Permit #2023081588

Permit Details

Status: COED

Parcel Id: 07-11-31-7021-00040-0250
CONDITIONED SPACE: 2956 sqft
GARAGE: 888 sqft
OPENED PORCH (WITH ROOF) : 270 sqft
Total Square Footage: 4114 sqft
Block: 00040
Subdivision: 2186 - SECTION 21-WYNNFIELD
Job Phone: 386-237-5837
Location Address: 104 WELLWOOD LN
Type: DU - DUPLEX
Issue Date: 09/18/2023
NOC: RECORDED
Applicant name: MARSEL GILMANSHIN
Owner: LOURI SINKEVITCH AND TATYANA SEMENAVA

Address

412 OCEAN VIEW AVE 5C

BROOKLYN, NY 11235

Lot: 0250
Contracted Stated Job Value: ¤400,000.00
Job Description: duplex
Type: CN

Contractor

GILMANS DEVELOPMENT CORP
Status Location Address State License Number Phone
ACTIVE

4873 PALM COAST PARKWAY NW #4

PALM COAST, FL 32137

CBC1263180 (Exp: 08/31/2026) 386-237-5837

Sub Contractors

MAXIM BUDNIK
Status Location Address State License Number Phone
ACTIVE

9788 HALSEY RD

JACKSONVILLE, FL 32246

EC13007415 (Exp: 08/31/2026) 904-509-7306
MAXIM BUDNIK
Status Location Address State License Number
ACTIVE

3 WAVECREST PL

PALM COAST, FL 32164

CAC1818445 (Exp: 08/31/2026)
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 10/14/2024 FINAL APPROVED MKRASKI
Note:
BLD - BUILDING FINAL 09/30/2024 Disapproved - NO FEE MKRASKI
Note: 9/30/24 1. E-cals do not match equipment installed, revision required and must be approved by Building Dept. FBC [A] 107.4 2. Microwaves require breker lock (built ins) NEC 422.16 3. Kitchen outlets not GFCI protected (B-side) NEC 210.8 4. Back flow preventer missing on hose bib (B-side) FBCR P2903.8.5 5. Loose outlet in front bedroom NEC 406.4
U-CROSS CONNECTION 09/30/2024 APPROVED - AS NOTED LFITZGERALD
Note: *** NOTES ADDED BY LFITZGERALD 9/30/2024 11:17:33 AM *** no irr-no cross connection
ROW - FINAL INSPECTION 09/24/2024 APPROVED TPOLACEK
Note: 09/24/24 TPOLACEK** CORRECTIONS HAVE BEEN MADE, AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 9/20/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO REMOVE ALL MULCH FROM THE VACANT LOTS AND PUT SEED AND STRAW ON ALL BARE AREAS. 2) NEED TO REMOVE ALL TRASH AND CONSTRCTION DEBRIS FROM VACANT LOTS. -------------------------------------------------------------------------- 9/17/2024 - PREVIOUS INSPECTION NOTES 09/17/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 09/10/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. APPROVING FIELD INSPECTION AS NOTED.
ROW - FINAL INSPECTION 09/20/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO REMOVE ALL MULCH FROM THE VACANT LOTS AND PUT SEED AND STRAW ON ALL BARE AREAS. 2) NEED TO REMOVE ALL TRASH AND CONSTRCTION DEBRIS FROM VACANT LOTS. -------------------------------------------------------------------------- 9/17/2024 - PREVIOUS INSPECTION NOTES 09/17/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 09/10/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. APPROVING FIELD INSPECTION AS NOTED.
BLD - BUILDING FINAL 09/20/2024 CANCELLED BY APPLICANT MKRASKI
ROW - FINAL APRON (AFTER POUR) 09/20/2024 APPROVED PFLANAGAN
Note: CORRECTIONS MADE ------------------------------------------------------------------------ 9/17/2024 - PREVIOUS INSPECTION NOTES 09/17/24 TPOLACEK** YOU MUST CLEAN OUT DIRT AND SEDIMENT FROM CULVERT
ROW - FINAL APRON (AFTER POUR) 09/17/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 09/17/24 TPOLACEK** YOU MUST CLEAN OUT DIRT AND SEDIMENT FROM CULVERT
U -UTILITY RESIDENTIAL FINAL 09/17/2024 FINAL APPROVED LFITZGERALD
ROW - FINAL INSPECTION 09/17/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 09/17/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 09/10/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. APPROVING FIELD INSPECTION AS NOTED.
ROW FIELD SURVEY /GRADING CERTIFICATION 09/10/2024 APPROVED TPOLACEK
Note: 09/10/24 TPOLACEK*** BEFORE FINAL ROW INSPECTION YOU MUST HAVE SEED AND STRAW ON ALL BARE EARTH IN VACANT LOTS ON BOTH SIDES. YOU MUST REMOVE ALL DEBRIS AND CONCRETE FROM SWALE AND VACANT LOTS AS WELL AS ALL TRASH. ALL DISTURBED BARE GROUND IN SWALE NEEDS TO HAVE SOD. APPROVING FIELD INSPECTION AS NOTED. UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. 7/23/2024 - PREVIOUS INSPECTION NOTES 07/23/24 TPOLACEK*** YOU MUST FIRST SUBMIT AND A FINAL SURVEY AND THE FINAL SURVEY MUST BE APPROVED (IN OFFICE) BEFORE REQUESTING A FIELD SURVEY.
ROW- FINAL SURVEY/GRADING CERTIFICATION 09/10/2024 APPROVED TPOLACEK
FIREWALL FINAL 09/03/2024 APPROVED MKRASKI
Note: New inspection due to canceled inspection Inspector Notes from Inspection 2443 5/2/24 Draft stop approved and Ceiling and party wall all hung with 5/8'' type X board approved 3/22/2024 - PREVIOUS INSPECTION NOTES 3/21/24: This is a partial approval for the draft stop wall in the attic space above the ceiling since the entire ceiling will be covered with 5/8" type X as required on the plans. The second part of the inspection will be for that fire rated drywall.
ELECTRIC - EARLY POWER 08/20/2024 APPROVED - AS NOTED MKRASKI
Note: Emailed FPL @ 9:30am
ELECTRIC - EARLY POWER 08/19/2024 Disapproved -FEE REQUIRED KSANDOE
Note: R319.1 Missing Address Rear porch, left unit, outlet not safed off
WINDOW NAILING 07/23/2024 APPROVED MKRASKI
ROW FIELD SURVEY /GRADING CERTIFICATION 07/23/2024 Disapproved - NO FEE TPOLACEK
Note: 07/23/24 TPOLACEK*** YOU MUST FIRST SUBMIT AND A FINAL SURVEY AND THE FINAL SURVEY MUST BE APPROVED (IN OFFICE) BEFORE REQUESTING A FIELD SURVEY.
ROW- PRE-APRON (PRE-POUR) 06/05/2024 APPROVED PFLANAGAN
Note: CORRECTIONS MADE IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders and the homowners responsibility to ensure that nothing changes after this Inspection is approved. It will not be on the city if any changes after this inspection. --------------------------------------------------------------------------------------- 5/31/2024 - PREVIOUS INSPECTION NOTES 05/31/24 TPOLACEK*** BOTH CULVERT PIPES ARE BACKPITCHED BY OVER .03, RIGHT SIDE CULVERT IS .10 OVER THE TOLERNACE ALLOWED, RIGHT SIDE PIPE IS NOT 8' FROM EDGE OF EXISTING ROADWAY. PLEASE MAKE CORRECTIONS BEFORE REQUESTING ANOTHER INSPECTION. 5/30/2024 - PREVIOUS INSPECTION NOTES 05/30/24 TPOLACEK*** MET WITH MARSEL AND EXPLAINED WHAT HE NEEDS TO DO TO PASS INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/20/2024 - PREVIOUS INSPECTION NOTES 05/20/24 TPOLACEK*** NOT READY FOR INSPECTION, I SHOT THE PIPE ON THE LEFT AND IT WAS .20 OUT OF TOLERNACE I DID NOT SHOOT PIPE ON THE RIGHT AS SITE IS NOT READY. FORM BOARDS ARE NOT SET TO CULVERT DIAGRAM, PIPE IS NOT BURIED 1/2 WAYAND BASE IS NOT GRADED LEVEL. PLEASE SEE ATTACHED PHOTOS
ROW- PRE-APRON (PRE-POUR) 06/03/2024 CANCELLED BY APPLICANT WEB
Note: 5/31/2024 - PREVIOUS INSPECTION NOTES 05/31/24 TPOLACEK*** BOTH CULVERT PIPES ARE BACKPITCHED BY OVER .03, RIGHT SIDE CULVERT IS .10 OVER THE TOLERNACE ALLOWED, RIGHT SIDE PIPE IS NOT 8' FROM EDGE OF EXISTING ROADWAY. PLEASE MAKE CORRECTIONS BEFORE REQUESTING ANOTHER INSPECTION. 5/30/2024 - PREVIOUS INSPECTION NOTES 05/30/24 TPOLACEK*** MET WITH MARSEL AND EXPLAINED WHAT HE NEEDS TO DO TO PASS INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/20/2024 - PREVIOUS INSPECTION NOTES 05/20/24 TPOLACEK*** NOT READY FOR INSPECTION, I SHOT THE PIPE ON THE LEFT AND IT WAS .20 OUT OF TOLERNACE I DID NOT SHOOT PIPE ON THE RIGHT AS SITE IS NOT READY. FORM BOARDS ARE NOT SET TO CULVERT DIAGRAM, PIPE IS NOT BURIED 1/2 WAYAND BASE IS NOT GRADED LEVEL. PLEASE SEE ATTACHED PHOTOS
ROW- PRE-APRON (PRE-POUR) 05/31/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 05/31/24 TPOLACEK*** BOTH CULVERT PIPES ARE BACKPITCHED BY OVER .03, RIGHT SIDE CULVERT IS .10 OVER THE TOLERNACE ALLOWED, RIGHT SIDE PIPE IS NOT 8' FROM EDGE OF EXISTING ROADWAY. PLEASE MAKE CORRECTIONS BEFORE REQUESTING ANOTHER INSPECTION. 5/30/2024 - PREVIOUS INSPECTION NOTES 05/30/24 TPOLACEK*** MET WITH MARSEL AND EXPLAINED WHAT HE NEEDS TO DO TO PASS INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/20/2024 - PREVIOUS INSPECTION NOTES 05/20/24 TPOLACEK*** NOT READY FOR INSPECTION, I SHOT THE PIPE ON THE LEFT AND IT WAS .20 OUT OF TOLERNACE I DID NOT SHOOT PIPE ON THE RIGHT AS SITE IS NOT READY. FORM BOARDS ARE NOT SET TO CULVERT DIAGRAM, PIPE IS NOT BURIED 1/2 WAYAND BASE IS NOT GRADED LEVEL. PLEASE SEE ATTACHED PHOTOS
ROW- PRE-APRON (PRE-POUR) 05/30/2024 Disapproved - NO FEE TPOLACEK
Note: 05/30/24 TPOLACEK*** MET WITH MARSEL AND EXPLAINED WHAT HE NEEDS TO DO TO PASS INSPECTION. ++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 5/20/2024 - PREVIOUS INSPECTION NOTES 05/20/24 TPOLACEK*** NOT READY FOR INSPECTION, I SHOT THE PIPE ON THE LEFT AND IT WAS .20 OUT OF TOLERNACE I DID NOT SHOOT PIPE ON THE RIGHT AS SITE IS NOT READY. FORM BOARDS ARE NOT SET TO CULVERT DIAGRAM, PIPE IS NOT BURIED 1/2 WAYAND BASE IS NOT GRADED LEVEL. PLEASE SEE ATTACHED PHOTOS
ROW- PRE-APRON (PRE-POUR) 05/20/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 05/20/24 TPOLACEK*** NOT READY FOR INSPECTION, I SHOT THE PIPE ON THE LEFT AND IT WAS .20 OUT OF TOLERNACE I DID NOT SHOOT PIPE ON THE RIGHT AS SITE IS NOT READY. FORM BOARDS ARE NOT SET TO CULVERT DIAGRAM, PIPE IS NOT BURIED 1/2 WAYAND BASE IS NOT GRADED LEVEL. PLEASE SEE ATTACHED PHOTOS
FIREWALL FINAL 05/15/2024 CANCELLED BY APPLICANT WEB
Note: Inspector Notes from Inspection 2443 5/2/24 Draft stop approved and Ceiling and party wall all hung with 5/8'' type X board approved 3/22/2024 - PREVIOUS INSPECTION NOTES 3/21/24: This is a partial approval for the draft stop wall in the attic space above the ceiling since the entire ceiling will be covered with 5/8" type X as required on the plans. The second part of the inspection will be for that fire rated drywall.
U - SEWER TIE IN 05/10/2024 APPROVED - AS NOTED MGIBSON
Note: 5/9/2024 - PREVIOUS INSPECTION NOTES TAP NOT MADE. THIS WAS A VIRTUAL INSPECTION
U - SEWER TIE IN 05/09/2024 Disapproved - NO FEE MGIBSON
Note: TAP NOT MADE
GRAVITY SEWER TEST 05/08/2024 APPROVED - AS NOTED MGIBSON
Note: GRAVITY SEWER IS APPROVED TAP NOT MADE. WHEN SEWER TIE IN IS MADE SCHEDUALE FOR THIS INSPECTION ONLY
FIREWALL DRYWALL NAILING 05/02/2024 APPROVED - AS NOTED MKRASKI
Note: 5/2/24 Draft stop approved and Ceiling and party wall all hung with 5/8'' type X board approved 3/22/2024 - PREVIOUS INSPECTION NOTES 3/21/24: This is a partial approval for the draft stop wall in the attic space above the ceiling since the entire ceiling will be covered with 5/8" type X as required on the plans. The second part of the inspection will be for that fire rated drywall.
FIREWALL FINAL 04/30/2024 PARTIALLY APPROVED MKRASKI
Note: 4/30/24 1. Check draft stop extends tp top of soffit (leave soffit off untill after fire wall final is called back in 2. Draft stop in attic ok, call back in once ceiling and party wall are hung 4/25/2024 - PREVIOUS INSPECTION NOTES 4/25/24 Draft stop must extend down to top of soffit 4/24/2024 - PREVIOUS INSPECTION NOTES Plans call for firewall to be 5/8'' X-type on the ceiling, only draft stop has been installed **** all penitrations and opening need to be sealed in draft stop
FIREWALL FINAL 04/25/2024 Disapproved - NO FEE MKRASKI
Note: 4/25/24 Draft stop must extend down to top of soffit 4/24/2024 - PREVIOUS INSPECTION NOTES Plans call for firewall to be 5/8'' X-type on the ceiling, only draft stop has been installed **** all penitrations and opening need to be sealed in draft stop
FIREWALL FINAL 04/24/2024 Disapproved -FEE REQUIRED MKRASKI
Note: Plans call for firewall to be 5/8'' X-type on the ceiling, only draft stop has been installed **** all penitrations and opening need to be sealed in draft stop
INSULATION 04/17/2024 APPROVED JSTEWART
Note: 4/16/2024 - PREVIOUS INSPECTION NOTES 1. Insulation board missing on A side near front door 2. Horizonal romex runs in kitchen wall needs draft stop, Both sides
INSULATION 04/16/2024 Disapproved - NO FEE MKRASKI
Note: 1. Insulation board missing on A side near front door 2. Horizonal romex runs in kitchen wall needs draft stop, Both sides
ALL ROUGH 04/11/2024 APPROVED - AS NOTED MKRASKI
Note: 4/11/24 1. Garage door bucks required to have one more anchor above opening in both units 2. SGD opening needs to be sealed (door on back order) Added window nailing inspection 4/9/2024 - PREVIOUS INSPECTION NOTES 4/9/24 Make ALL repairs and have detail uploaded from previous and approved throigh Building Dept. before calling in re-inspection. 4/5/2024 - PREVIOUS INSPECTION NOTES Need to see detail for roof sheathing inre fireboard penetration. Missing garage door bucking Missing garage dwelling entry door Missing rear slider Window anchors must be countersunk 4/1/2024 - PREVIOUS INSPECTION NOTES 1. All metaliuc boxes are required to be bonded 2. Garage door to home missing 3. Windows missing anchors check all 4. E-cals dont match what is installed reviasion or correction required 5. CMU insulation is only rated for R3.2, cals require R4.1 Stopped inspection, not ready compleet re-inspection required
ALL ROUGH 04/09/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 4/9/24 Make ALL repairs and have detail uploaded from previous and approved throigh Building Dept. before calling in re-inspection. 4/5/2024 - PREVIOUS INSPECTION NOTES Need to see detail for roof sheathing inre fireboard penetration. Missing garage door bucking Missing garage dwelling entry door Missing rear slider Window anchors must be countersunk 4/1/2024 - PREVIOUS INSPECTION NOTES 1. All metaliuc boxes are required to be bonded 2. Garage door to home missing 3. Windows missing anchors check all 4. E-cals dont match what is installed reviasion or correction required 5. CMU insulation is only rated for R3.2, cals require R4.1 Stopped inspection, not ready compleet re-inspection required
ALL ROUGH 04/05/2024 Disapproved -FEE REQUIRED KSANDOE
Note: Need to see detail for roof sheathing inre fireboard penetration. Missing garage door bucking Missing garage dwelling entry door Missing rear slider Window anchors must be countersunk 4/1/2024 - PREVIOUS INSPECTION NOTES 1. All metaliuc boxes are required to be bonded 2. Garage door to home missing 3. Windows missing anchors check all 4. E-cals dont match what is installed reviasion or correction required 5. CMU insulation is only rated for R3.2, cals require R4.1 Stopped inspection, not ready compleet re-inspection required
LATH/BRICK/ WATER BARRIER 04/05/2024 APPROVED KSANDOE
Note: 3/22/2024 - PREVIOUS INSPECTION NOTES 3/21/24: Not ready! 1). Numerous holes in CMU require wire lath. EX: Hose bibb, electrical wires, etc. 2). Missing stucco box for Ufer ground - both units. 3). Back lanai outlet box is not secured as required Unit A 4). Front entry outlet box is not installed (only hole in wall). Unit A 5). All windows need to be tape sealed around perimeter at a minimum. All windows are missing the FPA code stickers so installation requirements cannot be confirmed. 6). Need to install a silt fence per FBC-3307.1 3307.1 Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work. Protection shall be provided for footings, foundations, party walls, chimneys, skylights and roofs. Provisions shall be made to control water runopff and erosion during construction or demolition activities. The person making or causing an excavation to be made shall provide written notice to the owners of adjoining buildings advising them that the excavation is to be made and that the adjoing buildings should be protected. Said notification shall be delivered not less than 10 days prior to the scheduled starting date of the excavation. 3/15/2024 - PREVIOUS INSPECTION NOTES Wall sheathing has not been approved yet
ALL ROUGH 04/01/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 1. All metaliuc boxes are required to be bonded 2. Garage door to home missing 3. Windows missing anchors check all 4. E-cals dont match what is installed reviasion or correction required 5. CMU insulation is only rated for R3.2, cals require R4.1 Stopped inspection, not ready compleet re-inspection required
ALL ROUGH 03/28/2024 CANCELLED BY APPLICANT WEB
LATH/BRICK/ WATER BARRIER 03/22/2024 Disapproved -FEE REQUIRED RSIMS
Note: 3/21/24: Not ready! 1). Numerous holes in CMU require wire lath. EX: Hose bibb, electrical wires, etc. 2). Missing stucco box for Ufer ground - both units. 3). Back lanai outlet box is not secured as required Unit A 4). Front entry outlet box is not installed (only hole in wall). Unit A 5). All windows need to be tape sealed around perimeter at a minimum. All windows are missing the FPA code stickers so installation requirements cannot be confirmed. 6). Need to install a silt fence per FBC-3307.1 3307.1 Protection required. Adjoining public and private property shall be protected from damage during construction, remodeling and demolition work. Protection shall be provided for footings, foundations, party walls, chimneys, skylights and roofs. Provisions shall be made to control water runopff and erosion during construction or demolition activities. The person making or causing an excavation to be made shall provide written notice to the owners of adjoining buildings advising them that the excavation is to be made and that the adjoing buildings should be protected. Said notification shall be delivered not less than 10 days prior to the scheduled starting date of the excavation. 3/15/2024 - PREVIOUS INSPECTION NOTES Wall sheathing has not been approved yet
FIREWALL DRYWALL NAILING 03/22/2024 PARTIALLY APPROVED RSIMS
Note: 3/21/24: This is a partial approval for the draft stop wall in the attic space above the ceiling since the entire ceiling will be covered with 5/8" type X as required on the plans. The second part of the inspection will be for that fire rated drywall.
WALL SHEATHING 03/20/2024 APPROVED MKRASKI
WALL SHEATHING 03/15/2024 Disapproved - NO FEE MKRASKI
Note: Wall sheathing has been covered with lath and moisture barrier, remove to check nailing pattern
LATH/BRICK/ WATER BARRIER 03/15/2024 Disapproved - NO FEE MKRASKI
Note: Wall sheathing has not been approved yet
ROOF VALLEY & METAL 02/02/2024 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2460 Interior framing not complete. 1/29/2024 - PREVIOUS INSPECTION NOTES 1/29/24 Previous items not addressed 1/23/2024 - PREVIOUS INSPECTION NOTES Multiple truss's missing straps, stopped inspection, Check that every truss is strapped at bearing points Also trash needs to be cleanup before re-inspection is called
ROOF SHEATHING / BRACES/TIES/DOWN CELL 02/01/2024 APPROVED - AS NOTED KSANDOE
Note: Interior framing not complete. 1/29/2024 - PREVIOUS INSPECTION NOTES 1/29/24 Previous items not addressed 1/23/2024 - PREVIOUS INSPECTION NOTES Multiple truss's missing straps, stopped inspection, Check that every truss is strapped at bearing points Also trash needs to be cleanup before re-inspection is called
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/29/2024 Disapproved -FEE REQUIRED MKRASKI
Note: 1/29/24 Previous items not addressed 1/23/2024 - PREVIOUS INSPECTION NOTES Multiple truss's missing straps, stopped inspection, Check that every truss is strapped at bearing points Also trash needs to be cleanup before re-inspection is called
ROOF SHEATHING / BRACES/TIES/DOWN CELL 01/23/2024 Disapproved - NO FEE MKRASKI
Note: Multiple truss's missing straps, stopped inspection, Check that every truss is strapped at bearing points Also trash needs to be cleanup before re-inspection is called
FOUND SURVEY APPROVED (OFFICE) 01/22/2024 APPROVED TBAKER
TIE BEAM / LINTEL 12/27/2023 APPROVED RSIMS
MONOLITHIC SLAB 12/06/2023 APPROVED MKRASKI
MONOLITHIC SLAB 12/04/2023 Disapproved - NO FEE MKRASKI
Note: 1. No compaction test paperwork on site 2. No 50 lbs of pressure on water lines 3. Failed 5' head pressure test 4. Back fill footing walls up to form boards or add board Stopped inspection, not read
PLUMBING 1ST ROUGH UNDERGROUND 11/09/2023 APPROVED MKRASKI
WATER METER INSTALLATION REQUEST 11/08/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 10/04/2024 10/07/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ENGIN1 COMPLETE 01/22/2024 01/22/2024
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 01/22/2024 01/22/2024
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
MECH COMPLETE 09/11/2023 09/12/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD COMPLETE 08/31/2023 09/07/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
CUSVC COMPLETE 08/31/2023 09/06/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 08/31/2023 09/05/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 08/31/2023 08/31/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 08/31/2023 09/05/2023
LOCATE COMPLETE 08/31/2023 09/05/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 08/31/2023 09/05/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 08/31/2023 09/07/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 08/31/2023 09/01/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 08/31/2023 10/20/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
MECH HOLD 08/31/2023 09/05/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM This is the correct review. Previous was done in error. Revise subcontractor or provide duct layout signed by listed subcontractor

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 01/03/2025
PLAN REVIEW - REVISION ¤32.50 01/03/2025
REINSPECTION RESIDENTIAL ¤40.00 01/03/2025
REINSPECTION RESIDENTIAL ¤40.00 01/03/2025
REINSPECTION RESIDENTIAL ¤40.00 01/03/2025
REINSPECTION RESIDENTIAL ¤40.00 01/03/2025
REINSPECTION RESIDENTIAL ¤40.00 01/03/2025
REINSPECTION RESIDENTIAL ¤40.00 01/03/2025
REINSPECTION RESIDENTIAL ¤40.00 01/03/2025
SW ENG REINSPECTION 20 ¤20.00 01/03/2025
SW ENG REINSPECTION 20 ¤20.00 01/03/2025
SW ENG REINSPECTION 20 ¤20.00 01/03/2025
SW ENG REINSPECTION 30 ¤30.00 01/03/2025
SW ENG REINSPECTION 30 ¤30.00 01/03/2025
SW ENG - REVIEW 20 ¤20.00 09/18/2023
SW ENG RES REVIEW 200 ¤200.00 09/18/2023
TRANS IMPACT FEE ADMIN ¤54.36 09/18/2023
TRANS IMPACT FEE ADMIN (¤54.36) 09/18/2023
SEWER CREDIT (¤850.00) 09/18/2023
SEWER INSPECTION ¤25.00 09/18/2023
SEWER CAPITAL FACILITY ¤10,689.64 09/18/2023
WATER CAPITAL FACILITY FEE ¤7,847.76 09/18/2023
SITE PLAN 30 ¤30.00 09/18/2023
CONNECTION FEES ¤2,332.52 09/18/2023
FIRE IMPACT FEE ADMIN ¤12.62 09/18/2023
FIRE IMPACT FEE ADMIN (¤12.62) 09/18/2023
FC IMPACT FEE EMS ¤124.00 09/18/2023
IMPACT FEE FIRE ¤420.52 09/18/2023
IMPACT FEE FIRE ¤841.04 09/18/2023
FC IMPACT FEE LAW ENFORCEMENT ¤436.00 09/18/2023
FC IMPACT FEE LIBRARY ¤536.00 09/18/2023
IMPACT FEE PARKS ¤3,538.30 09/18/2023
IMPACT FEE SCHOOL ¤10,900.00 09/18/2023
IMPACT FEE TRANSPORTATION ¤2,812.00 09/18/2023
WATER -IRRIGATION INSPECTION ¤50.00 09/18/2023
PARKS IMPACT FEE ADMIN ¤53.07 09/18/2023
PARKS IMPACT FEE ADMIN (¤53.07) 09/18/2023
SURCHARGE FS 533.721 ¤7.21 09/18/2023
SURCHARGE - FS 468.631 ¤10.82 09/18/2023
SW ENG - FOUNDATION SURVEY ¤20.00 09/18/2023
SW ENG INSPECTION 80 ¤80.00 09/18/2023
SW ENG PRE APRON ¤30.00 09/18/2023
WATER- TURN ON ¤50.00 09/18/2023
ADJUSTMENT 50% (¤721.00) 09/18/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/18/2023
INSPECTION - RESIDENTIAL ¤1,100.00 09/18/2023
PLAN REVIEW - RESIDENTIAL ¤312.00 09/18/2023
Fees Total Due: ¤0.00 Total Paid: ¤41,324.31