Permit #2023090696

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7006-00080-0150
Total Square Footage: 1786 sqft
Block: 00080
Subdivision: 2213 - SECTION 6-FLORIDA PARK
Job Phone: 386-225-1722
Location Address: 13 FLAMETREE CT
Type: PO - POOL
Issue Date: 10/19/2023
NOC: RECORDED
Applicant name: MICHAEL MARINO HANSEN
Owner: GROVER MICHAEL

Address

13 FLAMETREE CT

PALM COAST, FL 32137

Lot: 0150
Contracted Stated Job Value: ¤101,250.00
Job Description: SWIMMING POOL-EXISTING FENCE
Type: CN

Contractor

PALM COAST POOLS, LLC
Status Location Address State License Number Phone
ACTIVE

29 COLUMBUS CT

PALM COAST, FL 32137

RP252555609 (Exp: 08/31/2027) 386-225-1722

Sub Contractors

BENJAMIN D DEWITT
Status Location Address State License Number Phone
ACTIVE

356 UNDERWOOD TRAIL

PALM COAST, FL 32164

ER13016065 (Exp: 08/31/2026) 321-262-4104

Inspection History

Type Request Date Result Inspector
POOL FINAL 07/24/2024 FINAL APPROVED FWILLIS
Note: 7/11/2024 - PREVIOUS INSPECTION NOTES 7/11/2024 Gates are not meeting the listed code below. Latches have not been installed at the minimum height. The gate at the right side fence is not swinging outward. 7/10/2024 - PREVIOUS INSPECTION NOTES 7/10/24 Corrections from the previous inspection have not been corrected. Please ensure both gates are completed for reinspection. 6/27/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 6/27/2024 2:59:41 PM *** ALL GATES SHALL BE SELF CLOSING AND LATCHING LOCATED N POOL SIDE,AND PROVIDE LATCH AT 54” FROM BOTTOM OF GATE,MUST SWING OUTWARD…FBC..4501.17.1.8
POOL FINAL 07/11/2024 Disapproved -FEE REQUIRED JWALKER
Note: 7/11/2024 Gates are not meeting the listed code below. Latches have not been installed at the minimum height. The gate at the right side fence is not swinging outward. 7/10/2024 - PREVIOUS INSPECTION NOTES 7/10/24 Corrections from the previous inspection have not been corrected. Please ensure both gates are completed for reinspection. 6/27/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 6/27/2024 2:59:41 PM *** ALL GATES SHALL BE SELF CLOSING AND LATCHING LOCATED N POOL SIDE,AND PROVIDE LATCH AT 54” FROM BOTTOM OF GATE,MUST SWING OUTWARD…FBC..4501.17.1.8
POOL FINAL 07/10/2024 Disapproved - NO FEE JWALKER
Note: 7/10/24 Corrections from the previous inspection have not been corrected. Please ensure both gates are completed for reinspection. 6/27/2024 - PREVIOUS INSPECTION NOTES *** NOTES ADDED BY LMILLER 6/27/2024 2:59:41 PM *** ALL GATES SHALL BE SELF CLOSING AND LATCHING LOCATED N POOL SIDE,AND PROVIDE LATCH AT 54” FROM BOTTOM OF GATE,MUST SWING OUTWARD…FBC..4501.17.1.8
POOL FINAL 06/27/2024 Disapproved -FEE REQUIRED LMILLER
Note: *** NOTES ADDED BY LMILLER 6/27/2024 2:59:41 PM *** ALL GATES SHALL BE SELF CLOSING AND LATCHING LOCATED N POOL SIDE,AND PROVIDE LATCH AT 54” FROM BOTTOM OF GATE,MUST SWING OUTWARD…FBC..4501.17.1.8
U -UTILITY RESIDENTIAL FINAL 06/25/2024 FINAL APPROVED LFITZGERALD
ROW- FINAL SURVEY/GRADING CERTIFICATION 06/21/2024 APPROVED GBERTOLA
ROW FIELD SURVEY /GRADING CERTIFICATION 06/21/2024 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ROW - FINAL INSPECTION 06/21/2024 APPROVED GBERTOLA
Note: AT THE TIME OF THE INSPECTION, ALL MINIMUM CITY REQUIREMENTS WERE MET. IT IS THE BUILDER'S RESPONSIBILITY TO ENSURE THAT NOTHING CHANGES AFTER THIS INSPECTION IS APPROVED
ELECTRIC AND ALARM 02/29/2024 APPROVED AGAETANO
POOL DECK 12/11/2023 APPROVED BTAYLOR
Note: 12/6/2023 - PREVIOUS INSPECTION NOTES not reaady for inspection (all pool piping must be included in the test you have pipes excluded from the test at the manifold, also the grading is not ready for the inspection, the footings have cave ins that do not allow clearance for the steel, etc. etc. inspection stopped
POOL DECK 12/06/2023 Disapproved - NO FEE LMILLER
Note: not reaady for inspection (all pool piping must be included in the test you have pipes excluded from the test at the manifold, also the grading is not ready for the inspection, the footings have cave ins that do not allow clearance for the steel, etc. etc. inspection stopped
STEEL AND GROUND 10/26/2023 APPROVED AGAETANO

Review History

Department Status Date In Date Out
BLD COMPLETE 09/25/2023 09/26/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD HOLD 09/18/2023 09/18/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. Provide detail or note on plans showing existing fence or screen enclosure complies with R4501.17.1.8. Show door swing and latch height. 2. Plans have a different permit number on them. Only upload plans once. You are doing them twice.
ELEC COMPLETE 09/18/2023 09/18/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
MECH COMPLETE 09/18/2023 09/19/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
SW1 COMPLETE 09/18/2023 09/21/2023
Note: Released By: GABRIEL BERTOLA - (386)986-7660 - GBERTOLA@PALMCOASTGOV.COM
ZON COMPLETE 09/18/2023 09/18/2023
Note: Released By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 07/23/2024
REINSPECTION RESIDENTIAL ¤40.00 07/09/2024
SURCHARGE FS 533.721 ¤2.00 10/19/2023
SURCHARGE - FS 468.631 ¤2.02 10/19/2023
SW ENG INSPECTION 40 ¤40.00 10/19/2023
SW ENG - REVIEW 20 ¤20.00 10/19/2023
SITE PLAN 30 ¤30.00 10/19/2023
ADJUSTMENT 50% (¤134.78) 10/19/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/19/2023
INSPECTION- POOL ¤160.00 10/19/2023
PLAN REVIEW - RESIDENTIAL ¤79.56 10/19/2023
Fees Total Due: ¤0.00 Total Paid: ¤308.80