Permit #2023081453
Permit Details
Status: COED
| Parcel Id: 07-11-31-7026-00020-0380 |
| CONDITIONED SPACE: 2956 sqft |
| GARAGE: 888 sqft |
| OPENED PORCH (WITH ROOF) : 270 sqft |
| Total Square Footage: 4114 sqft |
| Block: 00020 |
| Subdivision: 2153 - SECTION 26-PINE GROVE |
| Job Phone: 386-237-5837 |
| Location Address: 20 PINE HILL LN |
| Type: DU - DUPLEX |
| Issue Date: 09/18/2023 |
| NOC: RECORDED |
| Applicant name: MARSEL GILMANSHIN |
| Owner: LOURI SINKEVITCH |
|
Address 412 OCEANVIEW AVE #5C BROOKLYN, NY 11235 |
| Lot: 0380 |
| Contracted Stated Job Value: ¤400,000.00 |
| Job Description: DUPLEX |
| Type: CN |
Contractor
GILMANS DEVELOPMENT CORP
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
Sub Contractors
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
ANDREY GORZDEV
| Status | Location Address | State License Number | Phone |
| ACTIVE |
12278 PEANUT CT JACKSONVILLE, FL 32226 |
CAC1823458 (Exp: 08/31/2026) | 904-574-1000 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL INSPECTION | 03/28/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/27/2025 - PREVIOUS INSPECTION NOTES SPOKE WITH CM ABOUT OVER POUR AND SEDIMENT AND HE WILL CLEAN PIPES BEFORE SUBMITTING FOR NEXT INSPECTION ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/25/2025 - PREVIOUS INSPECTION NOTES 03/25/25 TPOLACEK*** ALL OVERPOUR INSIDE CULVERT NEEDS TO BE CHIPPED AND ENTIRE LENGTH OF CULVERT NEEDS TO BE FREE AND CLEAR OF DEBRIS. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/24/2025 - PREVIOUS INSPECTION NOTES 03/24/26 TPOLACEK*** BUILDER NEEDS TO CLEAN OUT CULVERTS OF ALL OVER POUR AND DEBRIS, ALL TRASH INCLUDING CONCRETE AND PALLETTS NEEDS TO BE REMOVED BEFORE FINAL ROW INSPECTION CAN BE APPROVED. 12 Trash in Vacant Sec 300.03 F4 Sec 300.03 F4 The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Inspector Notes from Inspection 9465 1/31/25 BERM CORRECTION MADE AT THE TIME OF THIS INSPECTION. YOU WILL NEED TO REPAIR, RESLOPE AND RESET SOD TO GRADE IN THE FRONT RIGHT SWALE BACK TO PAST ROW. YOU WILL NEED TO RESOD TO GRADE BARE AREAS THAT WERE DISTURBED ON BOTH REAR CORNERS OF THE STRUCTURE BEFORE ROW FINAL PASSAGE. APPROVING AS NOTED AS A COURTESY SO YOU MAY MOVE AHEAD WITH INSPECTIONS. 1/16/2025 - PREVIOUS INSPECTION NOTES NEED TO TAKE OUT BERMS ALONG LEFT AND RIGHT PROPERTY BECAUSE THE BERMS ARE NOT MAINTAINABLE. YOU NEED TO FIX THE ISSUE SO WATER WILL NOT IMPACT THE ADJACENT LOTS WITH 5" HUMPS ALONG THE PROPERTY LINES ------------------------------------------------------------------------- 12/23/2024 - PREVIOUS INSPECTION NOTES FINAL SURVEY MUST BE APPROVED BEFORE FIED SURVEY CAN BE CONDUCTED | |||
| ROW - FINAL INSPECTION | 03/27/2025 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: SPOKE WITH CM ABOUT OVER POUR AND SEDIMENT AND HE WILL CLEAN PIPES BEFORE SUBMITTING FOR NEXT INSPECTION ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/25/2025 - PREVIOUS INSPECTION NOTES 03/25/25 TPOLACEK*** ALL OVERPOUR INSIDE CULVERT NEEDS TO BE CHIPPED AND ENTIRE LENGTH OF CULVERT NEEDS TO BE FREE AND CLEAR OF DEBRIS. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/24/2025 - PREVIOUS INSPECTION NOTES 03/24/26 TPOLACEK*** BUILDER NEEDS TO CLEAN OUT CULVERTS OF ALL OVER POUR AND DEBRIS, ALL TRASH INCLUDING CONCRETE AND PALLETTS NEEDS TO BE REMOVED BEFORE FINAL ROW INSPECTION CAN BE APPROVED. 12 Trash in Vacant Sec 300.03 F4 Sec 300.03 F4 The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Inspector Notes from Inspection 9465 1/31/25 BERM CORRECTION MADE AT THE TIME OF THIS INSPECTION. YOU WILL NEED TO REPAIR, RESLOPE AND RESET SOD TO GRADE IN THE FRONT RIGHT SWALE BACK TO PAST ROW. YOU WILL NEED TO RESOD TO GRADE BARE AREAS THAT WERE DISTURBED ON BOTH REAR CORNERS OF THE STRUCTURE BEFORE ROW FINAL PASSAGE. APPROVING AS NOTED AS A COURTESY SO YOU MAY MOVE AHEAD WITH INSPECTIONS. 1/16/2025 - PREVIOUS INSPECTION NOTES NEED TO TAKE OUT BERMS ALONG LEFT AND RIGHT PROPERTY BECAUSE THE BERMS ARE NOT MAINTAINABLE. YOU NEED TO FIX THE ISSUE SO WATER WILL NOT IMPACT THE ADJACENT LOTS WITH 5" HUMPS ALONG THE PROPERTY LINES ------------------------------------------------------------------------- 12/23/2024 - PREVIOUS INSPECTION NOTES FINAL SURVEY MUST BE APPROVED BEFORE FIED SURVEY CAN BE CONDUCTED | |||
| ROW - FINAL INSPECTION | 03/25/2025 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 03/25/25 TPOLACEK*** ALL OVERPOUR INSIDE CULVERT NEEDS TO BE CHIPPED AND ENTIRE LENGTH OF CULVERT NEEDS TO BE FREE AND CLEAR OF DEBRIS. +++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 3/24/2025 - PREVIOUS INSPECTION NOTES 03/24/26 TPOLACEK*** BUILDER NEEDS TO CLEAN OUT CULVERTS OF ALL OVER POUR AND DEBRIS, ALL TRASH INCLUDING CONCRETE AND PALLETTS NEEDS TO BE REMOVED BEFORE FINAL ROW INSPECTION CAN BE APPROVED. 12 Trash in Vacant Sec 300.03 F4 Sec 300.03 F4 The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Inspector Notes from Inspection 9465 1/31/25 BERM CORRECTION MADE AT THE TIME OF THIS INSPECTION. YOU WILL NEED TO REPAIR, RESLOPE AND RESET SOD TO GRADE IN THE FRONT RIGHT SWALE BACK TO PAST ROW. YOU WILL NEED TO RESOD TO GRADE BARE AREAS THAT WERE DISTURBED ON BOTH REAR CORNERS OF THE STRUCTURE BEFORE ROW FINAL PASSAGE. APPROVING AS NOTED AS A COURTESY SO YOU MAY MOVE AHEAD WITH INSPECTIONS. 1/16/2025 - PREVIOUS INSPECTION NOTES NEED TO TAKE OUT BERMS ALONG LEFT AND RIGHT PROPERTY BECAUSE THE BERMS ARE NOT MAINTAINABLE. YOU NEED TO FIX THE ISSUE SO WATER WILL NOT IMPACT THE ADJACENT LOTS WITH 5" HUMPS ALONG THE PROPERTY LINES ------------------------------------------------------------------------- 12/23/2024 - PREVIOUS INSPECTION NOTES FINAL SURVEY MUST BE APPROVED BEFORE FIED SURVEY CAN BE CONDUCTED | |||
| ROW - FINAL INSPECTION | 03/24/2025 | Disapproved - NO FEE | TPOLACEK |
| Note: 03/24/26 TPOLACEK*** BUILDER NEEDS TO CLEAN OUT CULVERTS OF ALL OVER POUR AND DEBRIS, ALL TRASH INCLUDING CONCRETE AND PALLETTS NEEDS TO BE REMOVED BEFORE FINAL ROW INSPECTION CAN BE APPROVED. 12 Trash in Vacant Sec 300.03 F4 Sec 300.03 F4 The Stormwater Final Inspection will include visual inspection of the site and adjacent properties for debris, proper clean up and repair to damaged terrain. Inspector Notes from Inspection 9465 1/31/25 BERM CORRECTION MADE AT THE TIME OF THIS INSPECTION. YOU WILL NEED TO REPAIR, RESLOPE AND RESET SOD TO GRADE IN THE FRONT RIGHT SWALE BACK TO PAST ROW. YOU WILL NEED TO RESOD TO GRADE BARE AREAS THAT WERE DISTURBED ON BOTH REAR CORNERS OF THE STRUCTURE BEFORE ROW FINAL PASSAGE. APPROVING AS NOTED AS A COURTESY SO YOU MAY MOVE AHEAD WITH INSPECTIONS. 1/16/2025 - PREVIOUS INSPECTION NOTES NEED TO TAKE OUT BERMS ALONG LEFT AND RIGHT PROPERTY BECAUSE THE BERMS ARE NOT MAINTAINABLE. YOU NEED TO FIX THE ISSUE SO WATER WILL NOT IMPACT THE ADJACENT LOTS WITH 5" HUMPS ALONG THE PROPERTY LINES ------------------------------------------------------------------------- 12/23/2024 - PREVIOUS INSPECTION NOTES FINAL SURVEY MUST BE APPROVED BEFORE FIED SURVEY CAN BE CONDUCTED | |||
| ROW - FINAL APRON (AFTER POUR) | 03/24/2025 | APPROVED | TPOLACEK |
| Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| BLD - BUILDING FINAL | 03/07/2025 | FINAL APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 3/7/2025 3:54:02 PM *** 3/7/25: Holding Inspection for Kitchen outlet verification. *** No power (power loss) in Unit B so kitchen outlets could not be verified for GFCI & 2-small appliance circuits. 2/28/2025 - PREVIOUS INSPECTION NOTES 2/28/25: Both Units: 1). Still missing address. FBCR 319.1 2). Missing Surge protectors. NEC 230.67 3). Meter Main panels need to be (permanently) labeled as required. NEC 408.4 (A) 4). Downspouts need extension or splash blocks to make 12" away from foundation. FBC-R318.5 5). Metal chase for lineset in garage needs to be sealed at the bottom. FBC-302.11 6). Kitchen island wall outlets need to be on a different circuit from kitchen small appliance outlets above counter. NEC-210.52(B)(2). 7). Kitchen island wall outlets need to be moved at least 18" below the counter to the top of the receptacle box. NEC210.52(A)(2). *** Unit A: 8). Outside AC unit needs to be 3" above finished grade. FBCR M1305.1.4.1 9). Missing locking port caps on outdoor AC unit. FBC - M1411.8 10). Hole in exterior wall behind AC unit needs to be sealed. FBC [A]107.4 *** Unit B: 11). Still missing attic light bulb. NEC-210.70(2)(C) 12). Previously listed item 11: Guest bathroom sink needs to be sealed tightly to wall to create a watertight seal as required by FBC-P2705.1(3) 2/25/2025 - PREVIOUS INSPECTION NOTES 2/25/25: Cancelled by Applicant via text at @ 08:56. Stated not ready. New inspection due to canceled inspection 2/3/2025 - PREVIOUS INSPECTION NOTES 2/3/35 1. Needs address posted FBCR 319.1 2. No plans on site FBC(A) 107.3.1 3. Unit A has no power (no inspection was done due to this) FBC(A) 107.4 4. All soffit vents are missing covers and are required to have solid soffit at least 5' around vents FBC-R806.4 & R903.1 5. No surge protection installed NEC 230.67 Unit B: 6. Missing bulb in attic 7. Missing attic access cover FBCR 302.6 8. SGD needs adjustment 9. Main light in master bedroom not working FBC(A) 107.4 10. Left window in dining room not closing properly FBC(A) 107.4 11. Install backsplash or seal up around sink in guest bath 12. Garbage disposal switch not working FBC(A) 107.4 13. Missing notice for AH in attic FBC EC R403.3.6 **DUE TO NO PLANS ON SITE, NO ENERGY CALC WERE AVAILABLE FOR HVAC INSPECTION** Inspector Notes from Inspection 2425 *** NOTES ADDED BY RSIMS 1/9/2025 9:34:56 AM *** 1/9/25: Window nailing inspection is approved as noted waiting on newly submitted NOC to be reviewed and approved. Building Final can not be approved until the NOC is approved. Conducted inspection with superintendant on 01/07/2025. Both sliding doors were found to be missing attachment hardware along the top of the frame. Superintendant made repairs on site while I conducted the rest of the inspection. All windows were found to have all required mounting hardware. Unable to inspect gap between bucking and window frame due to installed finishes, builder assumes all further responsibility. 12/23/2024 - PREVIOUS INSPECTION NOTES 12/23/24: Inspection missed by Builder. This Duplex is totally finished with drywall and exterior stucco, therefore this inspection cannot be completed. Please contact the Deputy Cheif Building Official or the Building Department for information on how to complete this inspection. | |||
| BLD - BUILDING FINAL | 02/28/2025 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/28/2025 4:20:09 PM *** 2/28/25: Both Units: 1). Still missing address. FBCR 319.1 2). Missing Surge protectors. NEC 230.67 3). Meter Main panels need to be (permanently) labeled as required. NEC 408.4 (A) 4). Downspouts need extension or splash blocks to make 12" away from foundation. FBC-R318.5 5). Metal chase for lineset in garage needs to be sealed at the bottom. FBC-302.11 6). Kitchen island wall outlets need to be on a different circuit from kitchen small appliance outlets above counter. NEC-210.52(B)(2). 7). Kitchen island wall outlets need to be moved at least 18" below the counter to the top of the receptacle box. NEC210.52(A)(2). *** Unit A: 8). Outside AC unit needs to be 3" above finished grade. FBCR M1305.1.4.1 9). Missing locking port caps on outdoor AC unit. FBC - M1411.8 10). Hole in exterior wall behind AC unit needs to be sealed. FBC [A]107.4 *** Unit B: 11). Still missing attic light bulb. NEC-210.70(2)(C) 12). Previously listed item 11: Guest bathroom sink needs to be sealed tightly to wall to create a watertight seal as required by FBC-P2705.1(3) 2/25/2025 - PREVIOUS INSPECTION NOTES 2/25/25: Cancelled by Applicant via text at @ 08:56. Stated not ready. New inspection due to canceled inspection 2/3/2025 - PREVIOUS INSPECTION NOTES 2/3/35 1. Needs address posted FBCR 319.1 2. No plans on site FBC(A) 107.3.1 3. Unit A has no power (no inspection was done due to this) FBC(A) 107.4 4. All soffit vents are missing covers and are required to have solid soffit at least 5' around vents FBC-R806.4 & R903.1 5. No surge protection installed NEC 230.67 Unit B: 6. Missing bulb in attic 7. Missing attic access cover FBCR 302.6 8. SGD needs adjustment 9. Main light in master bedroom not working FBC(A) 107.4 10. Left window in dining room not closing properly FBC(A) 107.4 11. Install backsplash or seal up around sink in guest bath 12. Garbage disposal switch not working FBC(A) 107.4 13. Missing notice for AH in attic FBC EC R403.3.6 **DUE TO NO PLANS ON SITE, NO ENERGY CALC WERE AVAILABLE FOR HVAC INSPECTION** Inspector Notes from Inspection 2425 *** NOTES ADDED BY RSIMS 1/9/2025 9:34:56 AM *** 1/9/25: Window nailing inspection is approved as noted waiting on newly submitted NOC to be reviewed and approved. Building Final can not be approved until the NOC is approved. Conducted inspection with superintendant on 01/07/2025. Both sliding doors were found to be missing attachment hardware along the top of the frame. Superintendant made repairs on site while I conducted the rest of the inspection. All windows were found to have all required mounting hardware. Unable to inspect gap between bucking and window frame due to installed finishes, builder assumes all further responsibility. 12/23/2024 - PREVIOUS INSPECTION NOTES 12/23/24: Inspection missed by Builder. This Duplex is totally finished with drywall and exterior stucco, therefore this inspection cannot be completed. Please contact the Deputy Cheif Building Official or the Building Department for information on how to complete this inspection. | |||
| ROW - FINAL INSPECTION | 02/28/2025 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: 02/28/25 TPOLACEK** SPOKE WITH BUILDER THEY ASKED TO CANCEL AS THEY HAVE NOT YET SODDED BARE AREAS IN REAR. Inspector Notes from Inspection 9465 1/31/25 BERM CORRECTION MADE AT THE TIME OF THIS INSPECTION. YOU WILL NEED TO REPAIR, RESLOPE AND RESET SOD TO GRADE IN THE FRONT RIGHT SWALE BACK TO PAST ROW. YOU WILL NEED TO RESOD TO GRADE BARE AREAS THAT WERE DISTURBED ON BOTH REAR CORNERS OF THE STRUCTURE BEFORE ROW FINAL PASSAGE. APPROVING AS NOTED AS A COURTESY SO YOU MAY MOVE AHEAD WITH INSPECTIONS. 1/16/2025 - PREVIOUS INSPECTION NOTES NEED TO TAKE OUT BERMS ALONG LEFT AND RIGHT PROPERTY BECAUSE THE BERMS ARE NOT MAINTAINABLE. YOU NEED TO FIX THE ISSUE SO WATER WILL NOT IMPACT THE ADJACENT LOTS WITH 5" HUMPS ALONG THE PROPERTY LINES ------------------------------------------------------------------------- 12/23/2024 - PREVIOUS INSPECTION NOTES FINAL SURVEY MUST BE APPROVED BEFORE FIED SURVEY CAN BE CONDUCTED | |||
| BLD - BUILDING FINAL | 02/25/2025 | CANCELLED BY APPLICANT | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 2/25/2025 9:00:02 AM *** 2/25/25: Cancelled by Applicant via text at @ 08:56. Stated not ready. New inspection due to canceled inspection 2/3/2025 - PREVIOUS INSPECTION NOTES 2/3/35 1. Needs address posted FBCR 319.1 2. No plans on site FBC(A) 107.3.1 3. Unit A has no power (no inspection was done due to this) FBC(A) 107.4 4. All soffit vents are missing covers and are required to have solid soffit at least 5' around vents FBC-R806.4 & R903.1 5. No surge protection installed NEC 230.67 Unit B: 6. Missing bulb in attic 7. Missing attic access cover FBCR 302.6 8. SGD needs adjustment 9. Main light in master bedroom not working FBC(A) 107.4 10. Left window in dining room not closing properly FBC(A) 107.4 11. Install backsplash or seal up around sink in guest bath 12. Garbage disposal switch not working FBC(A) 107.4 13. Missing notice for AH in attic FBC EC R403.3.6 **DUE TO NO PLANS ON SITE, NO ENERGY CALC WERE AVAILABLE FOR HVAC INSPECTION** Inspector Notes from Inspection 2425 *** NOTES ADDED BY RSIMS 1/9/2025 9:34:56 AM *** 1/9/25: Window nailing inspection is approved as noted waiting on newly submitted NOC to be reviewed and approved. Building Final can not be approved until the NOC is approved. Conducted inspection with superintendant on 01/07/2025. Both sliding doors were found to be missing attachment hardware along the top of the frame. Superintendant made repairs on site while I conducted the rest of the inspection. All windows were found to have all required mounting hardware. Unable to inspect gap between bucking and window frame due to installed finishes, builder assumes all further responsibility. 12/23/2024 - PREVIOUS INSPECTION NOTES 12/23/24: Inspection missed by Builder. This Duplex is totally finished with drywall and exterior stucco, therefore this inspection cannot be completed. Please contact the Deputy Cheif Building Official or the Building Department for information on how to complete this inspection. | |||
| U -UTILITY RESIDENTIAL FINAL | 02/11/2025 | FINAL APPROVED | LFITZGERALD |
| Note: 2/3/2025 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9035 pep panel with no power -left unit(no npower to unit) *** NOTES ADDED BY LFITZGERALD 10/28/2024 1:21:07 PM *** no irrigation-no cross connection | |||
| BLD - BUILDING FINAL | 02/11/2025 | CANCELLED BY APPLICANT | WEB |
| Note: 2/3/2025 - PREVIOUS INSPECTION NOTES 2/3/35 1. Needs address posted FBCR 319.1 2. No plans on site FBC(A) 107.3.1 3. Unit A has no power (no inspection was done due to this) FBC(A) 107.4 4. All soffit vents are missing covers and are required to have solid soffit at least 5' around vents FBC-R806.4 & R903.1 5. No surge protection installed NEC 230.67 Unit B: 6. Missing bulb in attic 7. Missing attic access cover FBCR 302.6 8. SGD needs adjustment 9. Main light in master bedroom not working FBC(A) 107.4 10. Left window in dining room not closing properly FBC(A) 107.4 11. Install backsplash or seal up around sink in guest bath 12. Garbage disposal switch not working FBC(A) 107.4 13. Missing notice for AH in attic FBC EC R403.3.6 **DUE TO NO PLANS ON SITE, NO ENERGY CALC WERE AVAILABLE FOR HVAC INSPECTION** Inspector Notes from Inspection 2425 *** NOTES ADDED BY RSIMS 1/9/2025 9:34:56 AM *** 1/9/25: Window nailing inspection is approved as noted waiting on newly submitted NOC to be reviewed and approved. Building Final can not be approved until the NOC is approved. Conducted inspection with superintendant on 01/07/2025. Both sliding doors were found to be missing attachment hardware along the top of the frame. Superintendant made repairs on site while I conducted the rest of the inspection. All windows were found to have all required mounting hardware. Unable to inspect gap between bucking and window frame due to installed finishes, builder assumes all further responsibility. 12/23/2024 - PREVIOUS INSPECTION NOTES 12/23/24: Inspection missed by Builder. This Duplex is totally finished with drywall and exterior stucco, therefore this inspection cannot be completed. Please contact the Deputy Cheif Building Official or the Building Department for information on how to complete this inspection. | |||
| BLD - BUILDING FINAL | 02/03/2025 | Disapproved -FEE REQUIRED | MCONTRYMAN |
| Note: 2/3/35 1. Needs address posted FBCR 319.1 2. No plans on site FBC(A) 107.3.1 3. Unit A has no power (no inspection was done due to this) FBC(A) 107.4 4. All soffit vents are missing covers and are required to have solid soffit at least 5' around vents FBC-R806.4 & R903.1 5. No surge protection installed NEC 230.67 Unit B: 6. Missing bulb in attic 7. Missing attic access cover FBCR 302.6 8. SGD needs adjustment 9. Main light in master bedroom not working FBC(A) 107.4 10. Left window in dining room not closing properly FBC(A) 107.4 11. Install backsplash or seal up around sink in guest bath 12. Garbage disposal switch not working FBC(A) 107.4 13. Missing notice for AH in attic FBC EC R403.3.6 **DUE TO NO PLANS ON SITE, NO ENERGY CALC WERE AVAILABLE FOR HVAC INSPECTION** Inspector Notes from Inspection 2425 *** NOTES ADDED BY RSIMS 1/9/2025 9:34:56 AM *** 1/9/25: Window nailing inspection is approved as noted waiting on newly submitted NOC to be reviewed and approved. Building Final can not be approved until the NOC is approved. Conducted inspection with superintendant on 01/07/2025. Both sliding doors were found to be missing attachment hardware along the top of the frame. Superintendant made repairs on site while I conducted the rest of the inspection. All windows were found to have all required mounting hardware. Unable to inspect gap between bucking and window frame due to installed finishes, builder assumes all further responsibility. 12/23/2024 - PREVIOUS INSPECTION NOTES 12/23/24: Inspection missed by Builder. This Duplex is totally finished with drywall and exterior stucco, therefore this inspection cannot be completed. Please contact the Deputy Cheif Building Official or the Building Department for information on how to complete this inspection. | |||
| U -UTILITY RESIDENTIAL FINAL | 02/03/2025 | Disapproved -FEE REQUIRED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 pep panel with no power -left unit(no npower to unit) *** NOTES ADDED BY LFITZGERALD 10/28/2024 1:21:07 PM *** no irrigation-no cross connection | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/31/2025 | APPROVED - AS NOTED | FSLADISH |
| Note: 1/31/25 BERM CORRECTION MADE AT THE TIME OF THIS INSPECTION. YOU WILL NEED TO REPAIR, RESLOPE AND RESET SOD TO GRADE IN THE FRONT RIGHT SWALE BACK TO PAST ROW. YOU WILL NEED TO RESOD TO GRADE BARE AREAS THAT WERE DISTURBED ON BOTH REAR CORNERS OF THE STRUCTURE BEFORE ROW FINAL PASSAGE. APPROVING AS NOTED AS A COURTESY SO YOU MAY MOVE AHEAD WITH INSPECTIONS. 1/16/2025 - PREVIOUS INSPECTION NOTES NEED TO TAKE OUT BERMS ALONG LEFT AND RIGHT PROPERTY BECAUSE THE BERMS ARE NOT MAINTAINABLE. YOU NEED TO FIX THE ISSUE SO WATER WILL NOT IMPACT THE ADJACENT LOTS WITH 5" HUMPS ALONG THE PROPERTY LINES ------------------------------------------------------------------------- 12/23/2024 - PREVIOUS INSPECTION NOTES FINAL SURVEY MUST BE APPROVED BEFORE FIED SURVEY CAN BE CONDUCTED | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 01/16/2025 | Disapproved - NO FEE | PFLANAGAN |
| Note: NEED TO TAKE OUT BERMS ALONG LEFT AND RIGHT PROPERTY BECAUSE THE BERMS ARE NOT MAINTAINABLE. YOU NEED TO FIX THE ISSUE SO WATER WILL NOT IMPACT THE ADJACENT LOTS WITH 5" HUMPS ALONG THE PROPERTY LINES ------------------------------------------------------------------------- 12/23/2024 - PREVIOUS INSPECTION NOTES FINAL SURVEY MUST BE APPROVED BEFORE FIED SURVEY CAN BE CONDUCTED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 01/16/2025 | APPROVED | PFLANAGAN |
| Note: CORRECTIONS MADE TO FINAL SURVEY ---------------------------------------------------------- 12/19/2024 - PREVIOUS INSPECTION NOTES 12/19/24 TPOLACEK*** FINAL SURVEY INDICATES THERE IS NOT ENOUGH FALL OFF THE REAR OF THE STRUCTURE. YOU ARE REQUIRED TO HAVE .50 OR 6" OF FALL OFF THE STRUCTURE IN THE 1ST 10'. YOUR SITE PLAN CALLS FOR AN INSIDE SWALE ALONG BOTH PROPERTY LINES. INSIDE SWALE MUST HAVE A MINIMUM OF .30 FROM TIP TO TOE PREVENTING NEGATIVE IMPACT TO ADJACENT PROPERTIES. YOUR FINAL SURVEY DOES NOT INDICATE THIS. ALL SLOPES CONNECTING IMPROVED PROPERTIES MUST CONSIST OF A 4-1 SLOPE INCLUDING THE REAR OF THE PROPERTY. Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT E.Florida Building Code, Residential, Chapter 4, R401.3" 19 Top of the slope sec 300.02.C(6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. 11 4 to 1 slope at the property lines on improved lots Sec 300.03 C1c / Sec 300.04 b5 Sec 300.03 C1c All slopes must adjoin existing improved properties at no greater than a 4:1 slope. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1, in expectation that eventually the vacant lot will be developed and graded to match the adjoining property elevation. Inspector Notes from Inspection 9270 9/4/24 CORRECTION REQUIRED MADE AT THE TIME OF THIS INSPECTION. PIPE ELEVATIONS ARE GOOD. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes, but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. 8/28/2024 - PREVIOUS INSPECTION NOTES 1) THE LEFT DRIVEWAY THE FACE BOARD ALONG EDGE OF THE ROAD IS DOWN NEED TO REFORM SO YOU HAVE THE MINIMUM AMOUNT OF CONCRETE. 2) THE RIGHT CULVERT OR THE MOST WEST CULVERT IS FLOWING THE WRONG DIRECTION. NEED TO RESET CULVERT SO IT FLOW FROM RIGHT TO LEFT LIKE SWALE PLAN DETAIL STATES. Inspector Notes from Inspection 9270 9/4/24 CORRECTION REQUIRED MADE AT THE TIME OF THIS INSPECTION. PIPE ELEVATIONS ARE GOOD. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes, but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. 8/28/2024 - PREVIOUS INSPECTION NOTES 1) THE LEFT DRIVEWAY THE FACE BOARD ALONG EDGE OF THE ROAD IS DOWN NEED TO REFORM SO YOU HAVE THE MINIMUM AMOUNT OF CONCRETE. 2) THE RIGHT CULVERT OR THE MOST WEST CULVERT IS FLOWING THE WRONG DIRECTION. NEED TO RESET CULVERT SO IT FLOW FROM RIGHT TO LEFT LIKE SWALE PLAN DETAIL STATES. | |||
| WINDOW NAILING | 01/09/2025 | APPROVED - AS NOTED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 1/9/2025 9:34:56 AM *** 1/9/25: Window nailing inspection is approved as noted waiting on newly submitted NOC to be reviewed and approved. Building Final can not be approved until the NOC is approved. Conducted inspection with superintendant on 01/07/2025. Both sliding doors were found to be missing attachment hardware along the top of the frame. Superintendant made repairs on site while I conducted the rest of the inspection. All windows were found to have all required mounting hardware. Unable to inspect gap between bucking and window frame due to installed finishes, builder assumes all further responsibility. 12/23/2024 - PREVIOUS INSPECTION NOTES 12/23/24: Inspection missed by Builder. This Duplex is totally finished with drywall and exterior stucco, therefore this inspection cannot be completed. Please contact the Deputy Cheif Building Official or the Building Department for information on how to complete this inspection. | |||
| WINDOW NAILING | 12/23/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 12/23/2024 10:09:48 AM *** 12/23/24: Inspection missed by Builder. This Duplex is totally finished with drywall and exterior stucco, therefore this inspection cannot be completed. Please contact the Deputy Cheif Building Official or the Building Department for information on how to complete this inspection. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 12/23/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: FINAL SURVEY MUST BE APPROVED BEFORE FIED SURVEY CAN BE CONDUCTED | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 12/19/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: 12/19/24 TPOLACEK*** FINAL SURVEY INDICATES THERE IS NOT ENOUGH FALL OFF THE REAR OF THE STRUCTURE. YOU ARE REQUIRED TO HAVE .50 OR 6" OF FALL OFF THE STRUCTURE IN THE 1ST 10'. YOUR SITE PLAN CALLS FOR AN INSIDE SWALE ALONG BOTH PROPERTY LINES. INSIDE SWALE MUST HAVE A MINIMUM OF .30 FROM TIP TO TOE PREVENTING NEGATIVE IMPACT TO ADJACENT PROPERTIES. YOUR FINAL SURVEY DOES NOT INDICATE THIS. ALL SLOPES CONNECTING IMPROVED PROPERTIES MUST CONSIST OF A 4-1 SLOPE INCLUDING THE REAR OF THE PROPERTY. Drainage from the structure is to be a 6-inch (5%) Residential, Chapter 4, R401.3 "Drainage from the structure is to be a 6-inch (5%) minimum slope for the first 10 FT E.Florida Building Code, Residential, Chapter 4, R401.3" 19 Top of the slope sec 300.02.C(6) The top of slope of “W” swales along the property lines shall be a minimum of 0.30 of a foot higher than the toe of slope. 11 4 to 1 slope at the property lines on improved lots Sec 300.03 C1c / Sec 300.04 b5 Sec 300.03 C1c All slopes must adjoin existing improved properties at no greater than a 4:1 slope. Slopes along developable vacant lots shall have a stabilized slope of no greater than 2:1, in expectation that eventually the vacant lot will be developed and graded to match the adjoining property elevation. Inspector Notes from Inspection 9270 9/4/24 CORRECTION REQUIRED MADE AT THE TIME OF THIS INSPECTION. PIPE ELEVATIONS ARE GOOD. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes, but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. 8/28/2024 - PREVIOUS INSPECTION NOTES 1) THE LEFT DRIVEWAY THE FACE BOARD ALONG EDGE OF THE ROAD IS DOWN NEED TO REFORM SO YOU HAVE THE MINIMUM AMOUNT OF CONCRETE. 2) THE RIGHT CULVERT OR THE MOST WEST CULVERT IS FLOWING THE WRONG DIRECTION. NEED TO RESET CULVERT SO IT FLOW FROM RIGHT TO LEFT LIKE SWALE PLAN DETAIL STATES. Inspector Notes from Inspection 9270 9/4/24 CORRECTION REQUIRED MADE AT THE TIME OF THIS INSPECTION. PIPE ELEVATIONS ARE GOOD. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes, but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. 8/28/2024 - PREVIOUS INSPECTION NOTES 1) THE LEFT DRIVEWAY THE FACE BOARD ALONG EDGE OF THE ROAD IS DOWN NEED TO REFORM SO YOU HAVE THE MINIMUM AMOUNT OF CONCRETE. 2) THE RIGHT CULVERT OR THE MOST WEST CULVERT IS FLOWING THE WRONG DIRECTION. NEED TO RESET CULVERT SO IT FLOW FROM RIGHT TO LEFT LIKE SWALE PLAN DETAIL STATES. | |||
| U-CROSS CONNECTION | 10/28/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 10/28/2024 1:21:07 PM *** no irrigation-no cross connection | |||
| ELECTRIC - EARLY POWER | 10/03/2024 | APPROVED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 10/3/2024 9:13:56 AM *** 10/3/24: FPL emailed to release power. 9/26/2024 - PREVIOUS INSPECTION NOTES 9/26/24: NOT READY! A FULL RE-INSPECTION WILL BE REQUIRED DUE TO CURRENT CONDITION OF UNITS. Both Units: 1). Attic lights are not safed off as required. (NEC-110.27(a)). 2). Garages are loaded with material and appliances preventing complete inspection. FBC[A] 107.4 Unit A: 3). Kitchen island outlets are blocked by large pieces of material.FBC[A] 107.4 Unit B: 4). Outlets are covered with painting prep paper/tape. FBC[A] 107.4 | |||
| ELECTRIC - EARLY POWER | 09/26/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: *** NOTES ADDED BY RSIMS 9/26/2024 9:05:11 AM *** 9/26/24: NOT READY! A FULL RE-INSPECTION WILL BE REQUIRED DUE TO CURRENT CONDITION OF UNITS. Both Units: 1). Attic lights are not safed off as required. (NEC-110.27(a)). 2). Garages are loaded with material and appliances preventing complete inspection. FBC[A] 107.4 Unit A: 3). Kitchen island outlets are blocked by large pieces of material.FBC[A] 107.4 Unit B: 4). Outlets are covered with painting prep paper/tape. FBC[A] 107.4 | |||
| ROW- PRE-APRON (PRE-POUR) | 09/04/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 9/4/24 CORRECTION REQUIRED MADE AT THE TIME OF THIS INSPECTION. PIPE ELEVATIONS ARE GOOD. READY TO POUR. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. DOUBLE CHECK CULVERT ELEVATIONS At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes, but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. 8/28/2024 - PREVIOUS INSPECTION NOTES 1) THE LEFT DRIVEWAY THE FACE BOARD ALONG EDGE OF THE ROAD IS DOWN NEED TO REFORM SO YOU HAVE THE MINIMUM AMOUNT OF CONCRETE. 2) THE RIGHT CULVERT OR THE MOST WEST CULVERT IS FLOWING THE WRONG DIRECTION. NEED TO RESET CULVERT SO IT FLOW FROM RIGHT TO LEFT LIKE SWALE PLAN DETAIL STATES. | |||
| ROW- PRE-APRON (PRE-POUR) | 08/28/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) THE LEFT DRIVEWAY THE FACE BOARD ALONG EDGE OF THE ROAD IS DOWN NEED TO REFORM SO YOU HAVE THE MINIMUM AMOUNT OF CONCRETE. 2) THE RIGHT CULVERT OR THE MOST WEST CULVERT IS FLOWING THE WRONG DIRECTION. NEED TO RESET CULVERT SO IT FLOW FROM RIGHT TO LEFT LIKE SWALE PLAN DETAIL STATES. | |||
| U - SEWER TIE IN | 07/31/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| GRAVITY SEWER TEST | 07/31/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| FIREWALL DRYWALL NAILING | 06/24/2024 | APPROVED | KSANDOE |
| PEP TANK INSTALLATION REQUEST | 06/24/2024 | APPROVED | CBOWERMASTER |
| Note: 6/21/2024 7:18:16 AM- PREVIOUS INSPECTION NOTES debris pile | |||
| FIREWALL FINAL | 06/20/2024 | APPROVED | KSANDOE |
| Note: 6/18/2024 - PREVIOUS INSPECTION NOTES 6/18/24: 1). Silt fence still needs to be repaired. Noted previously. FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) 2). Draft stop is not sealed properly at roof deck, along CMU wall & in the field at a few areas. Also, drywall needs to extend out to the front gable area as required. (similar to how the back is done). 3). Please clear the overgrowth at the front left side of the property next to permit box to provide clear & safe access to the permit box along with allowing water to flow freely through the swale. | |||
| FIREWALL FINAL | 06/18/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 6/18/24: 1). Silt fence still needs to be repaired. Noted previously. FBC 3307.1 (3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) 2). Draft stop is not sealed properly at roof deck, along CMU wall & in the field at a few areas. Also, drywall needs to extend out to the front gable area as required. (similar to how the back is done). 3). Please clear the overgrowth at the front left side of the property next to permit box to provide clear & safe access to the permit box along with allowing water to flow freely through the swale. | |||
| PEP TANK INSTALLATION REQUEST | 06/18/2024 | Disapproved -FEE REQUIRED | CBOWERMASTER |
| Note: debris pile | |||
| INSULATION | 06/17/2024 | APPROVED | KSANDOE |
| FIREWALL DRYWALL NAILING | 06/14/2024 | APPROVED | AGAETANO |
| Note: 5/15/2024 - PREVIOUS INSPECTION NOTES 5/15/24: 1). Draft stop is not secured properly at 2 areas and is missing screws at 2 areas. 2). Need a dumpster on site and piles of trash/debris cleaned up to make site safe for inspections. 3). Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. (FBC-3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) ___ Also, silt fence is incomplete needs to be finished out to the swale area. 4). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. | |||
| ALL ROUGH | 06/14/2024 | APPROVED | AGAETANO |
| Note: 5/13/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY KSANDOE 5/13/2024 10:08:58 AM *** Please address all issues prior to scheduling inspection *** NOTES ADDED BY KSANDOE 5/13/2024 10:08:13 AM *** Walked Unit B. Framing over doors from garage to dwelling still missing framing at 16"oc Bathtub framing incomplete. Gap over front entry door over 1/4" Dryer vent must be sealed at roof sheathing 5/9/2024 - PREVIOUS INSPECTION NOTES 05-09-2024 1. UniT B (right)14-2 romex has electrical tape and must be replaced comletely. 2. Unit B UFER ground not visible. 3. Unit A (left) dryer vent needs shield plate at top plate. 4. Both units framing over doorways not 16"on center. 5. Energy calcs not on site. Not ready for inspection. A complete inspection is required for next inspection. Ufer ground unit B NOT VISIBLE. 2. Unit B | |||
| FIREWALL DRYWALL NAILING | 05/15/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 5/15/24: 1). Draft stop is not secured properly at 2 areas and is missing screws at 2 areas. 2). Need a dumpster on site and piles of trash/debris cleaned up to make site safe for inspections. 3). Please repair your silt fence barrier immediately & you will need to keep it maintained in original condition per FBC 3307.1 to avoid disapproved inspections with fee going forward. This must be complete prior to scheduling the next inspection. (FBC-3307.1Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work.) ___ Also, silt fence is incomplete needs to be finished out to the swale area. 4). Please move the portable toilet out of the swale area and onto site area to allow water to flow freely through the swale. | |||
| ALL ROUGH | 05/13/2024 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: *** NOTES ADDED BY KSANDOE 5/13/2024 10:08:58 AM *** Please address all issues prior to scheduling inspection *** NOTES ADDED BY KSANDOE 5/13/2024 10:08:13 AM *** Walked Unit B. Framing over doors from garage to dwelling still missing framing at 16"oc Bathtub framing incomplete. Gap over front entry door over 1/4" Dryer vent must be sealed at roof sheathing 5/9/2024 - PREVIOUS INSPECTION NOTES 05-09-2024 1. UniT B (right)14-2 romex has electrical tape and must be replaced comletely. 2. Unit B UFER ground not visible. 3. Unit A (left) dryer vent needs shield plate at top plate. 4. Both units framing over doorways not 16"on center. 5. Energy calcs not on site. Not ready for inspection. A complete inspection is required for next inspection. Ufer ground unit B NOT VISIBLE. 2. Unit B | |||
| ALL ROUGH | 05/09/2024 | Disapproved - NO FEE | AGAETANO |
| Note: 05-09-2024 1. UniT B (right)14-2 romex has electrical tape and must be replaced comletely. 2. Unit B UFER ground not visible. 3. Unit A (left) dryer vent needs shield plate at top plate. 4. Both units framing over doorways not 16"on center. 5. Energy calcs not on site. Not ready for inspection. A complete inspection is required for next inspection. Ufer ground unit B NOT VISIBLE. 2. Unit B | |||
| FRAMING | 05/08/2024 | APPROVED - AS NOTED | AGAETANO |
| Note: Interior framing 05-08-2024 Framing over all doors not 16" on center. Back right framing over door horizontal 2 x 4 not fastened completely. Check at next inspection. | |||
| LATH/BRICK/ WATER BARRIER | 05/08/2024 | APPROVED | AGAETANO |
| WALL SHEATHING | 03/27/2024 | Disapproved - NO FEE | AGAETANO |
| Note: Inspector Notes from Inspection 2460 Truss bracing passed. Interior framing has not begun Framing over front porch has trusses that pass through the fire rated assembly and must be protected. FBC714 3/6/2024 - PREVIOUS INSPECTION NOTES Truss bracing not checked. No Truss packet on site. Framing inspection added 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 All previous items need to be addressed before calling in for re-inspection, stopped inspection 3/1/2024 - PREVIOUS INSPECTION NOTES 3/1/24 - AS PER PREVIOUS REQUEST PLANS, EVEN THOUGH COVERED WITH PLASTIC, NEEDS TO BE CLEAN AND IN NUMERICAL ORDER. I PUT FIRST 6 PAGES IN ORDER. PLEASE REMOVE DRIED MUD AND DIRT FROM PAGES. SIDE NOTE: UNIT "A" HAS 9 RETRO FITTED STRAPS AND UNIT "B" HAS 6..... 2/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: INSPECTION STOPPED! Incomplete Inspection! Only a few quickly identified items listed. 1). Permit box needs attention. Please provide a clean & bound set of plans for the inspectors as required. You will also need a new undamaged truss layout page & engineering packet. FBC-R107.2.1/FBC 107.3.1 2). Fire rated plywood needs to be tightly secured to the trusses, particularly at the front entry. 3). Please check your roof sheathing throughout as there is multiple areas where the sheathing is not properly secured. 4). Truss B2 at entry is missing straps. 5). Off-ridge vents at the rear of the house are cut into the fire rated plywood. You will need to replace these pieces to maintain the integrity of the plywood. (A small fill in patch piece is not permitted). FBC-R302.2 6). Please clean up piles of trash & debris and place in dumpster to make site safe for inspection. Inspector Notes from Inspection 2340 2/15/24: Must be complete prior to next inspection. * Right side unit: Right wall - First 3 windows have mortar beds that exceed the 1/2" max thickness (FBC-R606.3.1) and the last window is not installed properly. Please install a silt fence to keep runoff onto neighboring properties. 2/13/2024 - PREVIOUS INSPECTION NOTES 2/12/2024 - PREVIOUS INSPECTION NOTES 2/12/24 - INSPECTION STOPPED. REBAR MISSING AT CELL LOCATION THROUGHOUT. (DROP DOWNS) CHECK ALL CLEANOUTS, LINTEL COURSE AND CELLS FOR REBAR. Inspector Notes from Inspection 2250 1/5/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in the same condition as when it was inspected. 03-27-2024 Above issue has not been resolved from 03-13-2024. See S1.1 Draft stop details. | |||
| WALL SHEATHING | 03/27/2024 | APPROVED | AGAETANO |
| Note: 3/27/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 2460 Truss bracing passed. Interior framing has not begun Framing over front porch has trusses that pass through the fire rated assembly and must be protected. FBC714 3/6/2024 - PREVIOUS INSPECTION NOTES Truss bracing not checked. No Truss packet on site. Framing inspection added 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 All previous items need to be addressed before calling in for re-inspection, stopped inspection 3/1/2024 - PREVIOUS INSPECTION NOTES 3/1/24 - AS PER PREVIOUS REQUEST PLANS, EVEN THOUGH COVERED WITH PLASTIC, NEEDS TO BE CLEAN AND IN NUMERICAL ORDER. I PUT FIRST 6 PAGES IN ORDER. PLEASE REMOVE DRIED MUD AND DIRT FROM PAGES. SIDE NOTE: UNIT "A" HAS 9 RETRO FITTED STRAPS AND UNIT "B" HAS 6..... 2/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: INSPECTION STOPPED! Incomplete Inspection! Only a few quickly identified items listed. 1). Permit box needs attention. Please provide a clean & bound set of plans for the inspectors as required. You will also need a new undamaged truss layout page & engineering packet. FBC-R107.2.1/FBC 107.3.1 2). Fire rated plywood needs to be tightly secured to the trusses, particularly at the front entry. 3). Please check your roof sheathing throughout as there is multiple areas where the sheathing is not properly secured. 4). Truss B2 at entry is missing straps. 5). Off-ridge vents at the rear of the house are cut into the fire rated plywood. You will need to replace these pieces to maintain the integrity of the plywood. (A small fill in patch piece is not permitted). FBC-R302.2 6). Please clean up piles of trash & debris and place in dumpster to make site safe for inspection. Inspector Notes from Inspection 2340 2/15/24: Must be complete prior to next inspection. * Right side unit: Right wall - First 3 windows have mortar beds that exceed the 1/2" max thickness (FBC-R606.3.1) and the last window is not installed properly. Please install a silt fence to keep runoff onto neighboring properties. 2/13/2024 - PREVIOUS INSPECTION NOTES 2/12/2024 - PREVIOUS INSPECTION NOTES 2/12/24 - INSPECTION STOPPED. REBAR MISSING AT CELL LOCATION THROUGHOUT. (DROP DOWNS) CHECK ALL CLEANOUTS, LINTEL COURSE AND CELLS FOR REBAR. Inspector Notes from Inspection 2250 1/5/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in the same condition as when it was inspected. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/13/2024 | APPROVED - AS NOTED | KSANDOE |
| Note: Truss bracing passed. Interior framing has not begun Framing over front porch has trusses that pass through the fire rated assembly and must be protected. FBC714 3/6/2024 - PREVIOUS INSPECTION NOTES Truss bracing not checked. No Truss packet on site. Framing inspection added 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 All previous items need to be addressed before calling in for re-inspection, stopped inspection 3/1/2024 - PREVIOUS INSPECTION NOTES 3/1/24 - AS PER PREVIOUS REQUEST PLANS, EVEN THOUGH COVERED WITH PLASTIC, NEEDS TO BE CLEAN AND IN NUMERICAL ORDER. I PUT FIRST 6 PAGES IN ORDER. PLEASE REMOVE DRIED MUD AND DIRT FROM PAGES. SIDE NOTE: UNIT "A" HAS 9 RETRO FITTED STRAPS AND UNIT "B" HAS 6..... 2/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: INSPECTION STOPPED! Incomplete Inspection! Only a few quickly identified items listed. 1). Permit box needs attention. Please provide a clean & bound set of plans for the inspectors as required. You will also need a new undamaged truss layout page & engineering packet. FBC-R107.2.1/FBC 107.3.1 2). Fire rated plywood needs to be tightly secured to the trusses, particularly at the front entry. 3). Please check your roof sheathing throughout as there is multiple areas where the sheathing is not properly secured. 4). Truss B2 at entry is missing straps. 5). Off-ridge vents at the rear of the house are cut into the fire rated plywood. You will need to replace these pieces to maintain the integrity of the plywood. (A small fill in patch piece is not permitted). FBC-R302.2 6). Please clean up piles of trash & debris and place in dumpster to make site safe for inspection. Inspector Notes from Inspection 2340 2/15/24: Must be complete prior to next inspection. * Right side unit: Right wall - First 3 windows have mortar beds that exceed the 1/2" max thickness (FBC-R606.3.1) and the last window is not installed properly. Please install a silt fence to keep runoff onto neighboring properties. 2/13/2024 - PREVIOUS INSPECTION NOTES 2/12/2024 - PREVIOUS INSPECTION NOTES 2/12/24 - INSPECTION STOPPED. REBAR MISSING AT CELL LOCATION THROUGHOUT. (DROP DOWNS) CHECK ALL CLEANOUTS, LINTEL COURSE AND CELLS FOR REBAR. Inspector Notes from Inspection 2250 1/5/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in the same condition as when it was inspected. | |||
| ROOF VALLEY & METAL | 03/12/2024 | APPROVED | FWILLIS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/06/2024 | PARTIALLY APPROVED | KSANDOE |
| Note: Truss bracing not checked. No Truss packet on site. Framing inspection added 3/5/2024 - PREVIOUS INSPECTION NOTES 3/5/24 All previous items need to be addressed before calling in for re-inspection, stopped inspection 3/1/2024 - PREVIOUS INSPECTION NOTES 3/1/24 - AS PER PREVIOUS REQUEST PLANS, EVEN THOUGH COVERED WITH PLASTIC, NEEDS TO BE CLEAN AND IN NUMERICAL ORDER. I PUT FIRST 6 PAGES IN ORDER. PLEASE REMOVE DRIED MUD AND DIRT FROM PAGES. SIDE NOTE: UNIT "A" HAS 9 RETRO FITTED STRAPS AND UNIT "B" HAS 6..... 2/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: INSPECTION STOPPED! Incomplete Inspection! Only a few quickly identified items listed. 1). Permit box needs attention. Please provide a clean & bound set of plans for the inspectors as required. You will also need a new undamaged truss layout page & engineering packet. FBC-R107.2.1/FBC 107.3.1 2). Fire rated plywood needs to be tightly secured to the trusses, particularly at the front entry. 3). Please check your roof sheathing throughout as there is multiple areas where the sheathing is not properly secured. 4). Truss B2 at entry is missing straps. 5). Off-ridge vents at the rear of the house are cut into the fire rated plywood. You will need to replace these pieces to maintain the integrity of the plywood. (A small fill in patch piece is not permitted). FBC-R302.2 6). Please clean up piles of trash & debris and place in dumpster to make site safe for inspection. Inspector Notes from Inspection 2340 2/15/24: Must be complete prior to next inspection. * Right side unit: Right wall - First 3 windows have mortar beds that exceed the 1/2" max thickness (FBC-R606.3.1) and the last window is not installed properly. Please install a silt fence to keep runoff onto neighboring properties. 2/13/2024 - PREVIOUS INSPECTION NOTES 2/12/2024 - PREVIOUS INSPECTION NOTES 2/12/24 - INSPECTION STOPPED. REBAR MISSING AT CELL LOCATION THROUGHOUT. (DROP DOWNS) CHECK ALL CLEANOUTS, LINTEL COURSE AND CELLS FOR REBAR. Inspector Notes from Inspection 2250 1/5/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in the same condition as when it was inspected. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/05/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 3/5/24 All previous items need to be addressed before calling in for re-inspection, stopped inspection 3/1/2024 - PREVIOUS INSPECTION NOTES 3/1/24 - AS PER PREVIOUS REQUEST PLANS, EVEN THOUGH COVERED WITH PLASTIC, NEEDS TO BE CLEAN AND IN NUMERICAL ORDER. I PUT FIRST 6 PAGES IN ORDER. PLEASE REMOVE DRIED MUD AND DIRT FROM PAGES. SIDE NOTE: UNIT "A" HAS 9 RETRO FITTED STRAPS AND UNIT "B" HAS 6..... 2/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: INSPECTION STOPPED! Incomplete Inspection! Only a few quickly identified items listed. 1). Permit box needs attention. Please provide a clean & bound set of plans for the inspectors as required. You will also need a new undamaged truss layout page & engineering packet. FBC-R107.2.1/FBC 107.3.1 2). Fire rated plywood needs to be tightly secured to the trusses, particularly at the front entry. 3). Please check your roof sheathing throughout as there is multiple areas where the sheathing is not properly secured. 4). Truss B2 at entry is missing straps. 5). Off-ridge vents at the rear of the house are cut into the fire rated plywood. You will need to replace these pieces to maintain the integrity of the plywood. (A small fill in patch piece is not permitted). FBC-R302.2 6). Please clean up piles of trash & debris and place in dumpster to make site safe for inspection. Inspector Notes from Inspection 2340 2/15/24: Must be complete prior to next inspection. * Right side unit: Right wall - First 3 windows have mortar beds that exceed the 1/2" max thickness (FBC-R606.3.1) and the last window is not installed properly. Please install a silt fence to keep runoff onto neighboring properties. 2/13/2024 - PREVIOUS INSPECTION NOTES 2/12/2024 - PREVIOUS INSPECTION NOTES 2/12/24 - INSPECTION STOPPED. REBAR MISSING AT CELL LOCATION THROUGHOUT. (DROP DOWNS) CHECK ALL CLEANOUTS, LINTEL COURSE AND CELLS FOR REBAR. Inspector Notes from Inspection 2250 1/5/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in the same condition as when it was inspected. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/01/2024 | Disapproved - NO FEE | FWILLIS |
| Note: 3/1/24 - AS PER PREVIOUS REQUEST PLANS, EVEN THOUGH COVERED WITH PLASTIC, NEEDS TO BE CLEAN AND IN NUMERICAL ORDER. I PUT FIRST 6 PAGES IN ORDER. PLEASE REMOVE DRIED MUD AND DIRT FROM PAGES. SIDE NOTE: UNIT "A" HAS 9 RETRO FITTED STRAPS AND UNIT "B" HAS 6..... 2/28/2024 - PREVIOUS INSPECTION NOTES 2/28/24: INSPECTION STOPPED! Incomplete Inspection! Only a few quickly identified items listed. 1). Permit box needs attention. Please provide a clean & bound set of plans for the inspectors as required. You will also need a new undamaged truss layout page & engineering packet. FBC-R107.2.1/FBC 107.3.1 2). Fire rated plywood needs to be tightly secured to the trusses, particularly at the front entry. 3). Please check your roof sheathing throughout as there is multiple areas where the sheathing is not properly secured. 4). Truss B2 at entry is missing straps. 5). Off-ridge vents at the rear of the house are cut into the fire rated plywood. You will need to replace these pieces to maintain the integrity of the plywood. (A small fill in patch piece is not permitted). FBC-R302.2 6). Please clean up piles of trash & debris and place in dumpster to make site safe for inspection. Inspector Notes from Inspection 2340 2/15/24: Must be complete prior to next inspection. * Right side unit: Right wall - First 3 windows have mortar beds that exceed the 1/2" max thickness (FBC-R606.3.1) and the last window is not installed properly. Please install a silt fence to keep runoff onto neighboring properties. 2/13/2024 - PREVIOUS INSPECTION NOTES 2/12/2024 - PREVIOUS INSPECTION NOTES 2/12/24 - INSPECTION STOPPED. REBAR MISSING AT CELL LOCATION THROUGHOUT. (DROP DOWNS) CHECK ALL CLEANOUTS, LINTEL COURSE AND CELLS FOR REBAR. Inspector Notes from Inspection 2250 1/5/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in the same condition as when it was inspected. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/28/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 2/28/24: INSPECTION STOPPED! Incomplete Inspection! Only a few quickly identified items listed. 1). Permit box needs attention. Please provide a clean & bound set of plans for the inspectors as required. You will also need a new undamaged truss layout page & engineering packet. FBC-R107.2.1/FBC 107.3.1 2). Fire rated plywood needs to be tightly secured to the trusses, particularly at the front entry. 3). Please check your roof sheathing throughout as there is multiple areas where the sheathing is not properly secured. 4). Truss B2 at entry is missing straps. 5). Off-ridge vents at the rear of the house are cut into the fire rated plywood. You will need to replace these pieces to maintain the integrity of the plywood. (A small fill in patch piece is not permitted). FBC-R302.2 6). Please clean up piles of trash & debris and place in dumpster to make site safe for inspection. Inspector Notes from Inspection 2340 2/15/24: Must be complete prior to next inspection. * Right side unit: Right wall - First 3 windows have mortar beds that exceed the 1/2" max thickness (FBC-R606.3.1) and the last window is not installed properly. Please install a silt fence to keep runoff onto neighboring properties. 2/13/2024 - PREVIOUS INSPECTION NOTES 2/12/2024 - PREVIOUS INSPECTION NOTES 2/12/24 - INSPECTION STOPPED. REBAR MISSING AT CELL LOCATION THROUGHOUT. (DROP DOWNS) CHECK ALL CLEANOUTS, LINTEL COURSE AND CELLS FOR REBAR. Inspector Notes from Inspection 2250 1/5/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in the same condition as when it was inspected. | |||
| FOUND SURVEY APPROVED (OFFICE) | 02/27/2024 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 02/15/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 2/15/24: Must be complete prior to next inspection. * Right side unit: Right wall - First 3 windows have mortar beds that exceed the 1/2" max thickness (FBC-R606.3.1) and the last window is not installed properly. Please install a silt fence to keep runoff onto neighboring properties. 2/13/2024 - PREVIOUS INSPECTION NOTES 2/12/2024 - PREVIOUS INSPECTION NOTES 2/12/24 - INSPECTION STOPPED. REBAR MISSING AT CELL LOCATION THROUGHOUT. (DROP DOWNS) CHECK ALL CLEANOUTS, LINTEL COURSE AND CELLS FOR REBAR. Inspector Notes from Inspection 2250 1/5/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in the same condition as when it was inspected. | |||
| TIE BEAM / LINTEL | 02/13/2024 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: 2/12/2024 - PREVIOUS INSPECTION NOTES 2/12/24 - INSPECTION STOPPED. REBAR MISSING AT CELL LOCATION THROUGHOUT. (DROP DOWNS) CHECK ALL CLEANOUTS, LINTEL COURSE AND CELLS FOR REBAR. Inspector Notes from Inspection 2250 1/5/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in the same condition as when it was inspected. | |||
| TIE BEAM / LINTEL | 02/12/2024 | Disapproved -FEE REQUIRED | FWILLIS |
| Note: 2/12/24 - INSPECTION STOPPED. REBAR MISSING AT CELL LOCATION THROUGHOUT. (DROP DOWNS) CHECK ALL CLEANOUTS, LINTEL COURSE AND CELLS FOR REBAR. Inspector Notes from Inspection 2250 1/5/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in the same condition as when it was inspected. | |||
| MONOLITHIC SLAB | 01/05/2024 | APPROVED - AS NOTED | RSIMS |
| Note: 1/5/24: At the time of Inspection all of the Florida Building Code & City Code requirements along with any Plan requirements related to this inspection have been met. It is the sole responsibility of the Contractor to assure that everything remains in the same condition as when it was inspected. | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/29/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 11/08/2023 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 03/03/2025 | 03/05/2025 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| MECH | HOLD | 12/10/2024 | 12/13/2024 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Duct layout needs to be signed by listed subcontractor | |||
| BADMIN | INFORMATION | 11/08/2024 | 11/08/2024 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM RENAME TO FINAL SURVEY.PDF | |||
| BADMIN | INFORMATION | 11/08/2024 | 11/08/2024 |
| Note: Marked INFORMATION By: SCOTT THOMAS - (386)986-3780 - STHOMAS@PALMCOASTGOV.COM NOC EXPIRED. CAN NOT SCHEDULE FINAL SURVEY | |||
| ENGIN1 | COMPLETE | 02/26/2024 | 02/27/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 02/26/2024 | 02/26/2024 |
| Note: Released By: LIBBY MUSGROVE - (386)986-3780 - LMUSGROVE@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/11/2023 | 09/11/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 09/11/2023 | 09/12/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/08/2023 | 09/08/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 08/31/2023 | 09/05/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/28/2023 | 09/01/2023 |
| Note: Held By: JPI 1.Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet. hour not approved | |||
| CUSVC | COMPLETE | 08/28/2023 | 08/30/2023 |
| Note: Released By: LISA ASBILL - - lasbill@palmcoastgov.com | |||
| ELEC | COMPLETE | 08/28/2023 | 08/31/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/28/2023 | 08/28/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 08/28/2023 | 08/31/2023 |
| LOCATE | COMPLETE | 08/28/2023 | 09/05/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/28/2023 | 09/01/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/28/2023 | 09/07/2023 |
| Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | HOLD | 08/28/2023 | 08/29/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Elevation Plan: the windows facing the ROW are missing banding please add banding to the windows facing the front of the home | |||
| SWALE | COMPLETE | 08/28/2023 | 10/17/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/08/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/08/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/08/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/08/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/08/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/08/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/08/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/08/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/08/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 08/08/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 08/08/2025 |
| CONTRACTOR CHANGE | ¤20.00 | 08/08/2025 |
| REINSPECTION FEE | ¤40.00 | 08/08/2025 |
| SW ENG REINSPECTION 20 | ¤20.00 | 08/08/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 08/08/2025 |
| UTILITY PEP REINSPECTION | ¤40.00 | 08/08/2025 |
| SEWER INSPECTION | ¤25.00 | 09/18/2023 |
| SEWER CAPITAL FACILITY | ¤10,689.64 | 09/18/2023 |
| WATER CAPITAL FACILITY FEE | ¤7,847.76 | 09/18/2023 |
| SITE PLAN 30 | ¤30.00 | 09/18/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/18/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/18/2023 |
| SURCHARGE FS 533.721 | ¤7.21 | 09/18/2023 |
| SURCHARGE - FS 468.631 | ¤10.82 | 09/18/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/18/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 09/18/2023 |
| SW ENG PRE APRON | ¤30.00 | 09/18/2023 |
| WATER- TURN ON | ¤50.00 | 09/18/2023 |
| ADJUSTMENT 50% | (¤721.00) | 09/18/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/18/2023 |
| INSPECTION - RESIDENTIAL | ¤1,100.00 | 09/18/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤312.00 | 09/18/2023 |
| FC IMPACT FEE EMS | ¤124.00 | 09/18/2023 |
| IMPACT FEE FIRE | ¤841.04 | 09/18/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 09/18/2023 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 09/18/2023 |
| IMPACT FEE PARKS | ¤3,538.30 | 09/18/2023 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 09/18/2023 |
| IMPACT FEE TRANSPORTATION | ¤2,812.00 | 09/18/2023 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 09/18/2023 |
| CONNECTION FEES | ¤2,332.52 | 09/18/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤41,871.29 |