I want to search for...
Permit #2023090916
Permit Details
Status: FINAL
| Parcel Id: 07-11-31-7058-00720-0030 |
| CONDITIONED SPACE: 703 sqft |
| CONDITIONED SPACE: 288 sqft |
| OPENED PORCH (WITH ROOF) : 300 sqft |
| Total Square Footage: 1291 sqft |
| Block: 00720 |
| Subdivision: 2215 - SECTION 58-SEMINOLE PARK |
| Job Phone: 386-597-9271 |
| Location Address: 12 SECKEL CT |
| Type: BA - BUILDING ADDITION |
| Issue Date: 11/28/2023 |
| NOC: RECORDED |
| Applicant name: GARY W MCCAIN |
| Owner: ARTHUR DEANNA L |
|
Address 12 SECKEL CT PALM COAST, FL 32164 |
| Lot: 0030 |
| Contracted Stated Job Value: ¤125,000.00 |
| Job Description: ROOM ADDITION |
| Type: CN |
Contractor
MCCAIN CONSTRUCTION LLC
| Status | Location Address | State License Number | Phone |
| ACTIVE |
15 WEIDNER PLACE PALM COAST, FL 32164 |
CBC1261573 (Exp: 08/31/2026) | 386-447-0035 |
Sub Contractors
BANVILLE BARRETT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
6826 NW 32ND COURT MARGATE, FL 33063 |
EC13001949 (Exp: 08/31/2026) | 386-795-4649 |
HEATH EDWARD SANFORD
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1351 HAZELNUT ST BUNNELL, FL 32110 |
CFC1427527 (Exp: 08/31/2026) | 386-445-2532 | 386-445-5575 |
CHARLES WEYANT
| Status | Location Address | State License Number | Phone |
| ACTIVE |
PO BOX 1261 FLAGLER BEACH, FL 32136 |
CAC1815058 (Exp: 08/31/2026) | (386)246-7745 |
DANIEL DAVID RUTKOWSKI III
| Status | Location Address | State License Number | Phone | Fax |
| ACTIVE |
1687 STATE AVENUE HOLLY HILL, FL 32117 |
CCC1328639 (Exp: 08/31/2026) | 386-290-7490 | 386-256-0001 |
Inspection History
| Type | Request Date | Result | Inspector |
| ROW - FINAL INSPECTION | 09/12/2024 | APPROVED - AS NOTED | FSLADISH |
| Note: 9/13/24 Spoke with homeoner, she indicated no adverse drainage conditions with addition. She indicated that because of the haevy rains lately they were haing difficulty getting sod. As there is only a small area behind the swale on the ROW area that needs sod placed I am approving this inspection as noted that the area will be completed as soon as possible. | |||
| U -UTILITY RESIDENTIAL FINAL | 09/12/2024 | FINAL APPROVED | BWRIGHT |
| BLD - BUILDING FINAL | 09/11/2024 | FINAL APPROVED | BTAYLOR |
| SEWER TIE IN | 08/26/2024 | APPROVED | MGIBSON |
| INSULATION | 05/28/2024 | APPROVED | BTAYLOR |
| LATH/BRICK/ WATER BARRIER | 05/20/2024 | APPROVED | BTAYLOR |
| ALL ROUGH | 05/20/2024 | APPROVED | BTAYLOR |
| ROOF VALLEY & METAL | 04/03/2024 | APPROVED | BTAYLOR |
| WALL SHEATHING | 03/26/2024 | APPROVED | RSIMS |
| ROOF SHEATHING / BRACES/TIES/DOWN CELL | 03/26/2024 | APPROVED | RSIMS |
| FRAMING | 03/18/2024 | APPROVED | BTAYLOR |
| FRAMING | 03/15/2024 | CANCELLED BY APPLICANT | WEB |
| TIE BEAM / LINTEL | 02/27/2024 | APPROVED | BTAYLOR |
| MONOLITHIC SLAB | 01/10/2024 | APPROVED | BTAYLOR |
| PLUMBING 1ST ROUGH UNDERGROUND | 01/05/2024 | APPROVED | MGIBSON |
Review History
| Department | Status | Date In | Date Out |
| ZON | COMPLETE | 11/27/2023 | 11/27/2023 |
| Note: Released By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM | |||
| SW1 | COMPLETE | 11/27/2023 | 11/27/2023 |
| Note: Released By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM | |||
| MECH | COMPLETE | 11/27/2023 | 11/27/2023 |
| Note: Released By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM | |||
| ZON | HOLD | 11/02/2023 | 11/03/2023 |
| Note: Held By: ALISHA MOBLEY - (386)986-3751 - AMOBLEY@PALMCOASTGOV.COM Please provide the square footage of the addition and new patio on floor plan Site plan/Survey must also show the addition and covered patio dimensions | |||
| ZON | HOLD | 10/31/2023 | 11/01/2023 |
| Note: Held By: CINDY CHIRI-GONCALVES - (386)986-4737 - CGONCALVES@PALMCOASTGOV.COM Repeat comment Not addressed ELEVATION PLAN: Please provide the square footage of the proposed plans SITE PLANS: Please provide the setbacks on the site plan from proposed addition. | |||
| SW1 | HOLD | 10/31/2023 | 11/07/2023 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM STILL NEED ALL DEMINTIONS OF ALL PATIOS | |||
| MECH | HOLD | 10/31/2023 | 11/03/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. ok REPEAT COMMENT: 2. Energy calcs say R5 insulation on block walls nd R30 in vented attic. Plans show R5 on one page and R4.1 and R19 in unvented attic on another. Revise to match. REVISE ENERGY CALCS REPEAT COMMENT: 3. Wall for dryer vent is only 4". revise plans to show a 6" wall | |||
| ELEC | COMPLETE | 10/31/2023 | 11/01/2023 |
| Note: Released By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM | |||
| BLD | COMPLETE | 09/21/2023 | 09/27/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM All comments from FBC Residential 2020 7Th edition 1. Plans show conflicting information on insulation and ventilated roof. Detail 1F. One shows R30 insulation in vented attic the other shows R19 in unvented attic. Revise to match. 107.2.1 2. Detail 1F shows 1 layer of 30# felt. and also shows peel & stick. Revise to match. 107.2.1 3. Rename room for its purpose and use. Cannot say existing covered porch. 107.2.1 4. Add note to plans indicating all new smoke alarms are to be interconnected with existing smoke detectors in home and that existing smoke alarms are subject to inspection to ensure they are interconnected at time of final inspection. R314.2.2, R314.4. 5. Add note to plans that carbon monoxide alarms shall be provided within 10 feet of all existing bedrooms and that all carbon monoxide alarms are subject to inspection for proper location and operation at time of final inspection R315.1. R315.1.3. 6. Provide details on shower. Is it tile? Provide backer board materials for wall tile in shower per R702.4.2 listed in Table R702.4.2 | |||
| ELEC | HOLD | 09/21/2023 | 09/26/2023 |
| Note: Held By: JOSH MUNSON - (386)986-4736 - JMUNSON@PALMCOASTGOV.COM 1. new smoke alarm in new bedroom to be interconnected with other existing smoke alarms and that existing smoke alarms are subject to inspection at Final Building Inspection to ensure interconnectedness and proper operation. R314.2.2, R314.4. 2. carbon monoxide alarms shall be provided outside, but within 10 feet of entrances to all existing bedrooms and that all carbon monoxide alarms including those in existing portions of the home are subject to inspection at Final Building Inspection to ensure proper operation. R315.1. | |||
| GAS | CANCEL | 09/21/2023 | 09/25/2023 |
| MECH | HOLD | 09/21/2023 | 09/26/2023 |
| Note: Held By: CHRIS PISCITELLI - (386)986-2574 - CPISCITELLI@PALMCOASTGOV.COM 1. Plans show conflicting information on insulation and ventilated roof. Detail 1F. One shows R30 insulation in vented attic the other shows R19 in unvented attic. Revise to match. 2. Energy calcs say R5 insulation on block walls nd R30 in vented attic. Plans show R5 on one page and R4.1 and R19 in unvented attic on another. Revise to match. 3. Wall for dryer vent is only 4". revise plans to show a 6" wall | |||
| PLUM | COMPLETE | 09/21/2023 | 09/27/2023 |
| Note: Released By: PATRICK BUCKLEY - (386)986-3786 - PBUCKLEY@PALMCOASTGOV.COM | |||
| SW1 | HOLD | 09/21/2023 | 09/25/2023 |
| Note: Held By: PARREN FLANAGAN - (386)986-2392 - PFLANAGAN@PALMCOASTGOV.COM 1) NEED TO HAVE DEMINTIONS OF ALL PROPOSED CONSTRUCTION AREAS 2) NEED TO HAVE FLOW ARROWS TO SHPW ALL NEW DRAINAGE 3) THE SITE PLAN NEEDS TO HAVE AN UP DATED SURVEY TO SHOW ALL EXISTING STRUCTURES AND DRAINAGE OF LOT The signature and date must be under a raised seal. The Lot Grading Plan may be superimposed on the Topographic Survey. Legible, clean, original signed and sealed residential building final surveys, less than twelve (12) months old, may be acceptable as a topographic survey for permitting purposes |
Fees & Payments
(Permit is not ready for pickup until the permit has been processed and fees appear)
| Description | Amount Due | Date Paid |
| ADJUSTMENT 50% | (¤339.76) | 11/28/2023 |
| ADMINISTRATIVE RESIDENTIAL | ¤30.00 | 11/28/2023 |
| INSPECTION - RESIDENTIAL | ¤506.00 | 11/28/2023 |
| PLAN REVIEW - RESIDENTIAL | ¤143.52 | 11/28/2023 |
| RECORDING FEE REIMBURSE DOC | ¤10.00 | 11/28/2023 |
| SURCHARGE FS 533.721 | ¤3.40 | 11/28/2023 |
| SURCHARGE - FS 468.631 | ¤5.10 | 11/28/2023 |
| SW ENG - INSPECTION 20 | ¤20.00 | 11/28/2023 |
| SW ENG - REVIEW 20 | ¤20.00 | 11/28/2023 |
| SITE PLAN 30 | ¤30.00 | 11/28/2023 |
| Fees | Total Due: ¤0.00 | Total Paid: ¤428.26 |