I want to search for...

Permit #2023091025

Permit Details

Status: FINAL

Parcel Id: 07-11-31-7007-00510-0040
Block: 00510
Subdivision: 2185 - SECTION 7-FLORIDA PARK
Job Phone: 727-482-8052
Location Address: 13 FRANCIS LN
Type: WD - WINDOWS/DOORS
Issue Date: 10/02/2023
NOC: RECORDED
Applicant name: THOMAS LIPPERT
Owner: SHEVCHENKO IGOR & YULIYA H&W

Address

13 FRANCIS LANE

PALM COAST, FL 32137

Lot: 0040
Contracted Stated Job Value: ¤5,000.00
Job Description: REF 2022061550 REPLACE WINDOWS (4) SIZE FOR SIZE
Type: CN
Original Permit #: 2022061550

Contractor

HOME PERFORMANCE ALLIANCE, INC
Status Location Address Mailing Address State License Number Phone
INACTIVE

11399 16TH CT N

ST PETERSBURG, FL 33716

STE 100

ST PETERSBURG, FL 33716

CGC1508826 (Exp: 08/31/2026) 727-538-4140

Inspection History

Type Request Date Result Inspector
FINAL - BUILDING MISC 11/21/2023 FINAL APPROVED AGAETANO
Note: 11/15/2023 - PREVIOUS INSPECTION NOTES 11/2/2023 - PREVIOUS INSPECTION NOTES 11/2/23: Permit & documents were not readily available for inspection. (because the Homeowner was not informed of the Inspection date). FBC 107.3.1 1). Windows are not anchored properly (missing anchors) and do not have the approved anchors installed. (concrete type required). 2). Windows do not operate properly. (will not stay closed on their own without being locked). 11-15-2023 Rng door bell and knocked on the door. No inspection, doors locked, need access for inspection. FBC R110.1
FINAL - BUILDING MISC 11/15/2023 Disapproved - NO FEE AGAETANO
Note: 11/2/2023 - PREVIOUS INSPECTION NOTES 11/2/23: Permit & documents were not readily available for inspection. (because the Homeowner was not informed of the Inspection date). FBC 107.3.1 1). Windows are not anchored properly (missing anchors) and do not have the approved anchors installed. (concrete type required). 2). Windows do not operate properly. (will not stay closed on their own without being locked). 11-15-2023 Rng door bell and knocked on the door. No inspection, doors locked, need access for inspection. FBC R110.1
FINAL - BUILDING MISC 11/02/2023 Disapproved -FEE REQUIRED RSIMS
Note: 11/2/23: Permit & documents were not readily available for inspection. (because the Homeowner was not informed of the Inspection date). FBC 107.3.1 1). Windows are not anchored properly (missing anchors) and do not have the approved anchors installed. (concrete type required). 2). Windows do not operate properly. (will not stay closed on their own without being locked).

Fees & Payments

(Permit is not ready for pickup until the permit has been processed and fees appear)
Description Amount Due Date Paid
REINSPECTION RESIDENTIAL ¤40.00 11/14/2023
SURCHARGE FS 533.721 ¤2.00 10/02/2023
SURCHARGE - FS 468.631 ¤2.00 10/02/2023
ADJUSTMENT 50% (¤45.00) 10/02/2023
ADMINISTRATIVE RESIDENTIAL ¤30.00 10/02/2023
INSPECTION - RESIDENTIAL ¤60.00 10/02/2023