I want to search for...

Permit #2023090236

Permit Details

Status: COED

Parcel Id: 07-11-31-7065-00500-0050
CONDITIONED SPACE: 2044 sqft
GARAGE: 748 sqft
OPENED PORCH (WITH ROOF) : 555 sqft
Total Square Footage: 3347 sqft
Block: 00500
Subdivision: 2169 - SECTION 65-KANKAKEE RUN
Job Phone: 229-375-9123
Location Address: 1 KATHRYN CT
Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY
Issue Date: 09/12/2023
NOC: RECORDED
Applicant name: WILLIAM ROBERT BARRICK
Owner: JMR III LLC

Address

PO BOX 1347

FLAGLER BEACH, FL 32136

Lot: 0050
Contracted Stated Job Value: ¤282,072.00
Job Description: Single Family Residence
Type: CN

Contractor

RBI HOMES
Status Location Address State License Number Phone
CANCEL

21 CEDARWOOD CT

PALM COAST, FL 32137

RB29003845 (Exp: 08/31/2025) 386-585-4097

Sub Contractors

JONATHAN M PEARSON
Status Location Address State License Number Phone Fax
ACTIVE

209 N FORSYTH ST

BUNNELL, FL 32110

CFC1425941 (Exp: 08/31/2026) 386-597-0944 386-437-4996
WILLIAM ROBERT BARRICK
Status Location Address Mailing Address State License Number Phone
CANCEL

50 LEANNI WAY

PALM COAST, FL 32137

STE E2

PALM COAST, FL 32137

RC29027799 (Exp: 08/31/2025) 229-375-9123
GARY LLOYD SHEFFIELD
Status Location Address State License Number Phone
ACTIVE

PO BOX 912

PALM COAST, FL 32164

CAC1820539 (Exp: 08/31/2026) 386-264-0550
DAVID SCOTT MORRIS
Status Location Address State License Number Phone
INACTIVE

63 LEIDEL DR

PALM COAST, FL 32137

ER13015750 (Exp: 08/31/2026) 386-569-7262

Inspection History

Type Request Date Result Inspector
BLD - BUILDING FINAL 05/15/2024 FINAL APPROVED RSIMS
Note: 5/14/2024 - PREVIOUS INSPECTION NOTES 5/14/24: 1). Panel schedule needs to be corrected to match the panel layout. NEC 408.4 (A) (2020) (A) Circuit Directory or Circuit Identification. Every circuit and circuit modification shall be legibly identified as to its clear, evident and specific purpose or use. The identification shall include an approved degree of detail that allows each circuit to be distinguished from all others. Spare positions ********]
BLD - BUILDING FINAL 05/14/2024 Disapproved - NO FEE RSIMS
Note: 5/14/24: 1). Panel schedule needs to be corrected to match the panel layout. NEC 408.4 (A) (2020) (A) Circuit Directory or Circuit Identification. Every circuit and circuit modification shall be legibly identified as to its clear, evident and specific purpose or use. The identification shall include an approved degree of detail that allows each circuit to be distinguished from all others. Spare positions ********]
ROW - FINAL APRON (AFTER POUR) 05/07/2024 APPROVED - AS NOTED FSLADISH
Note: *** NOTES ADDED BY FSLADISH 5/7/2024 10:42:25 AM *** 5/7/24 PIPE IS GOOD. CUTS MADE. CULVERT HAS A SMALL AMOUNT OF DIRT ON THE RIGHT SIDE, PLEASE REMOVE. HOT PATCH COMPLETED AT THE TIME OF THIS INSPECTION. At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. Inspector Notes from Inspection 9465 *** NOTES ADDED BY FSLADISH 5/6/2024 11:46:48 AM *** 5/6/24 SWALE CORRECTION MADE. DIRT REMOVED FROM AGAINST FENCE. SOD STILL A BIT HIGH ON KATHRYN COURT SIDE. I AM GOING TO APPROVE THIS FIELD SURVAY AS NOTED. DEPENDING ON FIELD CONDITIONS AT NEXT INSPECTION ADDITIONAL CORRECTIONS MAY BE REQUIRED BEFORE A ROW FINAL WILL BE PASSED. 5/2/2024 - PREVIOUS INSPECTION NOTES 1) THE FRONT ROADSIDE SWALE NEED TO BE 8' FROM EDGE OF ROAD. PLEASE DRAWING IN TECHNICAL MANUAL #300.D FOR ROADSIDE SWALE DETAIL. 2) ALL SOD ALONG THE ROAD NEEDS TO BELOW EDGE OF ROAD SO ALL WATER CAN FLOW TO THE ROADSIDE SWALE OFF THE ROAD. PLEASE DRAWING IN TECHNICAL MANUAL #300.D 3) ALL SOD AND DIRT NEEDS TO OFF THE BACK FENCE. 4) NEED TO HAVE 4:1 SLOPE TO THE ADJACENT LOT BEHIND YOURS. 5) THERE IS A SPOT IN BACK RIGHT OF LOT IN THE RIGHT OF WAY THAT NEEDS SOD.
ROW - STORMWATER FINAL 05/07/2024 APPROVED - AS NOTED FSLADISH
Note: *** NOTES ADDED BY FSLADISH 5/7/2024 10:43:24 AM *** 5/7/24 At the time of the inspection all minimum city requirements were met. It is the builders responsibiliy to ensure that nothing changes after this Inspection is approved. Inspector Notes from Inspection 9465 *** NOTES ADDED BY FSLADISH 5/6/2024 11:46:48 AM *** 5/6/24 SWALE CORRECTION MADE. DIRT REMOVED FROM AGAINST FENCE. SOD STILL A BIT HIGH ON KATHRYN COURT SIDE. I AM GOING TO APPROVE THIS FIELD SURVAY AS NOTED. DEPENDING ON FIELD CONDITIONS AT NEXT INSPECTION ADDITIONAL CORRECTIONS MAY BE REQUIRED BEFORE A ROW FINAL WILL BE PASSED. 5/2/2024 - PREVIOUS INSPECTION NOTES 1) THE FRONT ROADSIDE SWALE NEED TO BE 8' FROM EDGE OF ROAD. PLEASE DRAWING IN TECHNICAL MANUAL #300.D FOR ROADSIDE SWALE DETAIL. 2) ALL SOD ALONG THE ROAD NEEDS TO BELOW EDGE OF ROAD SO ALL WATER CAN FLOW TO THE ROADSIDE SWALE OFF THE ROAD. PLEASE DRAWING IN TECHNICAL MANUAL #300.D 3) ALL SOD AND DIRT NEEDS TO OFF THE BACK FENCE. 4) NEED TO HAVE 4:1 SLOPE TO THE ADJACENT LOT BEHIND YOURS. 5) THERE IS A SPOT IN BACK RIGHT OF LOT IN THE RIGHT OF WAY THAT NEEDS SOD.
U -UTILITY RESIDENTIAL FINAL 05/07/2024 FINAL APPROVED JHARDING
Note: Inspector Notes from Inspection 9035 No cross connections.
ROW FIELD SURVEY /GRADING CERTIFICATION 05/06/2024 APPROVED - AS NOTED FSLADISH
Note: *** NOTES ADDED BY FSLADISH 5/6/2024 11:46:48 AM *** 5/6/24 SWALE CORRECTION MADE. DIRT REMOVED FROM AGAINST FENCE. SOD STILL A BIT HIGH ON KATHRYN COURT SIDE. I AM GOING TO APPROVE THIS FIELD SURVAY AS NOTED. DEPENDING ON FIELD CONDITIONS AT NEXT INSPECTION ADDITIONAL CORRECTIONS MAY BE REQUIRED BEFORE A ROW FINAL WILL BE PASSED. 5/2/2024 - PREVIOUS INSPECTION NOTES 1) THE FRONT ROADSIDE SWALE NEED TO BE 8' FROM EDGE OF ROAD. PLEASE DRAWING IN TECHNICAL MANUAL #300.D FOR ROADSIDE SWALE DETAIL. 2) ALL SOD ALONG THE ROAD NEEDS TO BELOW EDGE OF ROAD SO ALL WATER CAN FLOW TO THE ROADSIDE SWALE OFF THE ROAD. PLEASE DRAWING IN TECHNICAL MANUAL #300.D 3) ALL SOD AND DIRT NEEDS TO OFF THE BACK FENCE. 4) NEED TO HAVE 4:1 SLOPE TO THE ADJACENT LOT BEHIND YOURS. 5) THERE IS A SPOT IN BACK RIGHT OF LOT IN THE RIGHT OF WAY THAT NEEDS SOD.
U-CROSS CONNECTION 05/06/2024 APPROVED - AS NOTED JHARDING
Note: No cross connections.
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/02/2024 APPROVED PFLANAGAN
Note: CORRECTION MADE ---------------------------------------------------------- 5/1/2024 - PREVIOUS INSPECTION NOTES YOU NEED TO HAVE INVERTS OF YOUR CULVERT ON YOUR FINAL SURVEY
ROW FIELD SURVEY /GRADING CERTIFICATION 05/02/2024 Disapproved -FEE REQUIRED PFLANAGAN
Note: 1) THE FRONT ROADSIDE SWALE NEED TO BE 8' FROM EDGE OF ROAD. PLEASE DRAWING IN TECHNICAL MANUAL #300.D FOR ROADSIDE SWALE DETAIL. 2) ALL SOD ALONG THE ROAD NEEDS TO BELOW EDGE OF ROAD SO ALL WATER CAN FLOW TO THE ROADSIDE SWALE OFF THE ROAD. PLEASE DRAWING IN TECHNICAL MANUAL #300.D 3) ALL SOD AND DIRT NEEDS TO OFF THE BACK FENCE. 4) NEED TO HAVE 4:1 SLOPE TO THE ADJACENT LOT BEHIND YOURS. 5) THERE IS A SPOT IN BACK RIGHT OF LOT IN THE RIGHT OF WAY THAT NEEDS SOD.
ROW- FINAL SURVEY/GRADING CERTIFICATION 05/01/2024 Disapproved - NO FEE PFLANAGAN
Note: YOU NEED TO HAVE INVERTS OF YOUR CULVERT ON YOUR FINAL SURVEY
ROW- PRE-APRON (PRE-POUR) 04/10/2024 APPROVED TPOLACEK
Note: 04/10/24 AT THE TIME OF THE INSPECTION CULVERT PIPE IS GOOD IS READY TO POUR, IF RAIN PLEASE, BUILDER SHOULD DOUBLE CHECK CULVERT ELEVATIONS MAKE SURE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL BEFORE POURING. -------------------------------------------------------------------------------------------------------------------------- 4/8/2024 - PREVIOUS INSPECTION NOTES 4/4/2024 - PREVIOUS INSPECTION NOTES 04/04/24 site not ready grader is still working on pipe 4/3/2024 - PREVIOUS INSPECTION NOTES 04/03/24 PIPE ON THE RIGHT SIDE IS FLOATING AND NOT COMPACTED AS PER TECH CODE. THERE IS TOO MUCH WATER IN POUR AREA EVEN BEFORE SCHEDULED RAIN FOR THE DAY. ---------------------------------------------------------------------------------------------------------- 4/1/2024 - PREVIOUS INSPECTION NOTES 04/01/24 PIPE NEEDS TO HAVE A MINIMUM OF 5" OF CONCRETE OVER THE TOP ACROTHE ENTIRE LENGTH . SEE PHOTO ATTACHED. YOU NEED TO MAKE CORRECTIONS BEFORE SUBMITTING FOR NEW INSPECTION. ------------------------------------------------------------------------------------------------------------------------------ 3/28/2024 - PREVIOUS INSPECTION NOTES 03/28/24 CREW IS ON SITE PIPE IS OUT OF GROUND. NOT READY FOR INSPECTION 3/27/2024 - PREVIOUS INSPECTION NOTES 03/27/24 CULVERT PIPE IS OUT OF TOLERANCE, TRIPLE CHECKED BM AND CL TO CONFIRM. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
ROW- PRE-APRON (PRE-POUR) 04/08/2024 CANCELLED BY APPLICANT TPOLACEK
Note: 4/4/2024 - PREVIOUS INSPECTION NOTES 04/04/24 site not ready grader is still working on pipe 4/3/2024 - PREVIOUS INSPECTION NOTES 04/03/24 PIPE ON THE RIGHT SIDE IS FLOATING AND NOT COMPACTED AS PER TECH CODE. THERE IS TOO MUCH WATER IN POUR AREA EVEN BEFORE SCHEDULED RAIN FOR THE DAY. ---------------------------------------------------------------------------------------------------------- 4/1/2024 - PREVIOUS INSPECTION NOTES 04/01/24 PIPE NEEDS TO HAVE A MINIMUM OF 5" OF CONCRETE OVER THE TOP ACROTHE ENTIRE LENGTH . SEE PHOTO ATTACHED. YOU NEED TO MAKE CORRECTIONS BEFORE SUBMITTING FOR NEW INSPECTION. ------------------------------------------------------------------------------------------------------------------------------ 3/28/2024 - PREVIOUS INSPECTION NOTES 03/28/24 CREW IS ON SITE PIPE IS OUT OF GROUND. NOT READY FOR INSPECTION 3/27/2024 - PREVIOUS INSPECTION NOTES 03/27/24 CULVERT PIPE IS OUT OF TOLERANCE, TRIPLE CHECKED BM AND CL TO CONFIRM. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
ROW- PRE-APRON (PRE-POUR) 04/04/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 04/04/24 site not ready grader is still working on pipe 4/3/2024 - PREVIOUS INSPECTION NOTES 04/03/24 PIPE ON THE RIGHT SIDE IS FLOATING AND NOT COMPACTED AS PER TECH CODE. THERE IS TOO MUCH WATER IN POUR AREA EVEN BEFORE SCHEDULED RAIN FOR THE DAY. ---------------------------------------------------------------------------------------------------------- 4/1/2024 - PREVIOUS INSPECTION NOTES 04/01/24 PIPE NEEDS TO HAVE A MINIMUM OF 5" OF CONCRETE OVER THE TOP ACROTHE ENTIRE LENGTH . SEE PHOTO ATTACHED. YOU NEED TO MAKE CORRECTIONS BEFORE SUBMITTING FOR NEW INSPECTION. ------------------------------------------------------------------------------------------------------------------------------ 3/28/2024 - PREVIOUS INSPECTION NOTES 03/28/24 CREW IS ON SITE PIPE IS OUT OF GROUND. NOT READY FOR INSPECTION 3/27/2024 - PREVIOUS INSPECTION NOTES 03/27/24 CULVERT PIPE IS OUT OF TOLERANCE, TRIPLE CHECKED BM AND CL TO CONFIRM. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
ROW- PRE-APRON (PRE-POUR) 04/03/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 04/03/24 PIPE ON THE RIGHT SIDE IS FLOATING AND NOT COMPACTED AS PER TECH CODE. THERE IS TOO MUCH WATER IN POUR AREA EVEN BEFORE SCHEDULED RAIN FOR THE DAY. ---------------------------------------------------------------------------------------------------------- 4/1/2024 - PREVIOUS INSPECTION NOTES 04/01/24 PIPE NEEDS TO HAVE A MINIMUM OF 5" OF CONCRETE OVER THE TOP ACROTHE ENTIRE LENGTH . SEE PHOTO ATTACHED. YOU NEED TO MAKE CORRECTIONS BEFORE SUBMITTING FOR NEW INSPECTION. ------------------------------------------------------------------------------------------------------------------------------ 3/28/2024 - PREVIOUS INSPECTION NOTES 03/28/24 CREW IS ON SITE PIPE IS OUT OF GROUND. NOT READY FOR INSPECTION 3/27/2024 - PREVIOUS INSPECTION NOTES 03/27/24 CULVERT PIPE IS OUT OF TOLERANCE, TRIPLE CHECKED BM AND CL TO CONFIRM. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
ROW- PRE-APRON (PRE-POUR) 04/01/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 04/01/24 PIPE NEEDS TO HAVE A MINIMUM OF 5" OF CONCRETE OVER THE TOP ACROTHE ENTIRE LENGTH . SEE PHOTO ATTACHED. YOU NEED TO MAKE CORRECTIONS BEFORE SUBMITTING FOR NEW INSPECTION. ------------------------------------------------------------------------------------------------------------------------------ 3/28/2024 - PREVIOUS INSPECTION NOTES 03/28/24 CREW IS ON SITE PIPE IS OUT OF GROUND. NOT READY FOR INSPECTION 3/27/2024 - PREVIOUS INSPECTION NOTES 03/27/24 CULVERT PIPE IS OUT OF TOLERANCE, TRIPLE CHECKED BM AND CL TO CONFIRM. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
ROW- PRE-APRON (PRE-POUR) 03/28/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 03/28/24 CREW IS ON SITE PIPE IS OUT OF GROUND. NOT READY FOR INSPECTION 3/27/2024 - PREVIOUS INSPECTION NOTES 03/27/24 CULVERT PIPE IS OUT OF TOLERANCE, TRIPLE CHECKED BM AND CL TO CONFIRM. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
ROW- PRE-APRON (PRE-POUR) 03/27/2024 Disapproved -FEE REQUIRED TPOLACEK
Note: 03/27/24 CULVERT PIPE IS OUT OF TOLERANCE, TRIPLE CHECKED BM AND CL TO CONFIRM. Culvert Out of Tolerence Swale Plan #1 Swale Plan #1. The driveway culvert inverts are to be installed within 0.1' (+/-) of the elevations indicated on the swale plan (unless otherwise approved by the City StormwaterEngineer). The finished swale elevation is with sod in place
ELECTRIC - EARLY POWER 03/14/2024 APPROVED RMARTIN
GRAVITY SEWER TEST 02/23/2024 APPROVED MGIBSON
U - SEWER TIE IN 02/23/2024 APPROVED MGIBSON
PEP TANK INSTALLATION REQUEST 02/01/2024 APPROVED BVITALE
LATH/BRICK/ WATER BARRIER 01/26/2024 APPROVED BTAYLOR
Note: 1/25/2024 - PREVIOUS INSPECTION NOTES 1/25/24: 1). Need wire lath installed at all holes in cinderblock for romex & low voltage wiring. Inspector Notes from Inspection 2420 1/17/24: Walked with Superintendent. Check at Insulation. 1). Dryer duct needs to be sealed properly at all fittings, replace fabric straps with metal straps & seal duct at roof deck. 2). Wires for Range, AHU and Condensing unit need to be phased out in panel.
INSULATION 01/26/2024 APPROVED BTAYLOR
Note: 1/25/2024 - PREVIOUS INSPECTION NOTES 1/25/24: 1). Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Marked on studs with FS where required. 2). Right side between laundry room & Master bathroom: Missing Firestop along top plate of pack out walls as required. (FBC-302.11 (UL723)) 3). Left side Guest Bathropom at Bathtub fixture wall: Missing Firestop along top plate of pack out walls as required. (FBC-302.11 (UL723)) Inspector Notes from Inspection 2420 1/17/24: Walked with Superintendent. Check at Insulation. 1). Dryer duct needs to be sealed properly at all fittings, replace fabric straps with metal straps & seal duct at roof deck. 2). Wires for Range, AHU and Condensing unit need to be phased out in panel.
INSULATION 01/25/2024 Disapproved -FEE REQUIRED RSIMS
Note: 1/25/24: 1). Missing Firestop at Horizontal wire runs over 10ft. Per FBC 302.11: Required Locations (1.2. Horizontally at intervals not exceeding 10 feet (3048 mm)). Marked on studs with FS where required. 2). Right side between laundry room & Master bathroom: Missing Firestop along top plate of pack out walls as required. (FBC-302.11 (UL723)) 3). Left side Guest Bathropom at Bathtub fixture wall: Missing Firestop along top plate of pack out walls as required. (FBC-302.11 (UL723)) Inspector Notes from Inspection 2420 1/17/24: Walked with Superintendent. Check at Insulation. 1). Dryer duct needs to be sealed properly at all fittings, replace fabric straps with metal straps & seal duct at roof deck. 2). Wires for Range, AHU and Condensing unit need to be phased out in panel.
LATH/BRICK/ WATER BARRIER 01/25/2024 Disapproved - NO FEE RSIMS
Note: 1/25/24: 1). Need wire lath installed at all holes in cinderblock for romex & low voltage wiring. Inspector Notes from Inspection 2420 1/17/24: Walked with Superintendent. Check at Insulation. 1). Dryer duct needs to be sealed properly at all fittings, replace fabric straps with metal straps & seal duct at roof deck. 2). Wires for Range, AHU and Condensing unit need to be phased out in panel.
ALL ROUGH 01/17/2024 APPROVED - AS NOTED RSIMS
Note: 1/17/24: Walked with Superintendent. Check at Insulation. 1). Dryer duct needs to be sealed properly at all fittings, replace fabric straps with metal straps & seal duct at roof deck. 2). Wires for Range, AHU and Condensing unit need to be phased out in panel.
ROOF VALLEY & METAL 01/10/2024 APPROVED RSIMS
ROW - DRAINAGE 12/20/2023 APPROVED PFLANAGAN
Note: CORRECTION MADE 12/19/2023 - PREVIOUS INSPECTION NOTES STILL NEED TO PUT SILT FENCE ROUND RIGHT OF WAY --------------------------------------------------------------------------- 12/15/2023 - PREVIOUS INSPECTION NOTES AT THIS TIME OF THE INSPECTION THE SWALE IS CLOGED UP AGAIN AT THE TEMP. CULVERT. NEED TO OPEN SWALE AGAIN IT'S YOUR RESPONSIBILITY FOR YOU EVERY 7DAYS AND EVERY 1/2" OF RAIN TO CHECK ALL SEDIMENT DEVICES AND SWALE FROM ANY SEDIMENT. SINCE THE SWALE KEEPS FILLING UP WITH SEDIMENT YOU NEED TO PUT SILT FENCE AT THE RIGHT OF WAY LINE SO SEDIMENT STAYS OUT OF THE SWALE. NEED TO LEAVE AN ENTRANCE SO YOU CAN GAIN ACCESS TO YOUR LOT. ---------------------------------------------------------------------------------- 11/28/2023 - PREVIOUS INSPECTION NOTES 11/28/23 ROOF TRUSS REMOVED. PLEASE READ AND FOLLOW INSPECTORS PREVIOUS NOTES. CONCRETE SLAG AND PORTA POTTY STILL IN SWALE, NEED TO BE REMOVED. ________________________________________________________________________________________________________________________ 11/27/2023 - PREVIOUS INSPECTION NOTES 11/27/23 YOU NEED TO READ AND FOLLOW INSPECTORS NOTES. NO CORRECTIONS HAVE BEEN MADE. TRUSS IN SWALE. PORTA POTTY IN SWALE CONCRETE SLAG CLEAN OUT IN SWALE. AN INSPECTION HOLD WILL BE PLACED ON THIS PERMIT. 11/21/2023 - PREVIOUS INSPECTION NOTES 11/21/23 TRUSS STILL IN SWALE. PORTA POTTY IN SWALE. WILL BE BACK FOR REINSPECTION ON 11/27/23 IF CORRECTIONS ARE NOT MADE A STOP WORK ORDER MAY BE ISSUED. SEE PHOTO FOR REFERENCE. ___________________________________________________________________________________________________________________________ 11/16/2023 - PREVIOUS INSPECTION NOTES NEED TO OPEN THE SWALE, NEED TO REMOVE ALL THE TRUSS FROM THE SWALE PICTURE ATTACHED INSPECTOR BE BACK 11/21/23=
ROW - DRAINAGE 12/18/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: STILL NEED TO PUT SILT FENCE ROUND RIGHT OF WAY --------------------------------------------------------------------------- 12/15/2023 - PREVIOUS INSPECTION NOTES AT THIS TIME OF THE INSPECTION THE SWALE IS CLOGED UP AGAIN AT THE TEMP. CULVERT. NEED TO OPEN SWALE AGAIN IT'S YOUR RESPONSIBILITY FOR YOU EVERY 7DAYS AND EVERY 1/2" OF RAIN TO CHECK ALL SEDIMENT DEVICES AND SWALE FROM ANY SEDIMENT. SINCE THE SWALE KEEPS FILLING UP WITH SEDIMENT YOU NEED TO PUT SILT FENCE AT THE RIGHT OF WAY LINE SO SEDIMENT STAYS OUT OF THE SWALE. NEED TO LEAVE AN ENTRANCE SO YOU CAN GAIN ACCESS TO YOUR LOT. ---------------------------------------------------------------------------------- 11/28/2023 - PREVIOUS INSPECTION NOTES 11/28/23 ROOF TRUSS REMOVED. PLEASE READ AND FOLLOW INSPECTORS PREVIOUS NOTES. CONCRETE SLAG AND PORTA POTTY STILL IN SWALE, NEED TO BE REMOVED. ________________________________________________________________________________________________________________________ 11/27/2023 - PREVIOUS INSPECTION NOTES 11/27/23 YOU NEED TO READ AND FOLLOW INSPECTORS NOTES. NO CORRECTIONS HAVE BEEN MADE. TRUSS IN SWALE. PORTA POTTY IN SWALE CONCRETE SLAG CLEAN OUT IN SWALE. AN INSPECTION HOLD WILL BE PLACED ON THIS PERMIT. 11/21/2023 - PREVIOUS INSPECTION NOTES 11/21/23 TRUSS STILL IN SWALE. PORTA POTTY IN SWALE. WILL BE BACK FOR REINSPECTION ON 11/27/23 IF CORRECTIONS ARE NOT MADE A STOP WORK ORDER MAY BE ISSUED. SEE PHOTO FOR REFERENCE. ___________________________________________________________________________________________________________________________ 11/16/2023 - PREVIOUS INSPECTION NOTES NEED TO OPEN THE SWALE, NEED TO REMOVE ALL THE TRUSS FROM THE SWALE PICTURE ATTACHED INSPECTOR BE BACK 11/21/23=
ROW - DRAINAGE 12/15/2023 Disapproved -FEE REQUIRED PFLANAGAN
Note: AT THIS TIME OF THE INSPECTION THE SWALE IS CLOGED UP AGAIN AT THE TEMP. CULVERT. NEED TO OPEN SWALE AGAIN IT'S YOUR RESPONSIBILITY FOR YOU EVERY 7DAYS AND EVERY 1/2" OF RAIN TO CHECK ALL SEDIMENT DEVICES AND SWALE FROM ANY SEDIMENT. SINCE THE SWALE KEEPS FILLING UP WITH SEDIMENT YOU NEED TO PUT SILT FENCE AT THE RIGHT OF WAY LINE SO SEDIMENT STAYS OUT OF THE SWALE. NEED TO LEAVE AN ENTRANCE SO YOU CAN GAIN ACCESS TO YOUR LOT. ---------------------------------------------------------------------------------- 11/28/2023 - PREVIOUS INSPECTION NOTES 11/28/23 ROOF TRUSS REMOVED. PLEASE READ AND FOLLOW INSPECTORS PREVIOUS NOTES. CONCRETE SLAG AND PORTA POTTY STILL IN SWALE, NEED TO BE REMOVED. ________________________________________________________________________________________________________________________ 11/27/2023 - PREVIOUS INSPECTION NOTES 11/27/23 YOU NEED TO READ AND FOLLOW INSPECTORS NOTES. NO CORRECTIONS HAVE BEEN MADE. TRUSS IN SWALE. PORTA POTTY IN SWALE CONCRETE SLAG CLEAN OUT IN SWALE. AN INSPECTION HOLD WILL BE PLACED ON THIS PERMIT. 11/21/2023 - PREVIOUS INSPECTION NOTES 11/21/23 TRUSS STILL IN SWALE. PORTA POTTY IN SWALE. WILL BE BACK FOR REINSPECTION ON 11/27/23 IF CORRECTIONS ARE NOT MADE A STOP WORK ORDER MAY BE ISSUED. SEE PHOTO FOR REFERENCE. ___________________________________________________________________________________________________________________________ 11/16/2023 - PREVIOUS INSPECTION NOTES NEED TO OPEN THE SWALE, NEED TO REMOVE ALL THE TRUSS FROM THE SWALE PICTURE ATTACHED INSPECTOR BE BACK 11/21/23=
WALL SHEATHING 12/15/2023 APPROVED KSANDOE
ROOF SHEATHING / BRACES/TIES/DOWN CELL 12/15/2023 APPROVED - AS NOTED KSANDOE
Note: Missing nailing on H5 over entry
FOUND SURVEY APPROVED (OFFICE) 12/14/2023 APPROVED TBAKER
ROW - DRAINAGE 11/28/2023 Disapproved -FEE REQUIRED FSLADISH
Note: 11/28/23 ROOF TRUSS REMOVED. PLEASE READ AND FOLLOW INSPECTORS PREVIOUS NOTES. CONCRETE SLAG AND PORTA POTTY STILL IN SWALE, NEED TO BE REMOVED. ________________________________________________________________________________________________________________________ 11/27/2023 - PREVIOUS INSPECTION NOTES 11/27/23 YOU NEED TO READ AND FOLLOW INSPECTORS NOTES. NO CORRECTIONS HAVE BEEN MADE. TRUSS IN SWALE. PORTA POTTY IN SWALE CONCRETE SLAG CLEAN OUT IN SWALE. AN INSPECTION HOLD WILL BE PLACED ON THIS PERMIT. 11/21/2023 - PREVIOUS INSPECTION NOTES 11/21/23 TRUSS STILL IN SWALE. PORTA POTTY IN SWALE. WILL BE BACK FOR REINSPECTION ON 11/27/23 IF CORRECTIONS ARE NOT MADE A STOP WORK ORDER MAY BE ISSUED. SEE PHOTO FOR REFERENCE. ___________________________________________________________________________________________________________________________ 11/16/2023 - PREVIOUS INSPECTION NOTES NEED TO OPEN THE SWALE, NEED TO REMOVE ALL THE TRUSS FROM THE SWALE PICTURE ATTACHED INSPECTOR BE BACK 11/21/23=
ROW - DRAINAGE 11/27/2023 Disapproved -FEE REQUIRED FSLADISH
Note: 11/27/23 YOU NEED TO READ AND FOLLOW INSPECTORS NOTES. NO CORRECTIONS HAVE BEEN MADE. TRUSS IN SWALE. PORTA POTTY IN SWALE CONCRETE SLAG CLEAN OUT IN SWALE. AN INSPECTION HOLD WILL BE PLACED ON THIS PERMIT. 11/21/2023 - PREVIOUS INSPECTION NOTES 11/21/23 TRUSS STILL IN SWALE. PORTA POTTY IN SWALE. WILL BE BACK FOR REINSPECTION ON 11/27/23 IF CORRECTIONS ARE NOT MADE A STOP WORK ORDER MAY BE ISSUED. SEE PHOTO FOR REFERENCE. ___________________________________________________________________________________________________________________________ 11/16/2023 - PREVIOUS INSPECTION NOTES NEED TO OPEN THE SWALE, NEED TO REMOVE ALL THE TRUSS FROM THE SWALE PICTURE ATTACHED INSPECTOR BE BACK 11/21/23=
ROW - DRAINAGE 11/21/2023 Disapproved -FEE REQUIRED FSLADISH
Note: 11/21/23 TRUSS STILL IN SWALE. PORTA POTTY IN SWALE. WILL BE BACK FOR REINSPECTION ON 11/27/23 IF CORRECTIONS ARE NOT MADE A STOP WORK ORDER MAY BE ISSUED. SEE PHOTO FOR REFERENCE. ___________________________________________________________________________________________________________________________ 11/16/2023 - PREVIOUS INSPECTION NOTES NEED TO OPEN THE SWALE, NEED TO REMOVE ALL THE TRUSS FROM THE SWALE PICTURE ATTACHED INSPECTOR BE BACK 11/21/23=
ROW - DRAINAGE 11/16/2023 Disapproved - NO FEE GBERTOLA
Note: NEED TO OPEN THE SWALE, NEED TO REMOVE ALL THE TRUSS FROM THE SWALE PICTURE ATTACHED INSPECTOR BE BACK 11/21/23=
TIE BEAM / LINTEL 10/31/2023 APPROVED RSIMS
Note: 10/30/2023 - PREVIOUS INSPECTION NOTES 10/30/23: Marked on plans * Missing tie at down rod to dowel on left back wall of garage. * Missing tie wire at down rod to lintel bar on top right side of garage entry. Please cleanup pile of trash at front & put in dumpster before next inspection. Also, need address on permit box or building.
TIE BEAM / LINTEL 10/30/2023 Disapproved - NO FEE RSIMS
Note: 10/30/23: Marked on plans * Missing tie at down rod to dowel on left back wall of garage. * Missing tie wire at down rod to lintel bar on top right side of garage entry. Please cleanup pile of trash at front & put in dumpster before next inspection. Also, need address on permit box or building.
MONOLITHIC SLAB 10/23/2023 APPROVED BTAYLOR
Note: 10/20/2023 - PREVIOUS INSPECTION NOTES 10/20/23: Cancelled by Applicant via phone call at @ 09:53.
MONOLITHIC SLAB 10/20/2023 CANCELLED BY APPLICANT RSIMS
Note: 10/20/23: Cancelled by Applicant via phone call at @ 09:53.
PLUMBING 1ST ROUGH UNDERGROUND 10/17/2023 APPROVED MGIBSON
WATER METER INSTALLATION REQUEST 10/05/2023 APPROVED CBOWERMASTER

Review History

Department Status Date In Date Out
MECH COMPLETE 03/27/2024 04/02/2024
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ELEC COMPLETE 01/09/2024 01/11/2024
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ELEC COMPLETE 12/18/2023 12/22/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/13/2023 12/13/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 12/13/2023 12/13/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
ENGIN1 COMPLETE 12/06/2023 12/06/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
SW1 COMPLETE 12/06/2023 12/12/2023
Note: Released By: JOHN HOWARD - - JHOWARD@PALMCOASTGOV.COM
ZON COMPLETE 12/06/2023 12/06/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
ZON COMPLETE 11/29/2023 11/29/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SWALE COMPLETE 09/08/2023 10/26/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
BLD COMPLETE 09/07/2023 09/10/2023
Note: Released By: JPI
CUSVC COMPLETE 09/07/2023 09/11/2023
Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM
ELEC COMPLETE 09/07/2023 09/11/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
ENGIN1 COMPLETE 09/07/2023 09/08/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
GAS CANCEL 09/07/2023 09/11/2023
LOCATE COMPLETE 09/07/2023 09/12/2023
Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM
MECH COMPLETE 09/07/2023 09/12/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 09/07/2023 09/08/2023
Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM
ZON COMPLETE 09/07/2023 09/08/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM
BADMIN COMPLETE 09/07/2023 09/11/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
CONTRACTOR CHANGE ¤40.00 05/21/2024
SW ENG - INSPECTION 20 ¤20.00 05/21/2024
SW ENG - INSPECTION 20 ¤20.00 05/21/2024
SW ENG - INSPECTION 20 ¤20.00 05/21/2024
SW ENG - INSPECTION 20 ¤20.00 05/21/2024
SW ENG - INSPECTION 20 ¤20.00 05/21/2024
SW ENG - INSPECTION 20 ¤20.00 05/21/2024
SW ENG - INSPECTION 20 ¤20.00 05/21/2024
SW ENG REINSPECTION 20 ¤20.00 05/21/2024
SW ENG REINSPECTION 30 ¤30.00 05/21/2024
SW ENG REINSPECTION 30 ¤30.00 05/21/2024
SW ENG REINSPECTION 30 ¤30.00 05/21/2024
SW ENG REINSPECTION 30 ¤30.00 05/21/2024
SW ENG REINSPECTION 30 ¤30.00 05/21/2024
REINSPECTION RESIDENTIAL ¤40.00 05/21/2024
CONNECTION FEES ¤1,166.26 09/12/2023
WATER-METER ¤505.39 09/12/2023
WATER- TURN ON ¤25.00 09/12/2023
WATER- TURN ON ¤25.00 09/12/2023
ADJUSTMENT 50% (¤514.50) 09/12/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 09/12/2023
INSPECTION - RESIDENTIAL ¤778.25 09/12/2023
PLAN REVIEW - RESIDENTIAL ¤220.74 09/12/2023
SW ENG - REVIEW 20 ¤20.00 09/12/2023
SW ENG RES REVIEW 200 ¤200.00 09/12/2023
TRANS IMPACT FEE ADMIN ¤54.36 09/12/2023
TRANS IMPACT FEE ADMIN (¤54.36) 09/12/2023
SEWER CREDIT (¤1,466.00) 09/12/2023
SEWER INSPECTION ¤25.00 09/12/2023
SEWER CAPITAL FACILITY ¤5,344.82 09/12/2023
WATER CAPITAL FACILITY FEE ¤3,923.88 09/12/2023
SITE PLAN 30 ¤30.00 09/12/2023
SW ENG INSPECTION 80 ¤80.00 09/12/2023
SW ENG PRE APRON ¤30.00 09/12/2023
FIRE IMPACT FEE ADMIN ¤12.62 09/12/2023
FIRE IMPACT FEE ADMIN (¤12.62) 09/12/2023
FC IMPACT FEE EMS ¤62.00 09/12/2023
IMPACT FEE FIRE ¤420.52 09/12/2023
FC IMPACT FEE LAW ENFORCEMENT ¤218.00 09/12/2023
FC IMPACT FEE LIBRARY ¤268.00 09/12/2023
IMPACT FEE PARKS ¤1,769.15 09/12/2023
IMPACT FEE SCHOOL ¤5,450.00 09/12/2023
IMPACT FEE TRANSPORTATION ¤1,812.00 09/12/2023
WATER -IRRIGATION INSPECTION ¤25.00 09/12/2023
WATER -IRRIGATION INSPECTION ¤25.00 09/12/2023
PARKS IMPACT FEE ADMIN ¤53.07 09/12/2023
PARKS IMPACT FEE ADMIN (¤53.07) 09/12/2023
SURCHARGE FS 533.721 ¤5.14 09/12/2023
SURCHARGE - FS 468.631 ¤7.72 09/12/2023
SW ENG - FOUNDATION SURVEY ¤20.00 09/12/2023
Fees Total Due: ¤0.00 Total Paid: ¤20,896.37