I want to search for...

Permit #2023090194

Permit Details

Status: COED

Parcel Id: 07-11-31-7035-00820-0030
CONDITIONED SPACE: 2295 sqft
GARAGE: 538 sqft
OPENED PORCH (WITH ROOF) : 201 sqft
OPENED PORCH (WITH ROOF) : 229 sqft
Total Square Footage: 3263 sqft
Block: 00820
Subdivision: 2172 - SECTION 35-BELLE TERRE
Job Phone: 912-258-2201
Location Address: 13 BUFFALO GROVE DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 10/20/2023
NOC: RECORDED
Applicant name: JAMES FUCETOLA III
Owner: PALM COAST COMMUNITIES LLC

Address

PO BOX 22547

ST SIMONS ISLAND, GA 31522

Lot: 0030
Contracted Stated Job Value: ¤215,000.00
Job Description: Single Family Residence
Type: CN

Contractor

PALM COAST COMMUNITIES LLC
Status Location Address State License Number Phone
INACTIVE

PO BOX 22547

PALM COAST, FL 32164

CBC1262878 (Exp: 08/31/2026) 321-501-4617

Sub Contractors

GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

48 EAGLE LAKES DRIVE

FLAGLER BEACH, FL 32136

CAC048127 (Exp: 08/31/2026) 386-597-3280
WILLIAM FRANK DUDLEY JR.
Status Location Address State License Number Phone
ACTIVE

P.O. BOX 978

Bunnell, FL 32110

EC0003177 (Exp: 08/31/2026) (386)437-3068
OLEG BELINSKIY
Status Location Address State License Number Phone
ACTIVE

19 PINE CIRCLE DRIVE19

PALM COAST, FL 32167

CCC1325974 (Exp: 08/31/2026) 386-263-7906
JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996

Inspection History

Type Request Date Result Inspector
ROW - FINAL APRON (AFTER POUR) 03/04/2024 APPROVED - AS NOTED FSLADISH
Note: 3/4/24 PIPE IS GOOD. CUTS MADE. CULVERT CLEAR. HOT PATCH COMPLETED AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved.
BLD - BUILDING FINAL 03/01/2024 FINAL APPROVED JSTEWART
Note: 2/29/2024 - PREVIOUS INSPECTION NOTES 2/29/24- 1. Master bath lav on left Fixture hot water is reversed. FPBC 607.4 Flow of hot water to fixtures. Fixture fittings, faucets and diverters shall be installed and adjusted so that the flow of hot water from the fittings corresponds to the left-hand side of the fixture fitting. 2. Master Shower mixing valve Hot water is oposite of fixture indication stamp. FPBC 607.4 Flow of hot water to fixtures.Shower and tub/shower mixing valves conforming to ASSE 1016/ASME A112.1016/CSA B125.16 or ASME A112.18.1/CSA B125.1, where the flow of hot water corresponds to the markings on the device. 3. Lanai bath Shower mixing valve Hot water is oposite of fixture indication stamp. FPBC 607.4 Flow of hot water to fixtures. 4. Please seal or cap dryer exhaust duct (unless dryer is installed) M1502.4.7 Exhaust duct required......Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates...
BLD - BUILDING FINAL 02/29/2024 Disapproved - NO FEE JSTEWART
Note: 2/29/24- 1. Master bath lav on left Fixture hot water is reversed. FPBC 607.4 Flow of hot water to fixtures. Fixture fittings, faucets and diverters shall be installed and adjusted so that the flow of hot water from the fittings corresponds to the left-hand side of the fixture fitting. 2. Master Shower mixing valve Hot water is oposite of fixture indication stamp. FPBC 607.4 Flow of hot water to fixtures.Shower and tub/shower mixing valves conforming to ASSE 1016/ASME A112.1016/CSA B125.16 or ASME A112.18.1/CSA B125.1, where the flow of hot water corresponds to the markings on the device. 3. Lanai bath Shower mixing valve Hot water is oposite of fixture indication stamp. FPBC 607.4 Flow of hot water to fixtures. 4. Please seal or cap dryer exhaust duct (unless dryer is installed) M1502.4.7 Exhaust duct required......Where the clothes dryer is not installed at the time of occupancy the exhaust duct shall be capped or plugged in the space in which it originates...
U-CROSS CONNECTION 02/29/2024 APPROVED DHANEY
ROW - STORMWATER FINAL 02/29/2024 APPROVED TPOLACEK
Note: 02/29/24 AT TIME OF INSPECTION THE HOT PATCH IS STILL NOT COMPLETE. I WILL APPROVE THE FINAL ROW BUT YOU NEED TO COMPLETE BEFORE THE AFTER POUR.
U -UTILITY RESIDENTIAL FINAL 02/29/2024 FINAL APPROVED DHANEY
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/28/2024 APPROVED TPOLACEK
Note: 02/28/27
ROW FIELD SURVEY /GRADING CERTIFICATION 02/28/2024 APPROVED TPOLACEK
Note: 02/28/24 UPON WALKING PROPERTY DRAINAGE WILL WORK AS INDICATED ON FINAL SURVEY. AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED.
ELECTRIC - EARLY POWER 01/30/2024 APPROVED - AS NOTED JSTEWART
Note: 1/30/24- Authorize release of email to FPL @ 1:18p 1/29/2024 - PREVIOUS INSPECTION NOTES 1/29/24-via text
ELECTRIC - EARLY POWER 01/29/2024 CANCELLED BY APPLICANT JSTEWART
Note: 1/29/24-via text
ROW- PRE-APRON (PRE-POUR) 01/29/2024 APPROVED PFLANAGAN
Note: IT'S YOUR RESPONSIBILITY TO CHECK THE CULVERT ELEVATIONS BEFORE POURING CONCRETE. ALL CONCRETE NEEDS TO BE A MINIMUM OF 3000PSI WITH FIBER OR WITH METAL MESH IN THE CONCRETE TO MEET ALL CITY'S STANDARDS. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. --------------------------------------------------------------------------------------- 1/26/2024 - PREVIOUS INSPECTION NOTES 01/26/24 JOB BOX MUST BE REMOVED FROM POLE. CANNOT GET TO THE BENCHMARK TO SHOOT THE ELEVATIONS. JOB BOXES ARE NOT ALLOWED TO MOUNTED TO ANY POLES FOR FUTURE REFERENCE.
ROW- PRE-APRON (PRE-POUR) 01/26/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 01/26/24 JOB BOX MUST BE REMOVED FROM POLE. CANNOT GET TO THE BENCHMARK TO SHOOT THE ELEVATIONS. JOB BOXES ARE NOT ALLOWED TO MOUNTED TO ANY POLES FOR FUTURE REFERENCE.
U - SEWER TIE IN 01/23/2024 APPROVED MGIBSON
GRAVITY SEWER TEST 01/23/2024 APPROVED MGIBSON
Note: 11/14/2023 - PREVIOUS INSPECTION NOTES 11/13/2023 - PREVIOUS INSPECTION NOTES sewer not ran yet
PEP TANK INSTALLATION REQUEST 12/28/2023 APPROVED TCHURCHILL
INSULATION 12/21/2023 APPROVED FWILLIS
Note: 12/21/23 - ITEMS CORRECTED Inspector Notes from Inspection 2320 Inspector Notes from Inspection 2420 12/18/23- Please install Plumbing NP at spare bath vent pipe at top plate. Please install Blocking at top of Breaker panel chase for romex protection and firestop. will check at insulation.
LATH/BRICK/ WATER BARRIER 12/19/2023 APPROVED - AS NOTED JSTEWART
Note: Inspector Notes from Inspection 2420 12/18/23- Please install Plumbing NP at spare bath vent pipe at top plate. Please install Blocking at top of Breaker panel chase for romex protection and firestop. will check at insulation.
ALL ROUGH 12/18/2023 APPROVED - AS NOTED JSTEWART
Note: 12/18/23- Please install Plumbing NP at spare bath vent pipe at top plate. Please install Blocking at top of Breaker panel chase for romex protection and firestop. will check at insulation.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/11/2023 APPROVED FWILLIS
ROOF VALLEY & METAL 12/08/2023 APPROVED JSTEWART
ROOF SHEATHING 12/06/2023 APPROVED FWILLIS
WALL SHEATHING 12/06/2023 APPROVED FWILLIS
FOUND SURVEY APPROVED (OFFICE) 12/05/2023 APPROVED TBAKER
TIE BEAM / LINTEL 11/28/2023 APPROVED JSTEWART
MONOLITHIC SLAB 11/16/2023 APPROVED FWILLIS
GRAVITY SEWER TEST 11/14/2023 Disapproved - NO FEE MGIBSON
Note: 11/13/2023 - PREVIOUS INSPECTION NOTES sewer not ran yet
PLUMBING 1ST ROUGH UNDERGROUND 11/14/2023 APPROVED MGIBSON
Note: 11/13/2023 - PREVIOUS INSPECTION NOTES
GRAVITY SEWER TEST 11/13/2023 CANCELLED BY APPLICANT MGIBSON
PLUMBING 1ST ROUGH UNDERGROUND 11/13/2023 CANCELLED BY APPLICANT MGIBSON
WATER METER INSTALLATION REQUEST 10/31/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
BLD COMPLETE 02/22/2024 02/22/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/05/2023 12/05/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/05/2023 12/05/2023
Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM
BLD HOLD 11/08/2023 11/13/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. What are the changes in the plan? there were no comments asking for changes?
ZON COMPLETE 10/12/2023 10/13/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
BLD COMPLETE 10/12/2023 10/14/2023
Note: Released By: JPI
ENGIN1 COMPLETE 10/12/2023 10/13/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 10/12/2023 10/18/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON HOLD 10/10/2023 10/10/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Site plan missing rear setback All windows and doors facing right of way must have banding. This house backs to a street. Additional foundation plantings required along the rear as this backs to a right of way
ELEC COMPLETE 10/10/2023 10/10/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 10/10/2023 10/10/2023
Note: Released By: JPI
MECH COMPLETE 10/10/2023 10/11/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
BLD HOLD 09/07/2023 09/11/2023
Note: Held By: JPI 1. Per City Truss Submittal Requirements dated April 15, 2023, provide the truss plan packet signed and sealed by a licensed design professional including a completed shop drawing approval stamp on the truss cover sheet.
CUSVC COMPLETE 09/07/2023 09/08/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC HOLD 09/07/2023 09/11/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Need switch for exterior lights in hallway by bed 2. NEC 2017 210.70
ENGIN1 COMPLETE 09/07/2023 09/07/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 09/07/2023 09/11/2023
LOCATE COMPLETE 09/07/2023 09/12/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH HOLD 09/07/2023 09/12/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Direction house faces on Energy Calcs does not match the site plan. Revise to match per R405.4.2.1 FBC Energy Conservation 2020 7Th Edition
SW1 COMPLETE 09/07/2023 09/07/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON HOLD 09/07/2023 09/07/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Landscape plan: please add i shade tree to the plan as there are 4 understorys and no shade tree Site plan: missing rear setback please provide
BADMIN COMPLETE 09/07/2023 09/12/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
SWALE COMPLETE 09/07/2023 10/24/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 03/05/2024
SW ENG REINSPECTION 30 ¤30.00 03/05/2024
SW ENG - REVIEW 20 ¤20.00 10/20/2023
SW ENG RES REVIEW 200 ¤200.00 10/20/2023
SEWER CREDIT (¤850.00) 10/20/2023
SEWER INSPECTION ¤25.00 10/20/2023
SEWER CAPITAL FACILITY ¤5,344.82 10/20/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 10/20/2023
SITE PLAN 30 ¤30.00 10/20/2023
FC IMPACT FEE EMS ¤62.00 10/20/2023
IMPACT FEE FIRE ¤428.09 10/20/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 10/20/2023
FC IMPACT FEE LIBRARY ¤268.00 10/20/2023
IMPACT FEE PARKS ¤1,800.99 10/20/2023
IMPACT FEE SCHOOL ¤5,450.00 10/20/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 10/20/2023
WATER -IRRIGATION INSPECTION ¤25.00 10/20/2023
SURCHARGE FS 533.721 ¤5.34 10/20/2023
SURCHARGE - FS 468.631 ¤8.01 10/20/2023
SW ENG - FOUNDATION SURVEY ¤20.00 10/20/2023
SW ENG INSPECTION 80 ¤80.00 10/20/2023
SW ENG PRE APRON ¤30.00 10/20/2023
WATER- TURN ON ¤25.00 10/20/2023
ADJUSTMENT 50% (¤533.91) 10/20/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/20/2023
INSPECTION - RESIDENTIAL ¤808.50 10/20/2023
PLAN REVIEW - RESIDENTIAL ¤229.32 10/20/2023
CONNECTION FEES ¤1,166.26 10/20/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,676.30