I want to search for...

Permit #2023090916

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7058-00720-0030
CONDITIONED SPACE: 703 sqft
CONDITIONED SPACE: 288 sqft
OPENED PORCH (WITH ROOF) : 300 sqft
Total Square Footage: 1291 sqft
Block: 00720
Subdivision: 2215 - SECTION 58-SEMINOLE PARK
Job Phone: 386-597-9271
Location Address: 12 SECKEL CT
Type: BA - BUILDING ADDITION
Issue Date: 11/28/2023
NOC: RECORDED
Applicant name: GARY W MCCAIN
Owner: ARTHUR DEANNA L

Address

12 SECKEL CT

PALM COAST, FL 32164

Lot: 0030
Contracted Stated Job Value: ¤125,000.00
Job Description: ROOM ADDITION
Type: CN

Contractor

MCCAIN CONSTRUCTION LLC
Status Location Address State License Number Phone
ACTIVE

15 WEIDNER PLACE

PALM COAST, FL 32164

CBC1261573 (Exp: 08/31/2026) 386-447-0035

Sub Contractors

BANVILLE BARRETT
Status Location Address State License Number Phone
ACTIVE

6826 NW 32ND COURT

MARGATE, FL 33063

EC13001949 (Exp: 08/31/2026) 386-795-4649
HEATH EDWARD SANFORD
Status Location Address State License Number Phone Fax
ACTIVE

1351 HAZELNUT ST

BUNNELL, FL 32110

CFC1427527 (Exp: 08/31/2026) 386-445-2532 386-445-5575
CHARLES WEYANT
Status Location Address State License Number Phone
ACTIVE

PO BOX 1261

FLAGLER BEACH, FL 32136

CAC1815058 (Exp: 08/31/2026) (386)246-7745
DANIEL DAVID RUTKOWSKI III
Status Location Address State License Number Phone Fax
ACTIVE

1687 STATE AVENUE

HOLLY HILL, FL 32117

CCC1328639 (Exp: 08/31/2026) 386-290-7490 386-256-0001

Inspection History

Type Request Date Result Inspector
ROW - FINAL INSPECTION 09/12/2024 APPROVED - AS NOTED FSLADISH
Note: 9/13/24 Spoke with homeoner, she indicated no adverse drainage conditions with addition. She indicated that because of the haevy rains lately they were haing difficulty getting sod. As there is only a small area behind the swale on the ROW area that needs sod placed I am approving this inspection as noted that the area will be completed as soon as possible.
U -UTILITY RESIDENTIAL FINAL 09/12/2024 FINAL APPROVED BWRIGHT
BLD - BUILDING FINAL 09/11/2024 FINAL APPROVED BTAYLOR
SEWER TIE IN 08/26/2024 APPROVED MGIBSON
INSULATION 05/28/2024 APPROVED BTAYLOR
LATH/BRICK/ WATER BARRIER 05/20/2024 APPROVED BTAYLOR
ALL ROUGH 05/20/2024 APPROVED BTAYLOR
ROOF VALLEY & METAL 04/03/2024 APPROVED BTAYLOR
WALL SHEATHING 03/26/2024 APPROVED RSIMS
ROOF SHEATHING / BRACES/TIES/DOWN CELL 03/26/2024 APPROVED RSIMS
FRAMING 03/18/2024 APPROVED BTAYLOR
FRAMING 03/15/2024 CANCELLED BY APPLICANT WEB
TIE BEAM / LINTEL 02/27/2024 APPROVED BTAYLOR
MONOLITHIC SLAB 01/10/2024 APPROVED BTAYLOR
PLUMBING 1ST ROUGH UNDERGROUND 01/05/2024 APPROVED MGIBSON

Review History

Department Status Date In Date Out
ZON COMPLETE 11/27/2023 11/27/2023
Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM
SW1 COMPLETE 11/27/2023 11/27/2023
Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM
MECH COMPLETE 11/27/2023 11/27/2023
Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM
ZON HOLD 11/02/2023 11/03/2023
Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide the square footage of the addition and new patio on floor plan Site plan/Survey must also show the addition and covered patio dimensions
ZON HOLD 10/31/2023 11/01/2023
Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comment Not addressed ELEVATION PLAN: Please provide the square footage of the proposed plans SITE PLANS: Please provide the setbacks on the site plan from proposed addition.
SW1 HOLD 10/31/2023 11/07/2023
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM STILL NEED ALL DEMINTIONS OF ALL PATIOS
MECH HOLD 10/31/2023 11/03/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. ok REPEAT COMMENT: 2. Energy calcs say R5 insulation on block walls nd R30 in vented attic. Plans show R5 on one page and R4.1 and R19 in unvented attic on another. Revise to match. REVISE ENERGY CALCS REPEAT COMMENT: 3. Wall for dryer vent is only 4". revise plans to show a 6" wall
ELEC COMPLETE 10/31/2023 11/01/2023
Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM
BLD COMPLETE 09/21/2023 09/27/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All comments from FBC Residential 2020 7Th edition 1. Plans show conflicting information on insulation and ventilated roof. Detail 1F. One shows R30 insulation in vented attic the other shows R19 in unvented attic. Revise to match. 107.2.1 2. Detail 1F shows 1 layer of 30# felt. and also shows peel & stick. Revise to match. 107.2.1 3. Rename room for its purpose and use. Cannot say existing covered porch. 107.2.1 4. Add note to plans indicating all new smoke alarms are to be interconnected with existing smoke detectors in home and that existing smoke alarms are subject to inspection to ensure they are interconnected at time of final inspection. R314.2.2, R314.4. 5. Add note to plans that carbon monoxide alarms shall be provided within 10 feet of all existing bedrooms and that all carbon monoxide alarms are subject to inspection for proper location and operation at time of final inspection R315.1. R315.1.3. 6. Provide details on shower. Is it tile? Provide backer board materials for wall tile in shower per R702.4.2 listed in Table R702.4.2
ELEC HOLD 09/21/2023 09/26/2023
Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. new smoke alarm in new bedroom to be interconnected with other existing smoke alarms and that existing smoke alarms are subject to inspection at Final Building Inspection to ensure interconnectedness and proper operation. R314.2.2, R314.4. 2. carbon monoxide alarms shall be provided outside, but within 10 feet of entrances to all existing bedrooms and that all carbon monoxide alarms including those in existing portions of the home are subject to inspection at Final Building Inspection to ensure proper operation. R315.1.
GAS CANCEL 09/21/2023 09/25/2023
MECH HOLD 09/21/2023 09/26/2023
Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show conflicting information on insulation and ventilated roof. Detail 1F. One shows R30 insulation in vented attic the other shows R19 in unvented attic. Revise to match. 2. Energy calcs say R5 insulation on block walls nd R30 in vented attic. Plans show R5 on one page and R4.1 and R19 in unvented attic on another. Revise to match. 3. Wall for dryer vent is only 4". revise plans to show a 6" wall
PLUM COMPLETE 09/21/2023 09/27/2023
Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM
SW1 HOLD 09/21/2023 09/25/2023
Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM 1) NEED TO HAVE DEMINTIONS OF ALL PROPOSED CONSTRUCTION AREAS 2) NEED TO HAVE FLOW ARROWS TO SHPW ALL NEW DRAINAGE 3) THE SITE PLAN NEEDS TO HAVE AN UP DATED SURVEY TO SHOW ALL EXISTING STRUCTURES AND DRAINAGE OF LOT The signature and date must be under a raised seal. The Lot Grading Plan may be superimposed on the Topographic Survey. Legible, clean, original signed and sealed residential building final surveys, less than twelve (12) months old, may be acceptable as a topographic survey for permitting purposes

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
ADJUSTMENT 50% (¤339.76) 11/28/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 11/28/2023
INSPECTION - RESIDENTIAL ¤506.00 11/28/2023
PLAN REVIEW - RESIDENTIAL ¤143.52 11/28/2023
RECORDING FEE REIMBURSE DOC ¤10.00 11/28/2023
SURCHARGE FS 533.721 ¤3.40 11/28/2023
SURCHARGE - FS 468.631 ¤5.10 11/28/2023
SW ENG - INSPECTION 20 ¤20.00 11/28/2023
SW ENG - REVIEW 20 ¤20.00 11/28/2023
SITE PLAN 30 ¤30.00 11/28/2023
Fees Total Due: ¤0.00 Total Paid: ¤428.26