEMP POLE | 09/11/2024 | APPROVED - AS NOTED | KSANDOE |
| Note: Release Power | |||
| ELECTRIC-TUG | 09/10/2024 | CANCELLED BY INSPECTOR | KSANDOE |
| Note: Cannot install Temporary Underground Power on overhead service. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/20/2024 | APPROVED - AS NOTED | AGAETANO |
| Note: 8/19/2024 - PREVIOUS INSPECTION NOTES 08-19-2024 Roof sheathing only approved. Contractor can procedd with roof shingle installation at own risk. Approved drawings not on site. 08-20-2024 1.Engineering packet not on site. 2. A-4.1 indicates 2 z 12 at front entry. Lintels installed. Please submit a revision and have approved revisin on site prior to next inspection 3. Please indicate all load bearing walls. Check at next inspection. Contractor can proceed at own risk. Roof sheathing is approved. | |||
| ROOF VALLEY & METAL | 08/19/2024 | APPROVED | AGAETANO |
| WALL SHEATHING | 08/19/2024 | APPROVED | AGAETANO |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 08/19/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 08-19-2024 Roof sheathing only approved. Contractor can procedd with roof shingle installation at own risk. Approved drawings not on site. | |||
| TIE BEAM / LINTEL | 07/30/2024 | APPROVED | AGAETANO |
| Note: 7/29/2024 - PREVIOUS INSPECTION NOTES 07-29-2024 Approved drawings not on site. | |||
| TIE BEAM / LINTEL | 07/29/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 07-29-2024 Approved drawings not on site. | |||
| FOUND SURVEY APPROVED (OFFICE) | 07/01/2024 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 06/24/2024 | APPROVED | KSANDOE |
| Note: 6/18/2024 - PREVIOUS INSPECTION NOTES 6/18/24: Previously listed items 2, 3, 4 and 5 remain unresolved. Previous items: 1). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations so it will need to remain on site property out of swale). 2). Garage footer is only 10" deep for about 6ft in the middle. 3). Back lanai footer has a mound of dirt under the rebar & plastic that needs to be removed. 4). Interior load bearing footer is not 16" wide at the bottom as required on plans. 5). Silt fence still needs to be repaired. 6/11/2024 - PREVIOUS INSPECTION NOTES 6/11/24: NOT READY! 1). No portable toilet as required. TOILET FACILITIES FOR WORKERS 311.1 General. Toilet facilities shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Construction worker toilet facilities of the nonsewer type shall conform to ANSI Z4.3. 2). Garage footers do not consistently meet plan requirements for depth & width. 3). Back footer before lanai does not match plan requirements. 4). Interior load bearing footer does not match plan requirements. 5). Silt fence needs to be repaired & maintained. FBC 3307.1 6). Need to clean up trash and overgrowth to make site safe for inspection. 7). Pipe sleeve at interior bearing wall footer does not extend fully through the footer. | |||
| MONOLITHIC SLAB | 06/18/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 6/18/24: Previously listed items 2, 3, 4 and 5 remain unresolved. Previous items: 1). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. This will need to be complete before any further inspections will be approved. (This is also part of the Storm Water - Illicit Discharge Prevention Regulations so it will need to remain on site property out of swale). 2). Garage footer is only 10" deep for about 6ft in the middle. 3). Back lanai footer has a mound of dirt under the rebar & plastic that needs to be removed. 4). Interior load bearing footer is not 16" wide at the bottom as required on plans. 5). Silt fence still needs to be repaired. 6/11/2024 - PREVIOUS INSPECTION NOTES 6/11/24: NOT READY! 1). No portable toilet as required. TOILET FACILITIES FOR WORKERS 311.1 General. Toilet facilities shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Construction worker toilet facilities of the nonsewer type shall conform to ANSI Z4.3. 2). Garage footers do not consistently meet plan requirements for depth & width. 3). Back footer before lanai does not match plan requirements. 4). Interior load bearing footer does not match plan requirements. 5). Silt fence needs to be repaired & maintained. FBC 3307.1 6). Need to clean up trash and overgrowth to make site safe for inspection. 7). Pipe sleeve at interior bearing wall footer does not extend fully through the footer. | |||
| MONOLITHIC SLAB | 06/11/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 6/11/24: NOT READY! 1). No portable toilet as required. TOILET FACILITIES FOR WORKERS 311.1 General. Toilet facilities shall be provided for construction workers and such facilities shall be maintained in a sanitary condition. Construction worker toilet facilities of the nonsewer type shall conform to ANSI Z4.3. 2). Garage footers do not consistently meet plan requirements for depth & width. 3). Back footer before lanai does not match plan requirements. 4). Interior load bearing footer does not match plan requirements. 5). Silt fence needs to be repaired & maintained. FBC 3307.1 6). Need to clean up trash and overgrowth to make site safe for inspection. 7). Pipe sleeve at interior bearing wall footer does not extend fully through the footer. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 02/16/2024 | APPROVED | MGIBSON |
| ROW - DRAINAGE | 10/13/2023 | Disapproved -FEE REQUIRED | FSLADISH |
| Note: 10/13/23 STILL NEED TO GET PORTA POTTY OUT THE ROW AND ONTO YOUR SITE. MAKE SURE TO KEEP SWALE TO GRADE AND MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. I WILL BE BACK FOR REINSPECTION FOR COMPLIANCE ON 10/16/23. _______________________________________________________________________________________________________________________ 10/11/2023 - PREVIOUS INSPECTION NOTES 10/11/23 STILL NEED TO GET PORTA POTTY OUT THE ROW AND ONTO YOUR SITE. MAKE SURE TO KEEP SWALE TO GRADE AND MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. I WILL BE BACK FOR REINSPECTION FOR COMPLIANCE ON 10/13/23 __________________________________________________________________________________________________________________________ 10/6/2023 - PREVIOUS INSPECTION NOTES 10/06/23 SWALE IS STILL OPEN AT THIS TIME, IT WILL NEED TO BE MAINTAINED DAILY UNTIL AND AFTER TEMPORARY PIPE IS INSTALLED. WILL BE BACK ON 10/11/23 FOR REINSPECTION. NEED TO REMOVE THE PORTA POTTY FROM SWALE AND PUT IT ON YOUR SITE. _________________________________________________________________________________________________________________________ 10/5/2023 - PREVIOUS INSPECTION NOTES 10/05/23 BUILDER CALLED AND LEFT A VOICE MAIL STATING THAT THEY ARE ON SCHEDULE TO HAVE TEMPORARY CULVERT PIPE INSTALLED. AT THIS TIME THE SWALE IS GRADED. I WILL SCEDULE A DRAINAGE INSPECTION FOR TOMORROW. NO FEE __________________________________________________________________________________________________________________________ rjg. Caller at 181 says the new build is blocking the drainage of the swale. Port o potty right in the middle with no temp culvert. Please inspect. | |||
| ROW - DRAINAGE | 10/11/2023 | Disapproved - NO FEE | FSLADISH |
| Note: 10/11/23 STILL NEED TO GET PORTA POTTY OUT THE ROW AND ONTO YOUR SITE. MAKE SURE TO KEEP SWALE TO GRADE AND MAINTAINED THROUGHOUT THE CONSTRUCTION PROCESS. I WILL BE BACK FOR REINSPECTION FOR COMPLIANCE ON 10/13/23 __________________________________________________________________________________________________________________________ 10/6/2023 - PREVIOUS INSPECTION NOTES 10/06/23 SWALE IS STILL OPEN AT THIS TIME, IT WILL NEED TO BE MAINTAINED DAILY UNTIL AND AFTER TEMPORARY PIPE IS INSTALLED. WILL BE BACK ON 10/11/23 FOR REINSPECTION. NEED TO REMOVE THE PORTA POTTY FROM SWALE AND PUT IT ON YOUR SITE. _________________________________________________________________________________________________________________________ 10/5/2023 - PREVIOUS INSPECTION NOTES 10/05/23 BUILDER CALLED AND LEFT A VOICE MAIL STATING THAT THEY ARE ON SCHEDULE TO HAVE TEMPORARY CULVERT PIPE INSTALLED. AT THIS TIME THE SWALE IS GRADED. I WILL SCEDULE A DRAINAGE INSPECTION FOR TOMORROW. NO FEE __________________________________________________________________________________________________________________________ rjg. Caller at 181 says the new build is blocking the drainage of the swale. Port o potty right in the middle with no temp culvert. Please inspect. | |||
| ROW - DRAINAGE | 10/06/2023 | PARTIALLY APPROVED | FSLADISH |
| Note: 10/06/23 SWALE IS STILL OPEN AT THIS TIME, IT WILL NEED TO BE MAINTAINED DAILY UNTIL AND AFTER TEMPORARY PIPE IS INSTALLED. WILL BE BACK ON 10/11/23 FOR REINSPECTION. NEED TO REMOVE THE PORTA POTTY FROM SWALE AND PUT IT ON YOUR SITE. _________________________________________________________________________________________________________________________ 10/5/2023 - PREVIOUS INSPECTION NOTES 10/05/23 BUILDER CALLED AND LEFT A VOICE MAIL STATING THAT THEY ARE ON SCHEDULE TO HAVE TEMPORARY CULVERT PIPE INSTALLED. AT THIS TIME THE SWALE IS GRADED. I WILL SCEDULE A DRAINAGE INSPECTION FOR TOMORROW. NO FEE __________________________________________________________________________________________________________________________ rjg. Caller at 181 says the new build is blocking the drainage of the swale. Port o potty right in the middle with no temp culvert. Please inspect. | |||
| ROW - DRAINAGE | 10/05/2023 | PARTIALLY APPROVED | FSLADISH |
| Note: 10/05/23 BUILDER CALLED AND LEFT A VOICE MAIL STATING THAT THEY ARE ON SCHEDULE TO HAVE TEMPORARY CULVERT PIPE INSTALLED. AT THIS TIME THE SWALE IS GRADED. I WILL SCEDULE A DRAINAGE INSPECTION FOR TOMORROW. NO FEE __________________________________________________________________________________________________________________________ rjg. Caller at 181 says the new build is blocking the drainage of the swale. Port o potty right in the middle with no temp culvert. Please inspect. | |||
| WATER METER INSTALLATION REQUEST | 09/20/2023 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 02/11/2025 | 02/12/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/14/2025 | 01/15/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 01/14/2025 | 01/15/2025 |
| Note: Released By: LEVI SALYERDS - (386)986-2326 - LSALYERDS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/14/2025 | 01/14/2025 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 10/01/2024 | 10/01/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 09/25/2024 | 09/30/2024 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Highlight changed numbers or only submit numbers tha are changing. | |||
| BLD | COMPLETE | 09/18/2024 | 09/23/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/11/2024 | 09/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/13/2024 | 08/16/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 07/01/2024 | 07/01/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 07/01/2024 | 07/01/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/17/2023 | 08/20/2023 |
| Note: Released By: JPI | |||
| BADMIN | INFORMATION | 08/17/2023 | 08/17/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please rename your file correctly. See the document submittal requirements on the permit portal page for direction. | |||
| BADMIN | INFORMATION | 08/17/2023 | 08/17/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM Please rename your files in accordance with the document submittal requirements located on the permitting portal page. | |||
| BLD | HOLD | 08/09/2023 | 08/14/2023 |
| Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet. | |||
| CUSVC | COMPLETE | 08/09/2023 | 08/14/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 08/09/2023 | 08/15/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/09/2023 | 08/09/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 08/09/2023 | 08/14/2023 |
| LOCATE | COMPLETE | 08/09/2023 | 08/11/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/09/2023 | 08/14/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/09/2023 | 08/09/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/09/2023 | 08/10/2023 |
| Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 08/09/2023 | 08/15/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 08/09/2023 | 09/22/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| PLAN REVIEW - REVISION | ¤32.50 | 02/20/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/20/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/20/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/20/2025 |
| SW ENG - INSPECTION 20 | ¤20.00 | 02/20/2025 |
| SW ENG INSPECTION 80 | ¤80.00 | 08/21/2023 |
| SW ENG PRE APRON | ¤30.00 | 08/21/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 08/21/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 08/21/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 08/21/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 08/21/2023 |
| SEWER CREDIT | (¤1,466.00) | 08/21/2023 |
| SEWER INSPECTION | ¤25.00 | 08/21/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 08/21/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 08/21/2023 |
| SITE PLAN 30 | ¤30.00 | 08/21/2023 |
| CONNECTION FEES | ¤1,166.26 | 08/21/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 08/21/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 08/21/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 08/21/2023 |
| IMPACT FEE FIRE | ¤420.52 | 08/21/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 08/21/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 08/21/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 08/21/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 08/21/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 08/21/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 08/21/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 08/21/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 08/21/2023 |
| SURCHARGE FS 533.721 | ¤5.45 | 08/21/2023 |
| SURCHARGE - FS 468.631 | ¤8.17 | 08/21/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 08/21/2023 |
| WATER- TURN ON | ¤25.00 | 08/21/2023 |
| ADJUSTMENT 50% | (¤544.50) | 08/21/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/21/2023 |
| INSPECTION - RESIDENTIAL | ¤825.00 | 08/21/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤234.00 | 08/21/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,294.25 |