I want to search for...
Permit #2023081120
Permit Details
Status: COED
| Parcel Id: 07-11-31-7017-00050-0030 |
| CONDITIONED SPACE: 2052 sqft |
| GARAGE: 407 sqft |
| OPENED PORCH (WITH ROOF) : 16 sqft |
| Total Square Footage: 2475 sqft |
| Block: 00050 |
| Subdivision: 2129 - SECTION 17-BELLE TERRE |
| Job Phone: 904-268-7730 |
| Location Address: 6 BOSTON LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/12/2023 |
| NOC: RECORDED |
| Applicant name: SCOTT CHRISTIAN HOWARD |
| Owner: FOCUS HOMES LLC |
|
Address 5220 SHAD RD JACKSONVILLE, FL 32257 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤195,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
FOCUS HOMES LLC OF FLORIDA
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
5220 SHAD RD JACKSONVILLE, FL 32257 |
# 202 JACKSONVILLE, FL 32257 |
CRC1332443 (Exp: 08/31/2026) | 904-268-7730 |
Sub Contractors
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
DANIEL GREGORY PUGLISI
| Status | Location Address | State License Number | Phone |
| INACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
EC13011195 (Exp: 08/31/2024) | 407-302-7800 |
CLINTON J HULSLANDER SR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CFC1430632 (Exp: 08/31/2026) | 407-321-0064 | 407-688-8534 |
RONALD KEVIN HAUPT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CAC058534 (Exp: 08/31/2026) | 407-321-0064 |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 02/14/2024 | FINAL APPROVED | JSTEWART |
| Note: 2/13/2024 - PREVIOUS INSPECTION NOTES 2/13/24- 1. 1 of 3 locking caps not installed and locked (laying on pad). FBC - M1411.8 2. spare bath shower mixing valve no preassure at the hot setting. P2705.1General. 3. Please seal garage ceiling cat 5's penetration. R402.4 4. Please seal dryer exhaust duct (unless dryer is installed.M1502.4.7 Exhaust duct required. | |||
| U-CROSS CONNECTION | 02/14/2024 | APPROVED | DHANEY |
| U -UTILITY RESIDENTIAL FINAL | 02/14/2024 | FINAL APPROVED | DHANEY |
| Note: 2/12/2024 - PREVIOUS INSPECTION NOTES Sewer clean out needs trimmed to ground level . | |||
| U -UTILITY RESIDENTIAL FINAL | 02/13/2024 | Disapproved - NO FEE | DHANEY |
| Note: Sewer clean out needs trimmed to ground level . | |||
| BLD - BUILDING FINAL | 02/13/2024 | Disapproved - NO FEE | JSTEWART |
| Note: 2/13/24- 1. 1 of 3 locking caps not installed and locked (laying on pad). FBC - M1411.8 2. spare bath shower mixing valve no preassure at the hot setting. P2705.1General. 3. Please seal garage ceiling cat 5's penetration. R402.4 4. Please seal dryer exhaust duct (unless dryer is installed.M1502.4.7 Exhaust duct required. | |||
| ROW - FINAL APRON (AFTER POUR) | 02/12/2024 | APPROVED | TPOLACEK |
| Note: 02/12/24 PIPE IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/12/2024 | APPROVED | TPOLACEK |
| Note: 02/12/24 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW - STORMWATER FINAL | 02/12/2024 | APPROVED | TPOLACEK |
| Note: 02/12/24 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/09/2024 | APPROVED | TPOLACEK |
| Note: 02/09/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. | |||
| U - SEWER TIE IN | 02/09/2024 | CANCELLED BY APPLICANT | WEB |
| Note: 1/5/2024 - PREVIOUS INSPECTION NOTES | |||
| U - SEWER TIE IN | 02/07/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: New inspection due to canceled inspection 1/5/2024 - PREVIOUS INSPECTION NOTES THIS WAS A VIRTUAL INSPECTION | |||
| ROW- PRE-APRON (PRE-POUR) | 01/24/2024 | APPROVED | TPOLACEK |
| Note: 01.24.24 AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. | |||
| ELECTRIC - EARLY POWER | 01/11/2024 | APPROVED | JSTEWART |
| Note: 1/10/2024 - PREVIOUS INSPECTION NOTES 1/10/24- 230.62 Service Equipment....(A) Enclosed. Energized parts shall be enclosed so that they will not be exposed to accidental contact or shall be guarded as in 230.62(B). 1. Breaker panel needs to be securely enclosed with aproved cover. | |||
| ELECTRIC - EARLY POWER | 01/10/2024 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 1/10/24- 230.62 Service Equipment....(A) Enclosed. Energized parts shall be enclosed so that they will not be exposed to accidental contact or shall be guarded as in 230.62(B). 1. Breaker panel needs to be securely enclosed with aproved cover. | |||
| U - SEWER TIE IN | 01/05/2024 | CANCELLED BY APPLICANT | MGIBSON |
| U - SEWER TIE IN | 01/04/2024 | CANCELLED BY APPLICANT | WEB |
| INSULATION | 12/01/2023 | APPROVED | FWILLIS |
| Note: 11/30/2023 - PREVIOUS INSPECTION NOTES | |||
| INSULATION | 11/30/2023 | CANCELLED BY APPLICANT | FWILLIS |
| LATH/BRICK/ WATER BARRIER | 11/30/2023 | APPROVED | FWILLIS |
| Note: 11/29/2023 - PREVIOUS INSPECTION NOTES 11/29/23 1. Multiple places where tap does not cover joints 100% (garage door opening,front of home) 2. Wall sheathng is missing at front entry close to soffit 11/27/2023 - PREVIOUS INSPECTION NOTES 11/27/23- Please cut shims and install water barrier (flashing) around the Margins of the front entry door. R703.4 (1) Flashing Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall finish or to the water-resistive barrier..... | |||
| ALL ROUGH | 11/29/2023 | APPROVED - AS NOTED | KSANDOE |
| Note: Revised product approval has not been approved. Bathroom exhaust ducts need to be supported every 4ft 4 HJC26 found to have no nailing 11/27/2023 - PREVIOUS INSPECTION NOTES 11/27/23- 1. Please obtain revision of Product aproval #'s for windows installed. 2. House service line is not installed into meter box, and conduit not attached to wall. 3. Please install Plumbing NP at spare bath Lav horizontal drain...P2603.2.1 . 4. Please seal roof penetration at Dryer duct., FBCM.603.1. 5. Please seal Both Exhaust fan duct at roof Penetration. FBCM.603.1 | |||
| LATH/BRICK/ WATER BARRIER | 11/29/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 11/29/23 1. Multiple places where tap does not cover joints 100% (garage door opening,front of home) 2. Wall sheathng is missing at front entry close to soffit 11/27/2023 - PREVIOUS INSPECTION NOTES 11/27/23- Please cut shims and install water barrier (flashing) around the Margins of the front entry door. R703.4 (1) Flashing Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall finish or to the water-resistive barrier..... | |||
| ALL ROUGH | 11/27/2023 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 11/27/23- 1. Please obtain revision of Product aproval #'s for windows installed. 2. House service line is not installed into meter box, and conduit not attached to wall. 3. Please install Plumbing NP at spare bath Lav horizontal drain...P2603.2.1 . 4. Please seal roof penetration at Dryer duct., FBCM.603.1. 5. Please seal Both Exhaust fan duct at roof Penetration. FBCM.603.1 | |||
| LATH/BRICK/ WATER BARRIER | 11/27/2023 | Disapproved - NO FEE | JSTEWART |
| Note: 11/27/23- Please cut shims and install water barrier (flashing) around the Margins of the front entry door. R703.4 (1) Flashing Exterior window and door openings. Flashing at exterior window and door openings shall extend to the surface of the exterior wall finish or to the water-resistive barrier..... | |||
| ROOF VALLEY & METAL | 11/16/2023 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/13/2023 | APPROVED | JSTEWART |
| Note: 11/9/2023 - PREVIOUS INSPECTION NOTES 11/9/23: Need dumpster on site and trash piles cleaned up (to make site safe) prior to scheduling any additional inspections. 1). 5 areas of loose roof sheathing. (marked on wall below) check all. 2). Truss 08 first on left does not have the proper web bracing/engineering. (too short). 3). Installed trusses do not match the truss layout plan. (marked on small prints). Will need correction or revision submitted to the City. 4). Headers not attached per plan detail. (highlighted). | |||
| ELECTRIC-TUG | 11/13/2023 | APPROVED | JSTEWART |
| Note: 11/13/23- Authorize release of email to FPL @ 9:08a. | |||
| WALL SHEATHING | 11/09/2023 | APPROVED | RSIMS |
| Note: New inspection due to canceled inspection 11/7/2023 - PREVIOUS INSPECTION NOTES 11/7/23- Multiple locations Missing nails per specs, (marked on walls with orange paint). Please check all wall sheathing for pulled shiners with No replacement. 10/30/2023 - PREVIOUS INSPECTION NOTES 10/30/23-via text | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/09/2023 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/09/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 11/9/23: Need dumpster on site and trash piles cleaned up (to make site safe) prior to scheduling any additional inspections. 1). 5 areas of loose roof sheathing. (marked on wall below) check all. 2). Truss 08 first on left does not have the proper web bracing/engineering. (too short). 3). Installed trusses do not match the truss layout plan. (marked on small prints). Will need correction or revision submitted to the City. 4). Headers not attached per plan detail. (highlighted). | |||
| WALL SHEATHING | 11/08/2023 | CANCELLED BY APPLICANT | WEB |
| Note: 11/7/2023 - PREVIOUS INSPECTION NOTES 11/7/23- Multiple locations Missing nails per specs, (marked on walls with orange paint). Please check all wall sheathing for pulled shiners with No replacement. 10/30/2023 - PREVIOUS INSPECTION NOTES 10/30/23-via text | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/08/2023 | CANCELLED BY APPLICANT | WEB |
| WALL SHEATHING | 11/07/2023 | Disapproved -FEE REQUIRED | JSTEWART |
| Note: 11/7/23- Multiple locations Missing nails per specs, (marked on walls with orange paint). Please check all wall sheathing for pulled shiners with No replacement. 10/30/2023 - PREVIOUS INSPECTION NOTES 10/30/23-via text | |||
| ROOF SHEATHING | 11/07/2023 | APPROVED | JSTEWART |
| WALL SHEATHING | 10/30/2023 | CANCELLED BY APPLICANT | JSTEWART |
| Note: 10/30/23-via text | |||
| MONOLITHIC SLAB | 10/17/2023 | APPROVED | FWILLIS |
| FOUND SURVEY APPROVED (OFFICE) | 10/13/2023 | APPROVED | TBAKER |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/11/2023 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 10/11/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 09/21/2023 | APPROVED | CBOWERMASTER |
| Note: 9/19/2023 7:20:36 AM- PREVIOUS INSPECTION NOTES still clearing | |||
| WATER METER INSTALLATION REQUEST | 09/18/2023 | Disapproved -FEE REQUIRED | CBOWERMASTER |
| Note: still clearing |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 11/27/2023 | 11/29/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 11/15/2023 | 11/20/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/12/2023 | 10/13/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/12/2023 | 10/12/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/29/2023 | 08/29/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/29/2023 | 08/29/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/29/2023 | 09/07/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/21/2023 | 08/23/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 08/21/2023 | 08/24/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 08/21/2023 | 08/22/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/21/2023 | 08/21/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 08/21/2023 | 08/23/2023 |
| LOCATE | COMPLETE | 08/21/2023 | 08/24/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/21/2023 | 08/23/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/21/2023 | 08/28/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/21/2023 | 08/22/2023 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Site plan missing all setbacks. Also, please add the 5' platted easement to the site plan on this lot - not the neighboring lot. | |||
| BADMIN | COMPLETE | 08/21/2023 | 08/23/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 08/21/2023 | 09/28/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/13/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/13/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/13/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/13/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 02/13/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 02/13/2024 |
| REINSPECTION FEE | ¤40.00 | 02/13/2024 |
| SURCHARGE FS 533.721 | ¤4.47 | 09/12/2023 |
| SURCHARGE - FS 468.631 | ¤6.71 | 09/12/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/12/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 09/12/2023 |
| SW ENG PRE APRON | ¤30.00 | 09/12/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/12/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/12/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 09/12/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 09/12/2023 |
| SEWER CREDIT | (¤1,147.00) | 09/12/2023 |
| SEWER INSPECTION | ¤25.00 | 09/12/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 09/12/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 09/12/2023 |
| SITE PLAN 30 | ¤30.00 | 09/12/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 09/12/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 09/12/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 09/12/2023 |
| IMPACT FEE FIRE | ¤420.52 | 09/12/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 09/12/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 09/12/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 09/12/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 09/12/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 09/12/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/12/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 09/12/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 09/12/2023 |
| CONNECTION FEES | ¤1,166.26 | 09/12/2023 |
| WATER- TURN ON | ¤25.00 | 09/12/2023 |
| ADJUSTMENT 50% | (¤447.43) | 09/12/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/12/2023 |
| INSPECTION - RESIDENTIAL | ¤673.75 | 09/12/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤191.10 | 09/12/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,441.23 |