I want to search for...

Permit #2023090222

Permit Details

Status: COED

Parcel Id: 07-11-31-7024-00460-0030
CONDITIONED SPACE: 2052 sqft
GARAGE: 407 sqft
OPENED PORCH (WITH ROOF) : 16 sqft
Total Square Footage: 2475 sqft
Block: 00460
Subdivision: 2167 - SECTION 24-PINE GROVE
Job Phone: 904-268-7730
Location Address: 111 PRITCHARD DR
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/25/2023
NOC: RECORDED
Applicant name: SCOTT CHRISTIAN HOWARD
Owner: FOCUS HOMES LLC OF FLORIDA

Address

5220 SHAD ROAD

JACKSONVILLE, FL 32257

Lot: 0030
Contracted Stated Job Value: ¤195,000.00
Job Description: Single Family Residence
Type: CN

Contractor

FOCUS HOMES LLC OF FLORIDA
Status Location Address Mailing Address State License Number Phone
ACTIVE

5220 SHAD RD

JACKSONVILLE, FL 32257

# 202

JACKSONVILLE, FL 32257

CRC1332443 (Exp: 08/31/2026) 904-268-7730

Sub Contractors

RONALD KEVIN HAUPT
Status Location Address State License Number Phone
ACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

CAC058534 (Exp: 08/31/2026) 407-321-0064
DANIEL GREGORY PUGLISI
Status Location Address State License Number Phone
INACTIVE

4005 MARONDA WAY

SANFORD, FL 32771

EC13011195 (Exp: 08/31/2024) 407-302-7800
DANA SUE COOLEY
Status Location Address State License Number Phone
INACTIVE

PO BOX 1718

FLAGLER BEACH, FL 32136

CCC1333449 (Exp: 08/31/2026) 904-535-1680
GLEN WILLIAM KEHLE
Status Location Address State License Number Phone Fax
ACTIVE

P. O. Box 353511

BUNNELL, FL 32110

CFC057241 (Exp: 08/31/2026) (386) 447-4249 (386) 437-8488

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 02/28/2024 FINAL APPROVED RSIMS
Note: New inspection due to canceled inspection 2/22/2024 - PREVIOUS INSPECTION NOTES 2/22/24: Please walk your house in entirety to verify it is 100% ready before calling in Building Final Inspections as Building Inspectors are not required to provide Punch Lists for Superintendents and/or Builders. 1). Range anti-tip device is not installed properly. (large gap between bottom & floor and anchors pulling out). Please secure properly to the bottom plate or tapcon to the floor as required by the Manufacturer. 2). Garage door opener - safety eyes are above the 6" (From Finished Floor) maximum as required by UL 325.6 / 16CFR part 1211. 3). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 4). Missing termite final certification. 5). #6 ground wire needs to be fully protected from footer steel into the Meter panel per NEC 250-92. 6). OD Condensing Unit: Anchor has a broken tapcon into pad. M1307.2 7). Hall bathroom: Tub spout is not sealed as required. FBC-P2705.1(3) (Where fixtures come in contact with walls and floors, the contact shall be water tight.) 8). TUG Outlet is not identified as required. NEC 408.4 (A) 9). Missing 'J' channel at all exterior outlet boxes (including front entry) and hose bibbs allowing water to penetrate behind the siding. Plaster ring style boxes installed are designed for stucco but not vinyl siding as they are too deep and not adjustable. 7).
ROW - FINAL APRON (AFTER POUR) 02/28/2024 APPROVED - AS NOTED PFLANAGAN
Note: THE APRON IS STILL EXCEEDS THE 8% SLOPE BUT WE A LETTING THE BUILDER TO CO THIS HOUSE THEY HAVE PULLED A DRIVEWAY PERMIT FOR THE CORRECTION OF THE APRON THE PERMIT NUMBER IS 2024021189. WE WILL BE INSPECTING THIS UNDER THE DRIVEWAY PERMIT FROM HERE ON OUT. ---------------------------------------------------------------------------------------------- 2/22/2024 - PREVIOUS INSPECTION NOTES THE APRON OF THE DRIVEWAY EXCEEDS THE 8% SLOPE ----------------------------------------------------------------------------- 2/16/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO DO THE HOT PATCH FOR THE ROAD DAMAGE 2) THE APRON OF THE DRIVEWAY EXCEEDS THE 8% SLOPE NEED TO FIX PLEASE SEE NOTES ON THE SWALE PLAN DETAIL FOR ALL THINGS REQUIRED FOR THE PRE POUR --------------------------------------------------------------------------------------------- 2/15/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO DO THE HOT PATCH FOR THE ROAD DAMAGE 2) THE APRON OF THE DRIVEWAY EXCEEDS THE 8% SLOPE NEED TO FIX
BLD - BUILDING FINAL 02/27/2024 CANCELLED BY APPLICANT WEB
Note: 2/22/2024 - PREVIOUS INSPECTION NOTES 2/22/24: Please walk your house in entirety to verify it is 100% ready before calling in Building Final Inspections as Building Inspectors are not required to provide Punch Lists for Superintendents and/or Builders. 1). Range anti-tip device is not installed properly. (large gap between bottom & floor and anchors pulling out). Please secure properly to the bottom plate or tapcon to the floor as required by the Manufacturer. 2). Garage door opener - safety eyes are above the 6" (From Finished Floor) maximum as required by UL 325.6 / 16CFR part 1211. 3). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 4). Missing termite final certification. 5). #6 ground wire needs to be fully protected from footer steel into the Meter panel per NEC 250-92. 6). OD Condensing Unit: Anchor has a broken tapcon into pad. M1307.2 7). Hall bathroom: Tub spout is not sealed as required. FBC-P2705.1(3) (Where fixtures come in contact with walls and floors, the contact shall be water tight.) 8). TUG Outlet is not identified as required. NEC 408.4 (A) 9). Missing 'J' channel at all exterior outlet boxes (including front entry) and hose bibbs allowing water to penetrate behind the siding. Plaster ring style boxes installed are designed for stucco but not vinyl siding as they are too deep and not adjustable. 7).
ROW- PROJECT STATUS 02/26/2024 APPROVED PFLANAGAN
Note: MEETING DOYAL ON SITE ABOUT DRIVEWAY APRON
ROW - FINAL APRON (AFTER POUR) 02/22/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: THE APRON OF THE DRIVEWAY EXCEEDS THE 8% SLOPE ----------------------------------------------------------------------------- 2/16/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO DO THE HOT PATCH FOR THE ROAD DAMAGE 2) THE APRON OF THE DRIVEWAY EXCEEDS THE 8% SLOPE NEED TO FIX PLEASE SEE NOTES ON THE SWALE PLAN DETAIL FOR ALL THINGS REQUIRED FOR THE PRE POUR --------------------------------------------------------------------------------------------- 2/15/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO DO THE HOT PATCH FOR THE ROAD DAMAGE 2) THE APRON OF THE DRIVEWAY EXCEEDS THE 8% SLOPE NEED TO FIX
U -UTILITY RESIDENTIAL FINAL 02/22/2024 FINAL APPROVED LFITZGERALD
U-CROSS CONNECTION 02/22/2024 APPROVED - AS NOTED LFITZGERALD
Note: no irr-no cross connection
BLD - BUILDING FINAL 02/22/2024 Disapproved -FEE REQUIRED RSIMS
Note: 2/22/24: Please walk your house in entirety to verify it is 100% ready before calling in Building Final Inspections as Building Inspectors are not required to provide Punch Lists for Superintendents and/or Builders. 1). Range anti-tip device is not installed properly. (large gap between bottom & floor and anchors pulling out). Please secure properly to the bottom plate or tapcon to the floor as required by the Manufacturer. 2). Garage door opener - safety eyes are above the 6" (From Finished Floor) maximum as required by UL 325.6 / 16CFR part 1211. 3). Water Heater Relief Valve Discharge tube is too long per FBC- P504.6 (1.5" min / 6" max 0ff floor). 4). Missing termite final certification. 5). #6 ground wire needs to be fully protected from footer steel into the Meter panel per NEC 250-92. 6). OD Condensing Unit: Anchor has a broken tapcon into pad. M1307.2 7). Hall bathroom: Tub spout is not sealed as required. FBC-P2705.1(3) (Where fixtures come in contact with walls and floors, the contact shall be water tight.) 8). TUG Outlet is not identified as required. NEC 408.4 (A) 9). Missing 'J' channel at all exterior outlet boxes (including front entry) and hose bibbs allowing water to penetrate behind the siding. Plaster ring style boxes installed are designed for stucco but not vinyl siding as they are too deep and not adjustable. 7).
FINAL SURVEY (OFFICE USE ONLY) 02/21/2024 APPROVED PFLANAGAN
Note: THIS FINAL SURVEY HAS PASS ALREADY
U - SEWER TIE IN 02/20/2024 APPROVED MGIBSON
Note: Inspector Notes from Inspection 2075 New inspection due to canceled inspection 1/12/2024 - PREVIOUS INSPECTION NOTES 1/10/2024 - PREVIOUS INSPECTION NOTES 10/20/2023 - PREVIOUS INSPECTION NOTES SEWER NOT RAN YET NO TEST ON SEWER SEWER RAN ACROSS DRIVEWAY TAP IS ON THE SAME SIDE AS WATER METER PIT
ROW - STORMWATER FINAL 02/16/2024 APPROVED PFLANAGAN
Note: CORRECTION MADE -------------------------------------------------------------- 2/15/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANTS SURROUNDING YOUR LOT
ROW - FINAL APRON (AFTER POUR) 02/16/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO DO THE HOT PATCH FOR THE ROAD DAMAGE 2) THE APRON OF THE DRIVEWAY EXCEEDS THE 8% SLOPE NEED TO FIX PLEASE SEE NOTES ON THE SWALE PLAN DETAIL FOR ALL THINGS REQUIRED FOR THE PRE POUR --------------------------------------------------------------------------------------------- 2/15/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO DO THE HOT PATCH FOR THE ROAD DAMAGE 2) THE APRON OF THE DRIVEWAY EXCEEDS THE 8% SLOPE NEED TO FIX
ROW - FINAL APRON (AFTER POUR) 02/15/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) NEED TO DO THE HOT PATCH FOR THE ROAD DAMAGE 2) THE APRON OF THE DRIVEWAY EXCEEDS THE 8% SLOPE NEED TO FIX
ROW - STORMWATER FINAL 02/15/2024 Disapproved - NO FEE PFLANAGAN
Note: 1) NEED TO PICK UP ALL TRASH AND CONSTRUCTION DEBRIS FROM VACANTS SURROUNDING YOUR LOT
ROW- FINAL SURVEY/GRADING CERTIFICATION 02/13/2024 APPROVED TPOLACEK
Note: 02/13/24 Inspector Notes from Inspection 9270 1/26/24 PIPE IS GOOD. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
ROW FIELD SURVEY /GRADING CERTIFICATION 02/13/2024 APPROVED TPOLACEK
Note: 02/13/24 AT THE TIME FROM THE TIME OF THE INSPECTION OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. AS A NOTE THE DRIVEWAY APRON IN THE CENTER LINE EXCEEDS THE 8% SLOPE MAX. PLEASE SEE ATTACHED 300E CITY TECH CODE. APRON MAY NOT EXCEED 8% SLOPE THE SLOPE AT 111 PRITCHARD IS 9.1%.
ROW- PRE-APRON (PRE-POUR) 01/30/2024 CANCELLED BY APPLICANT WEB
ROW- PRE-APRON (PRE-POUR) 01/26/2024 APPROVED - AS NOTED FSLADISH
Note: 1/26/24 PIPE IS GOOD. READY TO POUR AT THE TIME OF THIS INSPECTION. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour.
U - SEWER TIE IN 01/25/2024 CANCELLED BY APPLICANT WEB
Note: New inspection due to canceled inspection 1/12/2024 - PREVIOUS INSPECTION NOTES 1/10/2024 - PREVIOUS INSPECTION NOTES TAP NOT MADE
GRAVITY SEWER TEST 01/25/2024 APPROVED - AS NOTED MGIBSON
Note: New inspection due to canceled inspection 1/12/2024 - PREVIOUS INSPECTION NOTES 1/10/2024 - PREVIOUS INSPECTION NOTES 10/20/2023 - PREVIOUS INSPECTION NOTES SEWER NOT RAN YET NO TEST ON SEWER SEWER RAN ACROSS DRIVEWAY TAP IS ON THE SAME SIDE AS WATER METER PIT
GRAVITY SEWER TEST 01/23/2024 CANCELLED BY APPLICANT WEB
Note: 1/12/2024 - PREVIOUS INSPECTION NOTES 1/10/2024 - PREVIOUS INSPECTION NOTES 10/20/2023 - PREVIOUS INSPECTION NOTES SEWER NOT RAN YET NO TEST ON SEWER
U - SEWER TIE IN 01/23/2024 CANCELLED BY APPLICANT WEB
Note: 1/12/2024 - PREVIOUS INSPECTION NOTES 1/10/2024 - PREVIOUS INSPECTION NOTES TAP NOT MADE
ELECTRIC - EARLY POWER 01/17/2024 APPROVED JWALKER
Note: 1/16/2024 - PREVIOUS INSPECTION NOTES Panel cover is not installed 11/17/2023 - PREVIOUS INSPECTION NOTES No meter can or pedestal installed
ELECTRIC - EARLY POWER 01/16/2024 Disapproved -FEE REQUIRED RMARTIN
Note: Panel cover is not installed 11/17/2023 - PREVIOUS INSPECTION NOTES No meter can or pedestal installed
GRAVITY SEWER TEST 01/12/2024 CANCELLED BY APPLICANT MGIBSON
Note: 1/10/2024 - PREVIOUS INSPECTION NOTES 10/20/2023 - PREVIOUS INSPECTION NOTES SEWER NOT RAN YET NO TEST ON SEWER
U - SEWER TIE IN 01/12/2024 CANCELLED BY APPLICANT MGIBSON
Note: 1/10/2024 - PREVIOUS INSPECTION NOTES TAP NOT MADE
U - SEWER TIE IN 01/10/2024 Disapproved - NO FEE MGIBSON
Note: TAP NOT MADE
GRAVITY SEWER TEST 01/10/2024 Disapproved -FEE REQUIRED MGIBSON
Note: 10/20/2023 - PREVIOUS INSPECTION NOTES SEWER NOT RAN YET NO TEST ON SEWER
INSULATION 12/07/2023 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2420 Missing wall stud between owner suite and great room.
LATH/BRICK/ WATER BARRIER 11/30/2023 APPROVED KSANDOE
ALL ROUGH 11/30/2023 APPROVED - AS NOTED KSANDOE
Note: Missing wall stud between owner suite and great room.
ROOF VALLEY & METAL 11/27/2023 APPROVED BTAYLOR
Note: 11/22/2023 - PREVIOUS INSPECTION NOTES Not ready. No drip edge or valley metal
ROOF VALLEY & METAL 11/22/2023 Disapproved - NO FEE KSANDOE
Note: Not ready. No drip edge or valley metal
ELECTRIC-TUG 11/22/2023 APPROVED - AS NOTED KSANDOE
Note: Emailed FPL @ 1052. Release Power New inspection due to canceled inspection 11/17/2023 - PREVIOUS INSPECTION NOTES No meter can or pedestal installed
ELECTRIC-TUG 11/21/2023 CANCELLED BY APPLICANT WEB
Note: 11/17/2023 - PREVIOUS INSPECTION NOTES No meter can or pedestal installed
ELECTRIC-TUG 11/17/2023 Disapproved - NO FEE KSANDOE
Note: No meter can or pedestal installed
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/17/2023 APPROVED KSANDOE
Note: 11/15/2023 - PREVIOUS INSPECTION NOTES
WALL SHEATHING 11/15/2023 APPROVED KSANDOE
Note: Inspector Notes from Inspection 2465 11/13/23: Roof Sheathing approved during seperate Roof Sheathing Inspection. I could not add this note to 2460 Roof Sheathing/Braces/Ties/Down Cell because it is already scheduled for 11/15/23.
ROOF SHEATHING / BRACES/TIES/DOWN CELL 11/15/2023 CANCELLED BY APPLICANT KSANDOE
ROOF SHEATHING 11/13/2023 APPROVED - AS NOTED RSIMS
Note: 11/13/23: Roof Sheathing approved during seperate Roof Sheathing Inspection. I could not add this note to 2460 Roof Sheathing/Braces/Ties/Down Cell because it is already scheduled for 11/15/23.
WALL SHEATHING 11/13/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/13/23: Need dumpster on site and trash piles cleaned up prior to any further approved inspections. Wall Sheathing not attached at Garage Door Portal Frame as required on plan page SD-1.
MONOLITHIC SLAB 10/27/2023 APPROVED KSANDOE
Note: 10/26/2023 - PREVIOUS INSPECTION NOTES No change 10/25/2023 - PREVIOUS INSPECTION NOTES Cave ins noted yesterday are still present. Large root on righ side protruding into foundation must be removed Root sticking up from below nearf hose bib on left side must be removed 10/24/2023 - PREVIOUS INSPECTION NOTES Several areas of foundation wall have caved in
MONOLITHIC SLAB 10/27/2023 CANCELLED BY APPLICANT WEB
MONOLITHIC SLAB 10/26/2023 Disapproved -FEE REQUIRED KSANDOE
Note: No change 10/25/2023 - PREVIOUS INSPECTION NOTES Cave ins noted yesterday are still present. Large root on righ side protruding into foundation must be removed Root sticking up from below nearf hose bib on left side must be removed 10/24/2023 - PREVIOUS INSPECTION NOTES Several areas of foundation wall have caved in
MONOLITHIC SLAB 10/25/2023 Disapproved -FEE REQUIRED KSANDOE
Note: Cave ins noted yesterday are still present. Large root on righ side protruding into foundation must be removed Root sticking up from below nearf hose bib on left side must be removed 10/24/2023 - PREVIOUS INSPECTION NOTES Several areas of foundation wall have caved in
MONOLITHIC SLAB 10/24/2023 Disapproved - NO FEE KSANDOE
Note: Several areas of foundation wall have caved in
FOUND SURVEY APPROVED (OFFICE) 10/23/2023 APPROVED TBAKER
PLUMBING 1ST ROUGH UNDERGROUND 10/23/2023 CANCELLED BY APPLICANT WEB
GRAVITY SEWER TEST 10/23/2023 CANCELLED BY APPLICANT WEB
GRAVITY SEWER TEST 10/20/2023 Disapproved - NO FEE MGIBSON
Note: SEWER NOT RAN YET
PLUMBING 1ST ROUGH UNDERGROUND 10/20/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 10/04/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
ENGIN1 COMPLETE 10/23/2023 10/23/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 10/23/2023 10/23/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 COMPLETE 10/05/2023 10/06/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
ZON COMPLETE 10/05/2023 10/05/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 09/08/2023 10/26/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/08/2023 09/08/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BLD COMPLETE 09/07/2023 09/10/2023
Note: Released By: JPI
CUSVC COMPLETE 09/07/2023 09/08/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 09/07/2023 09/11/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/07/2023 09/08/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 09/07/2023 09/11/2023
LOCATE COMPLETE 09/07/2023 09/12/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 09/07/2023 09/12/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 09/07/2023 09/19/2023
Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM
BADMIN COMPLETE 09/07/2023 09/11/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤20.00 02/28/2024
REINSPECTION RESIDENTIAL ¤40.00 02/28/2024
REINSPECTION RESIDENTIAL ¤40.00 02/28/2024
REINSPECTION RESIDENTIAL ¤40.00 02/28/2024
REINSPECTION RESIDENTIAL ¤40.00 02/28/2024
REINSPECTION RESIDENTIAL ¤40.00 02/28/2024
REINSPECTION RESIDENTIAL ¤40.00 02/28/2024
SW ENG REINSPECTION 20 ¤20.00 02/28/2024
SW ENG REINSPECTION 20 ¤20.00 02/28/2024
SW ENG REINSPECTION 20 ¤20.00 02/28/2024
SW ENG REINSPECTION 20 ¤20.00 02/28/2024
SW ENG - REVIEW 20 ¤20.00 09/25/2023
SW ENG RES REVIEW 200 ¤200.00 09/25/2023
TRANS IMPACT FEE ADMIN ¤54.36 09/25/2023
TRANS IMPACT FEE ADMIN (¤54.36) 09/25/2023
SEWER INSPECTION ¤25.00 09/25/2023
SEWER CAPITAL FACILITY ¤5,344.82 09/25/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 09/25/2023
SITE PLAN 30 ¤30.00 09/25/2023
CONNECTION FEES ¤1,166.26 09/25/2023
WATER- TURN ON ¤25.00 09/25/2023
ADJUSTMENT 50% (¤671.58) 09/25/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/25/2023
INSPECTION - RESIDENTIAL ¤1,023.00 09/25/2023
PLAN REVIEW - RESIDENTIAL ¤290.16 09/25/2023
CONTRACTOR CHANGE ¤20.00 09/25/2023
FIRE IMPACT FEE ADMIN ¤12.62 09/25/2023
FIRE IMPACT FEE ADMIN (¤12.62) 09/25/2023
FC IMPACT FEE EMS ¤62.00 09/25/2023
IMPACT FEE FIRE ¤420.52 09/25/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 09/25/2023
FC IMPACT FEE LIBRARY ¤268.00 09/25/2023
IMPACT FEE PARKS ¤1,769.15 09/25/2023
IMPACT FEE SCHOOL ¤5,450.00 09/25/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 09/25/2023
WATER -IRRIGATION INSPECTION ¤25.00 09/25/2023
PARKS IMPACT FEE ADMIN ¤53.07 09/25/2023
PARKS IMPACT FEE ADMIN (¤53.07) 09/25/2023
SURCHARGE FS 533.721 ¤6.72 09/25/2023
SURCHARGE - FS 468.631 ¤10.07 09/25/2023
SW ENG - FOUNDATION SURVEY ¤20.00 09/25/2023
SW ENG INSPECTION 80 ¤80.00 09/25/2023
SW ENG PRE APRON ¤30.00 09/25/2023
Fees Total Due: ¤0.00 Total Paid: ¤21,938.00