I want to search for...
Permit #2023090029
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7034-01120-0010 |
| Block: 01120 |
| Subdivision: - |
| Job Phone: (386)586-5569 |
| Location Address: 1 EDGEWATER DR |
| Type: PO - POOL |
| Issue Date: 09/05/2023 |
| NOC: RECORDED |
| Applicant name: BRIAN ROBERT LENOIS |
| Owner: 43 ERIC DRIVE LLC |
|
Address 1 EDGEWATER DR PALM COAST, FL 32164 |
| Lot: 0010 |
| Contracted Stated Job Value: ¤43,241.00 |
| Job Description: POOL WITH SCREEN |
| Type: CN |
| Original Permit #: 2021061267 |
Contractor
ARTESIAN POOLS OF EAST FLORIDA, INC.
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
762 S NOVA ROAD DAYTONA BEACH , FL 32114 |
CPC1456573 (Exp: 08/31/2026) | (386)586-5569 | (386)258-3702 |
Sub Contractors
JEFFREY ADAM MCGREGOR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1312 YORKTOWN STREET DELAND , FL 32724 |
EC13005662 (Exp: 08/31/2026) | 386-736-7475 | 386-785-1503 |
BRIAN THOMAS KULL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
18 STRAFORD PLACE PORT ORANGE, FL 32128 |
CGC1504924 (Exp: 08/31/2026) | 386-682-9554 | (386)258-8042 |
JEFFREY ADAM MCGREGOR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1312 YORKTOWN STREET DELAND , FL 32724 |
EC13005662 (Exp: 08/31/2026) | 386-736-7475 | 386-785-1503 |
BRIAN THOMAS KULL
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
18 STRAFORD PLACE PORT ORANGE, FL 32128 |
CGC1504924 (Exp: 08/31/2026) | 386-682-9554 | (386)258-8042 |
Inspection History
| Type | Request Date | Result | Inspector |
| POOL FINAL | 01/19/2024 | APPROVED | RSIMS |
| U -UTILITY RESIDENTIAL FINAL | 01/18/2024 | FINAL APPROVED | JHARDING |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 09/07/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. ----------------------------------------------------------------------------- 4/18/2023 - PREVIOUS INSPECTION NOTES THIS IS A BOUNDARY SURVEY, WE NEED A TOPOGRAPHIC SURVEYS. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 09/07/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW - FINAL INSPECTION | 09/07/2023 | APPROVED | PFLANAGAN |
| Note: At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 04/18/2023 | Disapproved - NO FEE | GBERTOLA |
| Note: THIS IS A BOUNDARY SURVEY, WE NEED A TOPOGRAPHIC SURVEYS. | |||
| ELECTRIC AND ALARM | 12/02/2022 | APPROVED | BTAYLOR |
| POOL DECK | 05/27/2022 | APPROVED | KSANDOE |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION 3 of the 4 point bonding wire connections were easily pulled up out of the groud., The ends were tied to a piece of # 3 rebar and buried to give the appearance that the wires were connected to the pool shell steel structure. Install the proper connections and leave unburied for reinspection. NEC 680.26 The pool piping needs to be under pressure test. R 4501.1.12.1 5/25/22 Water piping not under test. | |||
| POOL DECK | 05/25/2022 | Disapproved - NO FEE | JWALKER |
| Note: THIS IS A REINSPECTION 3 of the 4 point bonding wire connections were easily pulled up out of the groud., The ends were tied to a piece of # 3 rebar and buried to give the appearance that the wires were connected to the pool shell steel structure. Install the proper connections and leave unburied for reinspection. NEC 680.26 The pool piping needs to be under pressure test. R 4501.1.12.1 5/25/22 Water piping not under test. | |||
| POOL DECK | 05/19/2022 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 3 of the 4 point bonding wire connections were easily pulled up out of the ground., The ends were tied to a piece of # 3 rebar and buried to give the appearance that the wires were connected to the pool shell steel structure. Install the proper connections and leave unburied for reinspection. NEC 680.26 The pool piping needs to be under pressure test. R 4501.1.12.1 | |||
| STEEL AND GROUND | 12/15/2021 | Disapproved - NO FEE | JWALKER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Steel is not completed 4 point grounds not installed Plumbing not installed and pressurized. 12/2/21 Plumbing not install is not pressurized or not holding water. 12/15/21 Plumbing line is not pressurized I read contractors notes below not sure what you trying to explain. My number is 386-283-1296 I tried to call the numbers on the permit on is disconnected the other was a businees phone that does not answer till 8am Give me a call to explain what you are doing with the drains Thank you Jim. | |||
| STEEL AND GROUND | 12/15/2021 | APPROVED | JWALKER |
| Note: THIS IS A REINSPECTION THIS IS A REINSPECTION Steel is not completed 4 point grounds not installed Plumbing not installed and pressurized. 12/2/21 Plumbing not installed is not pressurized or not holding water. | |||
| STEEL AND GROUND | 12/02/2021 | Disapproved -FEE REQUIRED | JWALKER |
| Note: THIS IS A REINSPECTION Steel is not completed 4 point grounds not installed Plumbing not installed and pressurized. 12/2/21 Plumbing not installed is not pressurized or not holding water. | |||
| STEEL AND GROUND | 12/01/2021 | Disapproved - NO FEE | JWALKER |
| Note: Steel is not completed 4 point grounds not installed Plumbing not installed and pressurized. |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | HOLD | 12/02/2021 | 12/02/2021 |
| Note: Held By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM IF THIS IS A FINAL SURVEY PLEASE RENAME IT FINAL SURVEY NOT ASBUILT | |||
| BADMIN | COMPLETE | 12/02/2021 | 12/02/2021 |
| Note: Released By: MARGA DEFREITAS - - MDEFREITAS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 08/06/2021 | 08/09/2021 |
| Note: Released By: ESTELLE LENS - (386)986-3751 - | |||
| BLD | COMPLETE | 08/06/2021 | 08/09/2021 |
| Note: Released By: HAROLD ALLEN - - HALLEN@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 06/25/2021 | 06/25/2021 |
| Note: Released By: GABRIEL BERTOLA - (386)225-3840 - GBERTOLA@PALMCOASTGOV.COM | |||
| ZON | HOLD | 06/22/2021 | 06/22/2021 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Site plan must show all proposed improvements - to include any concrete door pads Site plan must show dimensions of proposed pool deck and all concrete door/pool equipment pads. | |||
| BLD | HOLD | 06/22/2021 | 06/29/2021 |
| Note: Held By: FRED REODICA - (386)986-4734 - FREODICA@PALMCOASTGOV.COM 1. Provide total pool volume calculation in gallons. 2. Engineered pool plan - page 2 of 5 - delete Chapter 42 and maintain Chapter 45 of 2020 FBC - Residential (7th Edition) due to Code Changes. . 3. City's standard requirements for pool plan (not engineered): Pool contractor on pool plan sheets or similar (usually submitted along with a site plan and hand drawn or CAD drawn): • If pool cage is attached to house, show windows and / or doors in wall that adjoins pool cage. • If screened porch / lanai is between back of house and pool cage show it as well and if there is an existing exterior door from the lanai show it as well as the door swing. • If pool cage is not attached to the house and / or house wall is not acting as barrier wall then probably no reason to show exterior wall of house. Whether pool cage is attached to house or not the pool cage should show: • Location of door(s). • Door swing (out from pool area). • Landings at doors (generally 36" x 36"). • Indicate presence of latching device and height (54" above threshold). • Indicate presence of self-closing device. Alarms • Indicate location and type of pool alarms. • If water alarm show it in the pool location and indicate a ASTM F2208 alarm will be provided. • If window / door alarm show it at each window / door and indicate a UL 2017 alarm will be provided. • Provide manufacturer spec sheets for alarm(s) types and spec sheets indicate either ASTM F2208 or UL2017. | |||
| ELEC | COMPLETE | 06/22/2021 | 06/23/2021 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 06/22/2021 | 06/23/2021 |
| Note: Released By: CHRIS PISCITELLI - (386)986-3782 - CPISCITELLI@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤95.00) | 09/05/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/05/2023 |
| INSPECTION- POOL | ¤160.00 | 09/05/2023 |
| SURCHARGE FS 533.721 | ¤2.00 | 09/05/2023 |
| SURCHARGE - FS 468.631 | ¤2.00 | 09/05/2023 |
| SW ENG INSPECTION 40 | ¤40.00 | 09/05/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤139.00 |