I want to search for...
Permit #2023081164
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7027-00560-0140 |
| Block: 00560 |
| Subdivision: 2128 - SECTION 27-WYNNFIELD |
| Job Phone: 904-568-2498 |
| Location Address: 29 WOOD ARBOR LN |
| Type: ME - MECHANICAL |
| Issue Date: 12/11/2023 |
| NOC: Unknown |
| Applicant name: TIMUR ISPARYAN |
| Owner: ATLANTIC RE HOLDING LLC |
|
Address 46 N PARK CIRCLEACE PALM COAST, FL 32137 |
| Lot: 0140 |
| Contracted Stated Job Value: ¤14,900.00 |
| Job Description: hvac |
| Type: CN |
Contractor
AVALON HEATING AND AIR LLC
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
3665 SPRINK PARK ROAD JACKSONVILLE , FL 32207 |
CMC1249968 (Exp: 08/31/2026) | 904-245-1818 | 904-337-1910 |
Inspection History
| Type | Request Date | Result | Inspector |
| HVAC FINAL | 12/19/2023 | FINAL APPROVED | MKRASKI |
| HVAC FINAL | 12/15/2023 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 12/14/23: * Breaker panel is not accessible from the house & the garage is locked. Cannot verify breaker sizes as previously noted. 12/12/2023 - PREVIOUS INSPECTION NOTES 1. AHRI paperwork does not matched equipment installed 2. AHU disconnect door must open 90 degrees 3. Unable to locate electrical panel to check proper breaker sizes | |||
| HVAC FINAL | 12/12/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. AHRI paperwork does not matched equipment installed 2. AHU disconnect door must open 90 degrees 3. Unable to locate electrical panel to check proper breaker sizes |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 12/18/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 12/11/2023 |
| SURCHARGE - FS 468.631 | ¤2.00 | 12/11/2023 |
| ADJUSTMENT 50% | (¤45.00) | 12/11/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 12/11/2023 |
| INSPECTION - MECHANICAL | ¤60.00 | 12/11/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤89.00 |