I want to search for...
Permit #2023090646
Permit Details
Status: COED
| Parcel Id: 07-11-31-7032-00380-0170 |
| CONDITIONED SPACE: 1500 sqft |
| GARAGE: 396 sqft |
| OPENED PORCH (WITH ROOF) : 119 sqft |
| Total Square Footage: 2015 sqft |
| Block: 00380 |
| Subdivision: 2155 - SECTION 32-ROYAL PALMS |
| Job Phone: 202-494-2019 |
| Location Address: 9 RUSSKIN LN |
| Type: BR - BUILDING RESIDENTIAL -SINGLE FAMILY |
| Issue Date: 10/02/2023 |
| NOC: RECORDED |
| Applicant name: GARY ANDREW FISCHER |
| Owner: INB FUND 2 LLC |
|
Address 3670 MAGUIRE BOULEVARD SUITE 220 ORLANDO, FL 32803 |
| Lot: 0170 |
| Contracted Stated Job Value: ¤150,000.00 |
| Job Description: SINGLE FAMILY RESIDENCE |
| Type: CN |
Contractor
INB HOMES
| Status | Location Address | Mailing Address | State License Number | Phone |
| ACTIVE |
3670 MAGUIRE BLVD ORLANDO, FL 32803 |
SUITE 210 ORLANDO, FL 32803 |
CGC048746 (Exp: 08/31/2026) | 407-476-8195 |
Sub Contractors
JOSEPH HORATIO STRADA JR
| Status | Location Address | State License Number | Phone |
| ACTIVE |
3400 ST JOHNS PARKWAY SANFORD, FL 32771 |
EC13003715 (Exp: 08/31/2026) | 877-906-1113 |
ROBERT MICHAEL RENNER
| Status | Location Address | State License Number | Phone |
| ACTIVE |
531 CODISCO WAY SANFORD, FL 32771 |
CAC051477 (Exp: 08/31/2026) | 407-333-2665 |
TERRY BRICE DICKERSON
| Status | Location Address | State License Number | Phone |
| ACTIVE |
4300 ST JOHN'S PARKWAY ALPHARETTA, GA 30009 |
CCC1326209 (Exp: 08/31/2026) | 407-548-6733 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone |
| ACTIVE |
126 EAST END RD SAN MATEO, FL 32187 |
CFC1429896 (Exp: 08/31/2026) | 386-871-8823 |
Inspection History
| Type | Request Date | Result | Inspector |
| BLD - BUILDING FINAL | 05/09/2024 | FINAL APPROVED | AGAETANO |
| Note: 5/8/2024 - PREVIOUS INSPECTION NOTES 5/7/2024 - PREVIOUS INSPECTION NOTES 5/6/2024 - PREVIOUS INSPECTION NOTES 5/3/2024 - PREVIOUS INSPECTION NOTES 05-06-2024 Doors locked. Need access for inspection. 05-07-2024 1. Garage walls not sealed. 2. Kitchen supply not installed at ceiling. 3. Heat label not indicated at AHU. 4. Seal AHU duct at ceiling. 5.Anti tilt. Not ready. A complete inspection is required for final inspection. 05-08-2024 Above issue has not been resolved. Garage walls not sealed.• Garage penetrations sealed FBC R302.6 | |||
| BLD - BUILDING FINAL | 05/08/2024 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 5/7/2024 - PREVIOUS INSPECTION NOTES 5/6/2024 - PREVIOUS INSPECTION NOTES 5/3/2024 - PREVIOUS INSPECTION NOTES 05-06-2024 Doors locked. Need access for inspection. 05-07-2024 1. Garage walls not sealed. 2. Kitchen supply not installed at ceiling. 3. Heat label not indicated at AHU. 4. Seal AHU duct at ceiling. 5.Anti tilt. Not ready. A complete inspection is required for final inspection. 05-08-2024 Above issue has not been resolved. Garage walls not sealed.• Garage penetrations sealed FBC R302.6 | |||
| BLD - BUILDING FINAL | 05/07/2024 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 5/6/2024 - PREVIOUS INSPECTION NOTES 5/3/2024 - PREVIOUS INSPECTION NOTES 05-06-2024 Doors locked. Need access for inspection. 05-07-2024 1. Garage walls not sealed. 2. Kitchen supply not installed at ceiling. 3. Heat label not indicated at AHU. 4. Seal AHU duct at ceiling. 5.Anti tilt. Not ready. A complete inspection is required for final inspection. | |||
| BLD - BUILDING FINAL | 05/06/2024 | Disapproved -FEE REQUIRED | AGAETANO |
| Note: 5/3/2024 - PREVIOUS INSPECTION NOTES 05-06-2024 Doors locked. Need access for inspection. | |||
| ROW - FINAL APRON (AFTER POUR) | 05/06/2024 | APPROVED | TPOLACEK |
| Note: *** NOTES ADDED BY TPOLACEK 5/6/2024 1:01:28 PM *** PIPE IS GOOD, CUTS ARE MADE, CULVERT CLEAR, HOT PATCH COMPLETE. AT THE TIME OF THE INSPECTION ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED 5/3/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY TPOLACEK 5/3/2024 9:37:46 AM *** Pipe is full of sediment and needs to be cleaned out. Large chip on right side should be repaired Inspector Notes from Inspection 9465 05/02/24 ALTHOUGH IT WILL WORK AS INDICATED ON FINAL SURVEY I BELIEVE IT WOULD HAVE BEEN MORE BENIFICIAL TO CREATE A COMMON SWALE ON THE LEFT SIDE FROM THE FENCE FORWARD. THE FFE ON BOTH HOMES IS HIGH ENOUGH TO HAVE ACCOMPLISHED A COMMON SWALE WITHOUT THE USE OF THE BERM. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - STORMWATER FINAL | 05/06/2024 | APPROVED | TPOLACEK |
| Note: *** NOTES ADDED BY TPOLACEK 5/6/2024 1:02:06 PM *** AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED. 5/3/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY TPOLACEK 5/3/2024 9:38:31 AM *** Trash around yard needs to be cleaned up before row will be approved Inspector Notes from Inspection 9465 05/02/24 ALTHOUGH IT WILL WORK AS INDICATED ON FINAL SURVEY I BELIEVE IT WOULD HAVE BEEN MORE BENIFICIAL TO CREATE A COMMON SWALE ON THE LEFT SIDE FROM THE FENCE FORWARD. THE FFE ON BOTH HOMES IS HIGH ENOUGH TO HAVE ACCOMPLISHED A COMMON SWALE WITHOUT THE USE OF THE BERM. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U -UTILITY RESIDENTIAL FINAL | 05/03/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 5/3/2024 1:09:59 PM *** raise sewer C/O so not covered over by growing sod(make flush)-pic to me when completed | |||
| ROW - STORMWATER FINAL | 05/03/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: *** NOTES ADDED BY TPOLACEK 5/3/2024 9:38:31 AM *** Trash around yard needs to be cleaned up before row will be approved Inspector Notes from Inspection 9465 05/02/24 ALTHOUGH IT WILL WORK AS INDICATED ON FINAL SURVEY I BELIEVE IT WOULD HAVE BEEN MORE BENIFICIAL TO CREATE A COMMON SWALE ON THE LEFT SIDE FROM THE FENCE FORWARD. THE FFE ON BOTH HOMES IS HIGH ENOUGH TO HAVE ACCOMPLISHED A COMMON SWALE WITHOUT THE USE OF THE BERM. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW - FINAL APRON (AFTER POUR) | 05/03/2024 | Disapproved - NO FEE | TPOLACEK |
| Note: *** NOTES ADDED BY TPOLACEK 5/3/2024 9:37:46 AM *** Pipe is full of sediment and needs to be cleaned out. Large chip on right side should be repaired Inspector Notes from Inspection 9465 05/02/24 ALTHOUGH IT WILL WORK AS INDICATED ON FINAL SURVEY I BELIEVE IT WOULD HAVE BEEN MORE BENIFICIAL TO CREATE A COMMON SWALE ON THE LEFT SIDE FROM THE FENCE FORWARD. THE FFE ON BOTH HOMES IS HIGH ENOUGH TO HAVE ACCOMPLISHED A COMMON SWALE WITHOUT THE USE OF THE BERM. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| U-CROSS CONNECTION | 05/03/2024 | APPROVED - AS NOTED | LFITZGERALD |
| Note: *** NOTES ADDED BY LFITZGERALD 5/3/2024 1:09:00 PM *** no irr-no cross connection | |||
| BLD - BUILDING FINAL | 05/03/2024 | CANCELLED BY APPLICANT | AGAETANO |
| ROW- FINAL SURVEY/GRADING CERTIFICATION | 05/02/2024 | APPROVED | TPOLACEK |
| Note: 05/02/24 --------------------------------------------------------------------------------------- Inspector Notes from Inspection 9270 ** 04/10/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| ROW FIELD SURVEY /GRADING CERTIFICATION | 05/02/2024 | APPROVED - AS NOTED | TPOLACEK |
| Note: 05/02/24 ALTHOUGH IT WILL WORK AS INDICATED ON FINAL SURVEY I BELIEVE IT WOULD HAVE BEEN MORE BENIFICIAL TO CREATE A COMMON SWALE ON THE LEFT SIDE FROM THE FENCE FORWARD. THE FFE ON BOTH HOMES IS HIGH ENOUGH TO HAVE ACCOMPLISHED A COMMON SWALE WITHOUT THE USE OF THE BERM. AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. NIETHER THE INSPECTOR NOR THE CITY IS RESPONSIBLE IF, FOR WHATEVER REASON, SITE CONDITIONS CHANGE OVER TIME AFTER THE INSPECTION. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED | |||
| ROW- PRE-APRON (PRE-POUR) | 04/10/2024 | APPROVED - AS NOTED | EMADISON |
| Note: ** 04/10/24 READY TO POUR ** At the time of the inspection all minimum city requirements were met. It is the builders responsibility to ensure that nothing changes after this Inspection is approved. This includes but is not limited to, the Culvert Pipe Elevation from the time of the inspection approval to the concrete pour. **MAKE SURE THERE IS 3000 PSI CONCRETE REINFORCED WITH WWF 6X6.W1.4 MESH OR FIBERGLASS REINFORCED CONCRETE (FRC) DRAWING 300,E RESIDENTIAL CULVERT DETAIL | |||
| ELECTRIC - EARLY POWER | 04/04/2024 | APPROVED | RMARTIN |
| GRAVITY SEWER TEST | 03/06/2024 | APPROVED | MGIBSON |
| U - SEWER TIE IN | 03/06/2024 | APPROVED | MGIBSON |
| INSULATION | 02/16/2024 | APPROVED | JWALKER |
| Note: 2/15/2024 - PREVIOUS INSPECTION NOTES 2/15/24 Item 1 dryer duct mechanical joint are to be sealed. 2/13/2024 - PREVIOUS INSPECTION NOTES 2/13/24 1. Depth gauges for the blowin insulation in the attic space have not been installed. 2. Item 1 listed below has not been corrected. 2/9/24 1. Dryer duct has not been seal at the mechanical joints. 2. Approved duct layout needs to be onsite Check for listed corrections above at the insulation inspection. 2/1/2024 - PREVIOUS INSPECTION NOTES 2/1/24 1. The dryer duct mechanical joints have not been sealed. 2. Water distribution piping is not under test. 3. Please have the approved duct layout onsite at reinspection 4. The item listed below from the previous inspection has not been corrected. Support and anchor the ridge beam. Inspector Notes from Inspection 2460 1/22/24 Item 2 listed below has not been corrected check for correction at the ALL Rough inspection. 2. The over framing ridge beam at the rear porch needs to be supported below and anhcored. . | |||
| INSULATION | 02/15/2024 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 2/15/24 Item 1 dryer duct mechanical joint are to be sealed. 2/13/2024 - PREVIOUS INSPECTION NOTES 2/13/24 1. Depth gauges for the blowin insulation in the attic space have not been installed. 2. Item 1 listed below has not been corrected. 2/9/24 1. Dryer duct has not been seal at the mechanical joints. 2. Approved duct layout needs to be onsite Check for listed corrections above at the insulation inspection. 2/1/2024 - PREVIOUS INSPECTION NOTES 2/1/24 1. The dryer duct mechanical joints have not been sealed. 2. Water distribution piping is not under test. 3. Please have the approved duct layout onsite at reinspection 4. The item listed below from the previous inspection has not been corrected. Support and anchor the ridge beam. Inspector Notes from Inspection 2460 1/22/24 Item 2 listed below has not been corrected check for correction at the ALL Rough inspection. 2. The over framing ridge beam at the rear porch needs to be supported below and anhcored. . | |||
| INSULATION | 02/13/2024 | Disapproved - NO FEE | JWALKER |
| Note: 2/13/24 1. Depth gauges for the blowin insulation in the attic space have not been installed. 2. Item 1 listed below has not been corrected. 2/9/24 1. Dryer duct has not been seal at the mechanical joints. 2. Approved duct layout needs to be onsite Check for listed corrections above at the insulation inspection. 2/1/2024 - PREVIOUS INSPECTION NOTES 2/1/24 1. The dryer duct mechanical joints have not been sealed. 2. Water distribution piping is not under test. 3. Please have the approved duct layout onsite at reinspection 4. The item listed below from the previous inspection has not been corrected. Support and anchor the ridge beam. Inspector Notes from Inspection 2460 1/22/24 Item 2 listed below has not been corrected check for correction at the ALL Rough inspection. 2. The over framing ridge beam at the rear porch needs to be supported below and anhcored. . | |||
| ALL ROUGH | 02/09/2024 | APPROVED - AS NOTED | JWALKER |
| Note: 2/9/24 1. Dryer duct has not been seal at the mechanical joints. 2. Approved duct layout needs to be onsite Check for listed corrections above at the insulation inspection. 2/1/2024 - PREVIOUS INSPECTION NOTES 2/1/24 1. The dryer duct mechanical joints have not been sealed. 2. Water distribution piping is not under test. 3. Please have the approved duct layout onsite at reinspection 4. The item listed below from the previous inspection has not been corrected. Support and anchor the ridge beam. Inspector Notes from Inspection 2460 1/22/24 Item 2 listed below has not been corrected check for correction at the ALL Rough inspection. 2. The over framing ridge beam at the rear porch needs to be supported below and anhcored. . | |||
| LATH/BRICK/ WATER BARRIER | 02/02/2024 | APPROVED | JWALKER |
| ALL ROUGH | 02/01/2024 | Disapproved - NO FEE | JWALKER |
| Note: 2/1/24 1. The dryer duct mechanical joints have not been sealed. 2. Water distribution piping is not under test. 3. Please have the approved duct layout onsite at reinspection 4. The item listed below from the previous inspection has not been corrected. Support and anchor the ridge beam. Inspector Notes from Inspection 2460 1/22/24 Item 2 listed below has not been corrected check for correction at the ALL Rough inspection. 2. The over framing ridge beam at the rear porch needs to be supported below and anhcored. . | |||
| ROW - DRAINAGE | 01/26/2024 | APPROVED | PFLANAGAN |
| Note: CORRECTIONS FIXED ------------------------------------------------------------------------- 1/25/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO RE-ESTABLISH SILT FENCE AROUND PROPERTY YOU HAVE HAD OF TIME TO FIX ALL AREAS THERE IS NOW A INSPECTION HOLD ON THIS CONSTRUCTION SITE ---------------------------------------------------------------------------------------- 1/24/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO RE-ESTABLISH SILT FENCE AROUND PROPERTY LINE --------------------------------------------------------------------------------------- 1/17/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAR ALL DIRT AND SEDIMENT IN THE ROADSIDE SWALE AND IN FRONT OF TEMP. CULVERT SO WATER WILL TO OUTFALL. 2) NEED TO PICK ALL TRASH IN THE CONSTRUCTION SITE 3) NEED TO RE-ESTABLISH SILT FENCE AROUND THE PROPERTY AND AT THE FRONT PROPERTY LINE AND LEAVE A ENTRANCE TO YOUR LOT. THIS WILL PROVENT AND MORE SEDIMENT GOING INTO ROADSIDE SWALE AND KEEP THE FLOW OPEN AT ALL TIMES OF THE CONSTRUCTION. 4) IT IS YOUR RESPONSIBILITY TO CHECK ALL YOUR SEMIDENT CONTROL DEVICES EVERY 7 BUSINESS DAYS OR EVERY 1/2" OF RAIN THIS IS REQUIRED BY STATE LAW AND COMES WITH BIG FINES IF NO ACTIONS ARE DONE. YOU WILL HAV 7 DAYS TO FIX ALL AREAS LISTED ABOVE OR THERE WILL BE A INSPECTION HOLD ON THIS CONSTRUCTION SITE. NEXT INSPECTION 1/24/24 ----------------------------------------------------------------------------------------------------------------- CITIZEN AT 9 RUSSKIN SAYS THAT NEW CONSTUCTION IS PREVENTING DRAINAGE & ALGAE IS GROWING. MH | |||
| ROW - DRAINAGE | 01/25/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: STILL NEED TO RE-ESTABLISH SILT FENCE AROUND PROPERTY YOU HAVE HAD OF TIME TO FIX ALL AREAS THERE IS NOW A INSPECTION HOLD ON THIS CONSTRUCTION SITE ---------------------------------------------------------------------------------------- 1/24/2024 - PREVIOUS INSPECTION NOTES STILL NEED TO RE-ESTABLISH SILT FENCE AROUND PROPERTY LINE --------------------------------------------------------------------------------------- 1/17/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAR ALL DIRT AND SEDIMENT IN THE ROADSIDE SWALE AND IN FRONT OF TEMP. CULVERT SO WATER WILL TO OUTFALL. 2) NEED TO PICK ALL TRASH IN THE CONSTRUCTION SITE 3) NEED TO RE-ESTABLISH SILT FENCE AROUND THE PROPERTY AND AT THE FRONT PROPERTY LINE AND LEAVE A ENTRANCE TO YOUR LOT. THIS WILL PROVENT AND MORE SEDIMENT GOING INTO ROADSIDE SWALE AND KEEP THE FLOW OPEN AT ALL TIMES OF THE CONSTRUCTION. 4) IT IS YOUR RESPONSIBILITY TO CHECK ALL YOUR SEMIDENT CONTROL DEVICES EVERY 7 BUSINESS DAYS OR EVERY 1/2" OF RAIN THIS IS REQUIRED BY STATE LAW AND COMES WITH BIG FINES IF NO ACTIONS ARE DONE. YOU WILL HAV 7 DAYS TO FIX ALL AREAS LISTED ABOVE OR THERE WILL BE A INSPECTION HOLD ON THIS CONSTRUCTION SITE. NEXT INSPECTION 1/24/24 ----------------------------------------------------------------------------------------------------------------- CITIZEN AT 9 RUSSKIN SAYS THAT NEW CONSTUCTION IS PREVENTING DRAINAGE & ALGAE IS GROWING. MH | |||
| ROW - DRAINAGE | 01/24/2024 | Disapproved -FEE REQUIRED | PFLANAGAN |
| Note: STILL NEED TO RE-ESTABLISH SILT FENCE AROUND PROPERTY LINE --------------------------------------------------------------------------------------- 1/17/2024 - PREVIOUS INSPECTION NOTES 1) NEED TO CLEAR ALL DIRT AND SEDIMENT IN THE ROADSIDE SWALE AND IN FRONT OF TEMP. CULVERT SO WATER WILL TO OUTFALL. 2) NEED TO PICK ALL TRASH IN THE CONSTRUCTION SITE 3) NEED TO RE-ESTABLISH SILT FENCE AROUND THE PROPERTY AND AT THE FRONT PROPERTY LINE AND LEAVE A ENTRANCE TO YOUR LOT. THIS WILL PROVENT AND MORE SEDIMENT GOING INTO ROADSIDE SWALE AND KEEP THE FLOW OPEN AT ALL TIMES OF THE CONSTRUCTION. 4) IT IS YOUR RESPONSIBILITY TO CHECK ALL YOUR SEMIDENT CONTROL DEVICES EVERY 7 BUSINESS DAYS OR EVERY 1/2" OF RAIN THIS IS REQUIRED BY STATE LAW AND COMES WITH BIG FINES IF NO ACTIONS ARE DONE. YOU WILL HAV 7 DAYS TO FIX ALL AREAS LISTED ABOVE OR THERE WILL BE A INSPECTION HOLD ON THIS CONSTRUCTION SITE. NEXT INSPECTION 1/24/24 ----------------------------------------------------------------------------------------------------------------- CITIZEN AT 9 RUSSKIN SAYS THAT NEW CONSTUCTION IS PREVENTING DRAINAGE & ALGAE IS GROWING. MH | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/22/2024 | APPROVED - AS NOTED | JWALKER |
| Note: 1/22/24 Item 2 listed below has not been corrected check for correction at the ALL Rough inspection. 1/17/2024 - PREVIOUS INSPECTION NOTES 1. The H10A anchors at the rear porch and the beams are concealed with plywood. 2. The over framing ridge beam at the rear porch needs to be supported below and anhcored. 3. Front entry over framing. Hold down anchor is not nailed to truss below. 4. Trusses T-13, 14A, and 14 x2 are missing engineering. 5. Truss T01 right side of the building. Fornt and rear of the truss missing 1 of 2 required heta 20 anchors. | |||
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 01/17/2024 | Disapproved - NO FEE | JWALKER |
| Note: 1. The H10A anchors at the rear porch and the beams are concealed with plywood. 2. The over framing ridge beam at the rear porch needs to be supported below and anhcored. 3. Front entry over framing. Hold down anchor is not nailed to truss below. 4. Trusses T-13, 14A, and 14 x2 are missing engineering. 5. Truss T01 right side of the building. Fornt and rear of the truss missing 1 of 2 required heta 20 anchors. | |||
| ROOF VALLEY & METAL | 01/17/2024 | APPROVED | JWALKER |
| ELECTRIC-TUG | 01/16/2024 | APPROVED | JWALKER |
| ROW - DRAINAGE | 01/12/2024 | Disapproved - NO FEE | PFLANAGAN |
| Note: 1) NEED TO CLEAR ALL DIRT AND SEDIMENT IN THE ROADSIDE SWALE AND IN FRONT OF TEMP. CULVERT SO WATER WILL TO OUTFALL. 2) NEED TO PICK ALL TRASH IN THE CONSTRUCTION SITE 3) NEED TO RE-ESTABLISH SILT FENCE AROUND THE PROPERTY AND AT THE FRONT PROPERTY LINE AND LEAVE A ENTRANCE TO YOUR LOT. THIS WILL PROVENT AND MORE SEDIMENT GOING INTO ROADSIDE SWALE AND KEEP THE FLOW OPEN AT ALL TIMES OF THE CONSTRUCTION. 4) IT IS YOUR RESPONSIBILITY TO CHECK ALL YOUR SEMIDENT CONTROL DEVICES EVERY 7 BUSINESS DAYS OR EVERY 1/2" OF RAIN THIS IS REQUIRED BY STATE LAW AND COMES WITH BIG FINES IF NO ACTIONS ARE DONE. YOU WILL HAV 7 DAYS TO FIX ALL AREAS LISTED ABOVE OR THERE WILL BE A INSPECTION HOLD ON THIS CONSTRUCTION SITE. NEXT INSPECTION 1/24/24 ----------------------------------------------------------------------------------------------------------------- CITIZEN AT 9 RUSSKIN SAYS THAT NEW CONSTUCTION IS PREVENTING DRAINAGE & ALGAE IS GROWING. MH | |||
| ROOF SHEATHING | 01/10/2024 | APPROVED | JWALKER |
| WALL SHEATHING | 01/10/2024 | APPROVED | JWALKER |
| TIE BEAM / LINTEL | 12/27/2023 | APPROVED | JWALKER |
| Note: 12/22/2023 - PREVIOUS INSPECTION NOTES 1. Rear slider opening each side calls for (2) # 5 rebar to be installed. 2. The rear porch columns the vertical down rod rebar need to be centered and support to allow for proper concrete coverage. 12/21/2023 - PREVIOUS INSPECTION NOTES Prints are wet, torn and out of order. | |||
| TIE BEAM / LINTEL | 12/22/2023 | Disapproved -FEE REQUIRED | JWALKER |
| Note: 1. Rear slider opening each side calls for (2) # 5 rebar to be installed. 2. The rear porch columns the vertical down rod rebar need to be centered and support to allow for proper concrete coverage. 12/21/2023 - PREVIOUS INSPECTION NOTES Prints are wet, torn and out of order. | |||
| TIE BEAM / LINTEL | 12/21/2023 | Disapproved - NO FEE | JWALKER |
| Note: Prints are wet, torn and out of order. | |||
| FOUND SURVEY APPROVED (OFFICE) | 12/21/2023 | APPROVED | TBAKER |
| MONOLITHIC SLAB | 12/14/2023 | APPROVED | JWALKER |
| PLUMBING 1ST ROUGH UNDERGROUND | 12/11/2023 | APPROVED | MGIBSON |
| WATER METER INSTALLATION REQUEST | 11/14/2023 | APPROVED | BVITALE |
| Note: 11/7/2023 7:21:05 AM- PREVIOUS INSPECTION NOTES logs on property | |||
| WATER METER INSTALLATION REQUEST | 11/06/2023 | Disapproved -FEE REQUIRED | CBOWERMASTER |
| Note: logs on property |
Review History
| Department | Status | Date In | Date Out |
| BADMIN | INFORMATION | 04/30/2024 | 04/30/2024 |
| Note: Marked INFORMATION By: MICHELLE RAMOS - (386)986-3780 - MRAMOS@PALMCOASTGOV.COM Unable to process final survey because prior inspection needed. | |||
| MECH | COMPLETE | 04/24/2024 | 04/26/2024 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 01/24/2024 | 01/25/2024 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 12/21/2023 | 12/21/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 12/21/2023 | 12/21/2023 |
| Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 12/13/2023 | 12/13/2023 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Formboard survey is unacceptable as foundation survey. Please submit foundation survey showing location, dimensions and elevation of finished concrete foundation/slab. | |||
| ZON | HOLD | 12/13/2023 | 12/13/2023 |
| Note: Held By: TRACEY DOAK - (386)986-3751 - TDOAK@PALMCOASTGOV.COM Foundation survey must show the front setback from the closest point at front of home (the area by the entry that projects closer). | |||
| ZON | COMPLETE | 12/13/2023 | 12/13/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| ENGIN1 | HOLD | 12/13/2023 | 12/13/2023 |
| Note: Held By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM Formboard survey is unacceptable as foundation survey. Please submit foundation survey showing location, dimensions and elevation of finished concrete foundation/slab. | |||
| ENGIN1 | COMPLETE | 10/30/2023 | 10/30/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 10/30/2023 | 11/13/2023 |
| Note: Released By: JEFF CREWS - - JCREWS@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 10/30/2023 | 10/30/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 09/26/2023 | 09/26/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| SWALE | COMPLETE | 09/18/2023 | 11/02/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/15/2023 | 09/16/2023 |
| Note: Released By: JPI | |||
| CUSVC | COMPLETE | 09/15/2023 | 09/18/2023 |
| Note: Released By: HALEIGH HAND - - HHAND@PALMCOASTGOV.COM | |||
| ELEC | COMPLETE | 09/15/2023 | 09/15/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| ENGIN1 | COMPLETE | 09/15/2023 | 09/18/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| GAS | CANCEL | 09/15/2023 | 09/18/2023 |
| LOCATE | COMPLETE | 09/15/2023 | 09/18/2023 |
| Note: Released By: CANDACE BOWERMASTER - - CBOWERMASTER@PALMCOASTGOV.COM | |||
| MECH | HOLD | 09/15/2023 | 09/18/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM Design location on Energy calcs needs to be Daytona Beach | |||
| SW1 | COMPLETE | 09/15/2023 | 09/18/2023 |
| Note: Released By: TIM BAKER - (386)986-4726 - TBAKER@PALMCOASTGOV.COM | |||
| ZON | COMPLETE | 09/15/2023 | 09/15/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| BADMIN | COMPLETE | 09/15/2023 | 09/18/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/08/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/08/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/06/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/06/2024 |
| REINSPECTION FEE | ¤40.00 | 05/06/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 05/06/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 05/06/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 05/06/2024 |
| SW ENG - INSPECTION 20 | ¤20.00 | 05/06/2024 |
| PLAN REVIEW - REVISION | ¤32.50 | 05/06/2024 |
| REINSPECTION RESIDENTIAL | ¤40.00 | 05/06/2024 |
| SW ENG INSPECTION 80 | ¤80.00 | 10/02/2023 |
| SW ENG PRE APRON | ¤30.00 | 10/02/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 10/02/2023 |
| SW ENG RES REVIEW 200 | ¤200.00 | 10/02/2023 |
| TRANS IMPACT FEE ADMIN | ¤54.36 | 10/02/2023 |
| TRANS IMPACT FEE ADMIN | (¤54.36) | 10/02/2023 |
| SEWER CREDIT | (¤1,466.00) | 10/02/2023 |
| SEWER INSPECTION | ¤25.00 | 10/02/2023 |
| SEWER CAPITAL FACILITY | ¤5,344.82 | 10/02/2023 |
| WATER CAPITAL FACILITY FEE | ¤3,923.88 | 10/02/2023 |
| SITE PLAN 30 | ¤30.00 | 10/02/2023 |
| SURCHARGE FS 533.721 | ¤3.47 | 10/02/2023 |
| SURCHARGE - FS 468.631 | ¤5.20 | 10/02/2023 |
| SW ENG - FOUNDATION SURVEY | ¤20.00 | 10/02/2023 |
| WATER- TURN ON | ¤25.00 | 10/02/2023 |
| ADJUSTMENT 50% | (¤346.82) | 10/02/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 10/02/2023 |
| INSPECTION - RESIDENTIAL | ¤517.00 | 10/02/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤146.64 | 10/02/2023 |
| CONNECTION FEES | ¤1,166.26 | 10/02/2023 |
| FIRE IMPACT FEE ADMIN | ¤12.62 | 10/02/2023 |
| FIRE IMPACT FEE ADMIN | (¤12.62) | 10/02/2023 |
| FC IMPACT FEE EMS | ¤62.00 | 10/02/2023 |
| IMPACT FEE FIRE | ¤420.52 | 10/02/2023 |
| FC IMPACT FEE LAW ENFORCEMENT | ¤218.00 | 10/02/2023 |
| FC IMPACT FEE LIBRARY | ¤268.00 | 10/02/2023 |
| IMPACT FEE PARKS | ¤1,769.15 | 10/02/2023 |
| IMPACT FEE SCHOOL | ¤5,450.00 | 10/02/2023 |
| IMPACT FEE TRANSPORTATION | ¤1,812.00 | 10/02/2023 |
| WATER -IRRIGATION INSPECTION | ¤25.00 | 10/02/2023 |
| PARKS IMPACT FEE ADMIN | ¤53.07 | 10/02/2023 |
| PARKS IMPACT FEE ADMIN | (¤53.07) | 10/02/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤20,131.62 |