I want to search for...
Permit #2023081587
Permit Details
Status: COED
| Parcel Id: 07-11-31-7035-01370-0170 |
| CONDITIONED SPACE: 1263 sqft |
| GARAGE: 471 sqft |
| OPENED PORCH (WITH ROOF) : 63 sqft |
| Total Square Footage: 1797 sqft |
| Block: 01370 |
| Subdivision: 2172 - SECTION 35-BELLE TERRE |
| Job Phone: 386-931-2131 |
| Location Address: 158 BIRD OF PARADISE DR |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/20/2023 |
| NOC: RECORDED |
| Applicant name: FLAGLER HABITAT |
| Owner: FLAGLER HABITAT FOR HUMANITY INC |
|
Address PO BOX 187 BUNNELL, FL 32110 |
| Lot: 0170 |
| Contracted Stated Job Value: ¤275,000.00 |
| Job Description: single family residence |
| Type: CN |
Contractor
FLAGLER HABITAT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
2 WEST MOODY BLVD BUNNELL, FL 32110 |
HABITAT | 386-931-2131 |
Sub Contractors
GARY LLOYD SHEFFIELD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
48 EAGLE LAKES DRIVE FLAGLER BEACH, FL 32136 |
CAC048127 (Exp: 08/31/2026) | 386-597-3280 |
JONATHAN M PEARSON
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
209 N FORSYTH ST BUNNELL, FL 32110 |
CFC1425941 (Exp: 08/31/2026) | 386-597-0944 | 386-437-4996 |
RICHARD H SIMMONS JR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
PO BOX 1963 BUNNELL, FL 32110 |
ES12001217 (Exp: 08/31/2026) | 386-437-0607 | 386-437-1847 |
MICHAEL A PENAGOS
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3321 GLENSHANE WAY ORMOND BEACH, FL 32174 |
CCC1330460 (Exp: 08/31/2026) | 386-569-9133 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 04/22/2024 | FINAL APPROVED | JSTEWART |
| ROW - FINAL APRON (AFTER POUR) | 04/22/2024 | APPROVED | PFLANAGAN |
| ROW - STORMWATER FINAL | 04/22/2024 | APPROVED | PFLANAGAN |
| U -UTILITY RESIDENTIAL FINAL | 04/22/2024 | FINAL APPROVED | DHANEY |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/19/2024 | APPROVED | EMADISON |
| Note: ** 04/19/24 AS NOTED BY INSPECTOR FLANNAGEN CHANGES WERE MADE WITH REVISED SITE PLAN TO MATCH FINAL SURVEY. ___________________________________________________________________________________________________________________ NOTE TO INSPECTOR MEET WITH JOHN ON 4/11/24 ABOUT THE FINAL SURVEY AND I AM GOING TO LET HIM DRAIN WATER TO THE BACK RESERVE PARCEL BUT HE NEEDS TO HAVE AN APPROVED SITE PLAN THAT SHOWS IT DRAINING THERE. ALSO HE IS GOUNG TO HAVE SWA FIX ALL OTHER ISSUES WITH THE SURVEY. ---------------------------------------------------------------------------------- 4/4/2024 - PREVIOUS INSPECTION NOTES 1) THE RIGHT INVERT ON THE CULVERT IS OUT OF TOLERANCE WITH THE SWALE PLAN DETAIL. Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan. 2) THE FINAL SURVEY STATES THAT ALOT OF THE BACK YARDS DRAINAGE IS FLOW TO THE RESERVE PARCEL BEHIND YOUR LOT SITE PLAN SHOWS ALL WATER FLOWING FROM THE BACK TO THE FRONT ROADSIDE SWALE. Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale or drainage feature, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. 3) THE FINAL SURVEY STATES THAT THIS IS AN CONCRETE BLOCK STRUCTURE BUT IT IS A WOOD FRAME HOUSE. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 04/19/2024 | APPROVED | EMADISON |
| Note: ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. | |||
| ROW- PROJECT STATUS | 04/11/2024 | APPROVED | PFLANAGAN |
| Note: TALKED WITH JOHN ABOUT THE FINAL SURVEY I AM GOING TO LET HIM TO DRAIN WATER IN THE BACK YARD TO THE RESERVE BUT NEEDS TO UPDATE THE SITE PLAN. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/04/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) THE RIGHT INVERT ON THE CULVERT IS OUT OF TOLERANCE WITH THE SWALE PLAN DETAIL. Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan. 2) THE FINAL SURVEY STATES THAT ALOT OF THE BACK YARDS DRAINAGE IS FLOW TO THE RESERVE PARCEL BEHIND YOUR LOT SITE PLAN SHOWS ALL WATER FLOWING FROM THE BACK TO THE FRONT ROADSIDE SWALE. Section 300.01.Identify how the rear yard will be drained. The rear yard is required to drain to the front yard swale or drainage feature, unless the Topographic Survey/Lot Grading Plan demonstrates a rear yard drainage system with an appropriate outfall. 3) THE FINAL SURVEY STATES THAT THIS IS AN CONCRETE BLOCK STRUCTURE BUT IT IS A WOOD FRAME HOUSE. | |||
| U-CROSS CONNECTION | 03/22/2024 | APPROVED | DHANEY |
| ELECTRIC - EARLY POWER | 03/01/2024 | APPROVED - AS NOTED | JSTEWART |
| Note: 3/1/24- Authorize release of email to FPL @ 10:17a | |||
| ROW- PRE-APRON (PRE-POUR) | 02/14/2024 | APPROVED | GBERTOLA |
| Note: AT THE TIME OF THE INSPECTION, THE CULVERT PIPE IS GOOD AND READY TO POUR; THE BUILDER SHOULD DOUBLE-CHECK THE CULVERT ELEVATIONS BEFORE POURING. MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300E RESIDENTIAL CULVERT DETAIL | |||
| U - SEWER TIE IN | 02/13/2024 | APPROVED | MGIBSON |
| GRAVITY SEWER TEST | 02/13/2024 | APPROVED | MGIBSON |
| PEP TANK INSTALLATION REQUEST | 01/25/2024 | APPROVED | BVITALE |
| INSULATION | 01/18/2024 | APPROVED | JSTEWART |
| ALL ROUGH | 01/12/2024 | APPROVED - AS NOTED | JSTEWART |
| Note: 1/12/24- Please install breaker panel Chase for protection of romex wires and firestopping. Please relocate Plex water supply lines running over ceiling can Light Locations (Multiple). Will check at Insulation. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/04/2024 | APPROVED | JSTEWART |
| Note: 12/21/2023 - PREVIOUS INSPECTION NOTES NO READABLE APPROVED PLANS IN CONSTRUCTION BOX. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL. CANNOT INSPECT WITH MATERIAL ON THE FLOOR BLOCKING BOTTOM PLATES AND OTHER AREAS. ESPECIALLY IN THE GARAGE. REMOVE WOOD SCATTERED ON THE FLOOR THROUGHOUT TO PREVENT TRIP HAZARDS. ALSO HVAC WORKER WITH TOOLS AND MATERIAL BLOCKING AREAS. | |||
| ROOF VALLEY & METAL | 01/03/2024 | APPROVED | JSTEWART |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 12/21/2023 | Disapproved - NO FEE | FWILLIS |
| Note: NO READABLE APPROVED PLANS IN CONSTRUCTION BOX. DOCUMENTS MUST BE APPROVED AND KEPT ON SITE 107.3,1. AND SHALL BE OPEN TO INSPECTION BY THE BUILDING OFFICIAL. CANNOT INSPECT WITH MATERIAL ON THE FLOOR BLOCKING BOTTOM PLATES AND OTHER AREAS. ESPECIALLY IN THE GARAGE. REMOVE WOOD SCATTERED ON THE FLOOR THROUGHOUT TO PREVENT TRIP HAZARDS. ALSO HVAC WORKER WITH TOOLS AND MATERIAL BLOCKING AREAS. | |||
| LATH/BRICK/ WATER BARRIER | 12/08/2023 | APPROVED | KSANDOE |
| WINDOW NAILING | 12/08/2023 | APPROVED | KSANDOE |
| WALL SHEATHING | 12/05/2023 | APPROVED | FWILLIS |
| FOUND SURVEY APPROVED (OFFICE) | 12/04/2023 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 11/02/2023 | APPROVED | JSTEWART |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/27/2023 | APPROVED | MGIBSON |
| ELECTRIC TEMP POLE | 10/11/2023 | APPROVED - AS NOTED | JSTEWART |
| Note: 10/11/23- Authorize release of email to FPL @ 12:38p | |||
| WATER METER INSTALLATION REQUEST | 09/26/2023 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| ENGIN1 | COMPLETE | 04/17/2024 | 04/18/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 04/17/2024 | 04/18/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 04/17/2024 | 04/17/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | INFORMATION | 12/07/2023 | 12/07/2023 |
| Note: Marked INFORMATION By: BARBIE BEMBRY - (386)986-3780 - BUILDINGDIVISION@PALMCOASTGOV.COM the red submit button will always be lit if the plan review is in the status where you can submit something. If it is not (under review), you wont see it. | |||
| BLD | COMPLETE | 12/04/2023 | 12/06/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/01/2023 | 12/04/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/01/2023 | 12/01/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 09/14/2023 | 09/15/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 09/12/2023 | 09/14/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Electrical load calculations do not match the living space of the house. NEC 2017 220 | |||
| MECH | COMPLETE | 09/12/2023 | 09/12/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/12/2023 | 09/13/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | HOLD | 08/31/2023 | 09/06/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Provide updated Florida product approval number for underlayment on roofing worksheet and product approval worksheet from 2020 code cycle | |||
| CUSVC | COMPLETE | 08/31/2023 | 09/06/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | HOLD | 08/31/2023 | 09/05/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Submit electric load calcs 2. Need light and switch by exterior back door. NEC 2017 210.70 | |||
| ENGIN1 | COMPLETE | 08/31/2023 | 08/31/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 08/31/2023 | 09/05/2023 |
| LOCATE | COMPLETE | 08/31/2023 | 09/05/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/31/2023 | 09/05/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show R19 insulation in walls. Energy Calcs say R13. Revise to match. 2. Energy Calcs need to be signed by the owner/ owner agent below the preparer per R103.1.1.2 FBC Energy Conservation 2020 7Th edition | |||
| SW1 | COMPLETE | 08/31/2023 | 09/07/2023 |
| Note: Released By: FRANK SLADISH - - FSLADISH@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/31/2023 | 09/01/2023 |
| Note: Released By: SCOTT THOMAS - - STHOMAS@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 08/31/2023 | 10/20/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG REINSPECTION 20 | ¤20.00 | 04/23/2024 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/20/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/20/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 09/20/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 09/20/2023 |
| SEWER CREDIT | (¤2,405.43) | 09/20/2023 |
| SEWER INSPECTION | ¤25.00 | 09/20/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 09/20/2023 |
| WATER CREDIT | (¤60.31) | 09/20/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 09/20/2023 |
| SITE PLAN 30 | ¤30.00 | 09/20/2023 |
| WATER- TURN ON | ¤25.00 | 09/20/2023 |
| ADJUSTMENT 50% | (¤500.38) | 09/20/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/20/2023 |
| INSPECTION - RESIDENTIAL | ¤756.25 | 09/20/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤214.50 | 09/20/2023 |
| CONNECTION FEES | ¤1,166.26 | 09/20/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 09/20/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 09/20/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 09/20/2023 |
| IMPACT FEE FIRE | ¤420.52 | 09/20/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 09/20/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 09/20/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 09/20/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 09/20/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/20/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 09/20/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 09/20/2023 |
| SURCHARGE FS 533.721 | ¤5.00 | 09/20/2023 |
| SURCHARGE - FS 468.631 | ¤7.51 | 09/20/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/20/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 09/20/2023 |
| SW ENG PRE APRON | ¤30.00 | 09/20/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤13,506.77 |