I want to search for...
Permit #2023080655
Permit Details
Status: COED
| Parcel Id: 07-11-31-7026-00530-0040 |
| CONDITIONED SPACE: 2000 sqft |
| GARAGE: 476 sqft |
| OPENED PORCH (WITH ROOF) : 197 sqft |
| OPENED PORCH (WITH ROOF) : 144 sqft |
| Total Square Footage: 2817 sqft |
| Block: 00530 |
| Subdivision: 2153 - SECTION 26-PINE GROVE |
| Job Phone: 912-258-2201 |
| Location Address: 7 PINE BUSH LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 08/24/2023 |
| NOC: RECORDED |
| Applicant name: JAMES FUCETOLA III |
| Owner: PALM COAST COMMUNITIES LLC |
|
Address PO BOX 22547 ST SIMONS ISLAND, GA 31522 |
| Lot: 0040 |
| Contracted Stated Job Value: ¤215,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
PALM COAST COMMUNITIES LLC
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 22547 PALM COAST, FL 32164 |
CBC1262878 (Exp: 08/31/2026) | 321-501-4617 |
Sub Contractors
WILLIAM FRANK DUDLEY JR.
| Status | Location Address | State License Number | Phone |
| ACTIVE |
P.O. BOX 978 Bunnell, FL 32110 |
EC0003177 (Exp: 08/31/2026) | (386)437-3068 |
OLEG BELINSKIY
| Status | Location Address | State License Number | Phone |
| ACTIVE |
19 PINE CIRCLE DRIVE19 PALM COAST, FL 32167 |
CCC1325974 (Exp: 08/31/2026) | 386-263-7906 |
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
JEFFREY TROY SABAKA
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
2191 DEERWOOD ACRES DR ST AUGUSTINE, FL 32084 |
CFC1427439 (Exp: 08/31/2026) | 904-838-2218 | 904-819-0965 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 03/20/2024 | FINAL APPROVED | KSANDOE |
| Note: 3/18/2024 - PREVIOUS INSPECTION NOTES 1. Form boards must be removed around ODU pad 2. ODU is required to be a min of 3'' off grade 3. All garage wall and ceiling penitrations must be sealed 4. E-cals on site do not have stamp from Building Dept. showing they have been approved | |||
| BLD - BUILDING FINAL | 03/18/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Form boards must be removed around ODU pad 2. ODU is required to be a min of 3'' off grade 3. All garage wall and ceiling penitrations must be sealed 4. E-cals on site do not have stamp from Building Dept. showing they have been approved | |||
| U -UTILITY RESIDENTIAL FINAL | 03/18/2024 | FINAL APPROVED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 has potable irr with PVB -no cross connection | |||
| ROW - FINAL APRON (AFTER POUR) | 03/15/2024 | APPROVED | EMADISON |
| Note: ** ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/15/2024 | APPROVED | EMADISON |
| Note: | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 03/15/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. | |||
| ROW - STORMWATER FINAL | 03/15/2024 | APPROVED | EMADISON |
| Note: ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 03/07/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) THE ADJACENT LOT TO THE RIGHT OF THIS PROPERTY IS NOT VACANT NEED TO CORRECT THAT IT IS IMPROVED AND NEED TO GET THE FFE OF THE STRUCTURE. 2) THE IMPROVED LOT BEHIND THIS LOT ALSO NEEDS THE FFE OF THE STRUCTURE. SEC.300.01 B3 Finished Floor Elevation (FFE) of the living area of improved structures on adjacent lots. | |||
| U-CROSS CONNECTION | 03/05/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: has potable irr with PVB -no cross connection | |||
| ROW- PRE-APRON (PRE-POUR) | 01/23/2024 | APPROVED | PFLANAGAN |
| Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ELECTRIC - EARLY POWER | 01/16/2024 | APPROVED | RMARTIN |
| U - SEWER TIE IN | 12/21/2023 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 12/11/2023 | APPROVED | BVITALE |
| INSULATION | 12/11/2023 | APPROVED | KSANDOE |
| ALL ROUGH | 12/05/2023 | APPROVED | KSANDOE |
| Note: 12/1/2023 - PREVIOUS INSPECTION NOTES Need building plans and energy calcs on site for inspector use | |||
| ALL ROUGH | 12/01/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Need building plans and energy calcs on site for inspector use | |||
| LATH/BRICK/ WATER BARRIER | 12/01/2023 | APPROVED | KSANDOE |
| WALL SHEATHING | 11/16/2023 | APPROVED | KSANDOE |
| Note: 11/14/2023 - PREVIOUS INSPECTION NOTES 11/14/23: Wall sheathing is not nailed as required by detail on plan page 5. (4"OC all edges/6" OC field). 11/13/2023 - PREVIOUS INSPECTION NOTES 11/13/23: Incomplete plans in box for inspection. FBC 107.3.1. Only truss plans in box. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/16/2023 | APPROVED | KSANDOE |
| ROOF VALLEY & METAL | 11/16/2023 | APPROVED | KSANDOE |
| WALL SHEATHING | 11/14/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 11/14/23: Wall sheathing is not nailed as required by detail on plan page 5. (4"OC all edges/6" OC field). 11/13/2023 - PREVIOUS INSPECTION NOTES 11/13/23: Incomplete plans in box for inspection. FBC 107.3.1. Only truss plans in box. | |||
| ROOF SHEATHING | 11/13/2023 | APPROVED - AS NOTED | RSIMS |
| Note: 11/13/23: Incomplete plans in box for inspection. FBC 107.3.1 Nailing pattern confirmed on electronic plan documents. Approved | |||
| WALL SHEATHING | 11/13/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 11/13/23: Incomplete plans in box for inspection. FBC 107.3.1. Only truss plans in box. | |||
| TIE BEAM / LINTEL | 11/07/2023 | APPROVED | KSANDOE |
| Note: 11/6/2023 - PREVIOUS INSPECTION NOTES 11/6/23- Via text 10/27/2023 - PREVIOUS INSPECTION NOTES Plans call for precast concrete sills. | |||
| TIE BEAM / LINTEL | 11/06/2023 | CANCELLED BY APPLICANT | JSTEWART |
| Note: 11/6/23- Via text 10/27/2023 - PREVIOUS INSPECTION NOTES Plans call for precast concrete sills. | |||
| FOUND SURVEY APPROVED (OFFICE) | 11/06/2023 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 10/27/2023 | Disapproved - NO FEE | KSANDOE |
| Note: Plans call for precast concrete sills. | |||
| MONOLITHIC SLAB | 10/17/2023 | APPROVED | KSANDOE |
| Note: 10/13/2023 - PREVIOUS INSPECTION NOTES 10/13/23: Please mark ufer ground with tape or paint. ** All footer areas have dirt wash in & standing water. 10/10/2023 - PREVIOUS INSPECTION NOTES 1. Ufer has not been installed. 2. Slab compaction test has not been posted. | |||
| MONOLITHIC SLAB | 10/13/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 10/13/23: Please mark ufer ground with tape or paint. ** All footer areas have dirt wash in & standing water. 10/10/2023 - PREVIOUS INSPECTION NOTES 1. Ufer has not been installed. 2. Slab compaction test has not been posted. | |||
| MONOLITHIC SLAB | 10/10/2023 | Disapproved - NO FEE | JWALKER |
| Note: 1. Ufer has not been installed. 2. Slab compaction test has not been posted. | |||
| GRAVITY SEWER TEST | 10/06/2023 | APPROVED | MGIBSON |
| Note: 10/4/2023 - PREVIOUS INSPECTION NOTES 5ft head test failed | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 10/06/2023 | APPROVED | MGIBSON |
| Note: 10/4/2023 - PREVIOUS INSPECTION NOTES 5FT head test failed | |||
| GRAVITY SEWER TEST | 10/04/2023 | Disapproved - NO FEE | KSANDOE |
| Note: 5ft head test failed | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 10/04/2023 | Disapproved - NO FEE | KSANDOE |
| Note: 5FT head test failed | |||
| WATER METER INSTALLATION REQUEST | 09/19/2023 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 11/08/2023 | 11/13/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 11/06/2023 | 11/06/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 11/06/2023 | 11/06/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/21/2023 | 08/21/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/14/2023 | 08/20/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 08/14/2023 | 08/16/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 08/14/2023 | 08/15/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/14/2023 | 08/14/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 08/14/2023 | 08/16/2023 |
| LOCATE | COMPLETE | 08/14/2023 | 08/15/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/14/2023 | 08/16/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/14/2023 | 08/14/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/14/2023 | 08/14/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Landscape plan states two different sod types please only specify the one you are using Tree type on the front right not specified and the back right states two different tree types. Please correct the landscape plan and only state the ones you are using | |||
| BADMIN | COMPLETE | 08/14/2023 | 08/21/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 08/14/2023 | 09/22/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/20/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/20/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 03/20/2024 |
| CONNECTION FEES | ¤1,166.26 | 08/24/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 08/24/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 08/24/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 08/24/2023 |
| IMPACT FEE FIRE | ¤420.52 | 08/24/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 08/24/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 08/24/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 08/24/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 08/24/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 08/24/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 08/24/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 08/24/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 08/24/2023 |
| SURCHARGE FS 533.721 | ¤4.65 | 08/24/2023 |
| SURCHARGE - FS 468.631 | ¤6.98 | 08/24/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 08/24/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 08/24/2023 |
| SW ENG PRE APRON | ¤30.00 | 08/24/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 08/24/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 08/24/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 08/24/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 08/24/2023 |
| SEWER CREDIT | (¤3,008.47) | 08/24/2023 |
| SEWER INSPECTION | ¤25.00 | 08/24/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 08/24/2023 |
| WATER CREDIT | (¤34.63) | 08/24/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 08/24/2023 |
| SITE PLAN 30 | ¤30.00 | 08/24/2023 |
| WATER- TURN ON | ¤25.00 | 08/24/2023 |
| ADJUSTMENT 50% | (¤465.08) | 08/24/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 08/24/2023 |
| INSPECTION - RESIDENTIAL | ¤701.25 | 08/24/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤198.90 | 08/24/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤18,443.23 |