I want to search for...

Permit #2023081333

Permit Details

Status: COED

Parcel Id: 29-10-31-5540-00000-0820
GARAGE: 816 sqft
GARAGE: 538 sqft
CONDITIONED SPACE: 3964 sqft
OPENED PORCH (WITH ROOF) : 685 sqft
OPENED PORCH (WITH ROOF) : 121 sqft
Total Square Footage: 6124 sqft
Block: 00000
Subdivision: 1005 - SANCTUARY SUBDIVISION
Job Phone: (386)445-9393
Location Address: 46 SABAL BEND
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 08/24/2023
NOC: RECORDED
Applicant name: ANTONIO JR AMARAL
Owner: AMARAL PAULO M & ROSELINDA R H&W

Address

155 SAND SPRING RD

MORRISTOWN, NJ 07960

Lot: 0820
Contracted Stated Job Value: ¤365,000.00
Job Description: SINGLE FAMILY RESIDENCE # 2022060241
Type: CN
Original Permit #: 2022060241

Contractor

AMARAL HOMES & POOLS, LLC
Status Location Address State License Number Phone
ACTIVE

13 Utility Drive

PALM COAST, FL 32137

CBC058062 (Exp: 08/31/2026) (386)445-9393

Sub Contractors

JEFFREY ADAM MCGREGOR
Status Location Address State License Number Phone Fax
ACTIVE

1312 YORKTOWN STREET

DELAND , FL 32724

EC13005662 (Exp: 08/31/2026) 386-736-7475 386-785-1503
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
ANTONIO AMARAL JR
Status Location Address State License Number
ACTIVE

1370 PALM HARBOR PKWY

PALM COAST, FL 32137

CCC058004 (Exp: 08/31/2026)
JEFFREY ADAM MCGREGOR
Status Location Address State License Number Phone Fax
ACTIVE

1312 YORKTOWN STREET

DELAND , FL 32724

EC13005662 (Exp: 08/31/2026) 386-736-7475 386-785-1503
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
ANTONIO AMARAL JR
Status Location Address State License Number
ACTIVE

1370 PALM HARBOR PKWY

PALM COAST, FL 32137

CCC058004 (Exp: 08/31/2026)
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 03/26/2025 FINAL APPROVED HCAMACHO
BLD - BUILDING FINAL 03/25/2025 Disapproved - NO FEE HCAMACHO
Note: 1. Need locking breakers on ovens and cooktop NEC 422.31 &110.25 2. Need GFCI in pantry, and finish triming.NEC 210.8 3. Need attic access in the house due to Spary foam. No access to the house from Garage. FBCR 807.1 4. Trim romex Wire in Lanai. NEC 110.27(A)
ROW - STORMWATER FINAL 02/26/2025 APPROVED - AS NOTED PFLANAGAN
Note: NEED TO REMOVE SILT FENCE IN THE BACK ALONG SEAWALL AND PICK UP ALL TRASH ON LOT. PASSING AS NOTED THAT THIS WILL BE TAKEN CARE OF.
U -UTILITY RESIDENTIAL FINAL 02/26/2025 FINAL APPROVED BWRIGHT
Note: Inspector Notes from Inspection 9035 well irr-no cross connection
ROW - FINAL APRON (AFTER POUR) 02/26/2025 APPROVED PFLANAGAN
Note: At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection.
ELEVATION CERTIFICATE-FINAL APPROVAL 02/25/2025 APPROVED JMYERS
U-CROSS CONNECTION 02/13/2025 APPROVED - AS NOTED LFITZGERALD
Note: well irr-no cross connection
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/06/2025 APPROVED - AS NOTED PFLANAGAN
Note: THE FINAL SURVEY DOESN'T SHOW THE BERM AND DRAINAGE IN THE BACK ACROSSED THE ENTIRE BACK YARD PASSING AS NOTED THAT THE DRAINAGE WILL WORK CORRECT IN THE FIELD
ROW FIELD SURVEY /GRADING CERTIFICATION 02/06/2025 APPROVED PFLANAGAN
ROW - DRAINAGE 02/06/2025 APPROVED PFLANAGAN
Note: 4/28/2023 - PREVIOUS INSPECTION NOTES ** 04/28/23 BUILDER NEEDS TO INSTALL A SILT FENCE ON LEFT SIDE FROM PROPERTY LINE TO RIGHT SIDE PROPERTY LINE ** FOLLOW UP INSPECTION 05/05/23 __________________________________________________________________________________________________________________________ rjg. Concerned residence. Please check for silt fence compliance.
ROW- PRE-APRON (PRE-POUR) 11/05/2024 APPROVED PFLANAGAN
Note: READY TO LAY PAVERS ------------------------------------------------------------- 10/21/2024 - PREVIOUS INSPECTION NOTES ** 10/21/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED
ELECTRIC - EARLY POWER 11/05/2024 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2200 7/18/2024 - PREVIOUS INSPECTION NOTES The Electrical riser installed does not match the electrical rise shown on the plan page E1. Please submit a revision to the building department for the change. Plans call for 300 amp service. Contractor installed. 400 amp 8-8-24 1. Emailed FPL at 9:13.
ROW- PAVER RESTRAINTS 10/21/2024 APPROVED EMADISON
Note: ** 10/21/24 READY TO POUR PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE
ROW- PRE-APRON (PRE-POUR) 10/21/2024 PARTIALLY APPROVED EMADISON
Note: ** 10/21/24 READY TO POUR APRON AND PAVER RESTRAINTS ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL ** SCHEDULE NEXT PRE-POUR ONCE PAVER BASE HAS BEEN SPREAD AND COMPACTED ** DO NOT SET PAVERS UNTIL NEXT PRE-POUR HAS BEEN APPROVED
LATH/BRICK/ WATER BARRIER 08/23/2024 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 8/14/2024 2:51:11 PM *** 1. Please install Nail guard in laundry in left corner of washer water supply. 2. Please install nail guards at master bath shower wall for water supplys (multiple TP). 3. Please install anchors at head of front entry double door to florida product approval code. will check at insulation 7/2/2024 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection Inspector Notes from Inspection 2460 06/18/24 Inspection administratively approved by CBO based on Architect's inspection letter. 5/20/2024 - PREVIOUS INSPECTION NOTES 1. The truss engineering packets provided are out of order and have gotten wet. The one packet in the job box is from 15 serpent trl. Please have a full set of approved engineered drawing onsite and in order. Ensure the cover page with the listed pages is included. 2. Items 2 and 4 listed below from the 4/23 inspection have also not been corrected. 4/23/2024 - PREVIOUS INSPECTION NOTES 1. Multiple trusses are missing engineering. A01 through A27 have been inspected A06, 7, 22, 23,24,25 and 27 are missing engineering. Truss engineering inspection was stopped at the B trusses. The rest of the trusses starting at the B's still need to be inspected. 2. Max truss spacing is 2' o.c. two areas at the right side front and garage trusses have been spaced greater than 2' for the attic access. Please have the engineer submitt a detail showing the needed over framing in the two areas. 3. Multiple girder trusses call for VGT hold downs that have not been installed. locations circled on the plans. 4. Roof sheating was unable to be inspected. Roof tile has been installed. Inspection has been stopped. The contractor will need to contact the building department for further instruction on how to proceed. 12/19/2023 - PREVIOUS INSPECTION NOTES 132-19-2023 1. Truss layout is not readable. Please have a readable layout on site. 2. Please provide an anchor schedule. 3. Bearing walls are not indicated.
INSULATION 08/23/2024 APPROVED FWILLIS
Note: Inspector Notes from Inspection 2420 *** NOTES ADDED BY JSTEWART 8/14/2024 2:51:11 PM *** 1. Please install Nail guard in laundry in left corner of washer water supply. 2. Please install nail guards at master bath shower wall for water supplys (multiple TP). 3. Please install anchors at head of front entry double door to florida product approval code. will check at insulation 7/2/2024 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection Inspector Notes from Inspection 2460 06/18/24 Inspection administratively approved by CBO based on Architect's inspection letter. 5/20/2024 - PREVIOUS INSPECTION NOTES 1. The truss engineering packets provided are out of order and have gotten wet. The one packet in the job box is from 15 serpent trl. Please have a full set of approved engineered drawing onsite and in order. Ensure the cover page with the listed pages is included. 2. Items 2 and 4 listed below from the 4/23 inspection have also not been corrected. 4/23/2024 - PREVIOUS INSPECTION NOTES 1. Multiple trusses are missing engineering. A01 through A27 have been inspected A06, 7, 22, 23,24,25 and 27 are missing engineering. Truss engineering inspection was stopped at the B trusses. The rest of the trusses starting at the B's still need to be inspected. 2. Max truss spacing is 2' o.c. two areas at the right side front and garage trusses have been spaced greater than 2' for the attic access. Please have the engineer submitt a detail showing the needed over framing in the two areas. 3. Multiple girder trusses call for VGT hold downs that have not been installed. locations circled on the plans. 4. Roof sheating was unable to be inspected. Roof tile has been installed. Inspection has been stopped. The contractor will need to contact the building department for further instruction on how to proceed. 12/19/2023 - PREVIOUS INSPECTION NOTES 132-19-2023 1. Truss layout is not readable. Please have a readable layout on site. 2. Please provide an anchor schedule. 3. Bearing walls are not indicated.
ALL ROUGH 08/14/2024 APPROVED - AS NOTED JSTEWART
Note: *** NOTES ADDED BY JSTEWART 8/14/2024 2:51:11 PM *** 1. Please install Nail guard in laundry in left corner of washer water supply. 2. Please install nail guards at master bath shower wall for water supplys (multiple TP). 3. Please install anchors at head of front entry double door to florida product approval code. will check at insulation 7/2/2024 - PREVIOUS INSPECTION NOTES New inspection due to canceled inspection Inspector Notes from Inspection 2460 06/18/24 Inspection administratively approved by CBO based on Architect's inspection letter. 5/20/2024 - PREVIOUS INSPECTION NOTES 1. The truss engineering packets provided are out of order and have gotten wet. The one packet in the job box is from 15 serpent trl. Please have a full set of approved engineered drawing onsite and in order. Ensure the cover page with the listed pages is included. 2. Items 2 and 4 listed below from the 4/23 inspection have also not been corrected. 4/23/2024 - PREVIOUS INSPECTION NOTES 1. Multiple trusses are missing engineering. A01 through A27 have been inspected A06, 7, 22, 23,24,25 and 27 are missing engineering. Truss engineering inspection was stopped at the B trusses. The rest of the trusses starting at the B's still need to be inspected. 2. Max truss spacing is 2' o.c. two areas at the right side front and garage trusses have been spaced greater than 2' for the attic access. Please have the engineer submitt a detail showing the needed over framing in the two areas. 3. Multiple girder trusses call for VGT hold downs that have not been installed. locations circled on the plans. 4. Roof sheating was unable to be inspected. Roof tile has been installed. Inspection has been stopped. The contractor will need to contact the building department for further instruction on how to proceed. 12/19/2023 - PREVIOUS INSPECTION NOTES 132-19-2023 1. Truss layout is not readable. Please have a readable layout on site. 2. Please provide an anchor schedule. 3. Bearing walls are not indicated.
ELECTRIC-TUG 08/08/2024 APPROVED - AS NOTED BTAYLOR
Note: 7/18/2024 - PREVIOUS INSPECTION NOTES The Electrical riser installed does not match the electrical rise shown on the plan page E1. Please submit a revision to the building department for the change. Plans call for 300 amp service. Contractor installed. 400 amp 8-8-24 1. Emailed FPL at 9:13.
GRAVITY SEWER TEST 08/08/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 08/08/2024 APPROVED - AS NOTED MGIBSON
Note: THIS WAS A VIRTUAL INSPECTION
ELECTRIC-TUG 07/18/2024 Disapproved - NO FEE JWALKER
Note: The Electrical riser installed does not match the electrical rise shown on the plan page E1. Please submit a revision to the building department for the change. Plans call for 300 amp service. Contractor installed. 400 amp
WINDOW NAILING 07/02/2024 APPROVED BTAYLOR
ALL ROUGH 07/02/2024 CANCELLED BY APPLICANT BTAYLOR
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2460 06/18/24 Inspection administratively approved by CBO based on Architect's inspection letter. 5/20/2024 - PREVIOUS INSPECTION NOTES 1. The truss engineering packets provided are out of order and have gotten wet. The one packet in the job box is from 15 serpent trl. Please have a full set of approved engineered drawing onsite and in order. Ensure the cover page with the listed pages is included. 2. Items 2 and 4 listed below from the 4/23 inspection have also not been corrected. 4/23/2024 - PREVIOUS INSPECTION NOTES 1. Multiple trusses are missing engineering. A01 through A27 have been inspected A06, 7, 22, 23,24,25 and 27 are missing engineering. Truss engineering inspection was stopped at the B trusses. The rest of the trusses starting at the B's still need to be inspected. 2. Max truss spacing is 2' o.c. two areas at the right side front and garage trusses have been spaced greater than 2' for the attic access. Please have the engineer submitt a detail showing the needed over framing in the two areas. 3. Multiple girder trusses call for VGT hold downs that have not been installed. locations circled on the plans. 4. Roof sheating was unable to be inspected. Roof tile has been installed. Inspection has been stopped. The contractor will need to contact the building department for further instruction on how to proceed. 12/19/2023 - PREVIOUS INSPECTION NOTES 132-19-2023 1. Truss layout is not readable. Please have a readable layout on site. 2. Please provide an anchor schedule. 3. Bearing walls are not indicated.
ALL ROUGH 06/20/2024 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2460 06/18/24 Inspection administratively approved by CBO based on Architect's inspection letter. 5/20/2024 - PREVIOUS INSPECTION NOTES 1. The truss engineering packets provided are out of order and have gotten wet. The one packet in the job box is from 15 serpent trl. Please have a full set of approved engineered drawing onsite and in order. Ensure the cover page with the listed pages is included. 2. Items 2 and 4 listed below from the 4/23 inspection have also not been corrected. 4/23/2024 - PREVIOUS INSPECTION NOTES 1. Multiple trusses are missing engineering. A01 through A27 have been inspected A06, 7, 22, 23,24,25 and 27 are missing engineering. Truss engineering inspection was stopped at the B trusses. The rest of the trusses starting at the B's still need to be inspected. 2. Max truss spacing is 2' o.c. two areas at the right side front and garage trusses have been spaced greater than 2' for the attic access. Please have the engineer submitt a detail showing the needed over framing in the two areas. 3. Multiple girder trusses call for VGT hold downs that have not been installed. locations circled on the plans. 4. Roof sheating was unable to be inspected. Roof tile has been installed. Inspection has been stopped. The contractor will need to contact the building department for further instruction on how to proceed. 12/19/2023 - PREVIOUS INSPECTION NOTES 132-19-2023 1. Truss layout is not readable. Please have a readable layout on site. 2. Please provide an anchor schedule. 3. Bearing walls are not indicated.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 06/18/2024 APPROVED - AS NOTED PBUCKLEY
Note: 06/18/24 Inspection administratively approved by CBO based on Architect's inspection letter. 5/20/2024 - PREVIOUS INSPECTION NOTES 1. The truss engineering packets provided are out of order and have gotten wet. The one packet in the job box is from 15 serpent trl. Please have a full set of approved engineered drawing onsite and in order. Ensure the cover page with the listed pages is included. 2. Items 2 and 4 listed below from the 4/23 inspection have also not been corrected. 4/23/2024 - PREVIOUS INSPECTION NOTES 1. Multiple trusses are missing engineering. A01 through A27 have been inspected A06, 7, 22, 23,24,25 and 27 are missing engineering. Truss engineering inspection was stopped at the B trusses. The rest of the trusses starting at the B's still need to be inspected. 2. Max truss spacing is 2' o.c. two areas at the right side front and garage trusses have been spaced greater than 2' for the attic access. Please have the engineer submitt a detail showing the needed over framing in the two areas. 3. Multiple girder trusses call for VGT hold downs that have not been installed. locations circled on the plans. 4. Roof sheating was unable to be inspected. Roof tile has been installed. Inspection has been stopped. The contractor will need to contact the building department for further instruction on how to proceed. 12/19/2023 - PREVIOUS INSPECTION NOTES 132-19-2023 1. Truss layout is not readable. Please have a readable layout on site. 2. Please provide an anchor schedule. 3. Bearing walls are not indicated.
ROOF VALLEY & METAL 06/12/2024 APPROVED KSANDOE
Note: 6/11/2024 - PREVIOUS INSPECTION NOTES 6/10/2024 - PREVIOUS INSPECTION NOTES 5/20/2024 - PREVIOUS INSPECTION NOTES 4/20/24 Due to the listed item below the contractor will need to contact Robert Martin or Alpanette Waters at the building department for further instructions. 4/23/2024 - PREVIOUS INSPECTION NOTES Roof sheating was not inspected. Tile has been installed Both sides and rear.
ROOF VALLEY & METAL 06/11/2024 CANCELLED BY APPLICANT JWALKER
Note: 6/10/2024 - PREVIOUS INSPECTION NOTES 5/20/2024 - PREVIOUS INSPECTION NOTES 4/20/24 Due to the listed item below the contractor will need to contact Robert Martin or Alpanette Waters at the building department for further instructions. 4/23/2024 - PREVIOUS INSPECTION NOTES Roof sheating was not inspected. Tile has been installed Both sides and rear.
ROOF VALLEY & METAL 06/10/2024 CANCELLED BY APPLICANT JWALKER
Note: 5/20/2024 - PREVIOUS INSPECTION NOTES 4/20/24 Due to the listed item below the contractor will need to contact Robert Martin or Alpanette Waters at the building department for further instructions. 4/23/2024 - PREVIOUS INSPECTION NOTES Roof sheating was not inspected. Tile has been installed Both sides and rear.
ROOF VALLEY & METAL 05/20/2024 Disapproved -FEE REQUIRED JWALKER
Note: 4/20/24 Due to the listed item below the contractor will need to contact Robert Martin or Alpanette Waters at the building department for further instructions. 4/23/2024 - PREVIOUS INSPECTION NOTES Roof sheating was not inspected. Tile has been installed Both sides and rear.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 05/20/2024 Disapproved -FEE REQUIRED JWALKER
Note: 1. The truss engineering packets provided are out of order and have gotten wet. The one packet in the job box is from 15 serpent trl. Please have a full set of approved engineered drawing onsite and in order. Ensure the cover page with the listed pages is included. 2. Items 2 and 4 listed below from the 4/23 inspection have also not been corrected. 4/23/2024 - PREVIOUS INSPECTION NOTES 1. Multiple trusses are missing engineering. A01 through A27 have been inspected A06, 7, 22, 23,24,25 and 27 are missing engineering. Truss engineering inspection was stopped at the B trusses. The rest of the trusses starting at the B's still need to be inspected. 2. Max truss spacing is 2' o.c. two areas at the right side front and garage trusses have been spaced greater than 2' for the attic access. Please have the engineer submitt a detail showing the needed over framing in the two areas. 3. Multiple girder trusses call for VGT hold downs that have not been installed. locations circled on the plans. 4. Roof sheating was unable to be inspected. Roof tile has been installed. Inspection has been stopped. The contractor will need to contact the building department for further instruction on how to proceed. 12/19/2023 - PREVIOUS INSPECTION NOTES 132-19-2023 1. Truss layout is not readable. Please have a readable layout on site. 2. Please provide an anchor schedule. 3. Bearing walls are not indicated.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 04/23/2024 Disapproved -FEE REQUIRED JWALKER
Note: 1. Multiple trusses are missing engineering. A01 through A27 have been inspected A06, 7, 22, 23,24,25 and 27 are missing engineering. Truss engineering inspection was stopped at the B trusses. The rest of the trusses starting at the B's still need to be inspected. 2. Max truss spacing is 2' o.c. two areas at the right side front and garage trusses have been spaced greater than 2' for the attic access. Please have the engineer submitt a detail showing the needed over framing in the two areas. 3. Multiple girder trusses call for VGT hold downs that have not been installed. locations circled on the plans. 4. Roof sheating was unable to be inspected. Roof tile has been installed. Inspection has been stopped. The contractor will need to contact the building department for further instruction on how to proceed. 12/19/2023 - PREVIOUS INSPECTION NOTES 132-19-2023 1. Truss layout is not readable. Please have a readable layout on site. 2. Please provide an anchor schedule. 3. Bearing walls are not indicated.
ROOF VALLEY & METAL 04/23/2024 Disapproved -FEE REQUIRED JWALKER
Note: Roof sheating was not inspected. Tile has been installed Both sides and rear.
ELECTRIC-TUG 04/23/2024 CANCELLED BY APPLICANT JWALKER
ELECTRIC - EARLY POWER 04/23/2024 CANCELLED BY APPLICANT JWALKER
WALL SHEATHING 12/19/2023 APPROVED AGAETANO
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/19/2023 Disapproved - NO FEE AGAETANO
Note: 132-19-2023 1. Truss layout is not readable. Please have a readable layout on site. 2. Please provide an anchor schedule. 3. Bearing walls are not indicated.
WILDLIFE CHECK - ENVIRONMENTAL 12/18/2023 APPROVED DRODRIGUEZ
ELEV CERT-FOUNDATION APPROVAL 11/27/2023 APPROVED - AS NOTED JMYERS
Note: The Foundation elevation certificate has been approved, please leave measurement boxes blank in C2 if there are no elevations moving forward. However, starting November 1st, the new form must be used.
TIE BEAM / LINTEL 10/25/2023 APPROVED AGAETANO
FOUND SURVEY APPROVED (OFFICE) 10/09/2023 APPROVED TDOAK
MONOLITHIC SLAB 09/18/2023 APPROVED AGAETANO
PLUMBING 1ST ROUGH UNDERGROUND 08/25/2023 APPROVED MGIBSON
ROW - DRAINAGE 04/28/2023 Disapproved - NO FEE EMADISON
Note: ** 04/28/23 BUILDER NEEDS TO INSTALL A SILT FENCE ON LEFT SIDE FROM PROPERTY LINE TO RIGHT SIDE PROPERTY LINE ** FOLLOW UP INSPECTION 05/05/23 __________________________________________________________________________________________________________________________ rjg. Concerned residence. Please check for silt fence compliance.
RETAINING WALL 02/06/2023 APPROVED AGAETANO
Note: 2/2/2023 - PREVIOUS INSPECTION NOTES 02-02-2023
RETAINING WALL 02/02/2023 Disapproved - NO FEE AGAETANO
Note: 02-02-2023 A1 Table 1 indicates #4 rebar at 32" oc. Please install as per plans or revise to the building department. Check all retaining wall vertical rebar.
RETAINING WALL FOUNDATION 01/13/2023 APPROVED AGAETANO
WATER METER INSTALLATION REQUEST 10/12/2022 APPROVED CSTONE

Review History

Department Status Date In Date Out
MECH COMPLETE 03/26/2025 03/26/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BADMIN INFORMATION 03/13/2025 03/13/2025
Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM 1. RENAME TO ENERGY CALCS.PDF 2. SCAN INCOMPLETE. SCANNED IN LANDSCAPE INSTEAD PORTRAIT. MISSING TOP/BOTTOM PORTIONS
MECH COMPLETE 03/13/2025 03/14/2025
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
PLFM COMPLETE 02/24/2025 02/25/2025
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM The Final elevation certificate has been approved.
ELEC COMPLETE 07/30/2024 08/01/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 06/13/2024 06/18/2024
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM KS
BLD COMPLETE 03/21/2024 03/25/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 10/09/2023 10/12/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
PLFM COMPLETE 10/09/2023 10/12/2023
Note: Released By: JORDAN MYERS, C.F.M - (386)986-4789 - JMYERS@PALMCOASTGOV.COM The Foundation elevation certificate has been approved, please leave measurement boxes blank in C2 if there are no elevations moving forward. However, starting November 1st, the new form must be used.
ZON COMPLETE 10/09/2023 10/09/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
PLFM COMPLETE 06/13/2022 06/13/2022
Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM The construction elevation certificate has been approved. However, please leave the measurement box blank if there is no elevation C2b at Foundation EC.
BLD COMPLETE 06/13/2022 06/14/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 06/13/2022 06/13/2022
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
URB COMPLETE 06/07/2022 06/08/2022
Note: Released By: JOHN BEAUDET - (386)986-2456 -
PLFM HOLD 06/07/2022 06/07/2022
Note: Held By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM According to the Site Plan submitted on 6/6/22, the structure will fall inside of the Special Flood Hazard Area. Elevation certificates will be required at construction, foundation, and final.
PLENV COMPLETE 06/07/2022 06/09/2022
Note: Released By: JORDAN MYERS, C.F.M - (386)986-2320 - JMYERS@PALMCOASTGOV.COM Staff conducted a site visit on 6/9/22 and found no Gopher Tortoise or their burrows. Staff suggests placing silt fence as soon as possible to prevent tortoise from moving into the lot.
BLD HOLD 06/06/2022 06/09/2022
Note: Held By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM All comments from FBC Residential 2020 7th edition 1. Provide product approval number for casement windows or revise plans to show single hung 2. Provide details showing casement window in Bed 3 meets egress requirements per R311.1
CUSVC COMPLETE 06/06/2022 06/06/2022
Note: Released By: CYNTHIA SCHWEERS - - CSCHWEERS@PALMCOASSTGOV.COM
ELEC HOLD 06/06/2022 06/07/2022
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM Need correct outlet spacing in bed 2. NEC 2017 210.52
ENGIN1 COMPLETE 06/06/2022 06/06/2022
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
LOCATE COMPLETE 06/06/2022 06/08/2022
Note: Released By: CANDACE STONE - - CSTONE@PALMCOASTGOV.COM
MECH COMPLETE 06/06/2022 06/07/2022
Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 06/06/2022 06/13/2022
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 06/06/2022 06/07/2022
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 03/26/2025
REINSPECTION RESIDENTIAL ¤40.00 03/26/2025
REINSPECTION RESIDENTIAL ¤40.00 03/26/2025
REINSPECTION RESIDENTIAL ¤40.00 03/26/2025
CONTRACTOR CHANGE ¤20.00 03/26/2025
SURCHARGE FS 533.721 ¤7.42 08/24/2023
SURCHARGE - FS 468.631 ¤11.14 08/24/2023
SW ENG - INSPECTION 20 ¤20.00 08/24/2023
SW ENG - INSPECTION 20 ¤20.00 08/24/2023
SW ENG INSPECTION 80 ¤80.00 08/24/2023
SW ENG PRE APRON ¤30.00 08/24/2023
ADJUSTMENT 50% (¤742.38) 08/24/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 08/24/2023
INSPECTION - RESIDENTIAL ¤1,454.75 08/24/2023
Fees Total Due: ¤0.00 Total Paid: ¤1,090.93