Permit #2023081588
Permit Details
Status: COED
| Parcel Id: 07-11-31-7021-00040-0250 |
| CONDITIONED SPACE: 2956 sqft |
| GARAGE: 888 sqft |
| OPENED PORCH (WITH ROOF) : 270 sqft |
| Total Square Footage: 4114 sqft |
| Block: 00040 |
| Subdivision: 2186 - SECTION 21-WYNNFIELD |
| Job Phone: 386-237-5837 |
| Location Address: 104 WELLWOOD LN |
| Type: DU - DUPLEX |
| Issue Date: 09/18/2023 |
| NOC: RECORDED |
| Applicant name: MARSEL GILMANSHIN |
| Owner: LOURI SINKEVITCH AND TATYANA SEMENAVA |
|
Address 412 OCEAN VIEW AVE 5C BROOKLYN, NY 11235 |
| Lot: 0250 |
| Contracted Stated Job Value: ¤400,000.00 |
| Job Description: duplex |
| Type: CN |
Contractor
GILMANS DEVELOPMENT CORP
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4873 PALM COAST PARKWAY NW #4 PALM COAST, FL 32137 |
CBC1263180 (Exp: 08/31/2026) | 386-237-5837 |
Sub Contractors
MAXIM BUDNIK
| Status | Location Address | State License Number | Phone |
| ACTIVE |
9788 HALSEY RD JACKSONVILLE, FL 32246 |
EC13007415 (Exp: 08/31/2026) | 904-509-7306 |
MAXIM BUDNIK
| Status | Location Address | State License Number |
| ACTIVE |
3 WAVECREST PL PALM COAST, FL 32164 |
CAC1818445 (Exp: 08/31/2026) |
GLEN WILLIAM KEHLE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
P. O. Box 353511 BUNNELL, FL 32110 |
CFC057241 (Exp: 08/31/2026) | (386) 447-4249 | (386) 437-8488 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 10/14/2024 | FINAL APPROVED | MKRASKI |
| Note: | |||
| BLD - BUILDING FINAL | 09/30/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 9/30/24 1. E-cals do not match equipment installed, revision required and must be approved by Building Dept. FBC [A] 107.4 2. Microwaves require breker lock (built ins) NEC 422.16 3. Kitchen outlets not GFCI protected (B-side) NEC 210.8 4. Back flow preventer missing on hose bib (B-side) FBCR P2903.8.5 5. Loose outlet in front bedroom NEC 406.4 | |||
| U-CROSS CONNECTION | 09/30/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 9/30/2024 11:17:33 AM *** no irr-no cross connection | |||
| ROW - FINAL INSPECTION | 09/24/2024 | APPROVED | TPOLACEK |
| Note: 09/24/24 TPOLACEK** CORRECTIONS HAVE BEEN MADE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/20/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE ALL MULCH FROM THE VACANT LOTS AND PUT SEED AND STRAW ON ALL BARE AREAS. 2) NEED TO REMOVE ALL TRASH AND CONSTRCTION DEBRIS FROM VACANT LOTS. -------------------------------------------------------------------------- 9/17/2024 - PREVIOUS INSPECTION NOTES 09/17/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 09/10/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. APPROVING FIELD INSPECTION AS NOTED. | |||
| ROW - FINAL INSPECTION | 09/20/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) NEED TO REMOVE ALL MULCH FROM THE VACANT LOTS AND PUT SEED AND STRAW ON ALL BARE AREAS. 2) NEED TO REMOVE ALL TRASH AND CONSTRCTION DEBRIS FROM VACANT LOTS. -------------------------------------------------------------------------- 9/17/2024 - PREVIOUS INSPECTION NOTES 09/17/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 09/10/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. APPROVING FIELD INSPECTION AS NOTED. | |||
| BLD - BUILDING FINAL | 09/20/2024 | CANCELLED BY APPLICANT | MKRASKI |
| ROW - FINAL APRON (AFTER POUR) | 09/20/2024 | APPROVED | PFLANAGAN |
| Note: CORRECTIONS MADE ------------------------------------------------------------------------ 9/17/2024 - PREVIOUS INSPECTION NOTES 09/17/24 TPOLACEK** YOU MUST CLEAN OUT DIRT AND SEDIMENT FROM CULVERT | |||
| ROW - FINAL APRON (AFTER POUR) | 09/17/2024 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 09/17/24 TPOLACEK** YOU MUST CLEAN OUT DIRT AND SEDIMENT FROM CULVERT | |||
| U -UTILITY RESIDENTIAL FINAL | 09/17/2024 | FINAL APPROVED | LFITZGERALD |
| ROW - FINAL INSPECTION | 09/17/2024 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 09/17/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 09/10/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. APPROVING FIELD INSPECTION AS NOTED. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/10/2024 | APPROVED | TPOLACEK |
| Note: 09/10/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. APPROVING FIELD INSPECTION AS NOTED. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. 7/23/2024 - PREVIOUS INSPECTION NOTES 07/23/24 TPOLACEK*** YOU MUST FIRST SUBMIT AND A FINAL SURVEY AND THE FINAL SURVEY MUST BE APPROVED (IN OFFICE) BEFORE REQUESTING A FIELD SURVEY. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/10/2024 | APPROVED | TPOLACEK |
| FIREWALL FINAL | 09/03/2024 | APPROVED | MKRASKI |
| Note: New inspection due to canceled inspection Inspector Notes from Inspection 2443 5/2/24 Draft stop approved and Ceiling and party wall all hung with 5/8'' type X board approved 3/22/2024 - PREVIOUS INSPECTION NOTES 3/21/24: This is a partial approval for the draft stop wall in the attic space above the ceiling since the entire ceiling will be covered with 5/8" type X as required on the plans. The second part of the inspection will be for that fire rated drywall. | |||
| ELECTRIC - EARLY POWER | 08/20/2024 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 9:30am | |||
| ELECTRIC - EARLY POWER | 08/19/2024 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: R319.1 Missing Address Rear porch, left unit, outlet not safed off | |||
| WINDOW NAILING | 07/23/2024 | APPROVED | MKRASKI |
| ROW FIELD SURVEY /GRADING CERTIFICATION | 07/23/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: 07/23/24 TPOLACEK*** YOU MUST FIRST SUBMIT AND A FINAL SURVEY AND THE FINAL SURVEY MUST BE APPROVED (IN OFFICE) BEFORE REQUESTING A FIELD SURVEY. | |||
| ROW- PRE-APRON (PRE-POUR) | 06/05/2024 | APPROVED | PFLANAGAN |
| Note: CORRECTIONS MADE IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. --------------------------------------------------------------------------------------- 5/31/2024 - PREVIOUS INSPECTION NOTES 05/31/24 TPOLACEK*** BOTH CULVERT PIPES ARE BACKPITCHED BY OVER .03, RIGHT SIDE CULVERT IS .10 OVER THE TOLERNACE ALLOWED, RIGHT SIDE PIPE IS NOT 8' FROM EDGE OF EXISTING ROADWAY. PLEASE MAKE CORRECTIONS BEFORE REQUESTING ANOTHER INSPECTION. 5/30/2024 - PREVIOUS INSPECTION NOTES 05/30/24 TPOLACEK*** MET WITH MARSEL AND EXPLAINED WHAT HE NEEDS TO DO TO PASS INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/20/2024 - PREVIOUS INSPECTION NOTES 05/20/24 TPOLACEK*** NOT READY FOR INSPECTION, I SHOT THE PIPE ON THE LEFT AND IT WAS .20 OUT OF TOLERNACE I DID NOT SHOOT PIPE ON THE RIGHT AS SITE IS NOT READY. FORM BOARDS ARE NOT SET TO CULVERT DIAGRAM, PIPE IS NOT BURIED 1/2 WAYAND BASE IS NOT GRADED LEVEL. PLEASE SEE ATTACHED PHOTOS | |||
| ROW- PRE-APRON (PRE-POUR) | 06/03/2024 | CANCELLED BY APPLICANT | WEB |
| Note: 5/31/2024 - PREVIOUS INSPECTION NOTES 05/31/24 TPOLACEK*** BOTH CULVERT PIPES ARE BACKPITCHED BY OVER .03, RIGHT SIDE CULVERT IS .10 OVER THE TOLERNACE ALLOWED, RIGHT SIDE PIPE IS NOT 8' FROM EDGE OF EXISTING ROADWAY. PLEASE MAKE CORRECTIONS BEFORE REQUESTING ANOTHER INSPECTION. 5/30/2024 - PREVIOUS INSPECTION NOTES 05/30/24 TPOLACEK*** MET WITH MARSEL AND EXPLAINED WHAT HE NEEDS TO DO TO PASS INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/20/2024 - PREVIOUS INSPECTION NOTES 05/20/24 TPOLACEK*** NOT READY FOR INSPECTION, I SHOT THE PIPE ON THE LEFT AND IT WAS .20 OUT OF TOLERNACE I DID NOT SHOOT PIPE ON THE RIGHT AS SITE IS NOT READY. FORM BOARDS ARE NOT SET TO CULVERT DIAGRAM, PIPE IS NOT BURIED 1/2 WAYAND BASE IS NOT GRADED LEVEL. PLEASE SEE ATTACHED PHOTOS | |||
| ROW- PRE-APRON (PRE-POUR) | 05/31/2024 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 05/31/24 TPOLACEK*** BOTH CULVERT PIPES ARE BACKPITCHED BY OVER .03, RIGHT SIDE CULVERT IS .10 OVER THE TOLERNACE ALLOWED, RIGHT SIDE PIPE IS NOT 8' FROM EDGE OF EXISTING ROADWAY. PLEASE MAKE CORRECTIONS BEFORE REQUESTING ANOTHER INSPECTION. 5/30/2024 - PREVIOUS INSPECTION NOTES 05/30/24 TPOLACEK*** MET WITH MARSEL AND EXPLAINED WHAT HE NEEDS TO DO TO PASS INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/20/2024 - PREVIOUS INSPECTION NOTES 05/20/24 TPOLACEK*** NOT READY FOR INSPECTION, I SHOT THE PIPE ON THE LEFT AND IT WAS .20 OUT OF TOLERNACE I DID NOT SHOOT PIPE ON THE RIGHT AS SITE IS NOT READY. FORM BOARDS ARE NOT SET TO CULVERT DIAGRAM, PIPE IS NOT BURIED 1/2 WAYAND BASE IS NOT GRADED LEVEL. PLEASE SEE ATTACHED PHOTOS | |||
| ROW- PRE-APRON (PRE-POUR) | 05/30/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: 05/30/24 TPOLACEK*** MET WITH MARSEL AND EXPLAINED WHAT HE NEEDS TO DO TO PASS INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/20/2024 - PREVIOUS INSPECTION NOTES 05/20/24 TPOLACEK*** NOT READY FOR INSPECTION, I SHOT THE PIPE ON THE LEFT AND IT WAS .20 OUT OF TOLERNACE I DID NOT SHOOT PIPE ON THE RIGHT AS SITE IS NOT READY. FORM BOARDS ARE NOT SET TO CULVERT DIAGRAM, PIPE IS NOT BURIED 1/2 WAYAND BASE IS NOT GRADED LEVEL. PLEASE SEE ATTACHED PHOTOS | |||
| ROW- PRE-APRON (PRE-POUR) | 05/20/2024 | Disapproved -FEE REQUIRED | TPOLACEK |
| Note: 05/20/24 TPOLACEK*** NOT READY FOR INSPECTION, I SHOT THE PIPE ON THE LEFT AND IT WAS .20 OUT OF TOLERNACE I DID NOT SHOOT PIPE ON THE RIGHT AS SITE IS NOT READY. FORM BOARDS ARE NOT SET TO CULVERT DIAGRAM, PIPE IS NOT BURIED 1/2 WAYAND BASE IS NOT GRADED LEVEL. PLEASE SEE ATTACHED PHOTOS | |||
| FIREWALL FINAL | 05/15/2024 | CANCELLED BY APPLICANT | WEB |
| Note: Inspector Notes from Inspection 2443 5/2/24 Draft stop approved and Ceiling and party wall all hung with 5/8'' type X board approved 3/22/2024 - PREVIOUS INSPECTION NOTES 3/21/24: This is a partial approval for the draft stop wall in the attic space above the ceiling since the entire ceiling will be covered with 5/8" type X as required on the plans. The second part of the inspection will be for that fire rated drywall. | |||
| U - SEWER TIE IN | 05/10/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: 5/9/2024 - PREVIOUS INSPECTION NOTES TAP NOT MADE. THIS WAS A VIRTUAL INSPECTION | |||
| U - SEWER TIE IN | 05/09/2024 | Disapproved - NO FEE | MGIBSON |
| Note: TAP NOT MADE | |||
| GRAVITY SEWER TEST | 05/08/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: GRAVITY SEWER IS APPROVED TAP NOT MADE. WHEN SEWER TIE IN IS MADE SCHEDUALE FOR THIS INSPECTION ONLY | |||
| FIREWALL DRYWALL NAILING | 05/02/2024 | APPROVED - AS NOTED | MKRASKI |
| Note: 5/2/24 Draft stop approved and Ceiling and party wall all hung with 5/8'' type X board approved 3/22/2024 - PREVIOUS INSPECTION NOTES 3/21/24: This is a partial approval for the draft stop wall in the attic space above the ceiling since the entire ceiling will be covered with 5/8" type X as required on the plans. The second part of the inspection will be for that fire rated drywall. | |||
| FIREWALL FINAL | 04/30/2024 | PARTIALLY APPROVED | MKRASKI |
| Note: 4/30/24 1. Check draft stop extends tp top of soffit (leave soffit off untill after fire wall final is called back in 2. Draft stop in attic ok, call back in once ceiling and party wall are hung 4/25/2024 - PREVIOUS INSPECTION NOTES 4/25/24 Draft stop must extend down to top of soffit 4/24/2024 - PREVIOUS INSPECTION NOTES Plans call for firewall to be 5/8'' X-type on the ceiling, only draft stop has been installed **** all penitrations and opening need to be sealed in draft stop | |||
| FIREWALL FINAL | 04/25/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 4/25/24 Draft stop must extend down to top of soffit 4/24/2024 - PREVIOUS INSPECTION NOTES Plans call for firewall to be 5/8'' X-type on the ceiling, only draft stop has been installed **** all penitrations and opening need to be sealed in draft stop | |||
| FIREWALL FINAL | 04/24/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: Plans call for firewall to be 5/8'' X-type on the ceiling, only draft stop has been installed **** all penitrations and opening need to be sealed in draft stop | |||
| INSULATION | 04/17/2024 | APPROVED | JSTEWART |
| Note: 4/16/2024 - PREVIOUS INSPECTION NOTES 1. Insulation board missing on A side near front door 2. Horizonal romex runs in kitchen wall needs draft stop, Both sides | |||
| INSULATION | 04/16/2024 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Insulation board missing on A side near front door 2. Horizonal romex runs in kitchen wall needs draft stop, Both sides | |||
| ALL ROUGH | 04/11/2024 | APPROVED - AS NOTED | MKRASKI |
| Note: 4/11/24 1. Garage door bucks required to have one more anchor above opening in both units 2. SGD opening needs to be sealed (door on back order) Added window nailing inspection 4/9/2024 - PREVIOUS INSPECTION NOTES 4/9/24 Make ALL repairs and have detail uploaded from previous and approved throigh Building Dept. before calling in re-inspection. 4/5/2024 - PREVIOUS INSPECTION NOTES Need to see detail for roof sheathing inre fireboard penetration. Missing garage door bucking Missing garage dwelling entry door Missing rear slider Window anchors must be countersunk 4/1/2024 - PREVIOUS INSPECTION NOTES 1. All metaliuc boxes are required to be bonded 2. Garage door to home missing 3. Windows missing anchors check all 4. E-cals dont match what is installed reviasion or correction required 5. CMU insulation is only rated for R3.2, cals require R4.1 Stopped inspection, not ready compleet re-inspection required | |||
| ALL ROUGH | 04/09/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 4/9/24 Make ALL repairs and have detail uploaded from previous and approved throigh Building Dept. before calling in re-inspection. 4/5/2024 - PREVIOUS INSPECTION NOTES Need to see detail for roof sheathing inre fireboard penetration. Missing garage door bucking Missing garage dwelling entry door Missing rear slider Window anchors must be countersunk 4/1/2024 - PREVIOUS INSPECTION NOTES 1. All metaliuc boxes are required to be bonded 2. Garage door to home missing 3. Windows missing anchors check all 4. E-cals dont match what is installed reviasion or correction required 5. CMU insulation is only rated for R3.2, cals require R4.1 Stopped inspection, not ready compleet re-inspection required | |||
| ALL ROUGH | 04/05/2024 | Disapproved -FEE REQUIRED | KSANDOE |
| Note: Need to see detail for roof sheathing inre fireboard penetration. Missing garage door bucking Missing garage dwelling entry door Missing rear slider Window anchors must be countersunk 4/1/2024 - PREVIOUS INSPECTION NOTES 1. All metaliuc boxes are required to be bonded 2. Garage door to home missing 3. Windows missing anchors check all 4. E-cals dont match what is installed reviasion or correction required 5. CMU insulation is only rated for R3.2, cals require R4.1 Stopped inspection, not ready compleet re-inspection required | |||
| LATH/BRICK/ WATER BARRIER | 04/05/2024 | APPROVED | KSANDOE |
| Note: 3/22/2024 - PREVIOUS INSPECTION NOTES 3/21/24: Not ready! 1). Numerous holes in CMU require wire lath. EX: Hose bibb, electrical wires, etc. 2). Missing stucco box for Ufer ground - both units. 3). Back lanai outlet box is not secured as required Unit A 4). Front entry outlet box is not installed (only hole in wall). Unit A 5). All windows need to be tape sealed around perimeter at a minimum. All windows are missing the FPA code stickers so installation requirements cannot be confirmed. 6). Need to install a silt fence per FBC-3307.1 3307.1 Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work. Protection shall be provided for footings, foundations, party walls, chimneys, skylights and roofs. Provisions shall be made to control water runopff and erosion during construction or demolition activities. The person making or causing an excavation to be made shall provide written notice to the owners of adjoining buildings advising them that the excavation is to be made and that the adjoing buildings should be protected. Said notification shall be delivered not less than 10 days prior to the scheduled starting date of the excavation. 3/15/2024 - PREVIOUS INSPECTION NOTES Wall sheathing has not been approved yet | |||
| ALL ROUGH | 04/01/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1. All metaliuc boxes are required to be bonded 2. Garage door to home missing 3. Windows missing anchors check all 4. E-cals dont match what is installed reviasion or correction required 5. CMU insulation is only rated for R3.2, cals require R4.1 Stopped inspection, not ready compleet re-inspection required | |||
| ALL ROUGH | 03/28/2024 | CANCELLED BY APPLICANT | WEB |
| LATH/BRICK/ WATER BARRIER | 03/22/2024 | Disapproved -FEE REQUIRED | RSIMS |
| Note: 3/21/24: Not ready! 1). Numerous holes in CMU require wire lath. EX: Hose bibb, electrical wires, etc. 2). Missing stucco box for Ufer ground - both units. 3). Back lanai outlet box is not secured as required Unit A 4). Front entry outlet box is not installed (only hole in wall). Unit A 5). All windows need to be tape sealed around perimeter at a minimum. All windows are missing the FPA code stickers so installation requirements cannot be confirmed. 6). Need to install a silt fence per FBC-3307.1 3307.1 Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work. Protection shall be provided for footings, foundations, party walls, chimneys, skylights and roofs. Provisions shall be made to control water runopff and erosion during construction or demolition activities. The person making or causing an excavation to be made shall provide written notice to the owners of adjoining buildings advising them that the excavation is to be made and that the adjoing buildings should be protected. Said notification shall be delivered not less than 10 days prior to the scheduled starting date of the excavation. 3/15/2024 - PREVIOUS INSPECTION NOTES Wall sheathing has not been approved yet | |||
| FIREWALL DRYWALL NAILING | 03/22/2024 | PARTIALLY APPROVED | RSIMS |
| Note: 3/21/24: This is a partial approval for the draft stop wall in the attic space above the ceiling since the entire ceiling will be covered with 5/8" type X as required on the plans. The second part of the inspection will be for that fire rated drywall. | |||
| WALL SHEATHING | 03/20/2024 | APPROVED | MKRASKI |
| WALL SHEATHING | 03/15/2024 | Disapproved - NO FEE | MKRASKI |
| Note: Wall sheathing has been covered with lath and moisture barrier, remove to check nailing pattern | |||
| LATH/BRICK/ WATER BARRIER | 03/15/2024 | Disapproved - NO FEE | MKRASKI |
| Note: Wall sheathing has not been approved yet | |||
| ROOF VALLEY & METAL | 02/02/2024 | APPROVED | KSANDOE |
| Note: Inspector Notes from Inspection 2460 Interior framing not complete. 1/29/2024 - PREVIOUS INSPECTION NOTES 1/29/24 Previous items not addressed 1/23/2024 - PREVIOUS INSPECTION NOTES Multiple truss's missing straps, stopped inspection, Check that every truss is strapped at bearing points Also trash needs to be cleanup before re-inspection is called | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 02/01/2024 | APPROVED - AS NOTED | KSANDOE |
| Note: Interior framing not complete. 1/29/2024 - PREVIOUS INSPECTION NOTES 1/29/24 Previous items not addressed 1/23/2024 - PREVIOUS INSPECTION NOTES Multiple truss's missing straps, stopped inspection, Check that every truss is strapped at bearing points Also trash needs to be cleanup before re-inspection is called | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/29/2024 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 1/29/24 Previous items not addressed 1/23/2024 - PREVIOUS INSPECTION NOTES Multiple truss's missing straps, stopped inspection, Check that every truss is strapped at bearing points Also trash needs to be cleanup before re-inspection is called | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/23/2024 | Disapproved - NO FEE | MKRASKI |
| Note: Multiple truss's missing straps, stopped inspection, Check that every truss is strapped at bearing points Also trash needs to be cleanup before re-inspection is called | |||
| FOUND SURVEY APPROVED (OFFICE) | 01/22/2024 | APPROVED | TBAKER |
| TIE BEAM / LINTEL | 12/27/2023 | APPROVED | RSIMS |
| MONOLITHIC SLAB | 12/06/2023 | APPROVED | MKRASKI |
| MONOLITHIC SLAB | 12/04/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. No compaction test paperwork on site 2. No 50 lbs of pressure on water lines 3. Failed 5' head pressure test 4. Back fill footing walls up to form boards or add board Stopped inspection, not read | |||
| PLUMBING 1ST ROUGH UNDERGROUND | 11/09/2023 | APPROVED | MKRASKI |
| WATER METER INSTALLATION REQUEST | 11/08/2023 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| MECH | COMPLETE | 10/04/2024 | 10/07/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 01/22/2024 | 01/22/2024 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 01/22/2024 | 01/22/2024 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 09/11/2023 | 09/12/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 08/31/2023 | 09/07/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| CUSVC | COMPLETE | 08/31/2023 | 09/06/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 08/31/2023 | 09/05/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 08/31/2023 | 08/31/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 08/31/2023 | 09/05/2023 |
| LOCATE | COMPLETE | 08/31/2023 | 09/05/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 08/31/2023 | 09/05/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 08/31/2023 | 09/07/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/31/2023 | 09/01/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 08/31/2023 | 10/20/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 08/31/2023 | 09/05/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM This is the correct review. Previous was done in error. Revise subcontractor or provide duct layout signed by listed subcontractor |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| CONTRACTOR CHANGE | ¤20.00 | 01/03/2025 |
| PLAN REVIEW - REVISION | ¤32.50 | 01/03/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/03/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/03/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/03/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/03/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/03/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/03/2025 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 01/03/2025 |
| SW ENG REINSPECTION 20 | ¤20.00 | 01/03/2025 |
| SW ENG REINSPECTION 20 | ¤20.00 | 01/03/2025 |
| SW ENG REINSPECTION 20 | ¤20.00 | 01/03/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 01/03/2025 |
| SW ENG REINSPECTION 30 | ¤30.00 | 01/03/2025 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/18/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/18/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 09/18/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 09/18/2023 |
| SEWER CREDIT | (¤850.00) | 09/18/2023 |
| SEWER INSPECTION | ¤25.00 | 09/18/2023 |
| SEWER CAPITAL FACILITY | ¤10,689.64 | 09/18/2023 |
| WATER CAPITAL FACILITY FEE | ¤7,847.76 | 09/18/2023 |
| SITE PLAN 30 | ¤30.00 | 09/18/2023 |
| CONNECTION FEES | ¤2,332.52 | 09/18/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 09/18/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 09/18/2023 |
| FC IMPACT FEE EMS | ¤124.00 | 09/18/2023 |
| IMPACT FEE FIRE | ¤420.52 | 09/18/2023 |
| IMPACT FEE FIRE | ¤841.04 | 09/18/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤436.00 | 09/18/2023 |
| FC IMPACT FEE LIBRARY | ¤536.00 | 09/18/2023 |
| IMPACT FEE PARKS | ¤3,538.30 | 09/18/2023 |
| IMPACT FEE SCHOOL | ¤10,900.00 | 09/18/2023 |
| IMPACT FEE TRANSPORTATION | ¤2,812.00 | 09/18/2023 |
| WATER -IRRIGATION INSPECTION | ¤50.00 | 09/18/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 09/18/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 09/18/2023 |
| SURCHARGE FS 533.721 | ¤7.21 | 09/18/2023 |
| SURCHARGE - FS 468.631 | ¤10.82 | 09/18/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/18/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 09/18/2023 |
| SW ENG PRE APRON | ¤30.00 | 09/18/2023 |
| WATER- TURN ON | ¤50.00 | 09/18/2023 |
| ADJUSTMENT 50% | (¤721.00) | 09/18/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/18/2023 |
| INSPECTION - RESIDENTIAL | ¤1,100.00 | 09/18/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤312.00 | 09/18/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤41,324.31 |