Permit #2023080912

Permit Details

Status: COED

Parcel Id: 07-11-31-7034-01100-0030
CONDITIONED SPACE: 1900 sqft
GARAGE: 630 sqft
OPENED PORCH (WITH ROOF) : 362 sqft
OPENED PORCH (WITH ROOF) : 71 sqft
Total Square Footage: 2963 sqft
Block: 01100
Subdivision: 2165 - SECTION 34-EASTHAMPTON
Job Phone: 386-931-4289
Location Address: 96 ERIC DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/26/2023
NOC: RECORDED
Applicant name: RICHARD M. ANDERSON
Owner: ANDERSON THOMAS R % LEWERS & ASSOC

Address

8 CARLOS COURT

PALM COAST, FL 32137

Lot: 0030
Contracted Stated Job Value: ¤300,000.00
Job Description: SINGLE FAMILY RESIDENCE
Type: CN

Contractor

PALM WEST HOME BUILDERS, INC.
Status Location Address State License Number Phone Fax
ACTIVE

2 Florida Park Drive North

Palm Coast, FL 32137

CRC054633 (Exp: 08/31/2026) (386) 445-7001 (386)446-5941

Sub Contractors

JOSEPH C WRIGHT
Status Location Address Mailing Address State License Number Phone Fax
ACTIVE

15 HARGROVE LANE

PALM COAST, FL 32137

UNIT 3 D

PALM COAST, FL 32137

EC13003278 (Exp: 08/31/2026) 386-447-9644 386-447-9633
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
CHRISTOPHER DANIEL FULTON
Status Location Address Mailing Address State License Number Phone
ACTIVE

2 MARKET PLACE

PALM COAST, FL 32137

UNIT D

PALM COAST, FL 32137

CCC1331939 (Exp: 08/31/2026) 386-445-7945
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488

Inspection History

Type Request Date Result Inspector
ROW - STORMWATER FINAL 10/02/2024 Disapproved - NO FEE FSLADISH
Note: 10/2/24 YOU HAVE NOT COMPLETED THE HOT PATCH WHERE IT HAS BEEN OUTLINED IN WHITE ON THE PREVIOUS INSPECTION TO REPAIR ON THE EDWARD DRIVE SIDE. THIS NEEDS TO BE COMPLETED AS NOTED BEFORE ROW FINAL PASSAGE. Road Damage must be seen before construction starts Sec 300.01 E2/ Sec 300.03 F1 Sec 300.01 E2 A pre-lot clearing inspection for road damage may be requested, if necessary, by calling the ESWD. If an inspection has not been requested the builder will be responsible for all road damage at the time of the final inspection. AS A ONE TIME COURTESY I WILL NOT FEE YOU TODAY. PLEASE MAKE CORRECTION BEFORE RESUBMITTING FOR ROW FINAL. 9/26/2024 - PREVIOUS INSPECTION NOTES 9/26/24 WILL NEED TO HAVE HOT PATCH COMPLETED BEFORE ROW FINAL PASSAGE. WILL NOT EE YOU TODAY AS I WAS ALREADY HERE FOR YOUR AFTERPOUR INSPECTION.
ROW - STORMWATER FINAL 10/02/2024 APPROVED - AS NOTED FSLADISH
Note: 10/2/24 ACCIDENTALLY RESULTED BASED ON THE WRONG ADDRESS FOR ROAD REPAIR. DRIVEWAY HOT PATCH HAS BEEN COMPLETED AT THIS TIME. HAS A SMALL LIP BUT LESS THAN THE THE MAXIMUM ALLOWED. APPROVING AS NOTED. _______________________________________________________________________________________________________________________ 10/2/2024 - PREVIOUS INSPECTION NOTES 10/2/24 YOU HAVE NOT COMPLETED THE HOT PATCH WHERE IT HAS BEEN OUTLINED IN WHITE TO REPAIR ON THE EDWARD DRIVE SIDE. THIS NEEDS TO BE COMPLETED AS NOTED BEFORE ROW FINAL PASSAGE. Road Damage must be seen before construction starts Sec 300.01 E2/ Sec 300.03 F1 Sec 300.01 E2 A pre-lot clearing inspection for road damage may be requested, if necessary, by calling the ESWD. If an inspection has not been requested the builder will be responsible for all road damage at the time of the final inspection. 9/26/2024 - PREVIOUS INSPECTION NOTES 9/26/24 WILL NEED TO HAVE HOT PATCH COMPLETED BEFORE ROW FINAL PASSAGE. WILL NOT EE YOU TODAY AS I WAS ALREADY HERE FOR YOUR AFTERPOUR INSPECTION.
U -UTILITY RESIDENTIAL FINAL 10/02/2024 FINAL APPROVED BWRIGHT
Note: 9/26/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LFITZGERALD 9/26/2024 10:57:56 AM *** lower sewer clean out
BLD - BUILDING FINAL 09/30/2024 APPROVED CVANSTRAHLEN
Note: 9/30/24 Approved (CV) 9/26/2024 - PREVIOUS INSPECTION NOTES 9/26/24 do not have power in garage - (CV)
U-CROSS CONNECTION 09/26/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 9/26/2024 10:57:28 AM *** no irrigation-no cross connection-NOTE HAS BIRRIGATION METER THAT IS NOT GOING TO BE USED SO TOLD rICH-BUILDING SUPERTO CONTACT CITY FORNREMOVAL SO THAT EW H/O does not encur an unneccessary charge every month
ROW - FINAL APRON (AFTER POUR) 09/26/2024 APPROVED FSLADISH
Note: 9/26/24 PIPE ELEVATION IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. WILL NEED TO HAVE HOT PATCH COMPLETED BEFORE ROW FINAL.
U - SEWER TIE IN 09/26/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2095 THIS WAS A VIRTUAL INSPECTION
BLD - BUILDING FINAL 09/26/2024 Disapproved - NO FEE CVANSTRAHLEN
Note: 9/26/24 do not have power in garage - (CV)
U -UTILITY RESIDENTIAL FINAL 09/26/2024 Disapproved -FEE REQUIRED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 9/26/2024 10:57:56 AM *** lower sewer clean out
ROW - STORMWATER FINAL 09/26/2024 Disapproved - NO FEE FSLADISH
Note: 9/26/24 WILL NEED TO HAVE HOT PATCH COMPLETED BEFORE ROW FINAL PASSAGE. WILL NOT EE YOU TODAY AS I WAS ALREADY HERE FOR YOUR AFTERPOUR INSPECTION.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/25/2024 APPROVED FSLADISH
ROW FIELD SURVEY /GRADING CERTIFICATION 09/25/2024 APPROVED FSLADISH
Note: 9/25/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ROW- PRE-APRON (PRE-POUR) 08/30/2024 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ALL ROUGH 08/22/2024 APPROVED AGAETANO
Note: 8/21/24: This inspection added for the Kitchen range exhaust piping only so that it can be covered with the finished shroud.
GRAVITY SEWER TEST 08/02/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
SEWER TIE IN 08/02/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
TUB SET 07/30/2024 APPROVED MGIBSON
ROW - DRAINAGE 07/30/2024 Disapproved - NO FEE TPOLACEK
Note: 07/30/24 TPOLACEK*** BUILDER MUST INSTALL A SILT FENCE AROUND PROPERTY, REMOVE PORTA POTTY FROM SWALE AND OPEN UP TEMP PIPE AS IT IS CRUSHED AND NOT FUNCTIONING. NEXT INSPECTION THURSDAY 08/01/24
ROW - DRAINAGE 07/01/2024 CANCELLED BY INSPECTOR FSLADISH
Note: 7/30/2024 - PREVIOUS INSPECTION NOTES 07/30/24 TPOLACEK*** BUILDER MUST INSTALL A SILT FENCE AROUND PROPERTY, REMOVE PORTA POTTY FROM SWALE AND OPEN UP TEMP PIPE AS IT IS CRUSHED AND NOT FUNCTIONING. NEXT INSPECTION THURSDAY 08/01/24
PEP TANK INSTALLATION REQUEST 06/11/2024 APPROVED CBOWERMASTER
ELECTRIC - EARLY POWER 06/05/2024 APPROVED AGAETANO
Note: 6/4/2024 - PREVIOUS INSPECTION NOTES
ELECTRIC - EARLY POWER 06/04/2024 CANCELLED BY APPLICANT AGAETANO
INSULATION 04/12/2024 APPROVED RSIMS
Note: Inspector Notes from Inspection 2420 4/5/24: Approved as noted. Check at Insulation. 1). Kitchen exhaust pipe needs to be sealed at all joints of adjustable elbow as required and please add 3 screws evenly spaced at all pipe connections. FBC 3307.1 2). Hole in slab at soaking tub needs to be repaired with cement as required. Inspector Notes from Inspection 2425 4/3/24: Approved as noted. Check at All Rough. * Need to add an anchor at the top between two top anchors on every window to meet manufacturer's spacing requirements shown on installation documents. Inspector Notes from Inspection 2320 4/1/24: Approved as noted to keep the project moving. Revision still needs to be Approved. Inspector Notes from Inspection 2425 3/27/24: * A revision for the different windows installed (29511.1) than what appears on the original product approval document (15576.1) needs to be submitted to & approved by the City prior to All Rough inspection. Please correct the fixed window and door numbers as needed also.
ALL ROUGH 04/05/2024 APPROVED - AS NOTED RSIMS
Note: 4/5/24: Approved as noted. Check at Insulation. 1). Kitchen exhaust pipe needs to be sealed at all joints of adjustable elbow as required and please add 3 screws evenly spaced at all pipe connections. FBC 3307.1 2). Hole in slab at soaking tub needs to be repaired with cement as required. Inspector Notes from Inspection 2425 4/3/24: Approved as noted. Check at All Rough. * Need to add an anchor at the top between two top anchors on every window to meet manufacturer's spacing requirements shown on installation documents. Inspector Notes from Inspection 2320 4/1/24: Approved as noted to keep the project moving. Revision still needs to be Approved. Inspector Notes from Inspection 2425 3/27/24: * A revision for the different windows installed (29511.1) than what appears on the original product approval document (15576.1) needs to be submitted to & approved by the City prior to All Rough inspection. Please correct the fixed window and door numbers as needed also.
WINDOW NAILING 04/03/2024 APPROVED - AS NOTED RSIMS
Note: 4/3/24: Approved as noted. Check at All Rough. * Need to add an anchor at the top between two top anchors on every window to meet manufacturer's spacing requirements shown on installation documents. Inspector Notes from Inspection 2320 4/1/24: Approved as noted to keep the project moving. Revision still needs to be Approved. Inspector Notes from Inspection 2425 3/27/24: * A revision for the different windows installed (29511.1) than what appears on the original product approval document (15576.1) needs to be submitted to & approved by the City prior to All Rough inspection. Please correct the fixed window and door numbers as needed also.
LATH/BRICK/ WATER BARRIER 04/01/2024 APPROVED - AS NOTED RSIMS
Note: 4/1/24: Approved as noted to keep the project moving. Revision still needs to be Approved. Inspector Notes from Inspection 2425 3/27/24: * A revision for the different windows installed (29511.1) than what appears on the original product approval document (15576.1) needs to be submitted to & approved by the City prior to All Rough inspection. Please correct the fixed window and door numbers as needed also.
WINDOW NAILING 03/27/2024 APPROVED - AS NOTED RSIMS
Note: 3/27/24: * A revision for the different windows installed (29511.1) than what appears on the original product approval document (15576.1) needs to be submitted to & approved by the City prior to All Rough inspection. Please correct the fixed window and door numbers as needed also.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/26/2024 APPROVED RSIMS
Note: Inspector Notes from Inspection 2460 3/18/24: Approved pending submittal to & approval by the City for the truss repair as noted at the previous inspection on 2/26/24: >Item 2). Need revision for Engineers approved repaired to Truss A8 broken at two areas. 3/11/2024 - PREVIOUS INSPECTION NOTES
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/18/2024 APPROVED - AS NOTED RSIMS
Note: 3/18/24: Approved pending submittal to & approval by the City for the truss repair as noted at the previous inspection on 2/26/24: >Item 2). Need revision for Engineers approved repaired to Truss A8 broken at two areas. 3/11/2024 - PREVIOUS INSPECTION NOTES
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/11/2024 CANCELLED BY APPLICANT BTAYLOR
ROOF VALLEY & METAL 03/11/2024 APPROVED BTAYLOR
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/26/2024 APPROVED - AS NOTED RSIMS
Note: 2/26/24: Roof sheathing & down cell checked and approved. Deficiencies must be resolved prior to next Inspection. Truss Engineering: 1). Truss V1, V2 (entry overframing) & V5, V6 (at interior garage wall overframing) are missing straps as required. 2). Need revision for Engineers approved repaired to Truss A8 broken at two areas. Tie Down: 3). Need revision for the different tie-down (all - thread rod) used at garage wall.
FOUND SURVEY APPROVED (OFFICE) 02/23/2024 APPROVED TBAKER
FOOTER 02/01/2024 APPROVED RSIMS
Note: 2/1/24: Inspected added footer for Bearing point of girder truss behind Master bath sinks. Verified footer at 5ft x 16" x 20" deep with #5 rebar - three across & 8 long ways with (2) #5 rebar embedded into existing concrete on the short ends. Included 6" PVC sleeve for plumbing.
TIE BEAM / LINTEL 02/01/2024 APPROVED RSIMS
MONOLITHIC SLAB 01/11/2024 APPROVED RSIMS
Note: 1/10/2024 - PREVIOUS INSPECTION NOTES 1/10/24: Cancelled by Applicant via phone at @ 09:28. 1/9/2024 - PREVIOUS INSPECTION NOTES 1/9/24: 1). Left side drain line through footer is missing a sleeve or relieving arch. (Sleeve ends were buried under dirt on both sides along with the majority of the pipe being covered. Exposed now & approved). 2). Per detail 7F on page 6. Requires 3 rebar on the short side. Only 2 installed. Note: Foundation plan does not show any information detailing which footer requirements listed on Plan page 6 are to be followed so you would need to follow all of them unless noted otherwise.
MONOLITHIC SLAB 01/10/2024 CANCELLED BY APPLICANT RSIMS
Note: 1/10/24: Cancelled by Applicant via phone at @ 09:28. 1/9/2024 - PREVIOUS INSPECTION NOTES 1/9/24: 1). Left side drain line through footer is missing a sleeve or relieving arch. (Sleeve ends were buried under dirt on both sides along with the majority of the pipe being covered. Exposed now & approved). 2). Per detail 7F on page 6. Requires 3 rebar on the short side. Only 2 installed. Note: Foundation plan does not show any information detailing which footer requirements listed on Plan page 6 are to be followed so you would need to follow all of them unless noted otherwise.
MONOLITHIC SLAB 01/09/2024 Disapproved - NO FEE RSIMS
Note: 1/9/24: 1). Left side drain line through footer is missing a sleeve or relieving arch. 2). Per detail 7F on page 6. Requires 3 rebar on the short side. Only 2 installed. Note: Foundation plan does not show any information detailing which footer requirements listed on Plan page 6 are to be followed so you would need to follow all of them unless noted otherwise.
PLUMBING 1ST ROUGH UNDERGROUND 12/21/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 12/14/2023 APPROVED BVITALE

Review History

Department Status Date In Date Out
BLD COMPLETE 03/27/2024 04/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/19/2024 03/25/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 03/13/2024 03/18/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 02/28/2024 03/04/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 02/23/2024 02/23/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 02/23/2024 02/23/2024
Note: Released By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM
BLD COMPLETE 01/31/2024 02/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 09/21/2023 09/21/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 09/14/2023 09/15/2023
Note: Released By: JPI
ELEC COMPLETE 09/14/2023 09/15/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH HOLD 09/14/2023 09/15/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 2. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition (Third Request)
SW1 COMPLETE 09/14/2023 09/20/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON COMPLETE 08/28/2023 08/29/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD HOLD 08/28/2023 08/30/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
ELEC HOLD 08/28/2023 08/31/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need combo alarms outside of bedrooms. FRC 2020 314 and 315 2. Submit manufacture specs of generator 3. Submit a riser diagram showing all wire sizes and breaker sizes including the generator. 4. Submit manufacture specs of the reccess can lights with a min of a 1 hour fire rating in the garage. FRC 2020 302.5 5. Need light and switch by exterior door in garage. NEC 2017 210.70 2nd REQUEST
MECH HOLD 08/28/2023 08/31/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show R30 Insulation in attic. Energy calcs say R19. revise to match 2. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition (Second Request)
ENGIN1 COMPLETE 08/28/2023 08/29/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 HOLD 08/28/2023 09/07/2023
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM SITE PLAN TO BLURRY TO READ
CUSVC COMPLETE 08/18/2023 08/21/2023
Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com
BADMIN COMPLETE 08/17/2023 08/21/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 08/17/2023 08/20/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
CUSVC HOLD 08/17/2023 08/17/2023
Note: Held By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM Please complete and upload a utility application
ELEC HOLD 08/17/2023 08/21/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need combo alarms outside of bedrooms. FRC 2020 314 and 315 2. Submit manufacture specs of generator 3. Submit a riser diagram showing all wire sizes and breaker sizes including the generator. 4. Submit manufacture specs of the reccess can lights with a min of a 1 hour fire rating in the garage. FRC 2020 302.5 5. Need light and switch by exterior door in garage. NEC 2017 210.70
ENGIN1 COMPLETE 08/17/2023 08/17/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 08/17/2023 08/21/2023
LOCATE COMPLETE 08/17/2023 08/18/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 08/17/2023 08/21/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show R30 Insulation in attic. Energy calcs say R19. revise to match 2. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition
SW1 COMPLETE 08/17/2023 08/25/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 08/17/2023 08/18/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM AC pad location missing on site plan/survey
SWALE COMPLETE 08/17/2023 09/26/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
PLAN REVIEW - REVISION ¤32.50 10/03/2024
REINSPECTION FEE ¤40.00 10/03/2024
SW ENG - INSPECTION 20 ¤20.00 10/03/2024
SW ENG - INSPECTION 20 ¤20.00 10/03/2024
SW ENG INSPECTION 80 ¤80.00 09/26/2023
SW ENG PRE APRON ¤30.00 09/26/2023
SW ENG - REVIEW 20 ¤20.00 09/26/2023
SW ENG RES REVIEW 200 ¤200.00 09/26/2023
TRANS IMPACT FEE ADMIN ¤54.36 09/26/2023
TRANS IMPACT FEE ADMIN (¤54.36) 09/26/2023
SEWER CREDIT (¤850.00) 09/26/2023
SEWER INSPECTION ¤25.00 09/26/2023
SEWER CAPITAL FACILITY ¤5,344.82 09/26/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 09/26/2023
SITE PLAN 30 ¤30.00 09/26/2023
SURCHARGE FS 533.721 ¤5.45 09/26/2023
SURCHARGE - FS 468.631 ¤8.17 09/26/2023
SW ENG - FOUNDATION SURVEY ¤20.00 09/26/2023
WATER-METER ¤505.39 09/26/2023
WATER- TURN ON ¤25.00 09/26/2023
WATER- TURN ON ¤25.00 09/26/2023
ADJUSTMENT 50% (¤544.50) 09/26/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/26/2023
INSPECTION - RESIDENTIAL ¤825.00 09/26/2023
PLAN REVIEW - RESIDENTIAL ¤234.00 09/26/2023
CONNECTION FEES ¤1,166.26 09/26/2023
FIRE IMPACT FEE ADMIN ¤12.62 09/26/2023
FIRE IMPACT FEE ADMIN (¤12.62) 09/26/2023
FC IMPACT FEE EMS ¤62.00 09/26/2023
IMPACT FEE FIRE ¤420.52 09/26/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 09/26/2023
FC IMPACT FEE LIBRARY ¤268.00 09/26/2023
IMPACT FEE PARKS ¤1,769.15 09/26/2023
IMPACT FEE SCHOOL ¤5,450.00 09/26/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 09/26/2023
WATER -IRRIGATION INSPECTION ¤25.00 09/26/2023
WATER -IRRIGATION INSPECTION ¤25.00 09/26/2023
PARKS IMPACT FEE ADMIN ¤53.07 09/26/2023
PARKS IMPACT FEE ADMIN (¤53.07) 09/26/2023
Fees Total Due: ¤0.00 Total Paid: ¤21,265.64