Permit #2023090230
Permit Details
Status: COED
| Parcel Id: 07-11-31-7023-00240-0130 |
| CONDITIONED SPACE: 2052 sqft |
| GARAGE: 407 sqft |
| OPENED PORCH (WITH ROOF) : 16 sqft |
| Total Square Footage: 2475 sqft |
| Block: 00240 |
| Subdivision: 2191 - SECTION 23-WYNNFIELD |
| Job Phone: 904-268-7730 |
| Location Address: 18 WHITTIER LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 09/25/2023 |
| NOC: RECORDED |
| Applicant name: SCOTT CHRISTIAN HOWARD |
| Owner: FOCUS HOMES LLC OF FLORIDA |
|
Address 5220 SHAD ROAD JACKSONVILLE, FL 32257 |
| Lot: 0130 |
| Contracted Stated Job Value: ¤195,000.00 |
| Job Description: Single Family Residence |
| Type: CN |
Contractor
FOCUS HOMES LLC OF FLORIDA
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
5220 SHAD RD JACKSONVILLE, FL 32257 |
# 202 JACKSONVILLE, FL 32257 |
CRC1332443 (Exp: 08/31/2026) | 904-268-7730 |
Sub Contractors
DANA SUE COOLEY
| Status | Location Address | State License Number | Phone |
| INACTIVE |
PO BOX 1718 FLAGLER BEACH, FL 32136 |
CCC1333449 (Exp: 08/31/2026) | 904-535-1680 |
RONALD KEVIN HAUPT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CAC058534 (Exp: 08/31/2026) | 407-321-0064 |
CLINTON J HULSLANDER SR
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
4005 MARONDA WAY SANFORD, FL 32771 |
CFC1430632 (Exp: 08/31/2026) | 407-321-0064 | 407-688-8534 |
JAMES M GREENSLADE
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
311 S BAY ST BUNNELL, FL 32110 |
EC13006083 (Exp: 08/31/2026) | 386-263-2960 | 386-263-2980 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - STORMWATER FINAL | 03/06/2024 | APPROVED | EMADISON |
| Note: | |||
| ROW - STORMWATER FINAL | 03/01/2024 | CANCELLED BY APPLICANT | WEB |
| Note: 2/28/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9465 02/27/24 PLEASE READ PREVIOUS NOTES AND MAKE CORRECTION TO LEFT SIDE SWALE. SOD MUST MATCH GRADE AT PROPERTY LINE. ** STILL NEEDS HOT PATCH BEFORE AFTER POUR AND FINAL ROW ** APPROVING AS NOTED TO MAKE CORRECTIONS 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola Inspector Notes from Inspection 9465 02/27/24 PLEASE READ PREVIOUS NOTES AND MAKE CORRECTION TO LEFT SIDE SWALE. SOD MUST MATCH GRADE AT PROPERTY LINE. ** STILL NEEDS HOT PATCH BEFORE AFTER POUR AND FINAL ROW ** APPROVING AS NOTED TO MAKE CORRECTIONS 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola | |||
| ROW - STORMWATER FINAL | 03/01/2024 | CANCELLED BY APPLICANT | TPOLACEK |
| Note: 03/01/24 recieved text cancelling inspection 2/29/2024 - PREVIOUS INSPECTION NOTES 1) STILL NEED TO DO HOT PATCH FOR ROAD DAMAGE ----------------------------------------------------------------------------------------- 2/28/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9465 02/27/24 PLEASE READ PREVIOUS NOTES AND MAKE CORRECTION TO LEFT SIDE SWALE. SOD MUST MATCH GRADE AT PROPERTY LINE. ** STILL NEEDS HOT PATCH BEFORE AFTER POUR AND FINAL ROW ** APPROVING AS NOTED TO MAKE CORRECTIONS 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola Inspector Notes from Inspection 9465 02/27/24 PLEASE READ PREVIOUS NOTES AND MAKE CORRECTION TO LEFT SIDE SWALE. SOD MUST MATCH GRADE AT PROPERTY LINE. ** STILL NEEDS HOT PATCH BEFORE AFTER POUR AND FINAL ROW ** APPROVING AS NOTED TO MAKE CORRECTIONS 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola | |||
| ROW - STORMWATER FINAL | 02/29/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: 1) STILL NEED TO DO HOT PATCH FOR ROAD DAMAGE ----------------------------------------------------------------------------------------- 2/28/2024 - PREVIOUS INSPECTION NOTES Inspector Notes from Inspection 9465 02/27/24 PLEASE READ PREVIOUS NOTES AND MAKE CORRECTION TO LEFT SIDE SWALE. SOD MUST MATCH GRADE AT PROPERTY LINE. ** STILL NEEDS HOT PATCH BEFORE AFTER POUR AND FINAL ROW ** APPROVING AS NOTED TO MAKE CORRECTIONS 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola Inspector Notes from Inspection 9465 02/27/24 PLEASE READ PREVIOUS NOTES AND MAKE CORRECTION TO LEFT SIDE SWALE. SOD MUST MATCH GRADE AT PROPERTY LINE. ** STILL NEEDS HOT PATCH BEFORE AFTER POUR AND FINAL ROW ** APPROVING AS NOTED TO MAKE CORRECTIONS 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola | |||
| BLD - BUILDING FINAL | 02/29/2024 | FINAL APPROVED | MKRASKI |
| ROW - FINAL APRON (AFTER POUR) | 02/28/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 2/28/24 PIPE IS GOOD. CUTS MADE. CULVERT CLEAR. HOT PATCH NOT COMPLETED, WILL NEED TO BE COMPLETED BEFORE ROW FINAL PASSAGE. Inspector Notes from Inspection 9465 02/27/24 PLEASE READ PREVIOUS NOTES AND MAKE CORRECTION TO LEFT SIDE SWALE. SOD MUST MATCH GRADE AT PROPERTY LINE. ** STILL NEEDS HOT PATCH BEFORE AFTER POUR AND FINAL ROW ** APPROVING AS NOTED TO MAKE CORRECTIONS 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola Inspector Notes from Inspection 9465 02/27/24 PLEASE READ PREVIOUS NOTES AND MAKE CORRECTION TO LEFT SIDE SWALE. SOD MUST MATCH GRADE AT PROPERTY LINE. ** STILL NEEDS HOT PATCH BEFORE AFTER POUR AND FINAL ROW ** APPROVING AS NOTED TO MAKE CORRECTIONS 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola | |||
| BLD - BUILDING FINAL | 02/28/2024 | Disapproved - NO FEE | MKRASKI |
| Note: Drywall repair in garage needs to be finished | |||
| U -UTILITY RESIDENTIAL FINAL | 02/28/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: Inspector Notes from Inspection 9035 lower sewer C/O-pic it to me when done no irr-no cross connection | |||
| ROW - STORMWATER FINAL | 02/28/2024 | CANCELLED BY APPLICANT | FSLADISH |
| Note: Inspector Notes from Inspection 9465 02/27/24 PLEASE READ PREVIOUS NOTES AND MAKE CORRECTION TO LEFT SIDE SWALE. SOD MUST MATCH GRADE AT PROPERTY LINE. ** STILL NEEDS HOT PATCH BEFORE AFTER POUR AND FINAL ROW ** APPROVING AS NOTED TO MAKE CORRECTIONS 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola Inspector Notes from Inspection 9465 02/27/24 PLEASE READ PREVIOUS NOTES AND MAKE CORRECTION TO LEFT SIDE SWALE. SOD MUST MATCH GRADE AT PROPERTY LINE. ** STILL NEEDS HOT PATCH BEFORE AFTER POUR AND FINAL ROW ** APPROVING AS NOTED TO MAKE CORRECTIONS 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola | |||
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 02/27/2024 | APPROVED | TPOLACEK |
| Note: 02/27/24 SURVEY IS GOOD Inspector Notes from Inspection 9200 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola 02/09/24 NOTE TO CONTRACTOR* RIGHT SIDE OF APRON BOARD IS JUST OUTSIDE THE EXISTING EDGE OF PAVEMENT. IF YOU COULD JUST MOVE THIS BACK AN INCH OR TWO TO MATCH THE EXISTING EDGE BEFORE POURING. ALL OTHER REQUIRMENTS ARE GOOD. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. Meeting with Larry Joe 02/09/24 NOTE TO CONTRACTOR* RIGHT SIDE OF APRON BOARD IS JUST OUTSIDE THE EXISTING EDGE OF PAVEMENT. IF YOU COULD JUST MOVE THIS BACK AN INCH OR TWO TO MATCH THE EXISTING EDGE BEFORE POURING. ALL OTHER REQUIRMENTS ARE GOOD. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. meeting with Larry Joe 02/09/24 NOTE TO CONTRACTOR* RIGHT SIDE OF APRON BOARD IS JUST OUTSIDE THE EXISTING EDGE OF PAVEMENT. IF YOU COULD JUST MOVE THIS BACK AN INCH OR TWO TO MATCH THE EXISTING EDGE BEFORE POURING. ALL OTHER REQUIRMENTS ARE GOOD. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 02/27/2024 | APPROVED - AS NOTED | TPOLACEK |
| Note: 02/27/24 PLEASE READ PREVIOUS NOTES AND MAKE CORRECTION TO LEFT SIDE SWALE. SOD MUST MATCH GRADE AT PROPERTY LINE. ** STILL NEEDS HOT PATCH BEFORE AFTER POUR AND FINAL ROW ** APPROVING AS NOTED TO MAKE CORRECTIONS 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola | |||
| U-CROSS CONNECTION | 02/27/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: no irr-no cross connection | |||
| ROW- PROJECT STATUS | 02/15/2024 | APPROVED - AS NOTED | GBERTOLA |
| Note: 2/15/24= ON THE LEFT SIDE, FACING THE HOUSE, THE SWALE SHOULD BE MADE SLIGHTLY DEEPER. THE LOCATION OF THE SWALE IS CORRECT, SO DO NOT CHANGE IT.per gbertola 02/09/24 NOTE TO CONTRACTOR* RIGHT SIDE OF APRON BOARD IS JUST OUTSIDE THE EXISTING EDGE OF PAVEMENT. IF YOU COULD JUST MOVE THIS BACK AN INCH OR TWO TO MATCH THE EXISTING EDGE BEFORE POURING. ALL OTHER REQUIRMENTS ARE GOOD. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. Meeting with Larry Joe 02/09/24 NOTE TO CONTRACTOR* RIGHT SIDE OF APRON BOARD IS JUST OUTSIDE THE EXISTING EDGE OF PAVEMENT. IF YOU COULD JUST MOVE THIS BACK AN INCH OR TWO TO MATCH THE EXISTING EDGE BEFORE POURING. ALL OTHER REQUIRMENTS ARE GOOD. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. meeting with Larry Joe 02/09/24 NOTE TO CONTRACTOR* RIGHT SIDE OF APRON BOARD IS JUST OUTSIDE THE EXISTING EDGE OF PAVEMENT. IF YOU COULD JUST MOVE THIS BACK AN INCH OR TWO TO MATCH THE EXISTING EDGE BEFORE POURING. ALL OTHER REQUIRMENTS ARE GOOD. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. | |||
| ROW- PRE-APRON (PRE-POUR) | 02/12/2024 | CANCELLED BY APPLICANT | WEB |
| ROW- PRE-APRON (PRE-POUR) | 02/09/2024 | APPROVED - AS NOTED | TPOLACEK |
| Note: 02/09/24 NOTE TO CONTRACTOR* RIGHT SIDE OF APRON BOARD IS JUST OUTSIDE THE EXISTING EDGE OF PAVEMENT. IF YOU COULD JUST MOVE THIS BACK AN INCH OR TWO TO MATCH THE EXISTING EDGE BEFORE POURING. ALL OTHER REQUIRMENTS ARE GOOD. AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. | |||
| ELECTRIC - EARLY POWER | 01/30/2024 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 2pm | |||
| ELECTRIC - EARLY POWER | 01/29/2024 | Disapproved - NO FEE | MKRASKI |
| Note: Silt fence needs to be maintained in orginal condition FBC 3307.1 | |||
| GRAVITY SEWER TEST | 01/23/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| U - SEWER TIE IN | 01/23/2024 | APPROVED - AS NOTED | MGIBSON |
| Note: THIS WAS A VIRTUAL INSPECTION | |||
| PEP TANK INSTALLATION REQUEST | 01/02/2024 | APPROVED | TCHURCHILL |
| INSULATION | 12/20/2023 | APPROVED | MKRASKI |
| ALL ROUGH | 12/15/2023 | APPROVED | RSIMS |
| Note: 12/12/2023 - PREVIOUS INSPECTION NOTES 12/2/23 Items 1 and 4 not repaired, Item 1 stud on load bearing wall can not exceed 16'' o.c. per detail, item 4 has not been approved by BUilding Dept. 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23 1. Item 1 not repaired 2. Dryer duct needs to be sealed at roof decking 3. Master bathroom missing A/C supply per e-cals duct layout 4. Product approval sheet does not match windows installed 12/8/2023 - PREVIOUS INSPECTION NOTES 12/8/23 1. Load bearing stud that was installed for stud that was cut is short of top plate 2. Failed 5' head pressure 3. Ufer has been cut, no ground rods installed Stopped inspection not ready 12/7/2023 - PREVIOUS INSPECTION NOTES 12/7/23 Previous items not repaired, stopped inspection 12/6/2023 - PREVIOUS INSPECTION NOTES 1. Metalic boxes ground screw needs to be tightened down to ensure bond 2. Flat straps required where notch has been cut SER cable above panel 3. Load bearinf stud has been cut and needs to be replaced @ ufer ground Stopped inspection in garage not ready | |||
| ALL ROUGH | 12/12/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 12/2/23 Items 1 and 4 not repaired, Item 1 stud on load bearing wall can not exceed 16'' o.c. per detail, item 4 has not been approved by BUilding Dept. 12/11/2023 - PREVIOUS INSPECTION NOTES 12/11/23 1. Item 1 not repaired 2. Dryer duct needs to be sealed at roof decking 3. Master bathroom missing A/C supply per e-cals duct layout 4. Product approval sheet does not match windows installed 12/8/2023 - PREVIOUS INSPECTION NOTES 12/8/23 1. Load bearing stud that was installed for stud that was cut is short of top plate 2. Failed 5' head pressure 3. Ufer has been cut, no ground rods installed Stopped inspection not ready 12/7/2023 - PREVIOUS INSPECTION NOTES 12/7/23 Previous items not repaired, stopped inspection 12/6/2023 - PREVIOUS INSPECTION NOTES 1. Metalic boxes ground screw needs to be tightened down to ensure bond 2. Flat straps required where notch has been cut SER cable above panel 3. Load bearinf stud has been cut and needs to be replaced @ ufer ground Stopped inspection in garage not ready | |||
| ALL ROUGH | 12/11/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 12/11/23 1. Item 1 not repaired 2. Dryer duct needs to be sealed at roof decking 3. Master bathroom missing A/C supply per e-cals duct layout 4. Product approval sheet does not match windows installed 12/8/2023 - PREVIOUS INSPECTION NOTES 12/8/23 1. Load bearing stud that was installed for stud that was cut is short of top plate 2. Failed 5' head pressure 3. Ufer has been cut, no ground rods installed Stopped inspection not ready 12/7/2023 - PREVIOUS INSPECTION NOTES 12/7/23 Previous items not repaired, stopped inspection 12/6/2023 - PREVIOUS INSPECTION NOTES 1. Metalic boxes ground screw needs to be tightened down to ensure bond 2. Flat straps required where notch has been cut SER cable above panel 3. Load bearinf stud has been cut and needs to be replaced @ ufer ground Stopped inspection in garage not ready | |||
| LATH/BRICK/ WATER BARRIER | 12/11/2023 | APPROVED | MKRASKI |
| LATH/BRICK/ WATER BARRIER | 12/08/2023 | Disapproved - NO FEE | MKRASKI |
| Note: Back of home has joints exposed, taper required around outlet box 12/7/2023 - PREVIOUS INSPECTION NOTES 1. Zip tape needs to cover all joints and areas where membrain has been damaged(along the bottomof sheathing) 2. Right front corner woof is showing and needs to be sealed | |||
| ALL ROUGH | 12/08/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 12/8/23 1. Load bearing stud that was installed for stud that was cut is short of top plate 2. Failed 5' head pressure 3. Ufer has been cut, no ground rods installed Stopped inspection not ready 12/7/2023 - PREVIOUS INSPECTION NOTES 12/7/23 Previous items not repaired, stopped inspection 12/6/2023 - PREVIOUS INSPECTION NOTES 1. Metalic boxes ground screw needs to be tightened down to ensure bond 2. Flat straps required where notch has been cut SER cable above panel 3. Load bearinf stud has been cut and needs to be replaced @ ufer ground Stopped inspection in garage not ready | |||
| ALL ROUGH | 12/07/2023 | Disapproved -FEE REQUIRED | MKRASKI |
| Note: 12/7/23 Previous items not repaired, stopped inspection 12/6/2023 - PREVIOUS INSPECTION NOTES 1. Metalic boxes ground screw needs to be tightened down to ensure bond 2. Flat straps required where notch has been cut SER cable above panel 3. Load bearinf stud has been cut and needs to be replaced @ ufer ground Stopped inspection in garage not ready | |||
| LATH/BRICK/ WATER BARRIER | 12/07/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Zip tape needs to cover all joints and areas where membrain has been damaged(along the bottomof sheathing) 2. Right front corner woof is showing and needs to be sealed | |||
| ALL ROUGH | 12/06/2023 | Disapproved - NO FEE | MKRASKI |
| Note: 1. Metalic boxes ground screw needs to be tightened down to ensure bond 2. Flat straps required where notch has been cut SER cable above panel 3. Load bearinf stud has been cut and needs to be replaced @ ufer ground Stopped inspection in garage not ready | |||
| ROOF VALLEY & METAL | 11/29/2023 | CANCELLED BY APPLICANT | WEB |
| ROOF VALLEY & METAL | 11/28/2023 | APPROVED | JWALKER |
| ROOF VALLEY & METAL | 11/28/2023 | CANCELLED BY APPLICANT | WEB |
| ELECTRIC-TUG | 11/22/2023 | APPROVED - AS NOTED | MKRASKI |
| Note: Emailed FPL @ 12:15pm | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/21/2023 | CANCELLED BY APPLICANT | WEB |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 11/17/2023 | APPROVED | FWILLIS |
| ROOF SHEATHING | 11/17/2023 | APPROVED | FWILLIS |
| WALL SHEATHING | 11/17/2023 | APPROVED | FWILLIS |
| MONOLITHIC SLAB | 11/02/2023 | APPROVED | MKRASKI |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/30/2023 | APPROVED | JWALKER |
| Note: 10/27/2023 - PREVIOUS INSPECTION NOTES | |||
| FOUND SURVEY APPROVED (OFFICE) | 10/27/2023 | APPROVED | TBAKER |
| PLUMBING 1ST ROUGH UNDERGROUND | 10/27/2023 | CANCELLED BY APPLICANT | MGIBSON |
| WATER METER INSTALLATION REQUEST | 10/06/2023 | APPROVED | CBOWERMASTER |
Review History
| Department | Status | Date In | Date Out |
| BLD | COMPLETE | 12/11/2023 | 12/13/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 10/27/2023 | 10/27/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/27/2023 | 10/27/2023 |
| Note: Released By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 09/08/2023 | 10/26/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/07/2023 | 09/10/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 09/07/2023 | 09/11/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 09/07/2023 | 09/11/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/07/2023 | 09/08/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 09/07/2023 | 09/11/2023 |
| LOCATE | COMPLETE | 09/07/2023 | 09/12/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 09/07/2023 | 09/12/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 09/07/2023 | 09/19/2023 |
| Note: Released By: FRANK SLADISH - (386)871-6113 - FSLADISH@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/07/2023 | 09/08/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 09/07/2023 | 09/11/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| SW ENG REINSPECTION 20 | ¤20.00 | 03/06/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/28/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/28/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/28/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 02/28/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 02/28/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 02/28/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 02/28/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 02/28/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 02/28/2024 |
| CONTRACTOR CHANGE | ¤20.00 | 02/28/2024 |
| SW ENG REINSPECTION 20 | ¤20.00 | 02/28/2024 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 09/25/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 09/25/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 09/25/2023 |
| IMPACT FEE FIRE | ¤420.52 | 09/25/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 09/25/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 09/25/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 09/25/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 09/25/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 09/25/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 09/25/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 09/25/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 09/25/2023 |
| SURCHARGE FS 533.721 | ¤6.72 | 09/25/2023 |
| SURCHARGE - FS 468.631 | ¤10.07 | 09/25/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 09/25/2023 |
| SW ENG INSPECTION 80 | ¤80.00 | 09/25/2023 |
| SW ENG PRE APRON | ¤30.00 | 09/25/2023 |
| CONNECTION FEES | ¤1,166.26 | 09/25/2023 |
| CONTRACTOR CHANGE | ¤20.00 | 09/25/2023 |
| WATER- TURN ON | ¤25.00 | 09/25/2023 |
| ADJUSTMENT 50% | (¤671.58) | 09/25/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 09/25/2023 |
| INSPECTION - RESIDENTIAL | ¤1,023.00 | 09/25/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤290.16 | 09/25/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 09/25/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 09/25/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 09/25/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 09/25/2023 |
| SEWER CREDIT | (¤1,466.00) | 09/25/2023 |
| SEWER INSPECTION | ¤25.00 | 09/25/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 09/25/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 09/25/2023 |
| SITE PLAN 30 | ¤30.00 | 09/25/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,452.00 |