I want to search for...

Permit #2023081331

Permit Details

Status: COED

Parcel Id: 07-11-31-7064-00090-0140
Block: 00090
Subdivision: 2178 - SECTION 64-LAGUNA FOREST
Job Phone: 904-813-0124
Location Address: 8 LLACH CT
Type: RF - REROOF
Issue Date: 08/25/2023
NOC: RECORDED
Applicant name: JORDAN R WEBB
Owner: ZDEBSKIY IVAN

Address

23 WHITE HOUSE DR

PALM COAST, FL 32164

Lot: 0140
Contracted Stated Job Value: ¤18,400.00
Job Description: Reroof
Type: CN

Contractor

REDTAIL ROOFING LLC
Status Location Address State License Number Phone
ACTIVE

7643 GATE PARKWAY 104-177

JACKSONVILLE, FL 32256

CCC1331300 (Exp: 08/31/2026) 904-813-0124

Inspection History

Type Request Date Result Inspector
ROOF FINAL 11/22/2023 Disapproved - NO FEE BTAYLOR
Note: 11/20/2023 - PREVIOUS INSPECTION NOTES 11-20-23 Inspection performed via on-roof inspection as the first level roof and upper level roof had a walkable attachement (drone was not needed). The upper level ridge is missing a row of shingles on one side and the ridge caps have been placed offset in order to try and cover the section that is missing a row of shingles. Need to place the missing row of shingles at the ridge on the upper (highest) portion of the roof or provide manufactureer installation instruction showing magtching the missing row and offset redge cap. 10/23/2023 - PREVIOUS INSPECTION NOTES 10-23-23 1. Need to schedule drone inspection.Being forwarded to get scheduled for drone in spection. 11-22-23 1. Need to schedule drone inspection.Being forwarded to get scheduled for drone in spection.
ROOF FINAL 11/22/2023 FINAL APPROVED BTAYLOR
Note: 11/22/2023 - PREVIOUS INSPECTION NOTES 11/20/2023 - PREVIOUS INSPECTION NOTES 11-20-23 Inspection performed via on-roof inspection as the first level roof and upper level roof had a walkable attachement (drone was not needed). The upper level ridge is missing a row of shingles on one side and the ridge caps have been placed offset in order to try and cover the section that is missing a row of shingles. Need to place the missing row of shingles at the ridge on the upper (highest) portion of the roof or provide manufactureer installation instruction showing magtching the missing row and offset redge cap. 10/23/2023 - PREVIOUS INSPECTION NOTES 10-23-23 1. Need to schedule drone inspection.Being forwarded to get scheduled for drone in spection. 11-22-23 1. Need to schedule drone inspection.Being forwarded to get scheduled for drone in spection.
ROOF FINAL 11/20/2023 Disapproved - NO FEE LMILLER
Note: 11-20-23 Inspection performed via on-roof inspection as the first level roof and upper level roof had a walkable attachement (drone was not needed). The upper level ridge is missing a row of shingles on one side and the ridge caps have been placed offset in order to try and cover the section that is missing a row of shingles. Need to place the missing row of shingles at the ridge on the upper (highest) portion of the roof or provide manufactureer installation instruction showing magtching the missing row and offset redge cap. 10/23/2023 - PREVIOUS INSPECTION NOTES 10-23-23 1. Need to schedule drone inspection.Being forwarded to get scheduled for drone in spection.
ROOF FINAL 10/23/2023 Disapproved - NO FEE BTAYLOR
Note: 10-23-23 1. Need to schedule drone inspection.Being forwarded to get scheduled for drone in spection.
ROOF AFFIDAVIT 10/20/2023 APPROVED MRAMOS
ROOF IN PROGRESS- MIDROOF 10/19/2023 APPROVED RSIMS
Note: 10/18/2023 - PREVIOUS INSPECTION NOTES 10-18-23 1. Not ready.
ROOF IN PROGRESS- MIDROOF 10/18/2023 Disapproved - NO FEE BTAYLOR
Note: 10-18-23 1. Not ready.

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 50% (¤45.00) 08/25/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/25/2023
INSPECTION - RESIDENTIAL ¤60.00 08/25/2023
SURCHARGE FS 533.721 ¤2.00 08/25/2023
SURCHARGE - FS 468.631 ¤2.00 08/25/2023
Fees Total Due: ¤0.00 Total Paid: ¤49.00