Permit #2023080846

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7063-00140-0020
Block: 00140
Subdivision: 2174 - SECTION 63-ZEBULAHS TRAIL
Job Phone: 727-287-8540
Location Address: 5 ZONAL CT
Type: WD - WINDOWS/DOORS
Issue Date: 08/24/2023
NOC: RECORDED
Applicant name: THOMAS LIPPERT
Owner: SPARKS WILLIAM C JR & CONSTANCE A H&W

Address

5 ZONAL CT

PALM COAST, FL 32164

Lot: 0020
Contracted Stated Job Value: ¤10,356.00
Job Description: windows like for like
Type: CN

Contractor

HOME PERFORMANCE ALLIANCE, INC
Status Location Address Mailing Address State License Number Phone
INACTIVE

11399 16TH CT N

ST PETERSBURG, FL 33716

STE 100

ST PETERSBURG, FL 33716

CGC1508826 (Exp: 08/31/2026) 727-538-4140

Inspection History

Type Request Date Result Inspector
FINAL - BUILDING MISC 01/11/2024 FINAL APPROVED BTAYLOR
Note: New inspection due to canceled inspection 1/8/2024 - PREVIOUS INSPECTION NOTES 1/8/24: Arrived at 10:55 - no answer. Please schedule when access is available. 11/6/2023 - PREVIOUS INSPECTION NOTES 11/6/23: Inspection Stopped! Installation instructions are cut off. Please provide complete installation instructions for re-inspection. Also, this door is smaller than the original door resulting in exposure of the pressure treated buck and installation of a furring strip. Please remove furring strip and install pressure treated lumber due to contact with cement products. You will need to tape seal the perimeter and install stucco stop prior to patching removed stucco. Adding a lath/brick/water barrier inspection to check for proper sealing as noted above. This inspection will need to be performed prior to Final Inspection. 11/2/2023 - PREVIOUS INSPECTION NOTES 11-2-23 1. Arrived at 9:08 no answer.
FINAL - BUILDING MISC 01/10/2024 CANCELLED BY APPLICANT WEB
Note: 1/8/2024 - PREVIOUS INSPECTION NOTES 1/8/24: Arrived at 10:55 - no answer. Please schedule when access is available. 11/6/2023 - PREVIOUS INSPECTION NOTES 11/6/23: Inspection Stopped! Installation instructions are cut off. Please provide complete installation instructions for re-inspection. Also, this door is smaller than the original door resulting in exposure of the pressure treated buck and installation of a furring strip. Please remove furring strip and install pressure treated lumber due to contact with cement products. You will need to tape seal the perimeter and install stucco stop prior to patching removed stucco. Adding a lath/brick/water barrier inspection to check for proper sealing as noted above. This inspection will need to be performed prior to Final Inspection. 11/2/2023 - PREVIOUS INSPECTION NOTES 11-2-23 1. Arrived at 9:08 no answer.
FINAL - BUILDING MISC 01/08/2024 Disapproved - NO FEE RSIMS
Note: 1/8/24: Arrived at 10:55 - no answer. Please schedule when access is available. 11/6/2023 - PREVIOUS INSPECTION NOTES 11/6/23: Inspection Stopped! Installation instructions are cut off. Please provide complete installation instructions for re-inspection. Also, this door is smaller than the original door resulting in exposure of the pressure treated buck and installation of a furring strip. Please remove furring strip and install pressure treated lumber due to contact with cement products. You will need to tape seal the perimeter and install stucco stop prior to patching removed stucco. Adding a lath/brick/water barrier inspection to check for proper sealing as noted above. This inspection will need to be performed prior to Final Inspection. 11/2/2023 - PREVIOUS INSPECTION NOTES 11-2-23 1. Arrived at 9:08 no answer.
LATH/BRICK/ WATER BARRIER 12/21/2023 APPROVED RSIMS
Note: 11/6/23: This inspection added to inspect for pressure treated lumber, tape seal around perimeter along with stucco stop.
FINAL - BUILDING MISC 11/06/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/6/23: Inspection Stopped! Installation instructions are cut off. Please provide complete installation instructions for re-inspection. Also, this door is smaller than the original door resulting in exposure of the pressure treated buck and installation of a furring strip. Please remove furring strip and install pressure treated lumber due to contact with cement products. You will need to tape seal the perimeter and install stucco stop prior to patching removed stucco. Adding a lath/brick/water barrier inspection to check for proper sealing as noted above. This inspection will need to be performed prior to Final Inspection. 11/2/2023 - PREVIOUS INSPECTION NOTES 11-2-23 1. Arrived at 9:08 no answer.
FINAL - BUILDING MISC 11/02/2023 Disapproved - NO FEE BTAYLOR
Note: 11-2-23 1. Arrived at 9:08 no answer.
FINAL - BUILDING MISC 11/01/2023 CANCELLED BY APPLICANT WEB

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 12/20/2023
SURCHARGE FS 533.721 ¤2.00 08/24/2023
SURCHARGE - FS 468.631 ¤2.00 08/24/2023
ADJUSTMENT 50% (¤45.00) 08/24/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/24/2023
INSPECTION - RESIDENTIAL ¤60.00 08/24/2023
Fees Total Due: ¤0.00 Total Paid: ¤89.00